Waste Incineration Plants



Similar documents
INCINERATION PLANTS. Hazardous waste incineration Wastewater incineration Sewage sludge incineration. A Bayer and LANXESS company

Waste to Energy in Düsseldorf. for a clean city.

Efficiency on a large scale CFB Steam Boilers

How To Run A Power Plant In Celje

Enhanced power and heat generation from biomass and municipal waste. Torsten Strand. Siemens Power Generation Industrial Applications

TBU Stubenvoll GmbH. Experience and Competence in Environmental Technologies. TBU Stubenvoll GmbH

of 11,000 households Steam temperature, boiler 400 C Steam pressure, boiler Incineration temperature 1,100 C

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal.

Iron and Steel Manufacturing

PHARMACEUTICAL AND CHEMICAL WASTE MANAGEMENT

TODAY S THERMAL OXIDIZER SOLUTIONS TO MEET TOMORROW S CHALLENGES

POLYCITY. Technical measures and experiences at a 6 MW cogeneration plant with wood chip furnace POLYCITY

Official Journal of the European Communities

Cooking at the Speed of light!

Ligentoplant - The biomass cogeneration. Ligento green power GmbH

Stora Enso Fors Ltd Sweden

Improving Energy Efficiency through Biomass Drying

Description of Thermal Oxidizers

1 DESCRIPTION OF THE APPLIANCE

Drying of Woody Biomass. Process Engineering / GEA Barr-Rosin

1.3 Properties of Coal

Routine and Emergency Boiler Operation

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

TABLE OF CONTENT

INTRODUCTION. Fact Sheet: Air Pollution Emission Control Devices for Stationary Sources

Module 5: Combustion Technology. Lecture 34: Calculation of calorific value of fuels

IT3 01 Conference, Philadelphia, PA, May 14-18, 2001

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

Online Infrared Flue Gas Analyzer Gasboard 3000

JASE-world Waste to Energy Sub WG Masanori Tsukahara Hitachi Zosen Corporation

SULFUR RECOVERY UNIT. Thermal Oxidizer

COMBUSTION. In order to operate a heat engine we need a hot source together with a cold sink

GUIDELINES FOR PROCESSING AND USING REFUSE DERIVED FUEL (RDF) IN CEMENT INDUSTRY

THE OPTIMISATION OF BIOMASS COMBUSTION IN SMALL BOILERS

The Fate of Ammonia and Mercury in the Carbon Burn-Out (CBO ) Process

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

Nitrogenous Fertilizer Plants

Chapter 2.2: Boilers

AN EFFECTIVE THERMAL TECHNOLOGY FOR THE DETOXIFICATION OF THE MSW FLY ASH

INCINERATION IN JAPAN

Waste to Energy. Anders Damgaard. Thanks to Jiri Hyks and Thomas H Christensen DTU for some slides

The soot and scale problems

PLANT LOCATION AND LAYOUT

rbital Fields of application Variants

A Review on Power Generation in Thermal Power Plant for Maximum Efficiency

COKE PRODUCTION FOR BLAST FURNACE IRONMAKING

HYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3

Optimization Design for Sulfur Dioxide Flow Monitoring Apparatus in Thermal Power Plants Hao-wei Hu 1, a, Xue Yang 1, b and Xiao-wei Song 1, c

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation

Overview of Waste Heat Recovery for Power and Heat

10 Nuclear Power Reactors Figure 10.1

BorsodChem MCHZ, Czech Republic. 6,000 Nm 3 /h HTCR Topsøe Hydrogen Plant A Case Story: 18 Months from Engineering to Operation

Biomass Boiler House Best Practices. Irene Coyle & Fernando Preto CanmetENERGY

5.2. Vaporizers - Types and Usage

WASTES INCINERATION PLANTS

Selective Catalytic Reduction (SCR) and Diesel Exhaust Fluid (DEF) Training Module

6 CONSIDERATION OF ALTERNATIVES

BOILER OPERATORS HANDBOOK

SO 3 -Monitoring in Flue Gas of a Power Plant Application & Results

Overview of Integrated Coal Gasification Combined-cycle Technology Using Low-rank Coal

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

Developments and trends shaping the future for Waste-to- Energy technology suppliers

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Dehumidifier D 850E. - Instruction manual version 02

