Inline Chlorinator Chlorine Chemical Feeder



Similar documents
Stenner Pump Chlorinator Installation & Start Up Guide

Iron Air Charge 2510-SXT Installation & Start-Up Guide

MODEL #320 - (* Using Bromine tablets with this device is not NSF certified)

Maintenance Guide For Above Ground Pools

Troubleshooting a Greensand Plus filter system

What To Do When Your Well is Flooded. Common Sense Steps To Take If Your Well Is Covered by Flood Water

Water Treatment & Purification Chemicals

Owner s Manual / 5600 Econominder

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide

Pro-OX 7800 Iron Filter Installation & Start-Up Guide

Understanding basic pool chemistry is one of the most important factors in pool maintenance. Properly balanced water creates an environment that

Adjusting Chemical Levels in a Swimming Pool

Fiberstars Lighted Laminar Flow Fountain Installation Manual

POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS

NITROUS TRANSFER PUMP INSTRUCTIONS

MAINTAINING YOUR SPA WATER

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

WATER CHEMISTRY AND POOL WATER BALANCE

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

b. Alkalinity make your life easier and get the alkalinity between 80 and 120 PPM. c. ph from 7.2 and 7.8 so that the other chemicals work properly

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

WARNING WARNING TABLE 1.

Disinfecting Your Private Well

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

Support Cleaning Apparatus. Operation, Cleaning, & Safety Manual

Fuel. What you will learn. Things you need before you start. Materials. Tools. When you have finished this module, you should be able to:

Scaletec Plus. Descaling Overview, Guidelines, Cleanup Tips, And Question & Answers

Easy as instructions on how to install or replace the Cleanviro waterless urinal tablet

Simply complete the enclosed Warranty Form with contact details, or us with your details and date of purchase.

Cal Water 1961 Petra Lane, Placentia, CA (800) CAL-WATER (800) FAX: (714)


Well and Water System Disinfection For Private Wells

FERTIGATION. Lawrence J. Schwankl

Fleck 7000 Softener Installation & Start-Up Guide

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

CLEAN AND CLEAR PLUS CARTRIDGE FILTER

Injection Systems INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL SYSTEMS

Metermatic SE Automatic Water Softener. Operation Manual

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

Common Causes of High Water Bills

FLUSHMATE FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual 503 and 504 Series

Parker Hannifin Corporation Process Advanced Filtration Division 2340 Eastman Avenue Oxnard, California USA

SunMaxx Solar Filling Station Operating Instructions

BF Series Sa S n u d p Fe i r l C t l e e r a n Installation Manual -1-

Aqua Rite & Aqua Rite XL Diagnostics Manual

Hot Tub Start-up Guide

Model MS-41BP 4G/ 15L. WARNING Carefully Read These Instructions Before Use R0514

Water System Disinfection

ACID START-UP FOR POOL BUILDERS & SERVICE PROFESSIONALS

Agricultural and Veterinary Chemicals Code (Listed Chemical Product Home Swimming Pool and Spa Products) Standard 2014

Voltmaster Trash Pumps Model TSP2, TSP3 and TSP4

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

Pro Logic Version Diagnostics Manual

B150 Series Commercial Brewer. Direct Plumb Kit

GENERAL CARE PLUMBING & VALVE INFORMATION TUB & SHOWER DOOR INFORMATION FOR QUESTIONS CALL OUR SERVICE DEPARTMENT

After the reactor has been running and the air in the chamber has been purged the co2 can be introduced and the dial in process can begin.

San josé OWNER S MANUAL

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

Basic Chemistry of Chlorination

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

PRIVATE WATER SUPPLY - WATER SAFETY MAINTENANCE PLAN

123 Industrial Loop Road Paynesville, MN Phone:

Installation Manual DIAPHRAGM WELL TANK

Physical and Chemical Changes

Rexroth Hydraulic Pump A10VO Series User Manual

Line to Refrigerator Ice/Water Dispenser

MC4-50 Feeding System

Indiana Department of Environmental Management. Well Disinfection

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Most agencies think about cleaning because of debris in the line.

