S-series DC to DC Power Supply



Similar documents
S-series DeviceNet Interface Card

S-series SQ Controller

M-series MD Plus Controller

M-series FOUNDATION Fieldbus I/O

S-series Mass Connection Solutions

DeltaV SISnet Repeater

Wireless I/O Card. Wireless I/O Card. Introduction. DeltaV Product Data Sheet

M-series Virtual I/O Module 2

DeltaV S-series Traditional I/O

S-series Electronic Marshalling

Power Supplies 3. SDN-P DIN Rail Series

DeltaV SIS for Burner Management Systems

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Plant Messenger Alert Reporting Service

How To Protect Your Deltav Controllers From Cyber Attacks

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

DeltaV Event Chronicle

DeltaV Workstation Operating System Licensing Implications with Backup and Recovery

OPC Data Access Server Redundancy

Emerson Smart Firewall

CompactLogix Power Supplies Specifications

The Personal Computer for DeltaV Wokstations

DeltaV Web Server. DeltaV Web Server. Introduction. DeltaV Product Data Sheet. Gives you a secure view of your process from your desktop PC

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Wireless Field Data Backhaul

Plantwide Event Historian

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

SYSTEM DESCRIPTION Termination Boards

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Rosemount 333 HART Tri-Loop

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

Base Station. Base Station. Introduction. DeltaV Product Data Sheet. Adaptable work environment. Scalable to suit your needs. Dedicated functional use

Rosemount 333 HART Tri-Loop

IMR 6000/10../20../30

3500/62 Process Variable Monitor

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Professional Station Software Suite

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

Maintenance Station Software Suite

Cisco Unified IP Phone Power Injector

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

DeltaV Virtual Studio

How To Use The Deltav System With A Large Data File System

DeltaV Control Network Hardware

UMEC International Corporation

Backup and Recovery. Backup and Recovery. Introduction. DeltaV Product Data Sheet. Best-in-class offering. Easy-to-use Backup and Recovery solution

ST Series POWER SUPPLIES USER INSTRUCTIONS

Wireless Remote Video Monitoring

1756 ControlLogix Chassis Specifications

Actuator-Sensor-Interface

OPC Mirror. OPC Mirror. Introduction. Product Data Sheet. Bi-directional data flow. Easy configuration. Fast data transfer. OPC Data Access compliant

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

RM4TG20 three-phase network control relay RM4-T - range V

DeltaV v11 and v12.3 Supported Computers

NFF Series. CoolX600 NFF Series Cool. Patented Resonant Technology. NFF Series; No Fan Featured

Smart Card Two Factor Authentication

Backup and Recovery. Backup and Recovery. Introduction. DeltaV Product Data Sheet. Best-in-class offering. Easy-to-use Backup and Recovery solution

DeltaV Operator Keyboard

Wireless Remote Video Monitoring

Foxboro Evo Process Automation System

Windows Operating System Upgrade Kits

IO-DIM6 6-Channel, Digital to Analogue Converters

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

Redundancy Module QUINT-DIODE/40

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

AXIS T81B22 DC 30W Midspan

1756 ControlLogix Power Supplies Specifications

Bailey to DeltaV Systems Connectivity

DeltaV Remote Client. DeltaV Remote Client. Introduction. DeltaV Product Data Sheet. Remote engineering and operator consoles

Solid State Timers Type F

Digital input modules

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Cisco Nexus 7000 Series Power Supply Modules

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

MLC TM Maximum Productivity and Versatility for Control without Compromise!

