Operation and Service Guide: Showers



Similar documents
Thermostatic Valve Replacement Cartridge and Rebuild Kit

Installation Instructions

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9)

Installation Instructions S

Stainless Steel Single and Dual Circulation Kits

Installation Instructions

Installation Instructions / Warranty

Installation Instructions / Warranty

White Industries Rear Hub Instructions

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

Installation Instructions

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER

Installation Instructions

STEERING SYSTEM - POWER

TECHNICAL SERVICE MANUAL

Installation Instructions / Warranty

16001 cross - pair lever - pair pair w/wrench cross - pair lever - pair

MP8000 Series Pneumatic Valve Actuators

IF IT FLOWS THE BOWIE PUMP CAN PUMP IT

BOWIE PUMPS OPERATION - MAINTENANCE

Price Book - Section 20 Miscellaneous

Round Housing with Side Ports

PVM Piston Pumps Service Manual

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

Installation Instructions

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

CARING FOR YOUR NEW BATH FITTER UNIT

Tri-Homo Style Operation and Maintenance Instructions

IMPORTANT DOCUMENTATION DO NOT DISCARD!

Welding Reel ERA 4000 Service Manual

Cleaning & Sanitisation

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

Installation Instructions

TUTORIAL. REbUILdING. front CALIpER O-RING CONVERSION CORVETTE Part #: HT-1

Atlas Front Input Change

UNITS Units are designated by the unmounted pump model numbers followed by a letter indicating drive style.

SERIES 127A AND 4127A STAINLESS STEEL SIZES H, HL, K, KK, L, LQ, LL CONTENTS UNMOUNTED PUMP UNITS

FLUSHOMETER - TANK SYSTEM

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

2006 HEADSHOK Service Video #1

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

AXLE SHAFTS - FRONT Pontiac Bonneville MODEL IDENTIFICATION DESCRIPTION & OPERATION TROUBLE SHOOTING REMOVAL & INSTALLATION

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

IMPACT SPRINKLER TROUBLESHOOTING GUIDE

MODEL G300 BRAKE BLEEDER

This instruction is valid for all ACD pump models shown on page 2

TUTORIAL. REbUILdING. REAR CALIpER O-RING CONVERSION CORVETTE Part #: HT-2

INSTALLATION INSTRUCTIONS

Before repairing your toilet, you must determine

MP-4V Heavy Duty Riveter / 39048

1.8 CRANKSHAFT OIL SEALS

A-4000 Oil Indicator

ACCUMULATOR INSTALLATION

5800 Temperature Sensor Cable Assembly

S&G Model 2937 Group 1 Combination Lock

DANA 30 MANUAL HUB CONVERSION KIT

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

PVH131/141 Variable Displacement Piston Pump - 11 Design

CW-4622 INSTALLATION INSTRUCTIONS CB-4622 RISER KIT TO SUIT BLACK LEVER EXPOSED VALVES & BATH/SHOWER VALVES

Chill 4 Hole Bath Shower Mixer

Fisher CV500 Rotary Globe Control Valve

Viking Pump with Motor and Gear Reduction Drive

TOP AND CABINET PARTS For Models: WTW5500XW0, WTW5500XL0 (White) (Silver)

Installation Instructions

NAIAD INFLATABLES (NZ) LTD

DYNA RIDER FOOTBOARD KIT

Drive shaft, servicing

SHOWERS SHOWERS

Speed-Mat Rectangle Cutter

INSTALLATION INSTRUCTIONS BL-8704

TOP AND CABINET PARTS

Beam Laser Pointer Service Manual

MG1532 & MG2032 MIXER-GRINDERS

PArt# spout Length Adjusts /2 to 8-1/ /2 to 8-1/ /2 to 8-1/ /2 to 8-1/2. PArt# FIts Adjusts

Technical Information

1 Important Safety Procedures. Qualified maintenance personnel should read and follow these straightforward instructions.

