OVER 45 YEARS TEXTILE GRAFT TECHNOLOGY EXPERIENCE MAQUET THE GOLD STANDARD



Similar documents
INTERGARD SYNERGY The Next Generation Antimicrobial Graft

Scout Vessel Guard. A cover for vessels during anterior lumbar spine surgery.

Innovation for optimized outcomes

Sutures and needles. Sutures

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES

CEA: What is the current best patch if any? EAC: Quel est le meilleur patch (s il existe)? Alan Dardik, MD, PhD, FACS Yale University New Haven, USA

CorMatrix ECM Technology

Tissue Reinforcement Solutions

Bard * PerFix * Plug. Technique Guide. A Modified Technique with the. Open Inguinal Hernia Repair

Ventral Hernia Repair

I.- FLAT MESHES FOR INGUINAL AND VENTRAL HERNIA REPAIR

Cranial/Neurosurgical Implants

A Patient s Guide to Minimally Invasive Abdominal Aortic Aneurysm Repair

Get the Facts, Be Informed, Make YOUR Best Decision. Pelvic Organ Prolapse

HUNTER TENDON IMPLANTS

Basic Wound Closure & Knot Tying. Joslyn Albright, MD General Surgery PGY-4 Research Resident

ONSTEP Technique. Technique Guide * Anterior Approach to a Part Preperitoneal, Part Intramuscular Inguinal Hernia Repair

Rotator Cuff Repair Surgical Procedures

ATRAUMATIC NEEDLES NEEDLE PROFILE ROUND BODIED TAPER POINT T. CAR POINT BLUNT CUTTING REVERSE CUTTING NEEDLE SHAPE. Straight. 3/8 Circle.

Patient Information Booklet. Endovascular Stent Grafts: A Treatment for Abdominal Aortic Aneurysms

X-Plain Inguinal Hernia Repair Reference Summary

QUADROX-i Small Adult and Adult Choose maximum safety.

SUTURE MATERIALS EDITION For quality & safety.

Scout Vessel Guard. A hydrogel membrane with exceptional handling characteristics.

Laparoscopic Repair of Hernias. A simple guide to help answer your questions

Titanized Mesh Implants Hernia Surgery

Arizona State University Institutional Animal Care and Use Committee STANDARD INSTITUTIONAL GUIDELINE RODENT SURGERY

Open Ventral Hernia Repair

(English) NEXUS SPINE SPACER SYSTEM

Science behind it. Life ahead of it. Transabdominal Pelvic Floor Restoration

HLS Set Advanced Integration meets innovation

M O V I N G F R E E LY. HerniaCenter. The Columbia Hernia Center at ColumbiaDoctors Midtown

LEADING THE FUTURE OF FIXATION

Antiplatelet and anticoagulation treatment of patients undergoing carotid and peripheral artery angioplasty

Recurrent Varicose Veins

Lentur Cable System. Surgical Technique

Plantar Fascia Release

XCM Biologic Tissue Matrix. Regenerative matrix for reinforcement and repair of soft tissue.

41 Assisting with Minor Surgery

Vascular Surgery: Workforce Needs and Career Choices

ANTERIOR LUMBAR INTERBODY FUSION (ALIF) Basic Anatomical Landmarks: Anterior Lumbar Spine

3M Steri-Strip S Surgical Skin Closure. Commonly Asked Questions

CONDITIONS REQUIRING IsolveTEM

IMPLANT MENTOR EFFECTIVE JANUARY 2012 BREAST IMPLANTS NOT FOR DISTRIBUTION IN USA APPROVED FOR EMEA REGION. Mentor Worldwide LLC Rev C

Biomaterials: Production, Processing and Application

KNEE LIGAMENT REPAIR AND RECONSTRUCTION INFORMED CONSENT INFORMATION

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

Instructions for Use

C A R O L I N A S. Hernia Handbook ( C H A P T E R 2 ) B. Todd Heniford, MD

PHaSES: Practical Hands-on Surgical Education System

PERCUTANEOUS PD CATHETER IMPLANTATION SYSTEM

UNMH Cardiothoracic Surgery Clinical Privileges

Chapter 33. Nerve Physiology

Biodesign. Ventral Hernia Repair Best Outcomes. Procedural Guide

IVALON Ophthalmic. IVALON Ophthalmic Products

Don t Let Life Pass You By Because Of Oral Bone Loss

TREATMENT OF VARICOSE VEINS: CAN IT BE IMPROVED BY MECHANOCHEMICAL ABLATION USING THE CLARIVEIN DEVICE?