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

PLUMBING CARE AND REPAIR

Operator s Manual. PUMP Model: PAC25 SAVE THIS MANUAL FOR FUTURE REFERENCE. Distributed by: Pacer Pumps

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Home Drinking Water Treatment Systems

Watts Pure Water Systems

Tankless Water Heater

Repair and Disinfection of Water Mains Water Protection Program fact sheet

Copper Meter Resetters

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.

DO-IT-YOURSELF SEPTIC SYSTEM INSPECTION FIELD GUIDE (Mound System)

Guide to Common Water Quality Concerns

Water Treatment Solutions for Residential & Light Commercial Applications

A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS

Never use a spa or hot tub alone. Do not allow children to use a spa without supervision.

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Calcite PH Nutralizer System

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

01 - Plastic Pipe Cements and Primers

Operator Quick Guide EC SENSOR

Overheating limit control

detection kit the water leak water leaks: What you should know A helpful guide for locating indoor and outdoor water leaks Getting Ready

Bio-Clean. for Septic Systems. Tips for Using Bio-Clean. Page Index METRIC CONVERSIONS

Septic Tank to Cistern Conversions. Saving Water & Saving Money

FILLING AND PURGING THE SYSTEM

Transcription:

Inline Chlorinator Chlorine Chemical Feeder Instructions Page 1 Chlorine setting in P.P.M. for center tube and cap Hole #1 = 2 P.P.M. Hole #2 = 8 P.P.M. Hole #3 = 30 P.P.M. Hole #A = 3.5 P.P.M. Hole #B = 13 P.P.M. Hole #C = 40 P.P.M. All holes closed will deliver 60 P.P.M per pump cycle. This chart is for a 42 gallon or equivalent pressure tank. When using an 80 gallon pressure tank, the P.P.M. amount will be 50% less per pump cycle. A 20 gallon pressure tank will yield 2 times the amount. Each number or letter will show a different hole in the cap. Line up the 3 holes in the cap with the proper number or letter directly under it (as per figure 1). The hole in the tube should show in the center of the hole in the cap. UNITS MUST BE INSTALLED AFTER PRESSURE TANK Install P.V.C. check valve BEFORE the feeder if water is used after pressure tank and before feeder inlet. USE CAUTION WHEN DRAINING CHLORINE: Chlorine can bleach clothes and may burn eyes and skin. See manufacturer details for proper handling. When removing center tube for cleaning, check hole setting in cap. After cleaning, be sure the setting is the same before replacing the cap. Center tube MUST BE REMOVED AND CLEANED or replaced with the extra center tube and cap each time before refilling. REMOVE CHEMICAL FROM "FEEDER" WHEN NOT BEING USED!

Refilling Information for Model 400 Inline Chlorinator Chlorine Chemical Feeder Instructions Page 2 1. Shut off water ahead of feeder. 2. Open drain valve after feeder and relieve line pressure. 3. Unscrew top (No. 4) and remove adjustment tube (No. 8) to drain unit and replace with a clean tube and cap (No. 7). To clean the removed tube and cap, soak in a mixture of Muriatic Acid. One part Muriatic Acid to 5 parts water. Always pour the acid into the water. ADHERE TO THE WARNINGS FOR HANDLING AND USE OF MURIATIC ACID. Tube and Cap can also be cleaned by soaking in white vinegar over night or longer. 4. Unit Housing needs cleaning when center hole has builtup (under tube No. 8). Unscrew unions (No. 14), remove housing and soak in same mixture of Muriatic Acid as tube No. 8 until clean. Be sure flow arrow is in the same direction when reinstalling housing. 5. Fill with chlorine tablets to the bottom of cap (No. 7) and do not add water to the unit or operation will be inhibited. It may take a few pump cycles before chlorine is despensed. 6. Replace top (No. 4) and close drain valve. 7. Turn on water. If unit is used for odor removal, do not refill until odor returns to minimize chemical use. DANGER: DO NOT MIX DIFFERENT TYPES OR BRANDS OF CHLORINE AN EXPLOSION CAN OCCUR!

