Benefits of a Modern SCADA Protocol DNP3 vs Modbus



Similar documents
Keeping SCADA Networks Open and Secure DNP3 Security

Advantages of the DNP3 Communications Protocol in Water and Wastewater Telemetry Systems. By Vishal Prakash

secure Agent Secure Enterprise Solutions Remote Recovery from a Data Center Outage SecureAgent Software

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

Welcome to the Introduction to Controller Area Network web seminar My name is William Stuart, and I am a Applications Engineer for the Automotive

CG Automation Solutions USA

SCADAvantage Network Topology System software products

Barry Baker P. Eng. Asset Data Integration Field Device Communication Protocols

Identifying Gas Ultrasonic Measurement. Problems Using Advanced Techniques. John Lansing CEESI

Client-Server SCADA Technology

Licensing for BarTender s Automation Editions. Understanding Printer-Based Licensing WHITE PAPER

Substation Automation Systems. Nicholas Honeth

Hyperoo 2 User Guide. Hyperoo 2 User Guide

Advanced TDMS Database Training COURSE OUTLINE

Natural Gas Well Automation using Kingfisher RTU Products

Wireless Communications for SCADA Systems Utilizing Mobile Nodes

11 Rules for Specifying a Successful SCADA System By Steve Hill

Introduction To SCADA and Telemetry

EZ-View Network Communications Guide

R-Win. Smart Wireless Communication Management System

SICAM PAS - the Key to Success Power Automation compliant with IEC and your existing system

Field Products. Experion LX. Proven, Easy to Use and Purpose-built Distributed Control System

Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry.

Alert ALARM MANAGEMENT

Measuring IP Performance. Geoff Huston Telstra

CONTROL MICROSYSTEMS DNP3. User and Reference Manual

Secure SCADA Communication Protocol Performance Test Results

Central Station Interface with Fire Alarm and the Relevant Codes & Standards

WISE-4000 Series. WISE IoT Wireless I/O Modules

Section TELEPHONE AUTOMATIC DIALER SYSTEM

How To Set Up A Modbus Cda On A Pc Or Maca (Powerline) With A Powerline (Powergen) And A Powergen (Powerbee) (Powernet) (Operating System) (Control Microsci

Advantech WebAccess Device Driver Guide. BwSNMP Advantech WebAccess to SNMP Agent (Simple Network Management Protocol) Device Driver Guide

SCADA Questions and Answers

Improving SCADA Operations Using Wireless Instrumentation

Additional Setup Instructions for Modbus: RTU, ASCII, TCP, Omni & Enron

Wireless LAN Concepts

White Paper ClearSCADA Architecture

Monitoring & Control of Small-scale Renewable Energy Sources

SCADA Solutions KEEPING YOU CONNECTED ANY TIME, ANY PLACE.

Overcoming IP Address Issues with GPRS Remote Monitoring and Alarm Systems

DNP Points List and Implementation

Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations

DATRAN RTU Data Logging

White Paper. Technical Capabilities of the DF1 Half-Duplex Protocol

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

Using the DNP3.0 Protocol via Digi Device Servers and Terminal Servers

Final Exam. Route Computation: One reason why link state routing is preferable to distance vector style routing.

What you need to know about cloud backup: your guide to cost, security and flexibility.

Real Time Remote Monitoring over Cellular Networks. Wayne Chen Marketing Specialist

A DNP3 Protocol Primer

HMS Industrial Networks

SCADA PERFORMANCE COMPARISON MODBUS SIMULATION

Proposal for Online Backup

PROFIBUS AND MODBUS: A COMPARISON

RcWare SoftPLC Modbus server mapping editor User manual

Design and Implementation of SCADA System Based Power Distribution for Primary Substation ( Monitoring System)

