The BASA Guide to the ISO 11600 Classification of Sealants for Building Construction



Similar documents
Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Understanding BS EN 771-3: Aggregate concrete masonry units

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

Crystal Clear Sealant

Industry. Rail Leading Innovation in a Dynamic Industry. Sika Services AG

SOLAR SOLUTIONS BONDED MOUNTING TECHNOLOGY. DURABLE BONDING OF PV MODULES TO MOUNTING SYSTEMS WITH Sikasil

DL CHEMICALS DECO SNJF PARAFILL PARQUET EXTERIOR TRANSPARENT STRUCTURE

TECHNICAL BULLETIN TECHNICAL DESCRIPTION DESCRIPTION OVERVIEW PROGRAMS. Data Sheet. Pilkington Toughened Safety Glass

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

FIRESTOPPING & SMOKE SEALS

Formwork Direct International Ltd Phone No +44 (0151) Fax no +44 (0151)

Chapter 2 Basis of design and materials

Ironwork in Highways -Whole Life Cost Perspective. Reducing cost through collaboration

WOOD FLOORING ADHESIVES

AKRAPLAST Sistemi S.p.A. - I Novate Milanese (Mi) - via Cascina del Sole, 70 Tel: (+39) Fax: (+39)

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick

SmartPly OSB3 SMARTPLY

Glass partitions SFB 3074

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Rockwool Cladding Roll

Product Data Sheet ROCKPANEL Rockclad

A. Work on this project shall consist of, but is not limited to, the following:

SAND CAST CHILL CAST LM4 - TF

BUILDING & CONSTRUCTION

Requirements on secondary insulating glass sealants

High Performance Building Materials SCREEDS REPAIR MORTARS LEVELLING & SMOOTHING WATERPROOFING TILE ADHESIVES & GROUTS PRIMERS & ADDITIVES

WATERPROOFING OF WET ROOMS

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

Redux Film Adhesives, Foaming Films, Primers and Liquid Shims. About HEXCEL

Linear thermal transmittance of the assembly of the glazing and the frame in windows

BETONYP building boards. The modern way of living.

ICS: Strengthening retrofitting of reinforced concrete structures by gluing of fibre reinforced polymeric fabrics (FRP fabrics)

Composite Design Fundamentals. David Richardson

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

Approved Document Q: Security

How To Test A Base Axe

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

Building façade maintenance

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

Classification of reaction to fire of glass products Recommendation from Glass for Europe

Sealing & Bonding Sika solutions for Window Installation

Swimming Pool Tiling Specialists

ANSI/AGRSS Automotive Glass Replacement Safety Standard

Light Architecture. Colors Sweden. Light

PROPERTIES AND MIX DESIGNATIONS

Heat-treated Glass. GUARDIAN A Company of Vision PATTERNED GLASS HORTICULTURAL GLASS SUN PERFORMANCE GLASS VISION GLASS SILKSCREENED GLASS THIN GLASS

Mold Preventing I nterior System

POLYURETHANE FOAM CONCEPT

PmB Expansion Joints World leaders in expansion joint technology

Araldite AV 170. Advanced Materials. One component epoxy adhesive. Structural Adhesives. Key properties. Description. Product data.

Proteus Waterproofing roof systems are tested to the most rigorous international standards, ensuring they will easily deal with our climate.

3 Marine Adhesives and Sealants

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Waterproofing construction Joints

The Warm Edge for insulating glass

Information leaflet Printing Inks for Food Packaging

RTV162. Electronic Grade Silicone Adhesive Sealant

Dubai Municipality Standard DMS 1: Part 5: 2004

Fire Resistant Systems

Code of Practice for fire resisting metal doorsets

PRODUCT DATASHEET. Confidex Ironside Micro CONTENTS

Rockwool Flexi Insulation Application Guide

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Mechanical Properties of Metals Mechanical Properties refers to the behavior of material when external forces are applied

PanelTack. For the bonding of steni Colour type 7 façade panels. steni Colour 7. steni Colour 7

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Important Information

Temperature C Cure time to reach hours LSS > 1MPa minutes

RTV159. RTV157 and RTV159 High Strength Silicone Adhesive Sealants

EDUCATIONAL GUIDE TO PROPERTIES OF MASONRY MORTAR

Product Sheet. Silicone Adhesive Sealants. RTV Silicone Adhesive Sealants

Phosphoric Acid Anodized Aluminum Honeycomb

Desmear and Plating Through Hole Considerations and Experiences for Green PCB Production

