Continuous Availability for Business-Critical Data



Similar documents
Continuous Availability for Business-Critical Data. MetroCluster Technical Overview

ENABLING RHEV WITH NETAPP STORAGE. Jon Benedict Systems Architect, NetApp Geert Jansen RHEV Product Marketing Manager, Red Hat May 6, 2011

Uncompromised business agility with Oracle, NetApp and VMware

How To Write A Server On A Flash Memory On A Perforce Server

High Availability and MetroCluster Configuration Guide For 7-Mode

NetApp FAS3200 Series

Datasheet NetApp FAS3200 Series

Datasheet The New NetApp FAS3200 Series Enables Flash, Clustering to Improve IT Agility and Performance

A Continuous-Availability Solution for VMware vsphere and NetApp

EMC VPLEX FAMILY. Continuous Availability and Data Mobility Within and Across Data Centers

EMC VPLEX FAMILY. Continuous Availability and data Mobility Within and Across Data Centers

Clustered Data ONTAP 8.3 Administration and Data Protection Training

Datasheet NetApp FAS6200 Series

SnapMirror Async Overview and Best Practices Guide

NetApp SnapMirror. Protect Your Business at a 60% lower TCO. Title. Name

Datasheet NetApp FAS8000 Series

NetApp Replication-based Backup

FlexArray Virtualization

Pricing - overview of available configurations

Extended Distance SAN with MC/ServiceGuard Opens New Disaster Recovery Opportunities

The safer, easier way to help you pass any IT exams. Exam : Storage Sales V2. Title : Version : Demo 1 / 5

NetApp Storage. Krzysztof Celmer NetApp Poland. Virtualized Dynamic Infrastructure. Applications. Virtualized Storage. Servers

HIGH AVAILABILITY AND DISASTER RECOVERY FOR VMWARE USING NETAPP SNAPMIRROR AND METROCLUSTER

EMC VPLEX FAMILY. Transparent information mobility within, across, and between data centers ESSENTIALS A STORAGE PLATFORM FOR THE PRIVATE CLOUD

EXTENDED ORACLE RAC with EMC VPLEX Metro

Virtualize Without Compromise. Protecting and Storing Virtualized Data

How To Use Vcenter Site Recovery Manager 5 With Netapp Fas/Vfs Storage System On A Vcenter Vcenter 5 Vcenter 4.5 Vcenter (Vmware Vcenter) Vcenter 2.

NetApp Unified Storage

Violin Memory Arrays With IBM System Storage SAN Volume Control

Data Protection Online Backup and Recovery Guide For 7-Mode

EMC Business Continuity for Microsoft SQL Server 2008

Server and Storage Virtualization with IP Storage. David Dale, NetApp

Deploying NetApp Storage Solutions in a Database Environment

NetApp FAS2000 Series

Software Storage Platform Mixing Rules

Integrated Application and Data Protection. NEC ExpressCluster White Paper

Data ONTAP Mode Data Protection Online Backup and Recovery Guide

NetApp FAS/V-Series. NetApp BDM

Veritas InfoScale Availability

IP Storage On-The-Road Seminar Series

Quorum DR Report. Top 4 Types of Disasters: 55% Hardware Failure 22% Human Error 18% Software Failure 5% Natural Disasters

Windows Server 2012 授 權 說 明

EMC CLARiiON Guidelines for VMware Site Recovery Manager with EMC MirrorView and Microsoft Exchange

Introduction to NetApp Infinite Volume

Virtualizing Microsoft Exchange Server 2010 with NetApp and VMware

Cisco Active Network Abstraction Gateway High Availability Solution

Entry level solutions: - FAS 22x0 series - Ontap Edge. Christophe Danjou Technical Partner Manager

FLASH STORAGE SOLUTION

Formation NetApp Accelerated NCDA

Simplified HA/DR Using Storage Solutions

NetApp SnapManager for Microsoft Exchange

Oracle Database Disaster Recovery Using Dell Storage Replication Solutions

Enhancements of ETERNUS DX / SF

HP ProLiant Storage Server family. Radically simple storage

Software Defined Storage Needs a Platform. Piotr Biskupski. Storage Solutions Technical Leader - IBM Flash System, IBM CEE

DPAD Introduction. EMC Data Protection and Availability Division. Copyright 2011 EMC Corporation. All rights reserved.

