For Models #6-5001, #6-7501, #10-7501 & #10-12K1



Similar documents
Generator Transfer Switch Model # HTS15-AUTO

Advantium 2 Plus Alarm

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Utility Distribution Systems

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

User Manual HomeGrid 3000 Solar Generator

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

GENERAL WIRING RULES FOR HOUSES

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Transfer Switch 30 Amps STS-30. Manual. Please read this manual before operating your transfer switch

INSTALLATION & SERVICE MANUAL. Display Panel

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Electrical Grounding. Appendix C

2 electrical. electrical PulteGroup, Inc. All Rights Reserved.

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Installation and Operation Guide for PD4000 Series Power Control Center

Single Station Remote Alarm

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

, User s Manual

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

24.2L M.A.N. V12 Engine Module

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

HOUSING QUALITY STANDARDS (HQS)

Ceiling Mount Air Handler Manual

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Arc Fault Circuit Interrupters Frequently Asked Questions

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

TRANSFORMER HD-HAMPTON HAMPTONBAY.COM

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

Touch Tone Controller. Model TR16A. Owner s Manual

INSTANT HOT WATER RECIRCULATING SYSTEM

ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v

INSTALLER S & OWNER S MANUAL

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

16/32 Channel 1U Rack Mount CCTV Power Supply

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Generator 101: Buying and Installing a Generator for Your Home or Office. bruniandcampisi.com

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

ChargePoint Home. Installation Guide. ATTENTION: Please read thoroughly and keep this installation guide.

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

Installation and Operation Guide for PD4100 Series Power Control Centers

PARTS & SERVICE MANUAL for CONTEMPO SERIES WARMER LAMPS

Installation and Operation Guide PD4600 Series Converter Replacement

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

How To Keep An Eye On Electric Safety

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

On/Off Relay Switch and 3-Way Switch Kit

LT Charging Cart for Laptops

100 Series Maxi Internal Filters. Instruction Manual

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

INSTALLATION INSTRUCTIONS

in the United States Home fires are a major problem Older Homes Pose an Even Greater Threat Put it into perspective: Electrocutions can be Prevented

E2 Series Electric Furnaces

Field Commander Wiring Manual

Installation and Operation Guide for PD5100 Automatic Transfer Switch

OWNERS MANUAL FOR CORDLESS INFLATOR AIR260

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

Refer installation of power supplies to qualified service personnel.

Safety, Operation and Maintenance Manual with Parts List

VX 2400 Dimmer User's Manual

The Different Types of AC Power Connectors in North America

Automatic AES Change-Over

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords?

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Anthro Tablet Charging Cabinets

Installation Instructions

12-Volt 10-Amp Regulated Power Supply

Installation Instructions WARNING: WARNING: WARNING: WARNING: WARNING:

INSTRUCTION MANUAL MODEL PCD-88

Tablet 30W Tablet 92W

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

RC930 Manual 6/10/99 1:23 PM Page 1. Wireless Modem Jack

MODEL # Introduction

Nest Learning Thermostat Installation Guide. Installation step-by-step

OPERATING INSTRUCTIONS FOR LED-4 MULTI-SPORT TABLETOP SCOREBOARD

ClearView 100. Instruction Manual

Global Water Instrumentation, Inc.

Die-Cast Metal, Motion- Activated Post Light

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Model SRMD Setra Remote Monitoring Display

HM-W536 Install Guide

Transcription:

EmerGen Switch Manual Transfer Switch Manufactured by CONNECTICUT ELECTRIC SWITCH MFG. CO. 1-800-730-2557 OWNER S MANUAL & INSTALLATION INSTRUCTIONS For Models #6-5001, #6-7501, #10-7501 & #10-12K1 PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE INSTALLING AND/OR OPERATING YOUR EMERGEN SWITCH. RETAIN THIS MANUAL FOR FUTURE REFERENCE. Congratulations on the purchase of your new EmerGen Switch! Your new EmerGen Switch will provide you with a way to safely utilize generator power through your existing electrical wiring during a power outage. You will install your switch next to your home s electrical panel and then you will connect circuit breaker wires to the circuits within the transfer switch. Once you power up your portable generator, you will manually turn on each switch and that generator energy is transferred as electrical power and goes through the house circuits you have previously chosen. Your EmerGen Switch is easy for a licensed electrician or qualified professional to install, safe for a homeowner to operate, and will work with 120/240 Volt AC single phase generators, factory equipped with a NEMA (National Electrical Manufacturer s Association) type receptacle; L14-20R, L14-30R or Calif. Style 50 Amp Twist Lock, depending on the size EmerGen Switch you have chosen. Your EmerGen Switch will not permit connection to both utility and generator power at the same time.