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Zipp 60 & Zipp 30 Service Manual

INSTALLATION INSTRUCTIONS MK-8704

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Important Information

Parts#MB Reverse Gear MAMBA (Monoblock for Cable operated) For 5 speed Trans., '87 to '06 Big Twin models (except '06 Dyna)

Fire Hydrant Troubleshooting

Dive Rite 200 & 300 Bar Isolator Manifold Service Manual

Trouble Shooting Tech Tips Operation

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Fixtures - Parts - Accessories to shampoo bowls

TC 170 & TC 170 PD TRANSFER CASE

Repair of Hyd-ro-ac Actuators

INSTALLATION & OPERATING INSTRUCTIONS

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

INSTALLATION INSTRUCTIONS

Trunnion-Design Ball Valves

Transcription:

Equa-Flo Shower Valve, Version Prior to March, 00 Operation and Service Guide: Showers P.O. Box 309 Menomonee Falls, WI 5305-0309.800.BRADLEY Fax: 6.5.587 bradleycorp.com For Individual, Econo-Walls, Wall Savers, Panelons and Column Showers NOTE: Should the rotor come off the stem, align groove in outer rim of rotor with groove in spline on the stem when reassembling. Also, if you should wish to reverse hot for cold and cold for hot due to install error, or back to back installation, you can reassemble rotor 80 against stem and valve will work properly. Column Type Showers Wall Type Showers 300-39 (Individual) 300-7 (Wall Saver) 300-38 (Panelon & Econowall) 3 0 3 5 6 Escutcheon Screws: () 60-78 7 9 8 0 3 5 7 6 8 Escutcheon Screws () 60-78 9 50-093 (6 person) 50-09 (-5 person) (NOTE: These parts have a satin finish with etched lettering) Valves are equipped with a temperature limit stop which can be used to limit the temperature of tempered water discharged. To adjust the temperature, remove the handle and loosen the set screw. remove the limit stop and reposition to desired setting. Turn the limit stop clockwise for a hotter setting and counterclockwise for a cooler setting. Note: When replacing the double face seals, lubricate the top face with a small amount of lubricant reassembling. Equa-Flo Shower Valve PRIOR to March, 00 When assembling cap into valve body, use lubricant on 69-03 O-ring to prevent twisting of O-ring. If lubricant is not available, a slight film of soap may be used. of 5 Bradley Corporation 5-369-5 Rev. E: EN 06-306

P.O. Box 309 Menomonee Falls, WI 5305-0309.800.BRADLEY Fax: 6.5.587 bradleycorp.com Equa-Flo Shower Valve Parts List, Version Prior to March, 00 (Figure 0) Item Part No. Description Assembly Catridge Assembly S67-359 Stem Assembly S-065 Gasket Repair Kit S65-073 5-055 Square Ring (In Rear) S55-009 Sleeve & Flapper (Ear must fit into groove) 3 8-5 Cartridge Housing 5-08 Double-face Seal 5 0-0 Rotor 6 0-33 Stem 7 35-08 Spring 8 5-053 Washer 9 5-00BH O-Ring 0 69-03 O-Ring 07-80 Cap/Clamp 60- Screws 3 07-79 Cover 5-00CY O-Ring 5-0 OFF Stop 6-033 Hot Limit Stop 7 60-5 Set Screw 8 8-07 Handle 9 60- Screw 0 5-00BS Gasket 8-3 Valve Body 69-69 Top Seat Gasket 3 69-56 Screws 73-05 Screens (Internal) 5 S7-0 Stops (Optional) Qty Complete Column Valve Replacement for Columns Built Prior to March, 00: S65-075 for -5 Person S65-076 for 6-Person Equa-Flow Shower Valve PRIOR to March, 00 of 5 Bradley Corporation 5-369-5 Rev. E: EN 06-306