ADMEDUS INVESTOR PRESENTATION ASX:AHZ. March,

Clinical Guideline for: Aseptic Technique

Renal Vascular Access Having a Fistula For Haemodialysis

chronos BOne VOid Filler Beta-Tricalcium Phosphate (b-tcp) bone graft substitute

Vaxcel PICCs Valved and Non-Valved. A Patient s Guide

Contents. 1. Milestones in Hernia Surgery Surgical Anatomy of Hernia Sites Incidence, Prevalence of Hernia 32

Medical Silicone Tubing & Hose

1. ENDOHOLDER for use with ENDONEEDLES and ENDOLOOPS 2. ENDONEEDLE 3. ENDOLOOP

X-Plain Abdominal Aortic Aneurysm Vascular Surgery Reference Summary

Laparoscopic Hernia Repair. Hernia Repair. Laparoscopic Ventral. Several Different Types of Hernia

Plasmax Plasma Concentration System for Laparoscopic Roux-en-Y Gastric Bypass

Extracorporeal life support PLS System

OPEN TENSION FREE REPAIR OF INGUINAL HERNIAS; THE LICHTENSTEIN TECHNIQUE

Titanium Wire with Barb and Needle. For canthal tendon procedures.

MANITOBA PATIENT SERVICE CENTRE STANDARDS

How To Use Floseal For Spinal Surgery

ARTHROSCOPIC HIP SURGERY

Product Reference Guide

Haemostasis in Spine Surgery with FLOSEAL Hemostatic Matrix

Title of Presentation Arial Regular 38pt

and MAXON TM CV synthetic absorbable sutures are prepared from polyglyconate, a copolymer of glycolic acid and trimethylene carbonate.

Chapter 11. Everting skin edges

Endoscopic Plantar Fasciotomy

.org. Rotator Cuff Tears: Surgical Treatment Options. When Rotator Cuff Surgery is Recommended. Surgical Repair Options

Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

INFORMATION FOR PATIENTS CONSIDERING LAPAROSCOPIC INGUINAL HERNIA REPAIR

ABThera Open Abdomen Negative Pressure Therapy for Active Abdominal Therapy. Case Series

Abdominal Pedicle Flaps To The Hand And Forearm John C. Kelleher M.D., F.A.C.S.

Consumer summary Minimally invasive techniques for the relief of stress urinary incontinence

Suffering from varicose veins? Patient Information. ELVeS Radial Minimally invasive laser therapy of venous insufficiency

BIOHAZARDOUS/MEDICAL WASTE MANAGEMENT PLAN

Selection & Use of Surgical Needles

Captivator II. Single-Use Snares

SUCTION & TUBING YANKAUER, POOLE, FRAZIER AND SIGMOID INSTRUMENTS PREMIUM CONNECTORED AND ECONOMY ROLL TUBING

Descemet s Stripping Endothelial Keratoplasty (DSEK)

Aspira* Peritoneal Drainage Catheter

Technique Guide. VersiTomic. Michael A. Rauh, MD. Anterior Cruciate Ligament Reconstruction

PARIETEX MESH CLINICAL STUDIES COMPENDIUM

IACUC Policy on Survival Rodent Surgery

Are mesh anchoring sutures necessary in ventral hernioplasty? Multicenter study

Talent Thoracic Stent Graft with THE Xcelerant Delivery System. Expanding the Indications for TEVAR

B. Braun Sutures Safil

Transcription:

