AMBERLITE IRP64 Pharmaceutical Grade Cation Exchange Resin (Polacrilex Resin)



Similar documents
AMBERLITE IRP69 Pharmaceutical Grade Cation Exchange Resin (Sodium Polystyrene Sulfonate USP)

AMBERLITE IRP88 Pharmaceutical Grade Cation Exchange Resin (Polacrilin Potassium NF)

ACUSOL 830 Rheology Modifier and Stabilizer

ROVACE HP-2931 High Performance Vinyl Acetate/Acrylic Copolymer Emulsion

ACUSOL 810A Detergent Grade Rheology Modifier and Stabilizer

WATER TREATMENT GLOBAL PRODUCT SELECTION GUIDE

Material Safety Data Sheet

RHOPLEX SG-10M 100% Acrylic Emulsion For Interior/Exterior Semigloss Latex Paints

EUDRAGIT E 100, EUDRAGIT E PO and

DOWEX Resins as Organic Solvent Desiccants

Alharith Hassan. Q 10 Method of Shelf-life estimation. Methods of Chemical stabilisation 11/20/2015

Quality. Now Certified to ISO 9001:2008

ION EXCHANGE FOR DUMMIES. An introduction

ACUSOL 820 Rheology Modifier and Stabilizer

22 APR 2010 <MSDS_ID>300088</MSDS_ID> MATERIAL SAFETY DATA SHEET. <Product> PHENOLPHTHALEIN INDICATOR SOLUTION # HR </Product> Part#: N/A

HiPer Ion Exchange Chromatography Teaching Kit

SAFETY DATA SHEET Glen-Pak TM DNA purification cartridge (for use with disposable syringes) xx

Polymers for Better Living. BIO World Congress on Industrial Biotechnology June 17, 2013

ACUSOL 805S HASE Rheology Modifier and Stabilizer for High Surfactant Containing Detergent or Cleaner Formulations

EMERGENCY PHONE: or (651) (24 hours)

TECHNICAL BULLETIN. HIS-Select Nickel Affinity Gel. Catalog Number P6611 Storage Temperature 2 8 C

DEIONIZATION IN A "NUT SHELL"

About us. SNF has 40% market share, 1 B sales and manufactures tons of polymers on a world wide base.

3M MATERIAL SAFETY DATA SHEET NO. 4004, 4008, 4026 AND 4032 DOUBLE COATED URETHANE FOAM TAPE 07/29/2002

Corrosion Inhibitors in Antifreeze Coolants

Lewatit MP 62 is especially suitable for:

Material Safety Data Sheet

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE

INDUSTRIAL CHEMICALS

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Pipette Tips PACKARD BIOSCIENCE MultiPROBE II COMPATIBLE

APPLIED PETROCHEMICAL RESEARCH

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012

Material Safety Data Sheet SECTION 1: PRODUCT AND COMPANY IDENTIFICATION

oft Oftillovt Material Safety Data Sheet 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING 2. HAZARDS IDENTIFICATION

Material Safety Data Sheet

Sources of TOC in Deionized Water

EMERGENCY PHONE: or (651) (24 hours)

It's in the details. JOST MINERAL GUIDE

Acids, Bases, and ph

MATERIAL SAFETY DATA SHEET Consumer Product

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

Safety Data Sheet. SECTION 1: Identification. SECTION 2: Hazard identification

C-100E Strong Acid Cation Exchange Resin (For use in water softening applications)

- electrolytes: substances that dissolve in water to form charge-carrying solutions

GPS Safety Summary. Hydrogen Chloride/Hydrochloric Acid. HCl

Material Safety Data Sheet

Product Safety Summary Sheet

Molecular Sieve Adsorbents

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET

Dissolved Mineral Radioactivity in Drinking Water

Product Bulletin INTEROX HYDROGEN PEROXIDE

MATERIAL SAFETY DATA SHEET. CAPTURE Carpet Dry Cleaner - Advanced Formula

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

Material Safety Data Sheet

Material Safety Data Sheet

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012

Safety Data Sheet. Document Group: Version Number: Issue Date: 05/26/15 Supercedes Date: 10/09/14

AG 501-X8 and Bio-Rex MSZ 501(D) Mixed Bed Resin Instruction Manual. Bio-Rad Laboratories, 2000 Alfred Nobel Dr., Hercules CA LIT205 Rev B

