BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW



Similar documents
STEALTH I DC MANUAL TECH SUPPORT WEB BLACK UNIT IS 24/36 ONLY

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

12 Volt 30 Amp Digital Solar Charge Controller

Mobile Data Power Model: MDP-25

TROUBLESHOOTING GUIDE

Installation and Operating Instructions (for chargers shown below)

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

HM-W536 Install Guide

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

How To Use A Power Supply Unit (Upu)

OUTPUT CABLE CONNECTIONS:

400 Amp Rechargeable Jump Start System RAC-HP082

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

CHARGING SYSTEMS INTERNATIONAL

Cabela's Advanced Angler Prosport II Chargers. Set Number SKU

13 Watt PORTABLE SOLAR POWER KIT

SPECIFICATIONS. Recommended Battery sizes (Maintenance) AUTOMOTIVE CCA CCA MARINE MCA MCA DEEP CYCLE 17 55Ah 17 80Ah

Owner's Manual and Installation Guide

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

ST Series POWER SUPPLIES USER INSTRUCTIONS

Installation and Operating Instructions (for chargers shown below)

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

APOLLO Gate Operators, Inc.

BATTERY CHARGER OWNER S MANUAL

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

GEN Series. On-Board Battery Chargers. Owner s Manual & User Guide

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Owner's Manual and Installation Guide

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

3000W Power Inverter

INSTALLATION AND OPERATION MANUAL

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Installation and Operation Guide for PD4000 Series Power Control Center

Installation Instructions for Alarm Module Kit A043F059

Companion Service Guide

ProTournament Series. Owner's Manual and Installation Guide. ProMariner. ProMariner. Professional Grade 3 Step Marine Battery Chargers WATERPROOF

Battery Chargers. Revised 8/00 Form Number FORM NO / BATTERY CHARGER SERVICE MANUAL / PARTS LIST - 45

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

Hand Crank Generator (9 May 05) Converting a Portable Cordless Drill to a Hand Crank DC Generator

Battery Backup Sump Pump System

Installation and Operation Guide for PD4100 Series Power Control Centers

Air-cooled Generator Battery Charger Installation Guidelines

MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel

POWER TO GET THE JOB DONE

Battery Power Inverters

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

TruPower-Portable-500W. Solar Starter kit

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

If you accidentally get battery acid on your skin, flush it with lots of water

Operating Instructions

Manual Ranging MultiMeter

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Networkfleet 3500 Product Line Installation Guide

Charge Regulator SCR 12 Marine

Manual. Solar Fountain Mobile Phone Charger

Self Monitoring Power Supply (BPSM)

User s Manual AURORA 1.2K/2.2K

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

3 WATT LED SPOTLIGHT Model No. SLM

Solar Controller / Battery Charger User s Manual

Battery Backup Sump Pump System

Battery Backup Sump Pump System

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

Online UPS. PowerWalker VFI 1000R/1U

Model 201 Wiegand Touchpad Reader Installation Guide

R02GA. July 31, Dear Blue Bird Owner:

PUSH BUTTON START INSTALLATION MANUAL

TOOL SVC NUMBERS: , SVC CONTENTS ITEM QTY DESCRIPTION PART NUMBER 1 1 CUTTING TOOL EXTRACTION TOOL/PART#

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

Part Number:

SCHWINTEK IN-WALL SLIDEOUT TROUBLESHOOTING AND COMPONENT REPLACEMENT

70-Series CAN Power Management System

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Portable Solar Kits Owner s Manual

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

Operating Instructions

VLT Series 300 Watt True Sine Wave Inverter

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

2003/2004/2005 TOYOTA COROLLA

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

BATTERY CHARGER MULTI US 7000

Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

Fan Coil EC Motor Control


Transcription:

WARNING CARTON INVENTORY CAUTION with: Charger, Cable 15', Fuses (2), Battery Strap and Strain Relief (2) Model SOLBBOX 12V Battery Not Included AVERTISSEMENT ATTENTION DC Power Adapter 12Vdc to 32Vdc Model K76-33847 NOTE: Solar panel is not provided. A 20W 12V solar panel is recommended. BATTERY BOX INSTALLATION WARNING WARNING SOLBBOX12V To reduce the risk of fire and the risk of SEVERE INJURY or DEATH to persons: Disconnect electrical power to operator BEFORE proceeding. Disconnect battery power internal to operator. DO NOT dispose of the battery in fire. The cells may explode. Check with local codes for disposal instructions. DO NOT open or mutilate the battery. Released electrolytes are corrosive and may cause damage to the eyes or skin. It may be toxic if swallowed. Exercise care in handling batteries in order not to short the battery with conducting materials such as rings, bracelets and keys. AVERTISSEMENT Change the battery provided with one identified for use with this product ONLY in accordance with the instructions and limitations specified in the manual. Observe proper AVERTISSEMENT polarity orientation between the battery and charging circuit. DO NOT mix batteries of different sizes or from different manufactures in this product. COMPLETED OVERVIEW NOTE: Image is for reference only, your operator and control box may appear different. Solar Panel (Facing South) Cable from Solar Panel to ADVERTENCIA PRECAUCIÓN Control Box ADVERTENCIA ADVERTENCIA Battery Box Cable from Battery Box to Control Box Cable Control Arm to Control Box