Eurocode 2: Design of concrete structures

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 34 C IED (2010/75/EU) (calculated)

SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES

Welded Fabric. The CARES Guide to Reinforcing Steels Part 5. Installation of welded fabric on a major contract. 1.0 Introduction

Calculating Creepage and Clearance Early Avoids Design Problems Later Homi Ahmadi

Window Installation Instructions

Two component epoxy paste adhesive

best practice guide BS EN 1154 Controlled Door Closing Devices to in association with

A GUIDE TO WINDOW AND DOOR SELECTION

Precast Concrete Parking Structures

PART 1 GENERAL 1.1 SECTION INCLUDES

BYG DTU. Thermal properties of window frame Type 1 Sheet: 1. Type: Side, top and bottom profile. Source file: Format: dwg/dxf bmp

Sikaflex Sealant Installation. Sika Corporation

Windows, French doors, folding windows, terrace doors SFB 1074 with low U-values

peel adhesion 2 breaking load 4 rolling ball 6 shear adhesion 7 carton test 9 summary test methods 11

IMPORTANT INFORMATION

Guide to adhesively mounting accelerometers

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

Choosing the Right Mortar for the Job

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

Transcription:

The BASA Guide to the ISO 11600 Classification of Sealants for Building Construction SEALANTS IN BUILDING AND CONSTRUCTION Glazing Sealants (G) Construction Sealants (F) Class 25 Class 25LM Class 25 Class 25LM The Sealant Manufacturers Group within the British Adhesives and Sealants Association (BASA) has undertaken to promote the use of ISO 11600 for the mutual benefit of the manufacturers and users of sealants in construction and glazing. BS EN ISO11600, together with BS 6093 (Design of Joints and Jointing in Building Construction), BS 6213 (Selection Constructional Sealants), BS 8000. Pts 7 and 16 (Workmanship on Building Sites) form a powerful suite of standards, which if applied properly, will promote high quality products, increase sealant durability and improve site practice. At the same time poor products and application will be marginalised. BASA is committed to raising standards in the industries it represents. In addition to this Guidance Note, the sealant manufacturing companies in BASA offer lectures and seminars on the selection of sealants. Class 20 Class 20LM Class 20 Class 20HM Class 20HM Class 20LM Class 12,5 Class 12,5E Class 12,5P Class 7,5 Class 7,5P For further information contact The Secretary. BASA British Adhesives & Sealants Association 33 Fellowes Way, Stevenage, Herts, SG2 8BW. Telephone: 01438 358514 or see details on the BASA web site www.basa.uk.com The British Adhesives & Sealants Association Printed 1999

The Classification of Sealants for Construction and Glazing The BASA Guide to BS EN ISO 11600 and its Application NOTES Introduction Part One: User Guide The ISO 11600 Sealant Classes 3 The ISO 11600 Designation 4 How to use ISO 11600 5 F Class or G Class 5 Movement Capability 5 5 6 Specifiers Sealant Designation 6 Other Sealant Requirements 6 Using your Sealant Supplier 6 Part Two: Determining Parameters for Sealant Classification (Test methods) End Use (Type) 7 7 Movement Capability 8 8 Other Factors 9 1 Substrates and Primers Flow Loss of Volume and Mass 10 Adhesion