Inline Chlorinator Chlorine Chemical Feeder Instructions Page 3 INSTALLATION AND OPERATION INFORMATION The UNIVERSAL CHEMICAL FEEDER will operate on a varying pressure such as a home well system or on a constant pressure such as a sprinkler or pool system. When used as a constant pressure system, the optional rate of feed valve (No. 20) must replace N0. 11 valve as received. A charcoal filter must follow the CHEMICAL FEEDER on a varying pressure system for proper operation. Tests have shown that one cube of coconut shell based activated carbon is the best carbon to use (grade 9/50, mesh 8/30). We recommend installing the CHEMICAL FEEDER and filter tank before or after the softener. If installed before the softener, the filter will need periodic back washing. There are seven positions for varying the amount of chemical feed. Rotate the top cap (No. 7) so there is a hole showing through the level desired. There are two hole selections for each hole in the cap (No. 7). The smaller hole will dispense the greatest amount and selecting a lower hole on the cap will increase the output. Approximate chlorine readings using a 42 gallon pressure tank out of the CHEMICAL FEEDER per pump cycle in PPM, for each hole are: 1=2, A=3.5, 2=8, B=13, 3=30, C=40 and with no holes showing, the off position is 60 plus. These readings are obtained with no iron or hydrogen sulfide using the chlorine. Variables that will change the dilution are: pressure tank size, large volumes of water flow while pump is building pressure to shut off, horse power of the pump, and a water logged pressure tank or air pressure is low or high in the air bag. The CHEMICAL FEEDER will dispense the same amount of chemical for each cycle of the pump from maximum to minimum pressure. When used on a constant pressure and flow it is necessary to replace the valve (No. 11). Replace it with the optional adjustable valve (No. 20). It may be necessary to install the optional screen filters (No. 19) in the top inside hole of (No. 8) and screen (No. 18) in the adjustable inlet hole when using chemicals other than chlorine. When using the unit for constant pressure and flow such as a sprinkler system or pool; install the unit on the output to the sprinkler heads or on the return line to the pool. The adjustments for the varying pressure system should have no holes shown through in the off position. The amount of chemical dispensed is controlled with the adjustable valve on the outside of the unit. It may be necessary to adjust the unit if flow is increased or decreased.

Inline Chlorinator Chlorine Chemical Feeder Instructions Page 4 (Actual size of the CHEMICAL FEEDER - 10.5" high X 11.5" long Empty weight - 6.5 lbs.) Maximum tested pressure is 80 lbs. CAUTION: USE ONLY CALCIUM HYPOCHLORITE CHLORINE TABLETS FOR POTABLE WATER. THEORY OF OPERATION After filling the unit with chemical to no higher than the bottom of the adjustable cap or less and returning water flow, fluid will flow into the chemical container mixing with the chemical until the air trapped in the top of the unit is compressed to the same pressure as the line pressure. When the line pressure is reduced, compressed air in the air chamber will force fluid from the container down and up through the outside center tube and down the inside tube to the water line until pressure is equal or until the fluid level reaches the hole that is open in the outside tube. At that time, the compressed air will flow through the hole into the outside tube, down the inside tube and no more fluid will flow. This procedure will occur on each pump cycle. The outside tube has six (6) holes with three of them smaller. The cap can be rotated to select either a large hole or a small hole in six different locations. During fluid flow, a small amount of fluid will flow through the hole selected thereby diluting the fluid flowing up through the outside tube. Most chemical solutions are heavier than water and the top of the fluid is not as heavily saturated as the bottom of the container. Selecting a small hole will increase the chemical concentration and selecting a lower hole increases the solution output. The unit can be used as a venturi operation for operations other than varying pressure. In this mode, the cap may be rotated so there is no hole through the outside tube or left with the hole through the outside tube to help dilute the fluid if needed. The chemical solution put out is controlled with the optional rate of feed valve on the outside of the unit. WARNING: DO NOT MIX DIFFERENT TYPES OR BRANDS OF CHLORINE AN EXPLOSION CAN OCCUR.

