POLYDIMETHYLSILOXANE



Similar documents
SODIUM CARBOXYMETHYL CELLULOSE

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

ß-CYCLODEXTRIN SYNONYMS

HEXANES. Insoluble in water, soluble in ether, alcohol, and acetone. Neutral to methyl orange (ph indicator) Not more than 0.

MINERAL OIL (MEDIUM VISCOSITY)

TANNIC ACID. SYNONYMS Tannins (food grade), gallotannic acid, INS No. 181 DEFINITION DESCRIPTION

SUCRALOSE. White to off-white, practically odourless crystalline powder

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

PECTINS. SYNONYMS INS No. 440 DEFINITION DESCRIPTION. FUNCTIONAL USES Gelling agent, thickener, stabilizer, emulsifier CHARACTERISTICS

CHEM 2423 Recrystallization of Benzoic Acid EXPERIMENT 4 - Purification - Recrystallization of Benzoic acid

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

NITRIC OXIDE and NITROGEN DIOXIDE 6014

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

Standard Test Method for Water in Petroleum Products and Bituminous Materials by Distillation 1

1. The Determination of Boiling Point

Standard Test Method for Kinematic Viscosity of Asphalts (Bitumens) 1

Esterification Method 1 Method to 2800 mg/l (as acetic acid) Reagent Solution

Apparatus error for each piece of equipment = 100 x margin of error quantity measured

Color, True and Apparent

ISOLATION OF CAFFEINE FROM TEA

Color, True and Apparent

Molar Mass of Polyvinyl Alcohol by Viscosity

Determination of Molar Mass by Boiling Point Elevation of Urea Solution

A H M 531 Penetration & Ring & Ball & Ductility & Flash & Fire point By: Mu'men Al-Otoom

Coordination Compounds with Copper (II) Prelab (Week 2)

experiment5 Understanding and applying the concept of limiting reagents. Learning how to perform a vacuum filtration.

Hands-On Labs SM-1 Lab Manual

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

EUDRAGIT E 100, EUDRAGIT E PO and

Synthesis of Isopentyl Acetate

Physical Properties of a Pure Substance, Water

INTERNATIONAL OLIVE COUNCIL

SYNTHESIS AND ANALYSIS OF A COORDINATION COMPOUND OF COPPER

Chem 131A: Absorbance of Riboflavin

Calibration of Volumetric Glassware

Standard Test Methods for Determination of Solution Viscosities of Polyamide (PA) 1, 2

Standard Test Method for Analysis of Barium, Calcium, Magnesium, and Zinc in Unused Lubricating Oils by Atomic Absorption Spectrometry 1

HS 1003 Part 2 HS 1003 Heavy Metals Test

CHAPTER 2: LIQUID VISCOSITY MEASUREMENT

Lab #11: Determination of a Chemical Equilibrium Constant

Melting Point, Boiling Point, and Index of Refraction

HiPer Total RNA Extraction Teaching Kit

PART I SIEVE ANALYSIS OF MATERIAL RETAINED ON THE 425 M (NO. 40) SIEVE

Tamsulosin Hydrochloride Capsules

Isolation of Caffeine from Tea

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

MOLECULAR WEIGHT BY BOILING POINT ELEVATION

PREPARATION AND PROPERTIES OF A SOAP

CERTIFICATE OF ANALYSIS Methyl 4-Hydroxybenzoate

Measuring Protein Concentration through Absorption Spectrophotometry

Determining Equivalent Weight by Copper Electrolysis

Factors Affecting Enzyme Activity

To measure the solubility of a salt in water over a range of temperatures and to construct a graph representing the salt solubility.

Lab 2 Biochemistry. Learning Objectives. Introduction. Lipid Structure and Role in Food. The lab has the following learning objectives.

PHYSICAL SEPARATION TECHNIQUES. Introduction

PURIFICATION TECHNIQUES

Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law.