with a room temperature tensile modulus greater than 0,4Nmm -2 is classed as high modulus (HM). Sealants of 0,4 Nmm -2 or less are classed as low modulus (LM). These suffixes are used only with the high movement classes of elastic sealant (20 and 25), i.e. modulus is a more significant property in sealants used to seal joints likely to move a lot or rapidly. High modulus sealants used in these circumstances may place considerable stress on the building substrate and on the adhesive bond between sealant and substrate. The modulus of a sealant can increase considerably at lower temperatures. Hence, BS EN ISO 8339 also measures the tensile modulus at -20 C. At this temperature a sealant with a tensile modulus greater than 0,6Nmm -2 is classed as high modulus, even if it tested as low modulus at room temperature. Other factors in ISO 11600 i) Substrates and primers The designation given to the sealant following classification indicates what substrates were used in the testing and if primers were used in the testing. This information will be shown on the sealant packaging. The specifier has to be satisfied that the sealant testing was relevant to the actual substrates to be sealed and, if necessary, ask for additional testing on specific substrates. There are three standard substrates used in ISO 11600 tests, mortar, glass and anodized aluminium. ii) Flow. Test method: BS EN ISO 7390. ISO 11600 applies only to sealants used in vertical joints, i.e. non-slump products. This does not prevent the specifier from asking for a self levelling version of a particular ISO 11600 class sealant. The supplier will have to carry out a suitable test for self levelling. Introduction Until 1993 there was no UK system of classification for the sealants used in construction and glazing. Sealants were specified using the standards for polysulfide and silicone sealants, including sealants of other chemical types. Nowhere in these standards was there a method to determine the movement capability of a sealant. Earlier attempts to introduce a classification scheme for sealants were unsuccessful and so in 1993 BSI adopted the newly published ISO 11600, Building construction - Sealants - Classification and requirements. The associated methods of test were also adopted, including a method which enables the producer to obtain a measure of the movement capability of a sealant. For a number of reasons, including the absence of promotion, BS ISO 11600 :1993 was not widely used and the old generic standards prevailed. With the issue of an improved version and its adoption by Europe as a CEN standard, ISO 11600 is the recommended choice for the selection of sealants across the EU. However, it is because it works and is easy to apply that makes ISO 11600 acceptable to the industry. It allows the architect to describe the sealant for the designed joint by the use of some basic parameters (movement capability, elasticity and modulus) without the need to understand the underlying chemistry of the available products. Once the basic description is in place, the final choice of sealant is a cooperative process involving the sealant specifier and the sealant suppliers. 9 iii) Loss of volume and mass. Test method: BS EN ISO 10563 There is a test for loss of volume and mass aimed primarily at water based and solvent based sealants. iv) Adhesion ISO 11600 looks at one of the key performance properties of sealants: adhesion. In testing for recovery and movement capability, the sealant is examined for loss of adhesion. There are tests which specifically look for the adhesive strength of the bond between sealant and substrate under a variety of conditions, such as after water immersion (BS EN ISO 10590) or after exposure to UV light, heat and water (BS EN ISO 11431). Thus, in specifying a sealant using ISO 11600 the specifier can be confident there is no serious weakness in the adhesion of the sealant (primer) system. However, further assurances should be sought from the supplier, backed by case histories, that the long term adhesion of the system is also proven. In particular clear reference should be made to the adhesion of the particular grade of sealant to the specific substrates to be sealed 2

Part One: User Guide The ISO 11600 Sealant Classes There are 11 classes of sealant covered by the current ISO 11600 classification scheme. Four describe glazing sealants (Type G) Seven describe construction sealants (Type F - standing for Facade) The 11 classes are: SEALANTS IN BUILDING AND CONSTRUCTION Glazing Sealants (G) Construction Sealants (F) Class 25 Class 25LM Class 25 Class 25LM Class 20 Class 20LM Class 20 Class 20HM Class 20HM Class 20LM recoveries, some with nearly 100% recovery. For fast cyclic movement the specifier should consider the highly elastic products. Sealants with elastic recovery of less than 40% are classified as plastic (suffix P). Only the lower movement capability sealants carry this suffix. In ISO 11600 much emphasis is placed on the elasticity of sealants. Whilst this is an important property for rapidly moving joints, it is not essential in all joints, for example joints which move once and are then subject only to small daily and seasonal thermally induced movement. These situations are often better served by the stress relaxing, elastoplastic sealants, a category not considered by ISO 11600. Specifiers should bear this in mind when considering their requirements Movement capability Test Methods: BS EN ISO 9046 and BS EN ISO 9047 In most sealant selection processes, movement capability is the key parameter, and so it is in ISO 11600. It is determined by subjecting the sealant to cycles of extension and compression. Elastic sealants are cycled through extension at -20 C and compression at 70 C to various amplitudes. Sealants classified as plastic (P) are cycled through extension and compression at various amplitudes, but at room temperature only. The highest amplitude of the extension and compression that the sealant can survive under these test conditions is the Movement Capability of that sealant. In ISO 11600 the highest classification for movement capability an elastic sealant can claim is 25%, i.e. it survives intact having been tested at an amplitude of extension and compression of 25%. In reality there are many commercial sealants capable of obtaining a higher rating (e.g. 37.5% or 50%) and BS EN ISO 9047 can be used to determine a sealant s ability to achieve these higher movement capabilities. Class 12,5 Class 12,5E Class 12,5P Class 7,5 Class 7,5P In all classes the number refers to the movement capability. The higher movement capability sealants (classes 25 and 20) are by definition elastic in their characteristics. The suffix E (for elastic) is only used with the class 12,5E sealants in order to distinguish them from products with little or no elastic characteristics, 12,5P (plastic) sealants. Test method: BS EN ISO 8339 3 8 There are no elastic sealants in the 7,5 class. The higher movement capability sealants are subdivided by modulus, being either low modulus(lm)or high modulus(hm) However, the ISO sealant Committee took the decision to put the official upper limit for movement capability, for the time being, at 25%. The reason for this decision was one of caution. If sealants with higher movement capability are specified to seal narrow joints, then the margin for error is reduced and undue pressure is put on the builder to meet accurate tolerances in building components and construction. In addition, unless the sealant supplier can claim with confidence that the movement capability for the specified sealant will remain more or less unchanged throughout the claimed life expectancy of the sealant, it is better to build a margin for change in to the sealant/joint design. In future revisions, as experience and confidence in the ISO sealant classification scheme grows, it is anticipated these higher classes will be formally recognised. The modulus of the sealant loosely equates with the cured hardness. In ISO 11600, the modulus is the force required to extend a sealant by a fixed amount, e.g. 100%. This is known as the tensile modulus. The units are newtons (N) per mm 2. A sealant