40-50399A PREPARATION This kit is not intended to replace or eliminate the need for the primary batteries provided with the operator. Primary batteries are REQUIRED to operate the gate. Both the primary and external batteries must be fully charged prior to installation. It is strongly recommended that new batteries are used for solar applications. Verify kit contents. You will need to purchase a UL recognized, sealed leadacid (SLA) battery (not included) or a marine deep cycle battery. See Suggested Batteries. NOTE: Automotive batteries are not acceptable. Suggested Batteries MFG PART NO. SPECIFICATIONS Jolt XSA12800B 12V, 80AH Werker WKA12-80C/FR 12V, 80AH Universal UB12750 12V, 75AH PowerSonic PS-12750 12V, 75AH Genesis NP75-12 12V, 77.5AH Potential sources: www.batterygiant.com www.apexbattery.com www.batteriesplus.com INSTALL BATTERY BOX Location The battery box must be located within 10' of the operator control box. The box must be located in a place where it cannot be damaged due to flooding, excessive contact or by being knocked over. Place battery box either on the ground or a stable platform (not provided). NOTE: Image is for reference only, your operator and control box may appear different. Solar Panel SOUTH Cable to Control Box Cable to Control Box Battery Box 2

WIRING Open battery box. Remove and retain fuse in fuse holder. Route output cable and solar panel(s) cable as shown. Reminder, as soon as sunlight hits the solar panel(s) there will be electrical power at the leads. Leave the leads covered until ready to connect them. Extend output cable though strain relief leaving slack in the battery box, and tighten top strain relief. Attach red wire from solar cable to terminal 4 on solar controller and black wire to terminal 3. Tighten bottom strain relief. Attach and tighten the provided wire tie to both cables on the inside of the box. NOTE: If using a marine (flooded) battery, metallic jumper must be removed for proper charging. If using a sealed lead-acid (SLA) battery, leave jumper in place. 1 Panel Wiring 2 Panel Wiring Load Disconnect LED Charging LED Load Disconnect LED Charging LED Terminal 3 Terminal 4 Terminal 2 Terminal 1 CHARGING LOAD DISCONNECT Terminal 6 Terminal 5 Output Cable (To Control Box) Terminal 3 Terminal 4 Terminal 5 Terminal 6 CHARGING LOAD DISCONNECT Metallic Jumper Output Cable (To Control Box) RED Metallic Jumper RED WHITE WHITE ORANGE - Wire Tie Solar Panel Cable ORANGE - To Battery Wire Tie Solar Panel 1 Cable To Battery Solar Panel 2 Cable NOTE: Remove the battery and use a 3/4" drill bit to drill additional hole. Be careful not to hit any wires. Multiple Panels Overview When multiple panels are required, they must be wired in parallel to terminals 3 and 4 on the solar controller. Solar Panel (Facing South) Control Box Cable to Battery Box (Up to 200') Solar Panel (Facing South) 3