Safety Data Sheet Deodorant Roll-On Aluminium Free. 1. Identification

DuPont Packaging & Industrial Polymers

MATERIAL SAFETY DATA SHEET

The Relationship between ph and Deionized Water

MATERIAL SAFETY DATA SHEET Complies with ANSI Z400.1 Format SECTION 1: PRODUCT IDENTIFICATION

C 5. chemical development contract research custom synthesis cgmp API manufacturing commercial production. Welcome to

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 13 / 7 / 2012

Separation by Solvent Extraction

Chem101: General Chemistry Lecture 9 Acids and Bases

An acid is a substance that produces H + (H 3 O + ) Ions in aqueous solution. A base is a substance that produces OH - ions in aqueous solution.

1. Chemical Product and Company Identification. 2. Hazardous Ingredients

Certificate of Compliance Section 1 - PRODUCT AND COMPANY IDENTIFICATION

MATERIAL SAFETY DATA SHEET TOILET BOWL SANITIZER

SAFETY DATA SHEET 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND COMPANY/UNDERTAKING PERSPEX CAST ACRYLIC SHEET: CLEARS AND TRANSPARENTS

A meaningful, cost-effective solution for polishing reverse osmosis permeate

Safety Data Sheet Aluminium profiles Apply for alloys Sapa EN AW 6060, 6063, 6005, 6005A, 6082, yellow chromated, with or without powder coating.

Independent Forensics of Illinois

PrepTip. Reverse Phase PrepTip User Guide

PRODUCT SAFETY DATA SHEET According to 91/155 EC 1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY / UNDERTAKING

Material Safety Data Sheet

SAFETY DATA SHEET FILE NO.: , DRY CIDER VINEGAR SDS DATE: 05/05/15

Melting Range 1 Experiment 2

Material Safety Data Sheet

: Fairy Professional Original Washing Up Liquid 5L

Silica Over-Saturation, Precipitation, Prevention and Remediation In Hot Water Systems Edited By Dave Peairs, Cal Water, Technical Director

Use of Noverite Polyacrylates In Soap, Detergent and Cleaning Products

Material Safety Data Sheet Ampicillin, sodium salt MSDS

Dispersing Powders in Liquid

Material Safety Data Sheet

2Technical Support 3Formulation Development 4Proof of Concept 5 GMP Services 6Advanced Drug Delivery 1EUDRAGIT Products Evonik. Power to create.

ACULYN 46 Rheology Modifier/Stabilizer An Efficient Shear Thinning Thickener Compatible with Cationics

CAS NO. A >94.19 % WT >94.19 % VOL SARA 313 NO

SAFETY DATA SHEET Revised edition no : 1 SDS/MSDS Date : 26 / 11 / 2012

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

Ion Exchange Resins for Metal Plating and Surface Finishing

1.1. Product identifier Scotch Super 33+ Vinyl Electrical Tape and Scotch Premium Vinyl Electrical Tape Super 88

SAFETY DATA SHEET West Skyhawk Drive West Jordan, UT U.S.A. Phone

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide

Colorants for Plastics are our Playground PRODUCT STEWARDSHIP: ONE STEP AHEAD WITH CLARIANT

Transcription:

AMBERLITE IRP64 Pharmaceutical Grade Cation Exchange Resin (Polacrilex Resin) Description AMBERLITE IRP64 [1] resin is an insoluble, weakly acidic, hydrogen form, cation exchange resin supplied as a dry, fine powder. AMBERLITE IRP64 resin is suitable for use in pharmaceutical applications, primarily as a carrier for certain basic (cationic) drugs and related substances. It is also used to mask objectionable tastes associated with certain basic drugs. Commercial examples of its use include: Stabilization of Vitamin B12 Sustained Release of Nicotine A Drug Master File for this product is maintained with the United States Food and Drug Administration. Letters of authorization granting access to the file by FDA in support of NDA and ANDA submittals will be provided upon request. Similar assistance can also be offered in support of the registration of formulations containing AMBERLITE IRP64 in many other countries. AMBERLITE IRP64 resin is manufactured in accordance with Good Manufacturing Practices (cgmp) for bulk pharmaceutical chemicals. Identification AMBERLITE IRP64 resin can be identified by infrared spectroscopy, as shown in the sample spectrum in Fig. 1. Table 1: Typical Properties These properties are typical but do not constitute specifications. Ionic form Hydrogen Appearance White to off white fine powder free of foreign matter and any agglomeration IR Identification Conforms to reference spectrum assay Exchange capacity «as is Not less than 10.0 meq/g, on dried basis