New Cluster-Ready FAS3200 Models

STORAGE CENTER. The Industry s Only SAN with Automated Tiered Storage STORAGE CENTER

I/O Considerations in Big Data Analytics

7-Mode SnapMirror Async Overview and Best Practices Guide

Best in Class Storage Solutions for BS2000/OSD

10th TF-Storage Meeting

Veritas Cluster Server by Symantec

Redefining Oracle Database Management

Microsoft SharePoint 2010 on VMware Availability and Recovery Options. Microsoft SharePoint 2010 on VMware Availability and Recovery Options

Microsoft Cross-Site Disaster Recovery Solutions

SOFTWAREDEFINED-STORAGE

Clustered Data ONTAP 8.3

IBM System Storage Executive Briefing Center Topics (Tucson)

Clustered Data ONTAP 8.3

The last 18 months. AutoScale. IaaS. BizTalk Services Hyper-V Disaster Recovery Support. Multi-Factor Auth. Hyper-V Recovery.

Symantec Cluster Server powered by Veritas

CommVault Backup Appliance with NetApp

Veritas Cluster Server from Symantec

The future of Storage and Storage Management Using Virtualization to Increase Productivity. Storyflex VISION 2007 Hans Lamprecht NetApp SEE Vienna

BlueArc unified network storage systems 7th TF-Storage Meeting. Scale Bigger, Store Smarter, Accelerate Everything

EMC RecoverPoint Continuous Data Protection and Replication Solution

June Blade.org 2009 ALL RIGHTS RESERVED

Re-Invent Your Recovery

EMC Symmetrix V-Max and Microsoft SQL Server

ORACLE DATABASE HIGH AVAILABILITY STRATEGY, ARCHITECTURE AND SOLUTIONS

What Is Microsoft Private Cloud Fast Track?

(Scale Out NAS System)

Oracle Maximum Availability Architecture with Exadata Database Machine. Morana Kobal Butković Principal Sales Consultant Oracle Hrvatska

RFP-MM Enterprise Storage Addendum 1

29/07/2010. Copyright 2010 Hewlett-Packard Development Company, L.P.

Reducing the cost of Protecting and. Securing Data. Assets. Big data, small data, critical data, more data. NetApp

ETERNUS CS High End Unified Data Protection

DISASTER RECOVERY STRATEGIES FOR ORACLE ON EMC STORAGE CUSTOMERS Oracle Data Guard and EMC RecoverPoint Comparison

HIGHLY AVAILABLE MULTI-DATA CENTER WINDOWS SERVER SOLUTIONS USING EMC VPLEX METRO AND SANBOLIC MELIO 2010

Transcription:

Continuous Availability for Business-Critical Data MetroCluster Technical Overview Jean-Philippe Schwartz Storage Systems Specialist - IBM / Gate Informatic jesc@ch.ibm.com

Agenda NetApp / IBM Agreement Customer Challenges NetApp Business Continuity Solutions NetApp MetroCluster Overview MetroCluster Failure Scenarios When do I need MetroCluster IBM MetroCluster in SR One Pager 2

NetApp / IBM Agreement 3

Why NetApp? Mainframe, System i Open Systems Heterogeneous NAS High-end Mid-range DS8000 For clients requiring: One solution for mainframe & open systems platforms Disaster Recovery across 3 sites across 2 sites > 100 km apart Secure encryption Continuous availability, no downtime for upgrades Best-in-class response time Dedicated rack DS4000/5000 For customers requiring: Open systems environment support including IBM i support Cost efficient storage for capacity Modular storage XIV For clients requiring: Open systems environment support Future-proof capacity expansion and management Web 2.0 workloads Dedicated Rack SVC For clients requiring: Virtualization of multiple vendor environments, including IBM, EMC, HP and others V7000 For clients requiring storage virtualization, Thin provisioning, EasyTier, online migration SoNAS For customers with massive IO / backup / restores N series For clients with: Combined NAS (file) and SAN requirements Simple two-site high availability Entry DS3000 For very price-sensitive customers Modular storage Affordable disk shelves behind SVC EE Supercomputing DCS9900 (HPC and Digital Media clients only) 4

IBM and Network Appliance Join Forces Previous attempts by IBM to penetrate the NAS market in 2001-2004 have shown limited success (NAS100, NAS200, NAS300, NAS300G then later on NAS500G) In April, 2005, IBM and Network Appliance announced a strategic storage relationship to drive information on demand solutions and to expand IBM's portfolio of storage solutions: -IBM sells re-branded Network Appliance storage solutions as N series -Network Appliance extends its market presence with key partner IBM does additional testing on specific solutions to ensure the highest possible Availability, Reliability & Scalability 5

IBM N series Offer For Customer NAS only or Unified Storage Requirements Same HW and DOT as NetApp Platforms Full range of NetApp Software Functions Filer and Gateway Models Entry level pricing, Enterprise Class Performance N3000 Series Excellent performance, flexibility and scalability at a lower TCO N6000/Gateway Series Highly-scalable storage systems for large enterprise data centers. N7000/Gateway Series Up to 1176TB Up to 1.2PB Up to 136TB 6

