User Operating Instructions Horstmann 425 Coronet Electro-mechanical Timeswitch



Similar documents
Installation & User Instructions

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

TIMERS AND CONTROLS ELECTRONIC 7 WATER HEATER CONTROLLER FOR ECONOMY 7 AND WHITE METER TARIFFS USERS OPERATING INSTRUCTIONS

SET3M. electro-mechanical 24 programmer for heating & hot water. Installation & User Instructions

Drayton Digistat +2RF

Users Instructions BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER

A Class Air Source Heat Pump User Guide

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Wireless 7 Day Programmable Room Thermostat

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

MAKING MODERN LIVING POSSIBLE. Electronic 7 Day Programmable Room Thermostat TP7000 Range. User Guide. Danfoss Heating

User's Instructions. Alpha HE CB25/33 and HE SY25

User Manual THR840DUK Digital Thermostat

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

CM927 - User Guide. Description. Features. 7 day Wireless Programmable Room Thermostat with LoT Technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

Comfort Compact Controller ZG 215N

BoilerMate SP. benchmark. user instructions A - C L A S S

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump

Guidance on how to comply with the 2010 Building Regulations Part L

Article: Version:

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

T-4000 Series Room Thermostat Adjusting Instructions*

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

EK908FHL - Thermostat for floor heating

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

Fused Spur Time Switch

HEAT PUMP PROGRAMMABLE THERMOSTAT

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

Hi-Spec. sustainable solutions under one roof HEATING HOT WATER VENTILATION. Warm Air Heaters. with System E-T & Basic Control USERS INSTRUCTIONS

Carrier Thermostat Quick Reference Guide

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Baxi Combi 80e & 105e

Wireless Thermostats 230v and Battery Operated Instruction Manual

CR9986 ROBERTS. Dual Alarm CD Clock Radio. Sound for Generations. Please read this manual before use

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

INSTALLATION INSTRUCTIONS MC95HAE-1 MASTER CONTROLLER

Operation Guide 3M-22

Mini Timer Owner's Manual. Model MT13A

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

Energy Tutorial: Energy Usage. Reading meters and understanding fuel bills

Fully Pumped Systems

Operating Instructions. Room temperature controller

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

Control Location. Replacing Battery

EP ; WO2012/080751; GB

Trinchero Family Estates Building: Operation User s Guide

climote User Guide Version 1-0

WARRANTY AND DISCLAIMER

NOTE: Append this Operation IB to the Install IB to make one IB-booklet. Need a divider tab between the 2 sections. Blank page remove.

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

SHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM

ATS-505. GB Version 1

Digital Radio/DAB+/FM RDS digital clock radio with dual alarm Operating instruction

Guidance on how to comply with the 2013 Building Regulations Part L

TISSOT TWOTIMER SETTING INSTRUCTIONS

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

GETTING STARTED WITH THE MIPOWER MANAGEMENT SYSTEM

Combi Eco Elite Range. User s Guide and Important Warranty Information

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat

For installation guide see reverse of book

Transfer Equipment Controls

Using Time-of-Day Scheduling To Save Energy

User Guide. Titanium Combi Condensing Combination Boiler

USER MANUAL. Issue 3 - December Manual Stock No Software Version 3.0 Zero 88 Lighting Ltd. 2003

Mode Switch. Fan Switch Menu button Program button

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

End User Manual. microgenus II 24 MFFI microgenus II 28 MFFI microgenus II 31 MFFI. Country of destination: GB/IE E C

Operating instructions

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers

User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

INSTRUCTIONS FOR USE. Cal. ETA ¾ x 11½ Cal. ETA x 11½. English

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

Operating instructions

ETS - Electric Thermal Storage Heating

9452/9453 Installation and User Guide

AQUAREA USER GUIDE FOR BI-BLOC, MONOBLOC & ALL IN ONE

Owner s Manual. Model 8476 Thermostat with Event-Based Air Cleaning. Includes Operating Instructions and Warranty Information

Combi 24 HE. User s Guide and Important Warranty Information

Combi 30 HE. User s Guide and Important Warranty Information

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

GB/DAS User Instruction

Installation Guide for Hive Active Heating

USER GUIDE SERIES 4250 AUDIO ALARM CONFIRMATION SYSTEM CONTROL UNIT

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

Transcription:

User Operating Instructions Horstmann 425 Coronet Electro-mechanical Timeswitch The Horstmann 425 Coronet timeswitch is a single circuit central heating timeswitch able to switch ON and OFF twice every 24 hours. An advance switch is provided to make temporary overrides to the ON or OFF periods and a selector switch gives a further choice of programmes. 1

The 425 Coronet Timeswitch The simple instructions contained in this user guide are designed to help with the programming and operation of these units. DIAL TAPPETS PROGRAMME SELECTOR TIME POINTER ADVANCE CONTROL 2