WATER EQUIVALENT OF THE CALORIMETER

COMMON LABORATORY APPARATUS

The Determination of an Equilibrium Constant

Separation by Solvent Extraction

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

105 Adopted:

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Basics of Laboratory Safety: Chem 5a Lab 2003

Experiment #10: Liquids, Liquid Mixtures and Solutions

EXPERIMENT 3 (Organic Chemistry II) Nitration of Aromatic Compounds: Preparation of methyl-m-nitrobenzoate

5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS

CHEM 2423 Extraction of Benzoic Acid EXPERIMENT 6 - Extraction Determination of Distribution Coefficient

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

Experiment 7: Titration of an Antacid

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

EXPERIMENT 4. Determination of Sodium by Flame Atomic-Emission Spectroscopy

Recrystallization II 23

Experiment 8 Preparation of Cyclohexanone by Hypochlorite Oxidation

METHOD 3510C SEPARATORY FUNNEL LIQUID-LIQUID EXTRACTION

5. Which temperature is equal to +20 K? 1) 253ºC 2) 293ºC 3) 253 C 4) 293 C

A Beer s Law Experiment

Spectrometry: Absorbance of Visible Light by a Food Colour Dye. by Professor David Cash. September, 2008

Chapter 2 Chemical and Physical Properties of Sulphur Dioxide and Sulphur Trioxide

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.

ETHYL LAUROYL ARGINATE

Determination of Melting Points

EXPERIMENT 4: IONIC AND COVALENT PROPERTIES

Asian Journal of Research in Biological and Pharmaceutical Sciences Journal home page:

THIN LAYER CHROMATOGRAPHY AND MELTING POINT DETERMINATION: DETECTION OF CAFFEINE IN VARIOUS SAMPLES

Catalase. ***You will be working with hot water, acids and bases in this laboratory*** ****Use Extreme Caution!!!****

SOLUBILITY, IONIC STRENGTH AND ACTIVITY COEFFICIENTS

EXPERIMENT 9 (Organic Chemistry II) Pahlavan - Cherif Synthesis of Aspirin - Esterification

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40

Compounds vs mixtures. Physics and Chemistry IES Jaume Salvador i Pedrol February 2009

TEACHER ACTIVITY GUIDE

QuickZyme Soluble Collagen Assay

ERDOSTEINE - MONOGRAPH.

Thermochemistry: Calorimetry and Hess s Law

Worked solutions to student book questions Chapter 7 Spectroscopy

Transcription:

POLYDIMETHYLSILOXANE Prepared at the 37th JECFA (1990), published in FNP 52 (1992) superseding specifications prepared at the 29th JECFA (1985), published in FNP 34 (1986). Metals and arsenic specifications revised at the 61st JECFA (2003). An ADI of 0-1.5 mg/kg bw was established at the 23rd JECFA (1979) SYNONYMS DEFINITION Poly(dimethylsiloxane), dimethylpolysiloxane, dimethylsilicone fluid, dimethylsilicone oil; INS No. 900 Consists of fully methylated linear siloxane polymers containing repeating units of the formula (CH 3 ) 2 SiO, with trimethylsiloxy end-blocking units of the formula (CH 3 ) 3 SiO- The article of commerce used as an antifoaming agent can be further specified as to total silicon Chemical names Simethicone (CAS name) C.A.S. number 8050-81-5 Structural formula The average value for n is 90 to 410 Formula weight Assay DESCRIPTION 6,800 to 30,000 (average and approximate) Silicon content not less than 37.3% and not more than 38.5% of the total Clear, colourless, viscous liquid. Polydimethylsiloxane is frequently used in commerce as such, as a liquid containing 4-5% silica gel, and as an aqueous emulsion formulation containing, in addition to silica gel, emulsifiers and preservatives. The pure substance described here can be isolated by centrifuging from the silica gel-containing liquid at about 20,000 rpm. FUNCTIONAL USES Antifoaming agent, anticaking agent CHARACTERISTICS IDENTIFICATION Solubility (Vol. 4) Insoluble in water and in ethanol; soluble in carbon tetrachloride, benzene, chloroform, diethyl ether, toluene and other organic solvents Specific gravity (Vol. 4) d (25, 25): 0.964-0.977

Refractive index (Vol. 4) n (25, D): 1.400-1.405 Infrared absorption The infrared spectrum of the sample corresponds with the reference infrared spectrum below. Prepare two solutions containing: (1) 10% of sample in carbon tetrachloride and (2) 2% of sample in carbon disulfide. Obtain the infrared spectrum for the sample using the carbon disulfide solution (2) from 1300 to 650 cm - 1. The solvent in the reference cell is also changed at the appropriate wave numbers to correspond to the sample solution. PURITY Loss on drying (Vol. 4) Not more than 0.5% (150 o, 4 h) Viscosity Lead (Vol. 4) 100-1500 cst at 25 o See description under TESTS Not more than 1 mg/kg Determine using an atomic absorption technique appropriate to the specified level. The selection of sample size and method of sample preparation may be based on the principles of the method described in Volume 4, Instrumental Methods. TESTS PURITY TESTS Viscosity Apparatus: The Ubbelohde suspended level viscometer, shown in the accompanying diagram, is preferred for the determination of the viscosity. Figure: Ubbelohde Viscometer for Polydimethylsiloxane (all dimensions are in millimeters) For use in the range of 100 to 1.500 centistokes, a No. 3 size viscometer,