Mini-breakers protect your circuits while in the generator mode. Four 1 pole and one 2 pole circuits yield enough hot circuits to keep your home and family safe and comfortable. Side Installation Bars allow an easy surface mount installation. Powder Coated Finish will not rust. Locking Power Inlet accepts NEMA (L1420) configurated cord caps. Double Throw Switch eliminates power backfeeding to the utility pole when power is restored. Also eliminates utility power from entering the generator. Tie Bar allows a 240V circuit on switches C & D - perfect for well pumps. Generator-operated Convenience Outlet provides an accessible plug-in nearby for tools or emergency lighting. Maximum Watts (Including Surges) Number of Circuits Maximum Combined Loads at 250VAC Max. Load Per Circuit from Generator Max. Load Per Circuit from Load Center #6-5001 EmerGen Switch 5000 Watts 4 Single Poles 1 Double Pole 20 Amps 15 Amps 20 Amps Built-In Wattage Meters permit load balancing to avoid impeding the generator s performance and visually provides the amount of wattage being used. #6-7501 EmerGen Switch 7500 Watts 4 Single Poles 1 Double Pole 30 Amps 15 Amps 20 Amps Maximum Watts (Including Surges) Number of Circuits Maximum Combined Loads at 250VAC Max. Load Per Circuit from Generator Max. Load Per Circuit from Load Center Pre-Wired for the Do-It-Yourselfer or Electrical Contractor to simplify and speed up actual installation. #10-7501 EmerGen Switch 7500 Watts Six Single Poles Two Double Poles 30 Amps 15 Amps-A,B,C,F,G,H 20 Amps - D, I, E, J 20 Amps-A,B,C,F,G,H 20 Amps - D, I, E, J #10-12K1 EmerGen Switch 12,500 Watts Six Single Poles Two Double Poles 50 Amps 15 Amps-A,B,C,F,G,H 20 Amps - D, I, E, J 20 Amps-A,B,C,F,G,H 20 Amps - D, I, E, J Mini-breakers protect your circuits while in the generator mode. Six Single Poles and Two Double Poles yield enough hot circuits to keep your home and family safe and comfortable. Tie Bars allow two 20 Amp double pole circuits. Locking Power Inlet accepts NEMA configurated cord caps. Side Installation Bars allow an easy surface mount installation Double Throw Switch eliminates power backfeeding to the utility pole when power is restored. Also eliminates utility power from entering the generator. Powder Coated Finish will not rust. Built-In Wattage Meters permit load balancing to avoid impeding the generator s performance and visually provides the amount of wattage being used. Generator-operated Convenience Outlet provides an accessible plug-in nearby for tools or emergency lighting. Pre-Wired for the Do-It-Yourselfer or Electrical Contractor to simplify and speed up actual installation. - 2 -