Condensing Economizers Workshop Enbridge Gas, Toronto. MENEX Boiler Plant Heat Recovery Technologies. Prepared by: Jozo Martinovic, M A Sc, P Eng

TABLE OF CONTENT

TURKISH REGULATION ON LARGE COMBUSTION PLANTS

Thermal and Catalytic Oxidation Systems

Half the cost Half the carbon

Printing and Publishing Energy Savings Guide

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

NAWTEC COMPARISON OF ACID GAS CONTROL TECHNOLOGIES IN EFW FACILITIES

Pellet Process - Uses and Exposures

BIOPOWER 5 CEX. 1 Wärtsilä 10 January 2012 Presentation name / Author

Nu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition)

Boiler Preparation, Start-Up and Shutdown

2nd IEA Oxyfuel Combustion Conference

Stack Sampling Stack sampling or source sampling

Operating Performance and Latest Technology of DeNOx Plants for Coal-Fired Boilers

AMMONIA AND UREA PRODUCTION

Haldor Topsøe Catalysing Your Business

Energy Saving Fact Sheet Boilers

Module 5: Combustion Technology. Lecture 33: Combustion air calculation

CT556 Boiler Efficiency Modern Controls for Package Boiler Operations

Practical Examples of Heat Regenerative System at Steelmaking Works

COMMON LABORATORY APPARATUS

As of: September Waste Incineration A Potential Danger? Bidding Farewell to Dioxin Spouting

Marsa Thermal Treatment Facility Yearly Emissions Statement

MONITORING & MEASURING EQUIPMENT FOR EMISSIONS CONTROL, HAZARD DETECTION & ENERGY OPTIMIZATION

steam centre of excellence Steam Boiler System Optimization

Texas Commission on Environmental Quality Page 1 Chapter Control of Air Pollution from Nitrogen Compounds

It s time for H.E.R.O. Energy Saving Strategy for. Tunnel & Shuttle Kilns

Fact Sheet Technology. Bergius-Pier Process (1)

INTEC Engineering GmbH Heating Solutions for the Marine Industry

Finanzierung von Erneuerbaren Energie und Energieeffizienz Projekten in Asien. INTEC Engineering GmbH Berlin,

Transcription:

Waste Incineration Plants Modern Technology for a better Environmental Welcome at Hafner! We Manufacture Systems for Energy Recovery from Wastes and Biomass as well as for Treatment of Hazardous Wastes. www.hafner.it

Environmental technology by Hafner Firm Hafner builds facilities for: energy recovery and biomass/ organic substances treatment of hazardous wastes and medical wastes The design is in each case modified to the respective requirements, the facility is always laid out for the actual requirement, so as to save investment costs. An additional process line can be added and operated parallel if at a later point in time the incineration capacity needs to be increased. The system capacity with a standard facility can handle between 1000 t/y up to 25000 t/y. If required, this system can also provide for a greater throughput capacity per line. Characteristics of all Hafner Systems: Set up in individual modules: 8 modules like ship container modules, e.g. for a system with a throughput of 7000 t/y or 22 modules with an incineration facility with 25000 t/y. High Flexibility: This system can be operated with different incineration temperatures for the energy recovery from household waste and similar wastes, but also for the incineration of hazardous and medical wastes. Very economical/low investment and operating costs Utilization of established and approved technologies The System concept consists of the following three (3) essential main components: 1. Rotary kiln with subsequent afterburner chamber 2. Heat exchanger or steam boiler for energy utilization 3. Multi-layer flue gas purification, including catalyst All system are built in modular technology. The control and operation of the system/plant is done through a computer. The emission values are continuously monitored and recorded. Since the Hafner - concept is offered as a "building block/modular system", it is possible to assemble the thermal system in any desired size based on the respective requirement. Such system concepts, starting with an annual throughput of about 30000 tons, generally are multiple line and guarantee thus a high degree of disposal safety and flexibility. Should you for technical reasons wish to use a firing over a grid rack instead of the rotary kiln: this is also possible. Instead of the "module rotary kiln" the "module grid rack" can be built into the system. Systems with an incineration capacity of less than 7000 tons per year can also be manufactured as mobil facility, if required. These are than housed in container modules (ships containers) and can be set up in very short time at any location and put into operation. Below is the description of two variations. 2

