General. Industry. Siemens AG, I IA CD, P.O. box 48 48, D-90026 Nuremberg. Postal address: Siemens AG I IA CD P.O. box 48 48 D-90026 Nuremberg



Similar documents
How to design safe machine control systems a guideline to EN ISO

Siemens Security Bulletin Response to ICS Alert (ICSA A)

FUNCTIONAL SAFETY CERTIFICATE

Machineontwerp volgens IEC 62061

PABIAC Safety-related Control Systems Workshop

Safe Torque Off Option (Series B) for PowerFlex 40P and PowerFlex 70 Enhanced Control AC Drives

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

STAR Linear Bushings and Shafts Supplement RE / Linear Motion and Assembly Technologies

Standards which are relevant to the selection and use of electrical switches for safety related controls in mine shaft and winding systems HSL/2007/58

Dr. Karsten Ehms Global Technology Field Knowledge Management. Copyright Siemens AG Alle Rechte vorbehalten.

Safety and functional safety A general guide

The SISTEMA Cookbook 4

UNIT 1 INTRODUCTION TO NC MACHINE TOOLS

Understanding Safety Integrity Levels (SIL) and its Effects for Field Instruments

SAFETY MANUAL SIL Switch Amplifier

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

SITEMA PowerStroke. Technical Information TI-P12. 1 Function. 2 Applications. Mould Closing Devices series FSKP. Contents

SHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM

Machine Safety Switch: SI-LM40 Series Limit Switch Style

GAM900/GAM900S. Acceleration precisely measured and safely monitored

Application Technique. Safety Function: Magnetic Door Switch Monitoring

Safety along the complete line: SIRIUS 3SE7 cable-operated switches. sirius COMMANDING & SIGNALING

Overview of IEC Design of electrical / electronic / programmable electronic safety-related systems

Wynn s Extended Care

Hardware safety integrity Guideline

Machine Safety Switches

WE-350 Series ¼ Turn Electric Actuator

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

Working Drawing and Assemblies. Chapter 10

Operating Instructions Drill rig DRU160

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Hydraulic control unit series

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Competence gives security. A competitive edge in rotary axes through experience, simulation, calculation, testing

Mounting Instructions. Torque Transducer. A en

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

Document Title Press Maintenance Checklist used in performing routine maintenance on punch presses

Basic Fundamentals Of Safety Instrumented Systems

Series 6000 Torque measured metal bellow coupling

Load Limiter ULS-60 ULS-80 ULS-100 ULS-125. Table of Contents. Assembly Instructions Load Limiter ULS-60, -80, -100, -125

Linear guide slides. For smooth and extremely accurate positioning

HYDRAULIC LIFT TABLE CART 2200-LB.

UNIT II Robots Drive Systems and End Effectors Part-A Questions

SAFETY MANUAL SIL SMART Transmitter Power Supply

Value Paper Author: Edgar C. Ramirez. Diverse redundancy used in SIS technology to achieve higher safety integrity

EC DECLARATION OF CONFORMITY FOR MACHINES

Table of Contents WARNING SYMBOLS AND DEFINITIONS

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

CONFIGURABLE SAFETY RELAYS

Machinery Safety. Presented by Paul Laidler. TÜV SÜD Product Service

Operation of the overrun braking system.

Profile rail guides LLR

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Introduction to Safety

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

The hydraulically damped overrun control device is made up of six main elements that control and operate the braking system.

Service Manual SSCI. The Care and Maintenance of Casters. Wheeling, IL (800) Form No /06

1. Lay out 2 pieces of 7/8" tubing and mark for bending as shown. Remember that the bend is in the shaded area as shown below in Figure 1.

Safety at injection moulding machines

Fish Grader User Manual

SAFETY MANUAL SIL RELAY MODULE

1000-LB. TRAILER JACK OWNER S MANUAL

Technical Data. Dimensions

Joint Report. of the Managing Board of Siemens Aktiengesellschaft, Berlin and Munich, and of the Management of Kyros 47 GmbH, Munich,

BLR s Safety Training Presentations

Installation instruction

Tool And Material Checklist

HOLLISTER-WHITNEY ROPE GRIPPER

SF06. Machine Safety Solutions Overview

2010 APPLICATION REFERENCE GUIDE

3. Loosen 3 x grub screws in the Dec end cap and unscrew the cap and counterweight shaft. NEQ6 Belt Modification Kit.

Model 2300DR Installation Guide

SAFETY MANUAL SIL SWITCH AMPLIFIER

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Failure Modes, Effects and Diagnostic Analysis