DeltaV Virtualization High Availability and Disaster Recovery

How To Power A Power Supply Shelf With A Power Unit (Hp 2920)

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

1701/22 FieldMonitor Management Interface Module

Automation Unit TM 1703 ACP Flexible automation and telecontrol

D1U54P-W HxxC Series 54mm 1U Front End AC-DC Power Supply Converter PRODUCT OVERVIEW FEATURES

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

ProfessionalPLUS Station Software Suite

XLReporter for DeltaV Analyze

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

SINEAX U553 Transducer for AC Voltage

Antec TruePower User's Manual

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

CQM1-SF200/CS1W-SF200

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

SURGE PROTECTIVE DEVICES

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Transcription:

January 2013 Page 1 The DeltaV S-series DC/DC system power supplies are modular, easy to install, and secure Easy to use Flexible and cost-effective Secure Simplified system power Introduction Power your system won t operate without it. DeltaV system power supplies offer you the most efficient and reliable power solution for your money. The DeltaV S-series DC/DC power supply connects to your bulk 24VDC power to provide power to the system electronics including the controller and associated I/O cards. This is all the power required for your DeltaV system. www.deltav.com

January 2013 Page 2 Benefits Easy to use. The SE5009 DC/DC system power supplies are plug-and-play components. They fit into S- series power supply/controller carriers that contain internal power buses to both the controller and I/O interfaces, eliminating the need for external cabling. The carrier mounts easily onto a T-type DIN rail easy! Flexible and cost-effective. The SE5009 DC/DC system power supply accepts 24 VDC input power. The modular architecture and the power supply s load-sharing capabilities enable you to add more power or provide power redundancy to your system. Secure. Your I/O is always accurate because the I/O subsystem and controller always receive a consistent and accurate 12- or 5-VDC power supply. The power supplies are compliant with EMC and CSA standards; they provide immediate notification of power failure; system and field power provisions are completely isolated. Simplified system power. The SE5009 system power supply delivers more current to the 12-VDC I/O interface power bus and eliminates the need for injected power supplies. Now, all your controller and I/O power can be sourced from plant 24-VDC bulk power supplies. Product Description The S-series SE5009 DC/DC system power supply is used to power the DeltaV controllers and I/O interfaces from 24 VDC bulk power. It can be mounted next to the controller on a Power/Controller carrier and provide the 5 VDC required by the controller. It also provides up to 8 Amps of 12 VDC power to the I/O interfaces. Plug-and play components. The system power supply components fit into any power supply slot of any DeltaV power/controller carrier. This makes system design easy and the interchangeability reduces spares inventory. 1 Modular power. You know your power requirements today, but what about the future? Lay a solid foundation now and build on it later. The modular power structure allows you to install additional power to the controller and I/O subsystems. Accurate output. The SE5009 system power supplies accept a variance in the input 24 VDC of +/- 20% and still generate accurate power output. Power redundancy. DeltaV system power supplies can be redundant at 1-to-N versus 1-to-1 in other systems. This provides an economical solution to creating system redundancy. Fault detection. Both under and over-voltage conditions are detected and recorded to protect the controller and I/O subsystem, and to enable automatic cold restart of the controller in case of bulk power supply failures. Standard compliance. The power supplies are compliant with EMC and CSA standards. Their design meets the new European power factor correction standards. Immediate notification of power failure. Internal relay outputs change status and alert the user if the incoming voltage fails or if the system power supply fails. Also, the LED on the power supply housing displays the power status. System and field power isolation. The system power supply provides isolation between the system power and field power when both are powered from the same 24 VDC bulk power supply system. Power supply removal. System power supplies are easy to remove/replace. Bulk power wires are attached to S-series carrier power terminals. Rail mounted. Power supply installation is simple. Mount the power/controller carrier into place on a T-type DIN rail. Then plug the system power supplies into the carrier. Internal power bus. The power/controller carrier contains internal power buses. You don t need to use external cabling to connect the system power supply to the DeltaV controller and the I/O interface carriers. 1 Refer to Zone 2 installation instructions (12P2046) and/or Class 1 Division 2 installation instructions (12P1293) for details.