Mobile System... for de-centralized thermal treatment Mobile facility for de-centralized energy recovery from hazardous wastes De-centralized systems for incineration of hazardous wastes and medical waste (mobil facility with an incinerating capacity of 5000 t/y) Example: Hazardous waste incineration plant Hafner in Bozen stringent national regulations, like the 17th Federal Emission Protection Regulation (BImSchV) of the Federal Republic of Germany. The following incineration temperture are achieved Maximum furnace temperature in rotary kiln: 1050 degrees C Maximum post-combustion temperature: 1300 degrees C The system designed as described above is installed in 8 ship containers: Technical description wastes. Rotary tubular kiln for hazardous und hospital The following tender specification describes a mobile waste incineration plant. Index: 1) Basic Information 2) Process description 3) Technical features 4) Flue gas purification 5) Control devices 1. Basic Information: The incineration facility is totally mobile and can be transported on a truck with a hydraulic gripping device. All components are completely installed in ship container modules. The technical concept complies with the regulations of the European Union and more 1 st container: furnace, with feeder and continuous ash discharge 2 st container: afterburner chamber with additional burner and emergency flue stack 3 st container: flue gas cooler with heat exchanger 4 st container: flue gas purification with fabric filter 5 st container: flue gas washing (dry adsorption process) 6 st container: catalytic NOX and Dioxin- and furan separation, ventilators, flue 7 st container: central controls 8 st container: service, emergency generator and compressor. In addition to these basic containers, other containers are provided to temporarily store hazardous wastes. These containers are set up next to the system feeder. 3

... Mobile System for de-centralized thermal treatment 2. Process description: 3. Technical features: The solid and paste-like hazardous wastes are pushed into the rotary tubular kiln by a spiral-like screw conveyor or a stopper. Liquid wastes are injected via an injection nozzle into the rotary tubular kiln and into the afterburner chamber. The rotary tubular kiln is the most universal method of incineration of hazardous wastes of different composition. Solid as well as pasty and liquid materials can be fed into the furnace for incineration at the same time. Through a high excess of air and through the constant addition of supplemental fuel, thorough incineration is guaranteed. The hazardous waste and the incineration air is introduced into the system from the front side of the rotary kiln. From the opposite end the slag and flue gas is being discharged. General data: Operating capacity - 600-700 kg/h Flue gas volume total - 5000 Nm3/h Number of containers - 8 Total weight of system - 100 Tonnen Dimensions of containers - 6050x2500x2560 mm Rotating furnace: Technical Data: Rotary kiln volume - 5000 ltr. Operating temperature - 900-1200 Grad Holding time of flue gas - 2 Sek. mindestens Holding time of waste - 1-2 Stunden Minimum Oxygen content - 6 % Average wall lining thickness - 250 mm Loading system - Helicoidal conveyors Burner - 300.000 kcal/h Rotary kiln weight - 18900 kg Primary air/fan volume - 1000 Nm3/h After-combustion chamber: Technical Data: Incineration temperature Holding time Volume of chamber Wall lining thickness Burner capacity - 1200-1300 degrees C - 2 Sec. minimum - 12000 ltr. - 250 mm - 1000000 Kcal/h 4

... Mobile System for de-centralized thermal treatment Firing in a rotary kiln Since a separation of dioxin and furan through furnace coke and a white reactant (soda) has already taken place before, the catalyst guarantees very good discharge results. After this complete purification, the flue gases are released through a chimney into the atmosphere with a temperature of 240 to 260 degrees C. 5. Control devices: ll engines, fans, valves, switches, control units... are designed and installed according to the state of the art and are controlled via a computer. This computer is capable to automatically triggering the necessary measures in case of a fault or failure in the system. steps: The operating personnel are notified in two As a first step a siren sounds, warning lights in a control panel identify the malfunction. If the malfunction or breakdown is not corrected within the stipulated time period, the second step is triggered. The feeder is shut off, the emergency chimney is opened and the vacuum fan is turned off. 4. Flue gas purification: A complete incineration of the organic components in the flue gases is assured in the afterburner chamber through the appropriate air intake, high temperature and a long holding time. The hot flue gases from the afterburner are being cooled off in a heat exchanger or boiler, prior to cleaning. In the process the flue gases are first passed through a Teflon coated fabric filter. At this point, the solid and dust-like particles are collected. Through injection of a mix of white reactant (soda), furnace coke and bicarbonate in an additional step, the contaminants (HCL, SO2, HF, volatile heavy metals, hydro-carbons, dioxin) are removed out of the flue gases. A catalyst is added in the next step of the process to further reduce nitric oxide, dioxin and furan in a catalyst. All metered values are collected in this central control, they are put into memory and in accordance with the local environmental conditions printed out via a printer. Heat Exchanger 5