HISTORY IN THE BRAKING

AMG Antrieb und Mechanik GmbH

Introduction to JIGS AND FIXTURES

Rear wheel brakes, servicing. Стр. 1 из 45. Note:

Steering column, steering column tube and steering wheel, servicing

Porsche Service. Cayenne (from MY 2008 for the following countries:

TÜV Rheinland Functional Safety Program Functional Safety Engineer Certification

Version: 1.0 Latest Edition: Guideline

SINAMICS drives SINAMICS DCM. DC converters from 6 kw to 2500 kw for variable-speed direct-current drives. Load-balanced control application

Translation assembly instructions with operating manual and technical appendix

Using Design Accelerators in Autodesk Inventor

Applications of Mechanical Systems in Engineering

Design, construction and engineering Electrical designing Electronics development Software development Switch cabinet construction Testing facilities

Tool Holder Catalog INDEX ABC VDI 25 LL /Rö

STANDARD PRACTICE INSTRUCTION

ABB industrial drives. Application guide ACS800-01/U1/04/04LC/04M/U4/11/U11/14/31/U31/104/104LC Safe torque off function (+Q967)

ŠKODA MACHINE TOOL HORIZONTAL MILLING AND BORING MACHINES ŠKODA HCW

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

Contactor Monitoring Relay CMD Cost-Effective Solution for Safe Machines

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Rules of Actuator and Guide Alignment in Linear Motion Systems

FMEDA and Proven-in-use Assessment. Pepperl+Fuchs GmbH Mannheim Germany

Transcription:

Industry Siemens AG, I IA CD, P.O. box 48 48, D-90026 Nuremberg Name Patrick Gehlen Bernard Mysliwiec Department I IA Telephone +49 911 895-5900 Fax +49 911 895-5907 Mobile E-mail technical-assistance@siemens.com Your letter Our reference PG-BM, PositionswitchPLdCat3SIL2, Date April 22, 2009 Achievement of Performance Level PL d with Category 3 according to ISO 13849-1 or SIL 2 according to IEC 62061 with application of only one SIRIUS Position switch with or without solenoid interlocking (type 2) or only one SIRIUS Hinge switch General If an electromechanical position switch fulfils the requirements of ISO 13849-1, Annex K, then, due to EN ISO 13849-2, it is about a so called well-tried component. To achieve Performance Level PL d with Category 3 according to ISO 13849-1 under use of only one position switch or only one hinge switch as well-tried component, fault exclusions shall be defined for the electrical portion as well as for the mechanical portion of the position switch (and where required also for the approach mechanism). The international standard ISO 13849-1 allows fault exclusions (see section 7.2): in this case the constructor of a machine has to indicate how these fault exclusions are justified (by description of conditions for the well-tried methods etc.). By application of well-tried safety principles, fault exclusions for mechanical systems are legitimated, too: Thus by appropriate fastening (constructive measure) of the position switch and the separate actuator a fracture of the separate actuator can be excluded (see page 5 of this letter). With means of an additional 2-channel electrical version (with positive opening contacts) of the position switch it is possible to accomplish Performance Level PL d with Category 3 according to ISO 13849-1. Application and fastening shall always be carried out considering the manufacturer instructions under the declared specifications and they must not change in the period of operation. Since the machine manufacturer has to supply evidence for fault exclusion, the component manufacturer can not issue a final statement about the measures implemented. The constructional determined fastening of the position switch or the hinge switch to a rotary axis lets a fault exclusion for Performance Level PL e with Category 4 according to ISO 13849-1 appear rather questionably. However, for an application with Performance Level PL d with Category 3 according to ISO 13849-1 a fault exclusion is conceivable (likewise similar interpretation at the position switches with or without solenoid interlocking, e.g. for machine tools). Siemens AG Industry Sector Management: Heinrich Hiesinger Postal address: Siemens AG I IA CD P.O. box 48 48 D-90026 Nuremberg Siemens Aktiengesellschaft: CEO of the Supervisory Board: Gerhard Cromme Executive Board: Peter Löscher, CEO; Wolfgang Dehen, Heinrich Hiesinger, Joe Kaeser, Barbara Kux, Hermann Requardt, Siegfried Russwurm, Peter Y. Solmssen Corporate domiciles: Berlin and Munich; register courts: Berlin Charlottenburg, HRB 12300, Munich, HRB 6684 WEEE Reg. No. DE 23691322 Office address: Gleiwitzer Str. 555 Moorenbrunn D-90475 Nuremberg Tel.: +49 911 895 5900 Fax: +49 911 895 5907 ISO13849IEC62061SIRIUS3SEPLd-KAT3-SIL2Info1en.doc Page 1 of 5