OVER 45 YEARS TEXTILE GRAFT TECHNOLOGY EXPERIENCE MAQUET THE GOLD STANDARD A comprehensive, proven vascular graft portfolio and exceptional professional support make MAQUET Cardiovascular a valuable asset to cardiac, thoracic and vascular surgeons and their teams. The HEMASHIELD Platinum Finesse Ultra-Thin Knitted Cardiovascular Patch is used for cardiac and vascular patch grafting. MAQUET offers convenient and innovative clinical solutions for cardiothoracic and abdominal aneurysms and peripheral vascular therapy options including a line of surgical fabrics, meshes and tapes designed for a range of different clinical applications. MAQUET strives to be the first choice to surgeons performing vascular repair procedures by providing products designed to help improve the lives of patients with specific vascular therapy needs. Trusted for over 20 years, MAQUET's HEMASHIELD Grafts are the most used, most studied vascular products available in the market today. More than 2 million HEMASHIELD grafts have been implanted worldwide, demonstrating clinical efficacy and improved patient outcomes. MAQUET The Gold Standard.

MAQUET Registered Trademark of MAQUET GmbH & Co. KG Copyright MAQUET Cardiovascular LLC or its affiliates. All rights reserved. 08/08. MAQUET Cardiovascular LLC 170 Baytech Drive San Jose, CA 95134 Phone: 1-888-880-2874 Fax: 1-888-899-2874 www.maquet.com Getinge Group is a leading global provider of equipment and systems that contribute to quality enhancement and cost efficiency within healthcare and life sciences. Equipment, service and technologies are supplied under the brands ArjoHuntleigh for patient handling and hygiene, disinfection, DVT prevention, medical beds, therapeutic surfaces and diagnostics, GETINGE for infection cotrol and prevention within healthcare and life science and MAQUET for Surgical Workplaces, Cardiovascular and Critical Care. LT7900270

EXPERIENCE MAKES A MATERIAL DIFFERENCE Hemashield Platinum Finesse Ultra-Thin Knitted Cardiovascular Patch Sealed to a Higher Standard. The Hemashield Platinum Finesse Patch promotes exceptional handling, hemostasis and healing during vascular or cardiac patching procedures. The Hemashield Patch is the most used fabric for carotid endarterectomy, providing reliable and safe performance. Proprietary Hemashield collagen impregnation: Provides an initial blood-tight seal, improved tissue ingrowth and excellent biocompatibility Delivers advanced hemostasis with low porosity (<5 ml/cm 2 /min)* Ultra-thin knitted fabric: Handles like a vein Provides excellent conformability to host vessel Facilitates easy suturing and smooth needle passage Tapered, pre-trimmed design: Minimizes trimming Improves procedural efficiency Proven safety: In a randomized trial with 195 patients, 30-day follow-up demonstrated similar clinical results to autogenous saphenous vein when used for carotid endarterectomy 1 Hemashield Platinum Finesse Ultra-Thin Knitted Cardiovascular Patch Hemashield Double Velour Fabric Proprietary Hemashield collagen impregnation: Designed to provide an initial blood-tight seal and enhance tissue ingrowth Exclusive double velour material offers exceptional handling and strength Choice of knitted or woven fabric construction provides an excellent match to the clinical demands of abdominal, peripheral and thoracic applications Hemashield Double Velour Fabric Trelex Natural Meshes Polyester Tape (Umbilical Tape) A unique knitted polypropylene mesh. These meshes offer the strength to provide excellent reinforcement of soft tissue and improved handling characteristics. Strong, tight braided. The polyester tape reduces risk of tissue trauma while promoting effective retraction.