Decentralized concept... for energy recovery Process Description Decentralized concept for energy recovery of household and industrial wastes In the past, many waste incineration plants were design with excessive capacity, as a consequence they are often today not fully utilized and are inefficient. The waste is picked up with a gripper and dropped into a funnel from there it is moved by a spiral-like screw conveyor or a hydraulic stopper, into the front side of the furnace The answer from Hafner to this : Through the construction of relatively small decentralized systems we can offer regional solutions. The size of the respective system is designed based on the waste economy concept of the region or the industrial enterprise. With larger quantities two or several lines can be operated parallel to each other. Through the combination of various sizes, offered as modules, one can, as in a building block system, compose systems to a desired size. This guarantees a high flexibility, a great assurance of disposal and efficient handling. Depending on the operation of the rotary kiln and the incineration temperature the incineration product can be either ash or sinter material or glazed slag. Incineration Unit for 25.000 tons annually Such a system consists of 3 essential elements, composed of several modules: Rotary kiln with afterburner chamber Heat exchanger and boiler Pasty and viscous liquid materials are pumped in, highly fluid material is injected into the burning chamber Ṫhe throughput capacity is 3.5 t/h. The operational temperature in the rotary kiln is 950-1000 degrees C. The rotating speed of the rotary tube and the feeding are controlled through a temperature- and oxygen tube. Through various nozzles the primary air is injected, creating a higher turbulence, it also assures a good oxidation. The burner at the end of the rotary kiln is only ignited at the start up of the system or with a poor calorific value of the waste. The slag created from the incineration falls into a water bath at the end of the furnace. With a higher calorific value material when higher incineration temperatures the rotary kiln is being operated with direct current. The hot flue gas flows from the rotary kiln into the afterburner chamber and is held there for at least 2 seconds at an incineration temperature of 1050 degrees C Multi-step flue gas purification Depending on the final standard, particularly as concerns the flue gas purification, 22 modules represent a complete system facility. 6

... Process description Heat exchanger and boiler The flue gas will be cooled down in a steam boiler to 260 degrees C. The energy created through this is utilized in the form of heat, steam or electrical energy. Cleaning of exhaust gases: Here two possibilities can be offered depending on the exhaust gas composition and required emission values: 1. The dry adsorption process or 2. A combination process, taking the flue gases in addition through washing towers ("wet wash"). After cooling down of the flue gases they are sent through a teflon-coated hose filter. Here the solid and dust-like particles are separated. Through injection of furnace coke and reactant (soda), dioxin furane, SO2, HCL and heavy metals are minimized. The dust collected will be removed together with the absorption agent through the spiral-like screw conveyor. The filter cleaning will be accomplished with air pressure jets. With this combined process the flue gases are then sent through a "wet wash". In a GFK wash tower through a countercurrent principle the acidic components are washed out with water and filling material. In a second wash tower a ph value of 7 is set by adding soda. The waste water of acidic and alkaline wet cleaning are neutralized and moved through a pump to the spray reactor. There they are injected through a nozzle into the flue gas for evaporation. Prior to allowing the flue gases to mix with the catalyst, they are heated up with the countercurrent principle in a heat exchanger to about 250 degrees C. Through the injection of reaction agents into the catalyst the dioxin and furan as well as NOX are separated. Dioxine und Furane, sowie NOX ausgeschieden. 7

Schematic for set-up of a system facility Decentralized facility for energy recovery from wastes with 25.000 t/y flue gas wash acidic heat exchanger -4 dust filter with absorber spray reactor heat exchanger 3 heat exchanger 1 afterburner chamber rotary kiln incinerator flue gas wash alkaline catalyst heat exchanger 2 chimney Info: GmbH Negrellistraße 5 I-39100 Bozen Info: Tel. 0039-0471-91 08 44 Fax 0039-0471-91 57 36 email: info@hafner.it