SAFETY INFORMATION 1. The National Electrical Code states the connection of a generator to any electrical circuit normally powered by an electrical utility, must be by means of an approved transfer switch so as to isolate the electrical circuit from the utility system when the generator is operating. Your EmerGen Switch is approved by UL which accomplishes the isolation this code is requiring. 2. Your EmerGen Switch is for indoor use only. 3. A licensed electrician or qualified professional must install this EmerGen Switch according to local code. Some areas require the use of a junction box. Note that additional items will be needed for installation if a junction box is used (conduit, fittings, wire nuts, etc.). 4. To reduce the risk of electrical shock, the MAIN circuit breaker in the load center must be OFF, during the course of installation. After installation, it stays on - even during power outages. GENERATOR 1. The portable generator used with your EmerGen Switch must be operated outside of any building. 2. Always plug the power cord set into your generator and into the EmerGen Switch before starting your generator and always shut the generator down before detaching the power cord set. 3. Do not overload your generator circuit breaker or it will trip. Using the EmerGen Switch s built-in wattage meters, you can balance the loads to avoid impeding your generator s performance. INSTALLATION PREPARATION 1. Decide which circuits will be powered by the generator during a power outage. The recommended circuits include the fireplace fan or furnace fan (gas or oil only), sump pump, refrigerator, freezer, one lighting or kitchen appliance circuit and perhaps one lighting circuit elsewhere. Most well pumps are 240 volt - or any other 240 volt appliance - will utilize two EmerGen Switch circuits (C & D on the 6-circuit models and D & I or E & J on the 10-circuit models). 2. Plan ahead: Identify the load center circuits you ve determined are less than 15 amps. Designate each EmerGen Switch circuit that will be used. The plan should also identify circuits that exceed 15 amps so that the two circuits to be used can be designated. WARNING: If a circuit you have selected is a GFCI circuit breaker, it will NOT be a GFCI circuit while it is powered by the generator. - 3 -

WATTAGE REQUIREMENTS 1. Most appliances and motors have current ratings noted directly on the units. Light bulb wattages are noted on the bulbs. 2. Some electric motors surge in power when first started. Your EmerGen Switch has watt meters so that you can monitor the flow of these start up surges without impeding your generator s performance. 3. Load balance is obtained by the pre-determination of chosen circuits. On the 6-circuit models, for instance, use circuit A for your refrigerator and circuit E for your freezer. Since both appliances have induction type motors, they can be easily balanced on separate phases of the EmerGen Switch. USE THIS GUIDELINE TO DETERMINE YOUR WATTAGE REQUIREMENTS APPLIANCE WATTS 1/2 HP PUMP MOTOR 600 1/4 HP PUMP MOTOR 400 COFFEE MAKER 1000 FIREPLACE FAN 300 FREEZER 500 FURNACE FAN 700 GARAGE DOOR OPENER 600 LIGHT CIRCUIT 300 LIGHT CIRCUIT 300 MICROWAVE OVEN 800 REFRIGERATOR 900 TV SET 350 WATER HEATER 3500 TOTAL WATTS: TYPICAL INSTALLATION ALWAYS CHECK LOCAL CODES BEFORE INSTALLATION! - 4 -

INSTALLATION INSTRUCTIONS WARNING: Installer must be knowledgeable with residential wiring methods and subsequent electrical local codes. Neither the manufacturer nor distributor accepts responsibility for accidents caused by misuse or incorrect installation. 1. Determine where you want your EmerGen Switch located, either to the left or the right of your load center. The switch should be no more than 18 from the center of your load center, making sure there is plenty of room to properly connect the flex conduit whip. 2. TURN OFF POWER. Main circuit breaker should be switched to the OFF position. This does not affect the wires on the line side of the main breaker - they will remain live! Remove the cover of the load center. 3. Identify an appropriate knockout to remove: 3/4 for the 6-circuit models and 1 for the 10-circuit models. - 5 -

Installation Instructions (cont d) 4. Insert the wires from the flex conduit up through the knockout; take care to not nick or gouge the wires on the metal edge. Tighten the locknut securely onto the load center. The wires can hang freely. 5. Without over-manipulating the flex conduit, secure your EmerGen Switch to the wall with fasteners appropriate to the wall s construction. 6. From your plan, locate the circuit breaker that is to be connected to EmerGen Switch circuit A. Turn that circuit breaker to its OFF position. Loosen the lug securing the wire and remove the wire. (If the circuit you have chosen is a GFCI circuit breaker, it will not be a GFCI circuit while it is powered by the generator.) 7. Find both the red and the black EmerGen Switch wires labeled A. Using good workmanship, route both of these wires close to the selected circuit breaker. a. The red EmerGen Switch A wire is trimmed, stripped and installed into the circuit breaker, securely tightening the breaker lug. b. The black EmerGen Switch A wire and the hot wire from the circuit breaker are placed up the side of load center together. c. After removing 5/8 of the wire insulation, insert both wires into a yellow wire nut and set them up neatly into the corner of the load center. Always cut and strip wires appropriately. Note: A 6-circuit, 125 amp panel was used for illustration purposes only. - 6 -