having a capillary diameter of 2.00 + 0.04 mm, is required. The viscometer should be fitted with holders which satisfy the dimensional positions of the separate tubes as shown in the diagram, and which hold the viscometer vertical. Filling lines in bulb A indicate the minimum and maximum volumes of liquid to be used for convenient operation. The volume of bulb B is approximately 5 ml. Calibration of the Viscometer Determine the viscosity constant C for each viscometer by using an oil of known viscosity. Charge the viscometer by tilting the instrument about 30 degrees from the vertical, with bulb A below the capillary, and then introduce enough of the sample into tube 1 to bring the level up to the lower filling line. The level should not be above the upper filling line when the viscometer is returned to the vertical position and the sample has drained from tube 1. Charge the viscometer in such a manner that the U-tube at the bottom fills completely without trapping air. After the viscometer has been in a constant-temperature bath long enough for the sample to reach temperature equilibrium, place a finger over tube 3 and apply suction to tube 2 until the liquid reaches the center of bulb C. Remove suction from tube 2, then remove the finger from tube 3 and place it over tube 2 until the sample drops away from the lower end of the capillary. Remove the finger from tube 2, and measure the time, to the nearest 0.1 sec required for the meniscus to pass from the first time mark (T 1 ) to the second (T 2 ). In order to obtain accurate results within a reasonable time, the apparatus should be adjusted to give an elapsed time of from 80 to 100 sec. Calculate the viscometer constant C by the equation, C = cs/t 1, in which cs is the viscosity, in centistokes, and t 1 is the efflux time, in sec for the standard liquid. METHOD OF ASSAY Principle Silicon in the sample is converted to a soluble form by fusion with sodium peroxide. Soluble silicon is measured in the percent range as total silicon by atomic absorption spectrometry. Apparatus - Apparatus for fusion: a Parr-type fusion cup and nickel beaker, or equivalent (avoid use of glassware during fusion and solubilization). - Instrument: atomic absorption spectrometer with silicon hollow cathode lamp; nitrous oxide - acetylene burner, or equivalent. Reagents - Sodium peroxide, glacial acetic acid, silica (of known purity for use as standard). Procedure NOTE: Normal safe laboratory practices for Parr-type bomb fusion should be followed.

Equivalent fusions must be performed on sample(s), reagent blank(s) and silica standards for each series of samples. For each sample weigh a portion (W) not to exceed 0.3 g into a Parr-type fusion cup (use gelatin capsules for liquid samples). Add 15.0±0.5 g sodium peroxide. Assemble the fusion apparatus and place it in a protective ignition rack. Fill the cavity above the cap with water and keep it full during ignition to prevent the gasket from melting. Heat the bottom of the cup with a blast lamp until the cup is cherry red about 100 mm up from the bottom within 90 sec. Quench the apparatus in ice water and disassemble the apparatus. Place the cup in a 500 ml nickel beaker containing 150 to 200 ml of distilled water. Rinse any material adhering to the inside of the assembly cap into the beaker with distilled water. Cover the beaker with a nickel lid. When the solution is complete and cooled, remove the cup from the beaker and rinse with distilled water into the beaker. Add 55.0 ml of reagent grade glacial acetic acid to the beaker. Cool the solution to room temperature and transfer to a 500 ml volumetric flask. Dilute to volume with distilled water. The solution should contain about 100 µg silicon/ml for a sample weight of about 0.13 g. This method performs best if the silicon concentration of the final analysis solution is 1 to 200 µg/ml. Prepare a series of standards, using the same fusion technique, which bracket the sample. Adjust the spectrophotometer according to operating instructions to obtain optimum analysis conditions for: maximum lamp output when monochrometer is at 251.6 nm, fuel and oxidant flow rate to burner (or equivalent procedures for other vaporizing techniques). Adjust zero absorbance while aspirating the solvent blank used to dilute the samples. Measure the absorbance of sample(s), reagent blank and standards. Estimate the concentration (C) of silicon in the sample solution from the standards, correcting for the reagent blank. Calculate percent total silicon in the sample by the formula where C = the silicon concentration of the sample solution (µg/ml) W = the weight of sample taken (g) Infrared spectrum Polydimethylsiloxane