O N WIRE BATTERY BOX TO OPERATOR CONTROL BOX Install Power Adapter Open control box cover and disconnect primary operator batteries at the control board. Locate the 24Vac input on the control board. Attach the yellow and black wires to the 24Vac input terminal (polarity is not important). Insert the provided strain relief though one of the knockouts and thread the battery box output cable through strain relief in the control box. Attach black wire from the output cable to the black wire on the power adapter connector. Attach the white wire from the output cable to the red wire on the power adapter connector. Place power adapter inside of the control box. Power Adapter Red () Black (-) White J4 24 VAC/ SOLAR INPUT Control Board Black Black Output Cable (To Control Box) Yellow LA400 OFFF OFFF SINGLE NO NO S1 1 2 3 4 5 ON ON DUAL NC NC SAVE MAGLOCK MODE EDGE PHOTO NOTE: For the LA400 the SAVE switch (S1) must be in the ON position after all operator adjustments have been made. INSTALL BATTERY Wire Battery NOTE: Battery voltage must be above 12Vdc for proper operation. Install the 12V 75AH min. (fully charged) sealed lead-acid battery into the battery box. Connect the orange wire to the positive terminal on the battery. Insert the 5 amp fuse into the fuse holder. Connect the black wire to the negative terminal on the battery. Reminder, if using a deep cycle marine battery, the metallic jumper must be removed for proper charging. Battery Terminal 3 Terminal 4 Terminal 2 Terminal 1 CHARGING LOAD DISCONNECT Terminal 6 Terminal 5 Output Cable ORANGE BLACK _ Metallic Jumper Cable from Solar Panel To Battery COMPLETE INSTALLATION Reconnect internal batteries to the control board and ensure that all wires are secure. Close control box cover and battery box. Secure battery box with strap (provided) if desired. 4

CHARGING The Chamberlain Gate operator uses 2-12 volt 7amp hour batteries (24 volts) in the gate control box to keep the control board alive and arms functioning (in operation). These are referred to as the primary batteries. This battery kit is designed as a secondary DC power source for charging the primary batteries, not replacing the primaries. If the primary batteries are below operational voltage, attaching this secondary solar panel(s) kit will not immediately operate the gate operator, only after the secondary battery charging devise charges the primary batteries to an acceptable 24 volt level for operation prior to install. Recharging depleted batteries is a challenge for solar systems requiring full sun for extended periods, therefore it is recommended charging both primary and secondary batteries using an AC trickle charger and beginning with a fully charged system. It is assumed that the actual operator has been installed correctly and that its operation was verified before the installation of the solar kit, so that if there are any problems we can confine them to the solar operation. Solar systems are 100% dependent upon the amount of sun and direction of the solar panel(s) to maximize the battery charge. The system should be evaluated several times during the first month of operation to see if the external battery is being replenished by the solar panel(s). Also note that December in the US typically has the lowest amount of solar energy reaching the earth with June the maximum. If the battery voltage should continue to decrease, the system should be checked to see if the solar panel(s) is pointed properly, and if so an additional panel(s) may be required for this location. Obviously the number of operation cycles per day is another factor to be considered. In addition to the first month of use, the battery should be measured several times during the first year to make sure the lack of sun does not discharge the battery below 11.5 volts as an additional solar panel(s) may be required. To verify correct solar operation, review the following: IMPORTANT NOTE: For the LA400 to conserve battery voltage, the SAVE switch located inside the gate control box must be in the ON position so board goes to SLEEP mode (If SAVE switch is not turned to the on position, batteries will drain prematurely). With sun shining on the solar panel(s), the green charging LED on the solar controller in the battery box should be on, indicating that the panel(s) is supplying power to the battery. If the green LED is not illuminated check: Inside the gate control box, measure voltage across the yellow and black wires from the output of the power adapter. If the there is no voltage out of the power adapter. If the voltage output of the power adapter is less than 31 volts, but greater than 20. 1. Solar panel(s) connection at terminals 3 and 4 and polarity (See wiring diagram), and that no part of the solar panel(s) is in the shade. 2. The battery connections are secure and their polarity is correct. 3. Fuse F1 is good and installed. 1. If this voltage measures greater than 31 volts (yellow positive), installation is complete. 2. If voltage is less than 31Vdc, see Troubleshooting Procedures. 1. Verify 12-14Vdc on terminals 5 and 6 at the solar controller, verify voltage at both sides of the power adapter connector block (white positive). 2. Reverify the fuse is good. 1. Unplug connector on gate control board and reconnect. 2. If the voltage rises to 31Vdc, installation is complete. If not, the batteries inside the gate control box may require charging or replacement with new batteries. 5