Purify testing Sodium Not more than 0.20 % Heavy metals Not more than 0.001 % Iron Not more than 0.01 % Methacrylic acid Not more than 300 ppm Water extractable impurities Not more than 2.0 % Physico-chemical testing Loss on drying Not more than 5.0 % Particle size > 0.150 mm Not more than 1.0 % > 0.075 mm 15. 0 to 30.0 % > 0.050 mm Not more than 70.0 % Microbial purity Total bacterial count Not more than 100 cfu/g Total mold count Not more than 100 cfu/g [1] The use of AMBERLITE pharmaceutical grade ion exchange resins as components of drug formulations is subject to the Food, Drug, and Cosmetic Act as amended. Chemical Structure AMBERLITE IRP64 resin is derived from a porous copolymer of methacrylic acid and divinylbenzene. The chemical structure of AMBERLITE IRP64 is shown in Figure 2. Applications Applications for AMBERLITE IRP64 resin include: Taste Masking Drug Stabilization Carrier for Cationic Drugs Controlled Release Formulations

AMBERLITE IRP64 resin provides a means for binding medicinal agents onto an insoluble polymeric matrix. This affords an effective technique for overcoming problems of taste and odor in oral dosage formulations as well as providing a matrix upon which a sustained or controlled release formulation can be developed. The high affinity of AMBERLITE IRP64 resin for the hydrogen ion results in ready desorption of adsorbed species by exposure to an acidic environment, such as that exhibited in the stomach. This accounts for the higher desorption efficiencies versus a strong acid cation resin like AMBERLITE IRP69. Chemical instability problems can sometimes be resolved by adsorption on to AMBERLITE IRP64 resin. For example, complexes of AMBERLITE IRP64 resin with cyanocobalamin (Vitamin B12), a nonionic material, have been used for many years as a means of providing a stable oral dosage form of this vitamin. Drug Loading Batch equilibration is the preferred practice when loading a drug or other sorbate into finely divided ion exchange operations normally used with ion exchange resins, resin powders. Due to its fine particle size, AMBERLITE IRP64 resin does not lend itself to conventional columnar operations normally used with ion exchange resins. The mobile, or exchangeable, cation in IRP64 resin is the hydrogen ion. In acidic environments (generally below ph 4) AMBERLITE IRP64 resin exists as the free acid in an essentially nonionic state. Adsorption (loading) onto this cation exchange resin is usually carried out at ph 6 or higher. The amount of drug loaded onto AMBERLITE IRP64 resin will be influenced by such factors as: The inherent affinity or selectivity between the ion exchange resin and the drug. The concentration of the drug in the loading solution. The concentration and selectivity of competing cations. The ph of the loading solution. The rate of loading will be affected by the activity of the drug and its molecular dimensions as well as the extent to which the polymer phase is swollen during loading. When utilizing a batch or equilibrium contact to load a drug or other anionic sorbate onto AMBERLITE IRP64 resin, it may be desirable to load as much as possible of the substance of value onto the resin. Complete transfer of the drug from the loading solution is not likely in a single equilibrium stage. Accordingly, more than one equilibration may be required in order to achieve the desired loading onto the resin. The use of two or more loading stages, separating the resin from the liquid phase between stages, is an effective means of achieving maximum loading of the drug onto the resin while maintaining minimum loss of drug from the liquid phase of the final stage. Carefully controlled laboratory experiments are required to establish precise loading and elution conditions. Drug Release The rate and completeness of drug desorption in vivo will be controlled by the diffusion rate of the drug through the polymer phase of the resin, (usually a function of molecular weight), the selectivity of the drug for the resin, and the concentration of electrolytes particularly in the hydrogen ion, in the desorption environment. More hydrophobic drugs will usually elute from the resin at a lower rate, as will drugs with a relatively high selectivity for the carboxylic acid functional structure in the resin. Other resin-sorbate interactions are possible, and these can have a pronounced effect upon loading capacities and rates. An example of this might be the presence of a transition metal in the structure of the sorbate molecule which can result in considerable selectivity through the formation of a coordination compound with the resin.