Characterizing Performance of Enterprise Pipeline SCADA Systems

ENTELEC 2002 SCADA SYSTEM PERIODIC MAINTENANCE

TOP Server DNP 3.0 Suite. Background & Best Practices

PROFIBUS/PROFINET System design

Preventing Cyber Security Attacks Against the Water Industry

SCADA Systems Automate Electrical Distribution

Remote Monitoring and Satellite Communications

TIME WARNER CABLE S GUIDE TO USING CUSTOMER-OWNED EQUIPMENT WITH CABLE SERVICES

Protection Ripple in ERP WLANs White Paper

Lumension Endpoint Management and Security Suite. L.E.M.S.S. AntiVirus v8.2. Migration Guide & Frequently Asked Questions

STUDENT ADMINISTRATION TRAINING GUIDE TROUBLE SHOOTING WAIT LISTS

WHITE PAPER: TECHNICAL OVERVIEW. NetBackup Desktop Laptop Option Technical Product Overview

SCADA System Fundamentals

PIPELINE ENGINEERING - Pipeline System Automation and Control - C. Bruce Warren and Mike S. Yoon PIPELINE SYSTEM AUTOMATION AND CONTROL

Scheme to Secure Communication of SCADA Master Station and Remote HMI s through Smart Phones

Information Delivery for Remote Monitoring Systems

Smart Solutions for Network IP Migration

VoIP network planning guide

Ethernet/IP Explicit Messaging Using Unity Software

Quick installation guide for the Vista Quantum QNVR Network Video Recorder

SCADA Systems. Make the most of your energy. March 2012 / White paper. by Schneider Electric Telemetry & Remote SCADA Solutions

Terminology and Scripts: what you say will make a difference in your success

3 Steps to an Effective Retrospective December 2012

Analysis of TCP Performance Over Asymmetric Wireless Links

Your guide to ANZ Home Loans. Be certain about your choice

SCADAPack E DNP3 Technical Reference

UL s Perspective on IP Signaling Larry Shudak Principal Engineer Signaling and Security Control Equipment Underwriters Laboratories Inc.

Input / Output and I/O Strategies

FEATURE GUIDE AeroSphère / Small / Large / Base

How to Use SNMP in Network Problem Resolution

DVR GUIDE. Using your DVR/Multi-Room DVR WAVE-123 wavebroadband.com

Grid Automation Products. MicroSCADA Pro for substation automation

OSI Reference Model: An Overview

Bluetooth Web Enabler

Packetized Telephony Networks

Remote Automation and Monitoring: PLC or RTU?

Introduction to Metropolitan Area Networks and Wide Area Networks

B2BE Transaction Delivery Network

ARCHITECTURE OF INDUSTRIAL AUTOMATION SYSTEMS

How can I Utilize telemetry and remote SCADA architecture for distributed infrastructure?

Transcription:

Benefits of a Modern SCADA Protocol DNP3 vs Modbus November 07

Benefits of using modern protocols for SCADA A protocol is simply the rules that govern the data transfer between parts of a control system. Different protocols have varying strengths and weaknesses. This document looks at the ideas behind good protocols for the users of SCADA / telemetry systems. This is an area often neglected by users when first investing in a SCADA system, as they are often happy to get any data from remote stations. However, it is important to give protocol choice proper consideration. DNP3 provides distinct advantages over Modbus and other protocols, even for the average user. Users will usually conclude that the advantages of DNP3 outweigh the additional initial investment. If you don t want to lose valuable data, or carry out extensive detective work to assess whether trends and reports are demonstrating system problems, station problems or communication problems, then you need a protocol that reliably reports all changes from the field. Data from the field as trended on the SCADA front end 10:01:00 10:05:00 10:10:00 10::00 10::00 10::00 10::00 10::00 10::00 Figure 1 Example 1 Level Trend 70 60 50 Level, % Level 10 0 10:05:00 10:11: 10:18:00 10:22:00 10:24:00 10:29:00 10::00 10:38: 10:43:00 10:49:00 10:52:00 Time 10:54:00 10:58:00 11:03:00 11:07:00 11:09:00 11::00 11::00 Figure 2 - Example 2 Page 2 of 8