TROUBLESHOOTING NOTE: Follow steps below if any of the components of the battery kit or the gate operator fail to operate properly. PROBLEM Battery charger LED (green) fails to light. Operator control board does not power up once power adapter is connected. Operator powers up but does not run properly. Operator works fine for several weeks or months but then batteries die. Red LED load disconnect on. SOLUTION 1. Solar panel(s) may not be mounted properly or the day may be too cloudy to provide enough sunlight. Check mounting, orientation, and possible shading of the solar panel(s) or wait for a brighter day to verify. Check the panel(s) for damage or pinched wires. 2. Wire polarity connections. Verify that the red and black wires go to the correct locations on the battery charger module (see wiring diagram). 1. This battery kit will only work with operators that have local batteries that are used to provide motor current. Make sure these batteries are good and properly connected to operator control board. NOTE: This battery kit does not replace the operator batteries nor will it prevent the replacement of those batteries during normal maintenance for the operator. 2. Blown fuse. It is possible that a fuse, either in the battery cable harness or on the operator control board, may have been blown during the installation. If a blown fuse is found, first check all wiring to make sure it is correct, and then replace the fuse with the same size and type. 3. Battery is not charged. It is possible that the 12V 75AH min. battery (not provided) was not fully charged when installed. Use a voltmeter to make sure this battery is good and has at least 12V across the open circuit terminals. 1. Debris or other obstructions are affecting gate travel. Make sure that the battery box, solar panel(s), and all connecting wires are clear of the gate. Clear the gate of all obstructions and verify all protection devices are operating properly. See gate operator owner s manual for additional troubleshooting. 1. Obstructed solar panel(s). Verify the correct installation and orientation of the solar panel(s). Make sure that the solar panel(s) is unobstructed from the sun throughout the entire day and the glass is clean. 2. Too many accessories will eventually drain the battery despite its larger size and capacity. Contact technical support at 1-800-528-2806 if accessories are required for the installation. Mag-locks must NOT be used with solar applications. 3. Inadequate solar panel(s). Many locations are not suitable for solar installations because of local geography or locations that simply do not receive enough sunlight. Contact technical support to determine if an additional solar panel(s) will help with your installation or if solar is entirely unsuitable. 4. Make sure SAVE switch is on after adjustments have been made for the LA400. At 11.5V, the light comes on. Refer to Troubleshooting Procedures. 6

TROUBLESHOOTING PROCEDURES Required test equipment: Digital multimeter, to measure current (5 amps max.) and DC voltage All solar measurements must be taken when the sun is out. If your operator is not working, due to a low battery condition, follow the following steps (gate will be open and red LED on the sunsaver will be on): 1. Measure the voltage on the primary batteries. The combined battery voltage must be above 25V, if not, recharge or replace the internal batteries. 2. Remove the external battery box cover and check for load disconnect LED (red). If load disconnect is on, remove battery and charge to 12.5Vdc. 3. Verify that the battery is a 75 amp Hour (min.) Sealed lead-acid battery (SLA). Other types of batteries will dramatically decrease the effectiveness of this kit (do not use a standard automotive battery). If using a flooded, marine-type battery, make sure that the jumper is removed (see page 3). 4. Check fuse and all other connections in battery box. 5. Remove the external battery from the battery box while wires are connected. 6. Open the main control box and disconnect the white wire, from the battery box to the power adapter. 7. Inside the battery box, remove red wire from the solar panel(s) to sunsaver and place a DC amp meter between the red wire from the solar panel(s) and terminal 4 on the sunsaver (Figure 1). The current should read 0.8 amps with the panel(s) pointed properly in direct sunlight unless the battery is fully charged. If less than 0.8 amps, clean and/or redirect the panel(s) due south. An additional panel(s) may be required. 8. Reconnect the red wire from the solar panel(s) to terminal 4. Disconnect the black lead of the battery and measure the current between the black wire and the negative battery terminal (Figure 2). Readings should be slightly less than the reading in step 7 (a current reading much less than step 7 indicates a problem with sunsaver or battery is fully charged). If battery checks OK, replace the sunsaver. 9. Reconnect the external battery and measure voltage across 5 & 6 on the sunsaver (black and white). Now measure the voltage across the black and white wires at the adapter located in the electrical box (Figure 3). Voltage should be the same. If not, check connection. Reconnect the white lead. 10. Measure the voltage coming out of the power adapter (black and yellow wires) (Figure 4). This should be greater than 30 volts. If not, replace the power adapter. 11. If there are still problems with the installation, please contact Technical Support at 1-800-528-2806. FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 7

WIRING DIAGRAM MorningStar SS-6-12V SOLAR PANEL BATTERY BOX OPERATOR RED 4 SOLAR 3 - BATTERY 2 1-6 LOAD 5 - SEALED OR FLOODED REMOVE METALLIC JUMPER FOR MARINE BATTERY WHITE YELLOW 24Vac Input CONTROL BOARD BLACK F1 RED POS (RED) SA ATC 12VDC SEALED LEAD ACID BATTERY MINIMUM 75 AH NEG () POWER ADAPTER NOTE: Automotive batteries are not acceptable. 2009, The Chamberlain Group, Inc. 01-34938 All Rights Reserved