Safe Handling Information Material Safety Data Sheets (MSDS) are available for all Rohm and Haas products. These sheets contain pertinent information that you may need to protect your employees and customers against any known health or safety hazards associated with our products. We recommend that you obtain copies of our MSDS by calling 1-800-RH- AMBER before using our products in your facilities. We also suggest that you contact your suppliers of other materials recommended for use with our products for appropriate health and safety precautions before using them. Caution: Acidic and basic regenerant solutions are corrosive and should be handled in a manner that will prevent eye and skin contact. In addition, the hazards of other organic solvents should be recognized and steps taken to control exposure. Nitric acid and other strong oxidizing agents can cause explosive reactions when mixed with ion exchange resins. Proper design of process equipment to prevent rapid buildup of pressure is necessary if use of an oxidizing agent such as nitric acid is contemplated. Before using strong oxidizing agents in contact with ion exchange resins, consult sources knowledgeable in the handling of these materials. Note: Ion exchange resins and polymeric adsorbents, as produced, contain by-products resulting from the manufacturing process. The user must determine the extent to which organic by-products must be removed for any particular use and establish techniques to assure that the appropriate level of purity is achieved for that use. The user must ensure compliance with all prudent safety standards and regulatory requirements governing the application. Except where specifically otherwise stated, Rohm and Haas Company does not recommend its ion exchange resins or polymeric adsorbents as supplied as being suitable or appropriately pure for any particular use. Consult your Rohm and Haas technical representative for further information. Amberlite IRP64 Applications Reference List Controlled/Sustained Release Leo Corporation, 1973. Smoking substitutes and method of production. Patent GB 1,325,011. Taste-Masking Douglas, S.J. Glaxo Group Research Ltd, 1990. Process for the preparation of a ranitidine resin absorbate. US 5219 563. Astruc, J., and A. Sambot, 1970. Ion-exchange resin: spiramycin compositions. Patent GB 1,180,233. Borodkin, S., and D.P. Sundberg, 1971. Chewable tablets including coated particles of psuedoephedine- weak cation exchange resin. Patent US 3,594,470. Other Fretland, D.J., 1974. Use of ion-exchange resins for removing prostaglandins from human urine prior to radioimunoassay. Prostaglandins 6 (5): 421-425. Miles Laboratories, Inc., 1970 Detection device for enzymes and other factors in body fluids. Patent US 3,616,251. All our products are produced in ISO 9001 certified manufacturing facilities.

AMBERLITE is a trademark of Rohm and Haas Company, Philadelphia, U.S.A. Ion exchange resins and polymeric adsorbents, as produced, contain by-products resulting from the manufacturing process. The user must determine the extent to which organic by-products must be removed for any particular use and establish techniques to assure that the appropriate level of purity is achieved for that use. The user must ensure compliance with all prudent safety standards and regulatory requirements governing the application. Except where specifically otherwise stated, Rohm and Haas Company does not recommend its ion exchange resins or polymeric adsorbents, as supplied, as being suitable or appropriately pure for any particular use. Consult your Rohm and Haas technical representative for further information. Acidic and basic regenerant solutions are corrosive and should be handled in a manner that will prevent eye and skin contact. Nitric acid and other strong oxidising agents can cause explosive type reactions when mixed with ion exchange resins. Proper design of process equipment to prevent rapid buildup of pressure is necessary if use of an oxidising agent such as nitric acid is contemplated. Before using strong oxidising agents in contact with ion exchange resins, consult sources knowledgeable in the handling of these materials. Rohm and Haas Company makes no warranties either expressed or implied as to the accuracy of appropriateness of this data and expressly excludes any liability upon Rohm and Haas arising out of its use. We recommend that the prospective users determine for themselves the suitability of Rohm and Haas materials and suggestions for any use prior to their adoption. Suggestions for uses of our products of the inclusion of descriptive material from patents and the citation of specific patents in this publication should not be understood as recommending the use of our products in violation of any patent or as permission or license to use any patents of the Rohm and Haas Company. Material Safety Data Sheets outlining the hazards and handling methods for our products are available on request. Rohm and Haas, 2006 All rights reserved. February 2006