Installation Instructions (cont d) 8. From your plan, select the B circuit breaker and corresponding EmerGen Switch B wires (keeping in mind that if the circuit is a GFCI circuit breaker, it will not be a GFCI circuit while it is powered by the generator). Turn that breaker to the OFF position and remove its wire by unscrewing the lug. a. The red EmerGen Switch B wire is trimmed, stripped and installed into the circuit breaker, securely tightening the breaker lug. b. The black EmerGen Switch B wire and the hot wire from the circuit breaker are placed up the side of load center together. c. After removing 5/8 of the wire insulation, insert both wires into a yellow wire nut and set them up neatly into the corner of the load center. Always cut and strip wires appropriately. Note: A 6-circuit, 125 amp panel was used for illustration purposes only. - 7 -

Installation Instructions (cont d) 9. These steps are continued for each desired circuit (keeping in mind that if the circuit is a GFCI circuit breaker, it will not be a GFCI circuit while it is powered by the generator). In the event that a 240 volt (2 pole) circuit will be used, the same concept is used. a. The red EmerGen Switch C wire is trimmed, stripped and securely installed into one side of the two pole circuit breaker. b. The black EmerGen Switch C wire and the hot wire from the circuit breaker are placed up the side of load center together. Insert both wires into a yellow wire nut and set them up neatly into the corner of the load center. c. The red EmerGen Switch D wire is trimmed, stripped and securely installed into the other side of the two pole circuit breaker. d. The black EmerGen Switch D wire and the hot wire from the circuit breaker are placed up the side of load center together. Insert both wires into a yellow wire nut and set them up neatly into the corner of the load center. Note: A 6-circuit, 125 amp panel was used for illustration purposes only. - 8 -

Installation Instructions (cont d) If two single poles are desired, rather than a double pole, simply remove the tie bar and wire the single circuits as in steps 7-8. Note: On 6-circuit models, the double pole circuit is on C and D and On 10-circuit models, the double pole circuits are D & I and E & J. 10. When the above steps have been completed for all desired circuits, the WHITE (neutral) wire needs to be installed. a. Select any unused hole in the neutral bar of the load center. b. Cut and strip the wire appropriately, insert the wire into the hole and tighten securely. Always cut and strip wires appropriately. 11. The GREEN (ground) wire needs to be installed into an unused hole in the ground bar in the load center. a. Select any unused hole in the ground bar of the load center. b. Cut and strip the wire appropriately, insert the wire into the hole and tighten securely. 12. Replace the load center cover. All circuit breakers can now be turned on, including the main breaker. 13. All EmerGen Switches should be in the LINE position. The OFF position is generally not used. 14. Fill out the chart supplied with your EmerGen Switch describing each emergency circuit and corresponding circuit breaker. Place this sticker on or near your EmerGen Switch for easy reference. - 9 -