Our reference PG-BM, PositionswitchPLdCat3SIL2, Belowmentioned standards include some remarks on this issue which approve this interpretation. Important note: As far as a C-Standard stipulates the application of two position switches for category 3 according to ISO 13849-1, then this st ipulation always has to be considered as mandatory. Requirements for Fault exclusions according to ISO 13849-1 In section 7.3 there is following described: It is not always possible to evaluate SRP/CS without assuming that certain faults can be excluded. For detailed information on fault exclusions, see ISO 13849-2. Fault exclusion is a compromise between technical safety requirements and the theoretical possibility of occurrence of a fault. Fault exclusion can be based on - the technical improbability of occurrence of some faults, - generally accepted technical experience, independent of the considered application, and - technical requirements related to the application and the specific hazard. If faults are excluded, a detailed justification shall be given in the technical documentation. Basic safety principles and Fault exclusions due to ISO 13849-2 Annex A quotes several remarks on mechanical systems : Table A.1 Basic safety principles Basic safety principles Proper selection, combination, arrangements, assembly and installation of components/system Proper fastening Limitation of the generation and/or transmission of force and similar parameters Remarks Apply manufacturer's application notes, e. g. catalogue sheets, installation instructions, specifications, and use of good engineering practice in similar components/systems. For the application of screw locking consider manufacturer's application notes. Overloading can be avoided by applying adequate torque loading technology Examples are break pin, break plate, torque limiting clutch. Table A.4 Mechanical devices, components and elements (e. g. cam, follower, chain, clutch, brake, shaft, screw, pin, guide, bearing) Fault considered Fault exclusion Remarks Fracture Yes, in the case of carefully selected material, (over)dimensioning, manufacturing process, treatment and proper lubrication, according to the specified life-time (see also Table A.2). See ISO 13849-1, 7.2 Remark: This also applies for corrosion, untightening, loosening, deformation and stiffness or sticking. ISO13849IEC62061SIRIUS3SEPLd-KAT3-SIL2Info1en.doc Page 2 of 5

Our reference PG-BM, PositionswitchPLdCat3SIL2, Requirements according to IEC 62061 In this standard there are made statements which allow an interpretation how to achieve a SIL CL 2 with only one position switch with or without solenoid interlocking (Type 2) or with only one hinge switch. Systematic safety integrity The Fault exclusion regarding any misfunction of the separated actuator is part of the aspect of the systematic failures (see section 6.4.1 Requirements for the avoidance of systematic hardware failures). The standard takes reference to the abovementioned measures as per EN 1088 and ISO 13849-2 and therefore admits this Fault exclusion. Hardware safety integrity A position switch with or without solenoid interlocking (type 2) or a hinge switch represents a subsystem. By Architectural constraints (see section 6.7.6 Architectural constraints on hardware safety integrity of subsystems) it is possible to achieve a SIL CL at the level of SIL 2: An estimation of Safe Failure Fraction (SFF) is assessed with 80% (see table D.1). A graduation of the fault of internal mechanical construction of the position switch with or without solenoid interlocking (type 2) or the hinge switch as very unprobably results into a hardware fault torerance of 1. Remarks: When judging about the mechanical construction of the position switch with or without solenoid interlocking or the hinge switch the B10-value offers a quantitative statement about the failure rate with respect to the failure rate in a level of e.g. ca. 1 million switching cycles angegeben. In further qualitative aspects of EN 62061 this value plays a significant role for achievment of a safety integrity. However, by this Fault exclusion the standard sets a limitation of the SIL CL to a maximum of SIL 2: In section 6.7.7.2 of IEC 62061 thisregarding is written:... EXCEPTION: For a subsystem with a hardware fault tolerance of zero and where fault exclusions have been applied to faults that could lead to a dangerous failure, then the SILCL due to architectural constraints of that subsystem is constrained to a maximum of SIL 2.... In table 6, with a hardware fault tolerance of 1 and a SFF = 80%, the achievable SIL CL = SIL 2. Achievable Safety Integrity Level SIL After this, the above descripted subsystem is recommended for SIL 2: SIL CL = SIL 2. ISO13849IEC62061SIRIUS3SEPLd-KAT3-SIL2Info1en.doc Page 3 of 5