INstructions for Use Hemashield Platinum Finesse ULTRA-THIN KNITTED CARDIOVASCULAR PATCH, HEMASHIELD double velour Fabrics Indications: HEMASHIELD Knitted Double Velour Fabric, HEMASHIELD Woven Double Velour Fabric and HEMASHIELD PLATINUM FINESSE Ultra- Thin, Knitted Cardiovascular Patch are indicated for cardiac and vascular patch grafting. The fabrics are also recommended for use in patients requiring systemic heparinization prior to, or during, surgery. The GUIDELINE stripe on the HEMASHIELD Knitted Double Velour Fabric and the HEMASHIELD PLATINUM FINESSE Ultra-Thin, Knitted Cardiovascular Patch indicates the direction of greatest tensile strength; the HEMASHIELD Woven Double Velour Fabric is equally strong in both directions. Contraindications: This prosthesis is not indicated for use in reconstruction of hernias or tissue deficiencies, or reconstruction or repair of passive biological membranes (such as dura mater, pericardium, or peritoneum) Warnings: 1. DO NOT PRECLOT. With HEMASHIELD fabrics, no preclotting is required. 2. STERILE DO NOT RESTERILIZE SINGLE USE ONLY. HEMASHIELD fabrics cannot be resterilized. 3. These fabrics should not be implanted in patients with a known sensitivity to products of bovine origin. Precautions: 1. If surgical technique requires use of instruments with the fabric, use atraumatic instruments. 2. It is suggested that only taper-point needles be used for suturing. Taper cut or other cutting needles may cut the graft fibers. 3. Avoid excessive tension on the fabric. 4. Cutting to proper size is essential. Use sharp surgical scissors to trim the HEMASHIELD Knitted Double Velour Fabric and the HEMASHIELD PLATINUM FINESSE Ultra-Thin, Knitted Cardiovascular Patch. 5. The HEMASHIELD Woven Double Velour fabric should be cut with a low temperature, disposable cautery (e.g., 900 F/ 500 C) to prevent raveling. Cardiovascular velour, knitted, woven Fabrics Indications: Velour Fabrics - For arterial and ventricular septal defects, patch grafting and patch repair of carotid endarterectomy. Knitted Fabrics - For arterial and ventricular septal defects, patch grafting. Woven Fabric - Outflow tract patch, thoracic aortoplasty, or whenever blood loss is a concern. TRELEX NATURAL Meshes Indications: TRELEX NATURAL Meshes are indicated to reinforce soft tissue where weakness exists, e.g. for repair of hernia and chest wall defects. Contraindications: None known. Warnings: 1. Fabrics contaminated with human body fluid from previous surgery should not be used. 2. Destroy any portion of a fabric which has been contaminated by body fluid. Do not attempt to wash and resterilize a contaminated fabric. Precautions: 1. Trim TRELEX NATURAL Meshes to the desired size using sharp sterile surgical scissors. 2. If sutures are used to secure the mesh in place, nonabsorbable, monofilament sutures are recommended. As with any textile construction, it is suggested that only taper point needles be used. The use of taper cut or other cutting needles may damage the textile fibers. 3. SINGLE USE ONLY. polyester tape (umbilical tape) Indications: Retraction of blood vessels, nerves, organs and ligaments. Contraindications: None known. Warnings: 1. SINGLE USE ONLY. 2. Fabrics contaminated with human body fluid from previous surgery should not be used. Destroy any portion of a fabric which has been contaminated by body fluid. Do not attempt to wash and resterilize a contaminated fabric. PRECAUTIONS: 1. It is suggested that only taper point needles be used for suturing, as taper cut or other cutting needles may cut the fabric fibers. To place an order, contact customer service at 888.272.1001 Contraindications: None known. Warnings: 1. SINGLE USE ONLY. 2. Fabrics contaminated with blood or bodily fluids from previous surgery cannot be reused or resterilized. Destroy any portion of a fabric which has been contaminated by blood or bodily fluids. Do not attempt to wash and resterilize a contaminated fabric. 3. All non-sealed Cardiovascular Fabrics, woven as well as knitted, must be preclotted or sealed to reduce their permeability to blood. Precautions: 1. It is suggested that only taper point needles be used for suturing, as taper cut or other cutting needles may cut the fabric fibers. * As compared to Hemashield Double Velour Fabrics (<10mL/cm 2 /min). Measurements and testing completed by Maquet Cardiovascular. Data on file. Bench test results may not necessarily be indicative of clinical performance. 1. O Hara PJ, Hertzer NR, Mascha EJ, et al. A prospective, randomized study of saphenous vein patching versus synthetic patching during carotid endarterectomy. J Vasc Surg. Feb 2002;35:324-332. N=195.