Customer Challenges 7

Customer Challenges Internal Data Center Failures External Data Center Failures NetApp FAS HA (active-active) MetroCluster Addresses the storage major hardware causes of downtime failures in in the the data data center Source: Forester / Disaster Recovery Journal: Global Disaster Recovery Preparedness Online Survey, Oct, 2007 8

NetApp Business Continuity Solutions 9

Availability IBM System Storage N series Unified Storage Solutions NetApp Data Protection and Business Continuity Solutions Block-Level Incremental Backups Asynchronous Replication Synchronous Replication LAN/WAN Clustering Continuous Operations Synchronous Clusters MetroCluster Synchronous SnapMirror and Clusters Data Protection Synchronous SnapMirror and SyncMirror Asynchronous SnapMirror Application Recovery SnapRestore SnapVault Cost Daily Backup Snapshot Copies Local Restore Remote Restore Remote Recovery Low RTO Capability 10

The MetroCluster Difference Across Floors, Building, or Campus Within Data Center Across City or Metro Area NetApp MetroCluster provides continuous availability within a single data center and across data centers in adjacent floors, buildings, and metro areas Support for N series N6000 & N7000 MetroCluster MetroCluster Stretch Stretch up to 500 up mto 100 km 11

The MetroCluster Difference: Automatic Protection Primary Data Center Alternate Data Center Others Oracle Exchange Oracle Exchange SharePoint SharePoint Home Dirs Create volume New Volume Home Dirs New Volume MetroCluster Oracle Exchange Home Dirs SharePoint New Volume Set up replication Aggregate Mirroring Create destination volume Oracle Exchange Home Dirs SharePoint New Volume Create volume Automatic mirroring 12

The MetroCluster Difference: Quick Recovery Time Others Primary Data Center Exchange Oracle SharePoint Home Dirs New Volume Alternate Data Center 1. Break Mirror 2. Bring Online ONLINE 3. Break Mirror ONLINE Exchange 4. Bring Online Oracle 5. Break Mirror ONLINE 6. Bring Online ONLINE SharePoint 7. Break Mirror Home Dirs 8. Bring Online ONLINE 9. Break Mirror New Volume 10. Bring Online MetroCluster Oracle Exchange Home Dirs SharePoint New Volume CF Forcetakeover -d ONLINE ONLINE Oracle Home Dirs ONLINE ONLINE SharePoint Exchange New Volume ONLINE 13

NetApp Efficiency Deduplication offers cost savings for MetroCluster Deduplication efficiencies for both the source and mirrored arrays Investment protection and storage efficiency for other vendors storage with V-Series systems PVR no longer required Must be licensed on both nodes Must be running NetApp Data ONTAP 7.2.5.1 or later, 7.3.1 or later Subject to the same considerations as non MetroCluster systems 14

MetroCluster Overview 15

MetroCluster Components Cluster License SyncMirror Cluster Remote FC Interconnect Provides automatic failover capability between sites in case of most hardware failures. Provides an up-to-date copy of data at the remote site; data is ready for access after failover without administrator intervention. Provides a mechanism for the administrator to declare a site disaster and initiate a site failover with a single command. Provides appliance connectivity between sites that are more than 500 meters apart; enables controllers to be located a safe distance away from each other. 16

MetroCluster Deployment in a Single Data Center, Across Floors, and So On Node 1 Node 2 Stretch MetroCluster 500m Aggregate X Aggregate Y Aggregate Y Mirror Data Center Aggregate X Mirror 17

MetroCluster Deployment Across City or Metro Areas Building A Fabric MetroCluster Building B <=100 km DWDM Dark Fiber DWDM Aggregate X Aggregate Y Mirror No SPOFs redundancy in all components and connectivity Dedicated pairs of FC switches Aggregate Y Aggregate X Mirror 18

MetroCluster Component: Cluster Remote License Provides single-command failover. Provides the ability to have one node take over its partner s identity without a quorum of disks. Root volumes of both appliances MUST be synchronously mirrored. By default, all volumes are synchronously mirrored and are available during a site disaster. Requires administrator intervention as a safety precaution against a split brain scenario (cf forcetakeover d) 19

MetroCluster Component: SyncMirror Writing to an unmirrored volume Writing to a mirrored volume Two Plexes Created Plex 0 from Pool 0 = Orig Plex 1 from Pool 1 = Mirror Note: Plex # may change over time Volume1 Volume1 A Plex 0 Pool 0 A Plex 0 Pool 0 A Plex 1 Pool 1 20