Our reference PG-BM, PositionswitchPLdCat3SIL2, Tasks for the constructor of a machine The BG-Information BGI 575 offers lots of hints and kinks to the constructor and even the maintenance personal for properly selection and fixation of electromechanical position switches in safety applications. The following is an extract of some important hints. Selection of recommended components (translated from german original version) For a functional safe application of position switches for safety functions it is mandatory to follow the user informations (technical data, assembly instructions, wiring instructions), e.g.: - by eventual limitation of permissible mounting position - by a distinct fixation, when the fixation of the interlocking mechanism allows for alteration, - by actuating velocity, actuating direction, actuating angle, - by inhibition of the usage of locking units as mechanical stop, - by required short circuit protection devices, - by the mechanical lifetime, - by circuit proposals, additionally for solenoid interlockings: - by a possible restriction of the range of application at solenoid force operation (open circuit principle), - by the interlocking force, - by functionally correct installation with regard to a safe mode of operation, The protection of the position switches against ingression of solid-state and fluid contamination shall be adequate considering external influences under which the switch is employed (e.g. dust, lubricating coolants and metal cuttings). By pollution of the mechanical components which are stired by the actuator there can emerge frictional forces which in extreme situations can result into destruction of mechanics and to a dangerous failure of the switch. Above all, the constructor shall consider any possible pollution of the selected component and the process specific influences (e.g. enamel-mist, moisture, metal chips ) which could lead to a failure of the safety function. Allocation (assembly) Properties for the appropriate allocation of position switches are e.g. - Positive locking over the entire operation travel of the position switch until positive opening operation, - Allocation and wiring of the switch as positive opening contact and safe evaluation of the signal, - Adjustment of operation travel adequate to the positive opening travel due to manufacturer instruction (picture 17), - Positive locked fixation (torsion and shift proof allocation) of the switch and the final controlling element (cam disk, linear stem), no oblong hole mounting without additional fixation (picture 27), - Fastening the mounting elements of the switch and the final controlling element (cam disk, linear stem) against self-loosening, - Sufficient mechanical stability of cxarrier and functional elements - For the interlocking mechanisms, Fastening against alteration of position (fixation) To assure against alterating position of position switches for safety functions it is mandatory to provide positive locking fixations for the assembly, e.g. - by round holes, - by oblong holes with additional application of dowel pins or mechanical stops. The constructor shall consider that self-loosening of the position switch is impossible by selection of a proper mechanical fixation. Furthermore, the position switch or hinge switch shall be protected from environmental influences at any time. ISO13849IEC62061SIRIUS3SEPLd-KAT3-SIL2Info1en.doc Page 4 of 5

Our reference PG-BM, PositionswitchPLdCat3SIL2, Safeguarding the obtainment of implemented measures While using a machine (in regular operation and also in maintenance) the safety function shall be safeguarded at any time. This is assured by the maintenance intervals as described in the user manual of the machine. Examples for constructive measures The application of position switches or hinge switches due to their original destination of use shall be warranted at any time: This shall always be considered by the constructor of the machine (however this does not depend on the stipulated Performance Level PL d with Category 3 according to ISO 13849-1 or SIL due to IEC 62061). Possible constructive measures (high protection against failure) can be like this: Protection against self loosening (e.g. welding, riveting) Positive locking after fixation (e.g. bolts or dowel pins); Never use position switches as mechanical end stop; Obtain velocity, direction and angle of operation due to manufacturer prescriptions Consider damages caused by predictable environmental influences: any materials (e.g. dirt, dust, metal chips, enamels,... ) which could lead to a failure or even a destruction of the position switch shall be kept away by the mode of installation and mounting. General: Maintenance of positions switches or hinge switches shall always be carried out in regular or rational intervals considering their operation manuals. Evaluation report This letter has been checked by Center for Quality Engineering and TÜV Rheinland Group and the contents have been approved as correct. The evaluation results are issued in the evaluation report U0SZ0001, as per date May 9th, 2006. For further requests please consult Technical Assistance:. Internet: Email: www.siemens.de/lowvoltage/technical-assistance technical-assistance@siemens.com Yours sincerely, Patrick Gehlen Bernard Mysliwiec Disclaimer: The information provided herein is unbinding and does not claim to be complete or to consider all contingencies. The information does not represent any customer-specific solution, but merely serves as support with typical tasks. You are solely responsible for the appropriate use of this information. This information does not exempt you from your obligation to due diligence with regard to application, installation, operation and maintenance. By using this information, you acknowledge that Siemens cannot be held responsible for any damage. We reserve the right to implement changes in this letter at anytime and without prior notice. In case of deviations between the information contained herein and other Siemens publications, for example catalogs, the content of such other documentation shall have priority. ISO13849IEC62061SIRIUS3SEPLd-KAT3-SIL2Info1en.doc Page 5 of 5