January 2013 Page 3 24-VDC System Power Supply The SE5009 system power supply eliminates the need for bulk 12 VDC power supplies by delivering up to 8 amps to the LocalBus. System power is isolated from the 24 VDC field power. Description 24 VDC System Power Supply Specifications Input 24 VDC ± 20% at 6.1A Inrush (soft start) Output Power Rating -40-60C Output Power Rating 60-70C Input protection 20 A peak maximum for 5 ms over 24 VDC input range (including 12 VDC output) +12 VDC at 8.0 A (24 VDC Input) +5 VDC at 2.0 A (10 W total for combined outputs of +5 VDC) +12 VDC at 6.0 A (24 VDC Input) +5 VDC at 2.0 A (10 W total for combined outputs of +5 VDC) Internally fused, non-replaceable Overvoltage protection Output protected at 110% to 120% Hold-up time Output: remains within 5% of nominal at full load and minimum input voltage for 5 ms (excluding 12 VDC current with 12 VDC input) Operating temperature Storage temperature Relative humidity Airborne contaminants Shock Vibration Mounting -40 to 60 C (-40 to 140 F) without de-rating 60 to 70 C (140 to 158 F) with de-rating -40 to 70 C (-40 to 158 F) 5 to 95%, non-condensing ISA-S71.04-1985 airborne contaminants class G3 10 g ½-sine wave for 11 ms 1 mm peak-to-peak from 5 Hz to 13.2 Hz, 0.7 g from 13.2 Hz to 150 Hz On either slot of 2-wide power/controller carrier, power slot of VerticalPlus 4-wide carrier, any slot of 4-wide power carrier. LED Indicators: Green DC Power Red Error Input DC power is applied and internal fuse/diode is sound. The +5 VDC outputs are out of tolerance. External connectors: Primary power Alarm contact DC input, 2-wire 2-wire normally open relay; relay is closed when 3.3 and 5 VDC outputs are within ±4% of nominal; 2.0 A at 30 VDC, 2.0 at 250 VAC Power Calculations One SE5009 system power supply provides up to 8.0 amps. Refer to the DeltaV hardware installation manual for details on system power calculations and how to inject additional I/O interface power.

January 2013 Page 4 Certifications The following certifications are available on the S-series DC/DC System Power supply. CE: - EMC- EN 61326-1:2006 - LVD- EN 61010-1:2001 CSA: - CLASS 2252 05 - PROCESS CONTROL EQUIPMENT: CAN/CSA-C22.2 No. O-M91 General Requirements- Canadian Electrical Code, Part II CAN/CSA-C22.2 No. 61010-1-04 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use, Part 1: General Requirements The following certifications have been submitted for Hazardous Locations and for Marine applications. Please verify with the appropriate certifying agency for a specific list of approved components Marine Certifications: IACS E10:2006 Rev.5 Control, protection & Safety - ABS Certificate of Design Assessment - Bureau Veritas Certificate - DNV Marine Certificate - Lloyds Register GOST Hazardous Area certification Zone 2 (Russian) Other country specific certifications may also be available. Verify with your local Emerson sales office to confirm any certification requirements not listed here. Complies with NAMUR NE21 per DeltaV Digital Automation System NAMUR NE21 Installation Instructions 12P2822. CENELEC Zone 2 ATEX/IEC EX EN 60079-15:2005 Certifying agency: Nemko Certificate Number: TBD Refer to document TBD "DeltaV Scalable Process System Zone 2 Installation Instructions" FM Approval Class 1 Division 2 Hazardous Locations Certifying agency: FM Approvals Certificate Number: TBD Refer to document TBD "DeltaV Scalable Process System Class 1 Division 2 installation Instructions

January 2013 Page 5 Ordering Information Description 24VDC System Power Supply SE5009 Model Number Prerequisites DeltaV v11.3 or later. Compatible with S-series Horizontal carriers. To locate a sales office near you, visit our website at: www.emersonprocess.com/deltav Or call us at: Asia Pacific: 65.6777.8211 Europe, Middle East: 41.41.768.6111 North America, Latin America: +1 800.833.8314 or +1 512.832.3774 For large power, water, and wastewater applications contact Power and Water Solutions at: www.emersonprocess-powerwater.com Or call us at: Asia Pacific: 65.6777.8211 Europe, Middle East, Africa: 48.22.630.2443 North America, Latin America: +1 412.963.4000 Emerson Process Management 2013. All rights reserved. For Emerson Process Management trademarks and service marks, go to: http://www.emersonprocess.com/home/news/resources/marks.pdf. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warrantees or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the design or specification of such products at any time without notice. www.deltav.com