Part Two: Detailed description of the parameters used in determining the classification of a sealant according to ISO 11600 End Use (Type) Sealants are separated into two categories by end use: Type G Type F Sealants for use in glazing, for example sealing glass into window frames. Sealants for use in building construction joints other than glazing, i.e. sealants designed for high movement joints, low movement joints, joints subject to cyclical movement, joints subject to one off movement, joints between the same or different substrates. Many of the tests and requirements are similar for each of the two types. The ISO 11600 Designation In the sealant selection process the specifier matches his requirements to the products available on the market. Sealants classified using the ISO 11600 scheme are described in the producers technical literature and on packaging labels using a designation which indicates the following: END USE - construction (F) or glazing (G) MOVEMENT CAPABILITY - in the range 7.5% to 25% MODULUS - high (HM) or low (LM) as defined in ISO 11600 ELASTICITY - elastic (E) or plastic (P) In addition, the types of SUBSTRATES used in the testing of the sealant are clearly shown and if a PRIMER or surface conditioner was used on those test substrates. This allows the specifier and end user to judge whether the substrates used in the testing were representative of the materials making up the actual joint to be sealed. There are three standard substrates used in ISO sealant testing, mortar, glass and anodised aluminium, but the specifier can request all tests (or specific ones) be carried out on the actual substrate materials to be sealed. However, only the higher movement class sealants are specified for glazing. Plastic sealants, and elastic sealants with low movement capability, are excluded from the Type G classes. Also, Type G sealants are subjected to a relatively short, but rigorous UV-water test (BS EN ISO 11431), which would prove difficult for a number of commercial glazing products of low performance and durability. The Type F sealants encompass a much wider range of sealant types, from highly elastic/ high movement capability products to those which are plastic with low movement capability. Thus, within the Type F class, there is plenty of scope for the specifiers and the sealant producers, encompassing as it does all the commercial types of sealant currently on the market. 1 Thus in trade literature and on labels a sealant will be designated in one of two ways: Sealant ISO 11600 TYPE Movement Capability or Test Substrates Primer(s) Used Example: Sealant used in glazing (glass into frames etc.) might carry the designation Sealant ISO 11600 - G -20HM - glass, anodised aluminium Test method: BS EN ISO 7389 7 As a prelude to determining the movement capability, the elastic recovery of the sealant is determined. In this test the sealant is extended by 100% or 60% and held in this extended position for 24 hours. It is then released from extension and allowed to recover naturally. It is in the nature of polymer based compositions that most products will not totally recover their original dimensions. The degree to which they do is called elastic recovery. A sealant s elasticity determines its ability to perform in a continuously moving joint. Sealants with an elastic recovery greater than or equal to 40% are classified as elastic (suffix E), but for the highest classes the elastic recovery has to be greater than 70%. Within these higher classes there will be sealant products with a range of elastic 2 Sealant ISO 11600 TYPE Movement Capability or Tested on Substrates (using Primer(s)) Example: Sealants for use in fast moving joints in vertical structures might carry the designation Sealant ISO 11600 - F - 25LM Tested on mortar (primed), anodised aluminium, glass 4