Level Trend and Pump Running 70 60 50 Level P1 Run 10 0 10:05:00 10:11: 10:18:00 10:22:00 10:24:00 10:29:00 10::00 10:38: 10:43:00 10:49:00 10:52:00 10:54:00 10:58:00 11:03:00 11:07:00 11:09:00 11::00 11::00 Time Figure 3 - Example 3 In example 1, the user might be happy with the view of the field data shown. In the other two examples, the user might start to look for the source of the problem. Example 2 shows that the start and stop levels are not always the same, though they were expected to be. Is the control circuit working effectively? Are there delays which are in operation at certain times? In example 3, the user will be trying to determine how the level dropped while no pump was working. In examples 2 and 3 the user might in the end consider SCADA communications as being the real problem either the comms architecture or temporary radio problems. 10:05:00 10:07:00 10:09:00 10:11:00 10:13:00 10::00 10:17:00 10:19:00 10:21:00 10:23:00 10::00 10:27:00 10:29:00 10:31:00 10:33:00 10::00 10:37:00 10:39:00 Example 1 The real data, compared with the sample above. Page 3 of 8

Example 1, the user might never realize that in fact the process parameter varied significantly. This might be an indication of serious problems that need to be rectified. In each case, the problem has been caused by communications from the field device to the SCADA system. Note that field devices which communicate back to a SCADA system are known as RTUs (remote telemetry unit). Sometimes these RTUs can simply be sending I/O; in other instances the RTU might combine the communications device with some functionality, such as a dedicated pump controller. Example 1 Problems of Modbus for remote communications Example 1 is a typical example of the problems that are encountered when the protocol from the field is Modbus. In a typical Modbus setup, the master telemetry unit (MTU) which is connected to the SCADA polls each device in the field in turn. At the time a remote device is scanned it simply provides the current value of each register scanned. So example 1 shows a device that has been scanned every 5 minutes. Improvements can be made by increasing the scan speed putting in faster radios or running more radio channels. But this doesn t really address the main issue collecting data that has changed. The user might guess how often field devices or certain registers need to be scanned, but then again, that presupposes that they fully understand the dynamics of their system in every scenario. The SCADA system might prevent them from learning what is really happening, rather than educating them about the system. Compare the real data with the sampled data once again: 10:05:00 10:07:00 10:09:00 10:11:00 10:13:00 10::00 10:17:00 10:19:00 10:21:00 10:23:00 10::00 10:27:00 10:29:00 10:31:00 10:33:00 10::00 10:37:00 10:39:00 10:01:00 10:05:00 10:10:00 10::00 10::00 10::00 10::00 10::00 10::00 Figure 4 Real data Figure 5 Trend when Modbus protocol used Page 4 of 8

Example 2 Sending data on change So a protocol which simply polls periodically to capture the current snapshot is not a good protocol. How about a protocol which sends data on change? Level Trend 70 60 50 Level, % Level 10 0 10:05:00 10:11: 10:18:00 10:22:00 10:24:00 10:29:00 10::00 10:38: 10:43:00 10:49:00 10:52:00 Time 10:54:00 10:58:00 11:03:00 11:07:00 11:09:00 11::00 11::00 Figure 6 Example 2 Example 2 shows a problem that still occurred with a protocol of this nature. The problem here is that the highest and lowest level are only present for maybe 10 seconds. The particular protocol (a manufacturer s protocol) initiates a data transmission when the level changes. However, if the radio network is temporarily congested and in a point to multi-point radio network this may be true a lot of the time then the device waits until a clear to send is indicated by the radio. If it takes more than 10 seconds before the radio channel becomes clear for that device, then it will send the current value. So by the time the channel is clear, the value has changed again and only the new value is sent. Example 3 Comms failing The other problem that can occur with protocols that send data on change is what happens when the radio or communications device fails? Example 3 occurred because some occasional radio problems were being encountered. But suppose a radio fails, and it takes 8 hours before it is replaced. What happens when the field device next communicates with the SCADA? It only sends the current snapshot, so all the events and changes that happened for the last 8 hours are lost. Summary of the examples The examples above should indicate why the protocol between the field and the SCADA should be carefully chosen. If you don t want to lose valuable data, or have to carry out extensive detective work to assess whether trends and reports are demonstrating system problems, station problems or communication problems, then you need a protocol which reliably reports all changes from the field. There are some manufacturer s protocols around which carry out these requirements, but these should be avoided otherwise you might find you are locked into one supplier for the next 5 or 10 years. Page 5 of 8