OPERATION/TEST PROCEDURE 1. Switch positions should remain in the LINE position under normal utility power. OFF is generally not used. GEN positions are used when connecting circuits to your generator power source. 2. When testing and/or switching to generator power after a power outage, ensure all switches are in the LINE position. (There is no need to turn off any load center circuit breakers.) 3. Plug your power cord set into your generator by aligning the male prongs with the female terminals of your generator s receptacle, push the connector in and twist clockwise to lock (Some connectors do not twist). Align the female socket of the cord set into your EmerGen Switch, push it in and turn clockwise to lock. 4. Move your generator outdoors before starting it up. Check to see fluids and fuel are adequate and start your generator following its instruction manual. 5. At your EmerGen Switch, move one circuit to the GEN position, making a note of how much wattage is used on the meter. While monitoring the load, flip each circuit- one at a time - to the GEN position. You do not need to go in order and you want to balance the loads so that both meters read approximately the same. Do not switch on more loads than your generator can supply. Note: Wattage must not exceed the maximum rating printed on the meters. 6. During a power outage and after your generator is powered up, you may first want to plug in a lamp or worklight to the receptacle on the front of your EmerGen Switch. This plug-in is internally wired to switch F on all models. LOAD MANAGEMENT 1. All circuits can be used simultaneously only if your generator has sufficient wattage capacity. If an electrical load is exceeded by its capacity, the mini-breaker may trip. To reset: a. Eliminate the overload condition. b. Move the switch with the tripped breaker to the OFF position. c. Re-set the breaker by pressing it in; make sure it stays in. d. Move the switch back to the GEN position. It should now operate properly. If it does not, you may need to contact an electrician or qualified professional. - 10 -

PRODUCT WARRANTY Every is guaranteed against mechanical or electrical failure due to manufacturing defects for a period of one year following shipment from factory. Connecticut Electric warrants to the Purchaser that this product will be free from defects in material or workmanship and will be of the kind and quality designated. This warranty shall apply only to defects appearing within one year from the date of shipment by Connecticut Electric. The liability of Connecticut Electric under this warranty, or for any loss or damage to the equipment shall not in any case exceed the cost of correcting defects in the equipment and upon the expiration of the warranty period, all such liability shall terminate. Connecticut Electric warrants that at the time of shipment the products manufactured and sold shall be in conformity with applicable written specifications, free from defects in material and workmanship, merchantable, and suitable for a particular purpose, provided such is implied by state law under the circumstances of this sale. Connecticut Electric agrees to repair or furnish a replacement for, but not remove or install, any product or component thereof which, within one year from the date of shipment by Connecticut Electric shall, upon test and examination by Connecticut Electric, prove to be defective within the above warranty. Buyer shall notify Connecticut Electric of any defect within this warranty no later than thirty (30) days after a defect is discovered. No product shall be accepted for return or replacement without authorization from Connecticut Electric. This warranty is limited solely to the above and applies only for the period set forth. Connecticut Electric will not be liable for any loss, damage, incidental or consequential damages of any kind, whether based upon warranty contact, or negligence, and/or arising in connection with the sale, use, installation or repair of this product. Connecticut Electric s maximum liability shall not, in any case, exceed the contract price for the products claimed to be defective or unsuitable. This warranty does not extend to any product manufactured by Connecticut Electric, which has been subjected to misuse, neglect, accident, improper installation or use in violation of instructions furnished. This warranty does not extend to or apply to any unit which has been repaired or altered, either to the product or to the components manufactured by any other supplier other than Connecticut Electric. - 11 -

TROUBLE SHOOTING Problem Generator is running, but no AC output is available. Cause 1. Generator circuit breaker has tripped. 2. Poor connection or defective cord set. 3. Connected device is bad. 4. Fault in generator. Solution 1. Reset circuit breaker. 2. Check and repair. 3. Select a different load or appliance that is in good condition. 4. Contact a qualified professional. Generator runs but bogs down when loads are connected. 1. Short circuit in a connected load. 2. Generator is overloaded. 1. Disconnect shorted electrical load. 2. Review monitoring the loads to rearrange. Switches are not working with generator power. 1. Switches are in OFF or LINE position. 2. Generator circuit breaker has tripped. 3. Poor connection or defective cord set. 4. Connected device is bad. 5. Fault in generator. 1. Move switches to GEN. 2. Reset circuit breaker. 3. Check and repair. 4. Select a different load or appliance that is in good condition. 5. Contact a qualified professional. Circuits do not operate after utility power is restored. 1. Switch is in GEN or OFF position. 2. Load center circuit breaker tripped. 1. Set switch to LINE position. 2. Reset circuit breaker in load center. Only some loads work on generator power. 1. EGS mini-breaker tripped. 1. Reset EGS mini-breaker. - 12 - Connecticut Electric & Switch Mfg.Co. COPYRIGHT 2001