How to use ISO 11600 The specifier considers the parameters given in the sealant designation: F Class or G class If the end use is to seal a joint in construction, for example between panels in a facade, in a brickwork wall, etc., the selection of the sealant will be from the F Classes. If the sealant is for glazing, the selection will be from the G Classes. Movement capability For joints in building construction (F) the specifier calculates the maximum amount of movement the designed joint will experience in its application, as a percentage of the minimum width the joint will obtain. A knowledge of the materials forming the joint, the maximum and minimum temperatures expected and other prevailing environmental conditions at the construction site is required. Standard calculations are used, for example as illustrated in BS 6093 and BS 6213. The specifier must next make a decision about the modulus of the sealant. is related to hardness, the higher the modulus, the harder the sealant. In general low modulus sealants are preferred, especially in moving joints. When a low modulus sealant is extended it puts less stress on the substrate and on the adhesion bond line than a high modulus sealant. This may be important if the substrate materials are weak and/or friable and for the long term durability of the adhesion. At low temperatures the modulus of a sealant can increase dramatically. ISO 11600 defines a low modulus sealant as one which remains low modulus at temperatures down to - 20 C. This is a good reason to specify low modulus sealants in colder climates. In some circumstances a harder, high modulus sealant can offer protection against outside factors such as abrasion, foot traffic or vandalism and may, therefore, be the preferred choice. If a high modulus sealant is selected for a moving joint it is important to ensure the sealant has adequate movement capability and that the substrate materials are strong enough to accept it. For moving joints the elastic sealant classes will be selected (25, 20 or 12,5E). For low movement or non-movement joints the plastic sealants could be selected (12,5P or 7,5P). Cost consideration might exclude truly elastic sealants from being specified for low movement joints, although there may be other factors which offset cost. For glazing (G) the specifier can choose a Class 25 or a Class 20 sealant, i.e. elastic sealants are always specified. The final choice will depend on the substrates other than glass (for example metal, plastic, wood etc.), the geometry and the dimensions of the sealant section. Narrow joints will probably require the higher of the two classes. Specifier s Sealant Designation Having determined the requirements for movement capability, elasticity and modulus, the specifier can now write down most of the ISO 11600 designation for the sealant for example: Other Sealant Requirements Sealant ISO 11600 - F - 25LM or Sealant ISO 11600 - G - 25HM or Sealant ISO 11600 - F - 7,5P What happens if the joint design indicates movement will exceed 25%? In principle there is no ISO 11600 class of sealant available (see Part Two - Movement Capability). A sealant producer may offer a sealant with a movement capability exceeding 25%, measured using the test method prescribed by ISO 11600. However, the ISO designation cannot be used to describe this sealant and the specifier should seek further assurance from the supplier with regard to its long term performance if selected for the joint. In the case of cyclic movement, lightweight materials (metals and plastics) will move rapidly. Here the elasticity of the sealant is an important property and a Class 25 sealant may be selected. Although the Class 25 and Class 20 sealants are elastic by definition, sealants within these classes have different levels of elasticity. For fast moving joints, a highly elastic sealant is preferred and advice should be sought from the supplier. The specifier must now prepare a checklist of the other requirements of the application. Typical items might be: life expectancy colour adhesion (list all substrates) non-staining non-slump fire resistance stress relaxation potential site problems with regard to access, etc. resistance to - list specific potential stress factors associated with the joint: fast movement, movement during cure, water, chemicals, abrasion, traffic etc. Using your Sealant Supplier 5 Heavier components, such as concrete cladding panels, will probably move more slowly due to inertial factors. Thus, a sealant with a lower level of elasticity might be selected, for example a Class 12,5E. ISO 11600 does not consider stress relaxation in sealants, an advantageous property in certain situations. The designer should ask the sealant producer for guidance. THE FINAL SELECTION PROCESS CAN NOW BEGIN AS A CO-OPERATIVE EFFORT BETWEEN THE SPECIFIER AND THE SEALANT SUPPLIER. The specifier should approach their sealant suppliers as soon as the ISO 11600 designation and specific requirements have been defined. A list of sealant manufacturers who are members of BASA is available from the BASA secretary. 6