P.O. Box 309 Menomonee Falls, WI 5305-0309.800.BRADLEY Fax: 6.5.587 bradleycorp.com Equa-Flo Shower Valve, March, 00 to July, 00 (Figure 0) For Individual, Econo-Walls, Wall Savers, Panelons and Column Showers NOTE: Should the rotor come off the stem, align groove in outer rim of rotor with groove in spine on the stem when reassembling. Also, if you should wish to reverse hot for cold and cold for hot due to install error, or back to back installation, you can reassemble rotor 80 against stem and valve will work properly. Column Type Showers Wall Type Showers 300-0 (Individual & Econowall) 300- (Panelon) 300-7 (Wall Saver) 3 0 3 5 6 Escutcheon Screws: () 60-7 Figure 0a 9 8 0 3 5 7 6 8 Escutcheon Screws () 60-78 9 50-06 (6 person) 50-05 (-5 person) (NOTE: These parts have a chrome finish with cast-in recessed lettering) Valves are equipped with a temperature limit stop which can be used to limit the temperature of tempered water discharged. To adjust the temperature, remove the handle and loosen the set screw. remove the limit stop and reposition to desired setting. Turn the limit stop clockwise for a hotter setting and counterclockwise for a cooler setting. Note: When replacing the double face seals, lubricate the top face with a small amount of lubricant reassembling. Equa-Flo Shower Valve March, 00 to July, 00 When assembling cap into valve body, use lubricant on 69-03 O-ring to prevent twisting of O-ring. If lubricant is not available, a slight film of soap may be used. 3 of 5 Bradley Corporation 5-369-5 Rev. E: EN 06-306

P.O. Box 309 Menomonee Falls, WI 5305-0309.800.BRADLEY Fax: 6.5.587 bradleycorp.com Equa-Flo Shower Valve Parts List, March, 00 to July, 00 (Figure 0) Item Part No. Description Assembly Catridge Assembly S67-359 Stem Assembly S-065 Gasket Repair Kit S65-073 5-055 Square Ring (In Rear) S55-009 Sleeve & Flapper (Ear must fit into groove) 3 8-5 Cartridge Housing 5-08 Double-face Seal 5 0-0 Rotor 6 0-33 Stem 7 35-08 Spring 8 5-053 Washer 9 5-00BH O-Ring 0 69-03 O-Ring 07-80 Cap/Clamp 60- Screws 3 07-79 Cover 5-00CY O-Ring 5-0 OFF Stop 6-033 Hot Limit Stop 7 60-5 Set Screw 8 8-07 Handle 9 60- Screw 0 5-00BS Gasket 8-3 Valve Body 69-69 Top Seat Gasket 3 69-56 Screws 73-05 Screens (Internal) 5 S7-0 Stops (Optional) Qty Complete Column Valve Replacement for Columns Built March, 00 to July, 00: S65-35 for -5 Person S65-36 for 6-Person Equa-Flow Shower Valve March, 00 to July, 00 of 5 Bradley Corporation 5-369-5 Rev. E: EN 06-306

Adjusting the Equa-Flo Valve Operation and Service Guide: Showers P.O. Box 309 Menomonee Falls, WI 5305-0309.800.BRADLEY Fax: 6.5.587 bradleycorp.com NOTE: The maximum temperature limit stop has been preset by the factory for maximum temperature operation. For temperatures other than the maximum, the stop may be repositioned as shown below. IMPORTANT: Failure to adjust the maximum temperature limit stop to a safe shower temperature, no more than 05 F, could result in the user being scalded.. Loosen the setscrew in the bottom of the hot limit stop.. Remove the outer most stop and reposition to the desired temperature setting. NOTE: Do not remove the inner off-stop. A. Position the Temperature Limit Stops as shown for Individual Wall Showers. B. Position the Temperature Limit Stops as shown for Wall-Savers, Panelons and Econo-Walls. C. Position the Temperature Limit Stops as shown for Column Showers. 3. If the desired position falls between adjacent positions on the spline, flip the stop over so that the other face shows. This shifts the stop position by / spline. FOR BACK-TO-BACK INSTALLATION: On the valve that is installed "backwards," rotate the stem 80 so that the "groove in spline" is opposite that shown for tub and shower valves. ESCUTCHEON TO SHOWERHEAD 5 8 9 FOR BACK-TO-BACK INSTALLATION ONLY (GROOVE IN SPLINE) 7 6 TUB & SHOWER VALVES WALL-SAVER VALVES 5 of 5 Bradley Corporation 5-369-5 Rev. E: EN 06-306