Why DNP3 DNP3 is an open protocol which is supported by a user s group consisting of end-users and suppliers. The protocol was developed to solve the problems that resulted from the use of various protocols like Modbus. 10:05 :00 10:07 :00 10:09 :00 10:11 :00 10:13:00 10::00 10:17:00 10:19 :00 10:21 :00 10:23 :00 10::00 10:27:00 10:29:00 10:31:00 10:33 :00 10: :00 10:37 :00 10:39:00 Figure 7 Real data 10:01:00 10:05:00 10:10:00 10::00 10::00 10::00 10::00 10::00 10::00 Figure 8 Trend when Modbus protocol used 10:05:00 10 :07 :00 10:09:00 10 :11 :00 10:13:00 10::00 10:17:00 10:19:00 10:21:00 10:23:00 10::00 10 :27 :00 10:29:00 10:31:00 10:33:00 10::00 10:37:00 10:39:00 Figure 9 Trend when DNP3 protocol used Page 6 of 8

How does DNP3 work? In brief, DNP3 stores all changes with the date/time stamp of when they occurred. When the RTU communicates with the SCADA (and this can be initiated in a variety of ways) it sends all data which has changed. So even if a radio has been out for 8 hours, it doesn t matter. When communications are restored, all of the data, along with each original date/time stamp will be sent. This also gives the advantage of better use of bandwidth. Instead of capturing a snapshot of every register in every device as often as possible, you capture all changes. So suppose you have a device with 50 parameters (perhaps some I/O and some derived parameters) and over a 5 minute period 49 haven t changed while 1 parameter has changed 4 times. With Modbus you will read 50 values, 49 unchanged, and one which has changed but you will have missed the 3 other changes. When you use DNP3, you will get just the 4 changes from the one I/O point along with the date and time that each change occurred. The other major advantage of DNP3 is that you can assign different events to different classes and treat each class differently. For example, you might assign a high or low level alarm to class 1, and all other events to class 2. Class 1 will be setup to notify the SCADA on change. Class 2 will be periodically polled by the SCADA for all changes. This gives the best of both worlds immediate notification of serious problems, without clogging up the bandwidth with every device trying to communicate every change when it takes place. One last point to make about DNP3 is that it can be set up so that acknowledgements are required from SCADA. This ensures data integrity. This works as follows: the RTU sends the most recent changes to SCADA; it waits for an acknowledgement from SCADA that this data was received ok, otherwise it resends. Security Many manufacturers who have their own protocols claim that they offer better security than an open protocol such as DNP3. In fact, this claim is usually flawed, as it is easy to reverse engineer most protocols unless they specifically encrypt each message to a reasonable encryption standard. In any case, the DNP3 user group has recently released its security specification. Organizations such as MultiTrode will be implementing DNP3 security very shortly. Storing the data in a SCADA system It is possible to have an effective communication system based on DNP3 so that all data is reliably transmitted to the MTU, and still not make use of it. Suppose that the trending system or historian simply samples data on a periodic basis e.g. a userdefined period such as every 5 minutes. Many SCADA systems operate this way. The problems that result are very similar to the ones outlined in the first section. It is important to make sure that data capture at the SCADA is based on change and uses the original date/time stamp from the field. Page 7 of 8

The MultiTrode solution MultiTrode is a leading supplier of control and monitoring equipment to the water and wastewater industry. The MultiSmart pump station manager has a DNP3 RTU. (This is a fully compliant DNP3 level 2 RTU). The product is an out of the box pump station controller with an intuitive user interface for operator control and engineering changes. MultiSmart can integrate into any SCADA system, and it also has Modbus to integrate into any existing Modbus-based SCADA. Figure 10 MultiSmart Face Plate and I/O unit Page 8 of 8