MetroCluster Support Matrix Stretch Fabric FAS/V Model Supported Max. Disks Supported Max. Disks 3070 Yes 504 Yes 504 1 3140 Yes 420 Yes 420 3170 Yes 840 Yes 840 2,3 3210 Yes 480 Yes 480 3240 Yes 600 Yes 600 3270 Yes 960 Yes 840 2 6030 Yes 840 Yes 840 2,3 6040 Yes 840 Yes 840 2,3 6070 Yes 1008 Yes 840 2,3 6080 Yes 1166 Yes 840 2,3 6210 Yes 1008 Yes 840 2,4 6240 Yes 1176 Yes 840 2,4 6280 Yes 1176 Yes 840 2,4 1 504 spindle count requires Data ONTAP 7.2.4 or later 2 672 spindle count requires Data ONTAP 7.3.2 to 7.3.4 3 840 spindle count requires Data ONTAP 7.3.5 or later 4 840 spindle count requires Data ONTAP 8.0.1 or later 21

Twin MetroCluster Configuration (DOT 7.3.3) 22

New in Data ONTAP 7.3.5/8.0.1 FAS 32xx FAS32xx series support FAS62xx series Support Up to 840 spindles on fabric MetroCluster 8Gb cluster interconnect 8Gb FCVI X1927A-R6 23

MetroCluster Failure Scenarios 24

Host Failure Host 1 Data Center #1 Data Center #2 Host 2 Recovery Automatic Host #2 accesses its data across the data centers FAS 1 FAS 2 DC1 Primary DC2 Mirror DC 1 Primary DC2 Primary DC1 Mirror 25

Storage Controller Failure Host 1 Data Center #1 Data Center #2 Host 2 Recovery Automatic FAS 2 provides data services for both data centers. Writes go to both plexes. Reads come from local by default. FAS 1 FAS 2 DC1 Primary DC2 Mirror DC 1 Primary DC2 Primary DC1 Mirror 26

Storage Array Failure Host 1 Data Center #1 Data Center #2 Host 2 Recovery Singlecommand failover FAS 1 FAS 2 DC1 Primary DC2 Mirror DC 1 Primary DC2 Primary DC1 Mirror 27

Complete Site Failure Host 1 Data Center #1 Data Center #2 Host 2 Recovery Singlecommand failover FAS 1 FAS 2 DC1 Primary DC2 Mirror DC 1 Primary DC2 Primary DC1 Mirror 28

Interconnect Failure Host 1 Data Center #1 Data Center #2 Host 2 Recovery No failover; mirroring disabled FAS 1 FAS 2 Both appliance heads continue to run, serving their LUNs/volumes Resyncing happens automatically after interconnect is reestablished DC1 Primary DC2 Mirror DC 1 Primary DC2 Primary DC1 Mirror 29

Return to Normal Host 1 Data Center #1 Data Center #2 Host 2 One-step return to normal CF giveback Mirror is rebuilt DC1 primary reverts back to FAS 1 DC1 FAS 2 DC1 Primary DC2 Mirror DC 1 Primary DC2 Primary DC1 Primary Mirror 30

When do I need MetroCluster 31

MetroCluster Positioning Qualification questions: Is continuous data availability important to one or more of your product applications? Would providing geographic protection be of value? What distance between controllers would provide the best protection (building, floor campus, metro, or regional)? If you are employing an HA solution for a virtualized environment, why not have the same resilience at the storage level? 32

SnapMirror Sync Versus MetroCluster Feature SnapMirror Sync MetroCluster Replication network IP or FC FC only Limit on concurrent transfers Yes No limit Distance limitation Up to 200km (latency driven) Replication between HA pairs Yes No Manageability Multi-use replica Deduplication Use of secondary node for async mirroring FilerView, CLI, Operations Manager Yes (FlexClone ) No (dump) Deduplicated volume and sync volume cannot be in the same aggregate Yes 100km CLI Limited (app can read from both plexes) No restrictions No. Async replication has to occur from primary plex 33

MetroCluster Best Practices Choose the right controller Based on normal sizing tools and methods Connections are important Calculate distances properly Use the right fiber for the job Verify correct SFPs, cables required, and patch panels Remember that mirroring requires 2x disks Remember MetroCluster spindle maximums 34

IBM MetroCluster in SR 35

IBM MetroCluster Installations in Suisse Romande Total of 5 IBM MetroCluster Customers in Suisse Romande 3 Stretch Configurations 1 x Across Rooms 1 x Across Floors 1 x Across Roads 2 Fabric Configurations 1 x Owned LW Connections (1.2 km) 1 x External Provider Service (30+ / 50+ km) Extremely High Customer Satisfaction 36

One Pager 37

Value of MetroCluster Simple Set it once: Easy to deploy, with no scripts or dependencies on the application or operating system Zero change management through automatic mirroring of changes to user, configuration, and application data Continuous availability Zero unplanned downtime through transparent failover with protection for hardware plus network and environmental faults Zero planned downtime through nondisruptive upgrades for storage hardware and software. Cost effective 50% lower cost, no host-based clustering required, added efficiency through data deduplication and server virtualization Data Center MetroCluster 38

Thank You 39