SETTING THE TIME OF DAY The dial rotates clockwise and makes one complete revolution every 24 hours. To set the correct time turn the dial clockwise by hand (using the levers on the clock face) until the correct time of day is against the line marked TIME. (See diagram opposite) SETTING THE ON/OFF TIMES The four setting tappets, coloured red and blue, are moved around the circumference of the dial to set your required ON and OFF times. These tappets work in pairs to switch the system ON and OFF. - No 1 (red) 1st ON and No 2 (blue) 1st OFF - No 3 (red) 2nd ON and No 4 (blue) 2nd OFF The tappets may be moved in either direction. (See diagram) Please ensure that you press and hold down any tappet that is to be moved, release tappet only once correct time position has been reached. Tappets cannot be moved across the Time line. The position of the dial may have to be altered to set the initial ON/OFF time. Please ensure the clock is set to the correct current time after altering the ON/OFF settings. LIGHTLY PRESS DOWN ON No 1 TAPPET. MOVE TAPPET UNTIL REACHING THE DESIRED ON TIME LIGHTLY PRESS DOWN ON No 2 TAPPET. MOVE TAPPET UNTIL REACHING THE DESIRED OFF TIME REPEAT PREVIOUS INSTRUCTIONS FOR 2nd ON/OFF SETTINGS. USING TAPPETS 3 AND 4 MOVE THE PROGRAMME SELECTION SWITCH TO THE REQUIRED POSITION 3

Manual Overrides ADVANCE CONTROL The advance control allows you to start an ON or OFF period early without altering the tappet, time or programme selection settings. Moving the advance control to the extreme right brings forward the operation of the next tappet. The switch state indicator then changes to the appropriate number. When the next tappet passes the time line, normal operation returns. When the programme selector is in the All Day position, tappets 2 and 3 do not operate. If you require switching the system OFF for the day, after the morning switch ON, you will need to step forward with the advance switch until the number 4 is shown in the switch state indicator. If you wish to switch ON and OFF by hand or vice versa, before the next automatic switching operation, the advance control must be operated until the switch state indicator is returned to the correct automatic sequence. EXAMPLE: If you turn the system ON again after the preset night shut down time, when you turn it OFF before retiring make sure to operate the advance switch again until the number 4 is displayed in the switch state indicator so that the red tappet number 1 will switch the system ON in the morning. DO NOT OPERATE THE ADVANCE SWITCH WHEN A TAPPET IS AGAINST THE TIME LINE. SWITCH STATE INDICATOR SWITCH STATE INDICATOR Located above the ADVANCE switch, the switch state indicator shows you the number of the tappet which operated last. Eg. If the system was switched ON by tappet 1 at 7:00am and it is now 9:00am, providing that no further tappets operations have past, a number 1 should show in the aperture. If the switch state indicator does not agree with the programme set on the dial, rotate the dial one whole turn and reset to the correct time of day. This will ensure that the switch state corresponds to the last tappet operation. 4

PROGRAMME OVERRIDE FACILITIES The following programme options are available: 24 Hrs - The system will be permanently ON All Day - The system will switch ON from tappet 1 (red) and OFF at tappet 4 (blue) Tappets 2 and 3 are ignored Twice - The system switches ON at tappet 1 (red), OFF at tappet 2 (blue), ON at tappet 3 (red) and OFF at tappet 4 (blue) Off - The timer continues to operate but the system will be permanently OFF 5

What is a programmer?... an explantion for householders. Programmers allow you to set On and Off time periods. Some models switch the central heating and domestic hot water on and off at the same time; while others allow the domestic hot water and heating to come on and go off at different times. Set the On and Off time periods to suit your own lifestyle. On some programmers you must also set whether you want the heating and hot water to run continuously, run under the chosen On and Off heating periods, or be permanently off. The time on the programmer must be correct. Some types have to be adjusted in Spring and Autumn at the changes between Greenwich Mean Time and British Summer Time. You may be able to temporarily adjust the heating programme, for example, Override, Advance or Boost. These are explained in the manufacturer s instructions. The heating will not work if the room thermostat has switched the heating off. And, if you have a hot-water cylinder, the water heating will not work if the cylinder thermostat detects that the hot water has reached the correct temperature. The above explanation also applies to your timeswitch, which operates as a single circuit programmer. Service and Repair This programmer is NOT user serviceable. Please do not dismantle the unit. In the event of a fault developing please contact a local heating engineer or a qualified electrician Horstmann Controls Limited South Bristol Business Park, Roman Farm Road, Bristol BS4 1UP E-mail: sales@horstmann.co.uk Web site: www.horstmann.co.uk 6 Leaflet number P83664 Issue 1