product information Hemashield Platinum Finesse Ultra-Thin Knitted Cardiovascular Patch (in) (cm) M00202019575P0 019575P 0.2 x 3 0.6 x 7.6 M00202019579P0 019579P 0.3 x 3 0.8 x 7.6 M00202019585P0 019585P 0.3 x 6 0.8 x 15.2 M00202019530P0* 019530P* 1 x 3 2.5 x 7.6 M00202019561P0* 019561P* 1 x 6 2.5 x 15.2 * Non-tapered End. Porosity: <5mL/cm 2 /min. Nominal Thickness: 0.36mm. Packaged 1 Per Box. The C-code used for this product is C1768, Vascular grafts. C-codes are used for hospital outpatient device reporting for Medicare and some private payers. Hemashield knitted Double Velour Fabric M002000195250* 019525* 0.2x3 0.6x7.6 M002000195280* 019528* 0.2x4.8 0.6x12.2 M002000195290* 019529* 0.3x3 0.8x7.6 M002000195100* 019510* 0.3x6 0.8x15.2 M002000195090 019509 0.3x3 0.8x7.6 M002000195140 019514 1x3 2.5x7.6 M002000195170 019517 1x6 2.5x15.2 M002000195240 019524 2x3 5.1x7.6 M002000195270 019527 2x6 5.1x15.2 * Tapered End Porosity: <10mL/cm 2 /min. Nominal Thickness: 0.76mm Note: Maquet Cardiovascular is not responsible for the correct use of codes on submitted claims; this information does not constitute reimbursement or legal advice. Hemashield woven Double Velour Fabric Trelex Natural Meshes M002000196170 019617 1x6 2.5x15.2 M002000196240 019624 2x3 5.1x7.6 M002000196270 019627 2x6 5.1x15.2 Rectangle M002000199101 019910 1x4 2.5x10.2 M002000199111 019911 1x24 2.5x61 M002000199201 019920 2x4 5.1x10.2 M002000199211* 019921* 2x12 5.1x30.5 M002000199301 019930 3x6 7.6x15.2 M002000199400** 019940** 10x14 25.4x35.6 Square M002000199601 019960 6x6 15.2x15.2 Pre-Shaped M002000199701 019970 1.8x4 4.6x10.2 Pre-Shaped with Opening M002000199711 019971 1.8x4 4.6x10.2 Large Pre-shaped M002000199721 019972 2.4x5.6 6.1x14.2 Large Pre-shaped with Opening M002000199731 019973 2.4x5.6 6.1x14.2 Nominal Thickness: 0.635mm Packaged 3 Per Box * Packaged 2 Per Box ** Packaged 1 Per Box Porosity: <10mL/cm 2 /min.; Nominal Thickness: 0.46mm All Hemashield Double Velour Fabrics Packaged 1 Per Box Polyester Tape (Umbilical Tape), Sterile Polyester Tape (Umbilical Tape), non-sterile (in x yd) (mm x m) M002000194000 019400 1/8x100 3.2x91.4 M002000194100 019410 3/16x100 4.8x91.4 M002000194200 019420 1/4x100 6.4x91.4 Packaged 1 Spool Per Box M002000194011 019401 1/8x18 0.32x45.7 M002000194021 019402 1/8x24 0.32x61.0 M002000194031 019403 1/8x30 0.32x76.2 M002000194111 019411 3/16x18 0.48x45.7 M002000194121 019412 3/16x24 0.48x61.0 M002000194131 019413 3/16x30 0.48x76.2 M002000194211 019421 1/4x18 0.64x45.7 M002000194221 019422 1/4x24 0.64x61.0 M002000194231 019423 1/4x30 0.64x76.2 Packaged 2 Strips Per Package; 5 Packages Per Box