Inline Chlorinator Chlorine Chemical Feeder Instructions Page 5 To oxidize 1 PPM of Hydrogen Sulfide (H2S), it takes 2.2 PPM of Chlorine (Cl2). To oxidize 1 PPM of Iron (Fe) it takes.64 PPM of (Cl2). Example: If you have a 4 PPM of Fe and 1 PPM of H2S, look on the vertical portion of the graph labeled PPM and start at 4 and move horizontal to the line marked Iron - Fe x.64 Cl2 and then down to the bottom of the graph marked Chlorine - Cl2 PPM. It should intercept the bottom at about 2.6. This is the amount of Cl2 needed to oxidize 4 PPM of Fe. Now look on the vertical portion of the graph labeled PPM and start at 1 and move horizontal to the line marked Hydrogen Sulfide - H2S x 2.2 Cl2 and then down to the bottom of the graph. It should intercept the bottom at about 2.2. This is the amount of Cl2 needed to oxidize 1 PPM of H2S. Example in dotted lines: 4 PPM Fe requires 2.6 PPM of Cl2. 1 PPM H2S requires 2.2 PPM of Cl2 Total Cl2 required is 2.6 + 2.2 = 4.8 PPM Cl2 Higher PPM than the graph can be calculated. Example: 20 PPM H2S x 2.2 Cl2 = 44 PPM of Cl2 20 PPM Fe x.64 Cl2 = 12.8 PPM of Cl2 If using a 42 gallon pressure tank, the No. 2 hole on the chemical feeder should be used. This will dispense about 8PPM of Cl2, and a filter with 1 cube of activated carbon after the unit will eliminate the excess Cl2. If using the chemical feeder for iron removal or extremely high H2S, it is necessary to use a retention tank and a back washing valve on the carbon filter. The Chemical Feeder will hold about 4 lbs. of Cl2 (1 gram tablets). If it is adjusted to the No. 1 hole, and using a 42 gallon pressure tank with 1 cube of activated carbon, the system should process approximately 20,000 gallons of water before the unit would need refilling.

Inline Chlorinator Features 5 4 1 2 3 1) Flow rate control 2) Large 1 1/2 in and out flow 3) Drain to release pressure or clean unit 4) Clearly labeled flow direction 5) Easy replacement of o-ring on lid Figure A

Tools and Materials needed 1) Pipe Cutters 2) PVC Glue 3) Two 1 ½ x 1 or 1 ½ x ¾ bushings - whichever your plumbing requires. 4) Two Ball Valves to cut off water supply. 5) One spigot to release pressure from system. (see Figure B) 6) One jug of chlorine pellets (available through Vitasalus/Equinox Products)

System Layout Well Pump Pressure Tank 1st Ball Valve Spigot 2nd Ball Valve Inline Chlorinator Figure B

Installing Chlorine Pellets 1. After checking that you have no leaks, you are now ready to add chlorine. 2. Turn the first and second ball valves to the off position. 3. Open spigot to relieve pressure from Inline Chlorinator Chlorine Pot Feeder. 4. Open Pot Feeder and close spigot. 5. Add Chlorine Pellets to Pot Feeder. 1. Close Pot Feeder turn ball valve back to the open position. Chlorine Dial Settings Problem Setting 1 ppm sulfur 1st notch 2-3 ppm sulfur 2nd notch 4-6 ppm sulfur 3rd notch.5-1 ppm iron 1st notch 1.5-2 ppm iron 2nd notch 2.5-3 ppm iron 3rd notch 3.5-up ppm iron 4th notch

Inline Chlorinator Maintenance 1. Turn the first and second ball valves to the off position. 2. Open spigot to relieve pressure from Inline Chlorinator Chlorine Pot Feeder. 3. Open Pot Feeder and close spigot. 4. Carefully clean the feeder tube with a pipe cleaner. 5. Add Chlorine Pellets to Pot Feeder. WARNING!! Do not mix brands of chlorine. Mixing brands may cause an explosion. 6. Close Pot Feeder turn ball valve back to the open position. 7. You will need to add chlorine to the system once every 2 to 3 months. 8. If the Inline Chlorinator clogs, you may need to clean it. To do so, Use a 5 gallon bucket and mix 3 parts water with 1 part Muriatic acid. 9. Soak JUST the Inline Chlorinator for 15 minutes. DO NOT put lid or o-rings in the solution. 10. Thoroughly rinse Inline Chlorinator in clean water. 11. Install the Inline Chlorinator back in line and let run for 20 minutes before adding chlorine.