74 Chapter 5. 5.5 CO 2 Cleaning



Similar documents
VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

Contents. Introduction... A Note About Heatsinks... Precautions...

MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL

Care and Use of the Compound Microscope

Owner s Manual

Operator s Maintenance Manual STEINER BINOCULARS. Military ruggedness and precision 07/03

CLEAN ROOM TRAINING CLEAN ROOM AREAS

Vacuum Tube Solar Water heater Non-pressure. User manual

PREVENTIVE MAINTENANCE OF FIBER OPTIC CABLES AND OPTICS

Contents. Introduction... A Note About Heatsinks... Precautions...

Diesel Fuel Systems. Injection Nozzles

Peasouper Operator s Manual

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

Inspection and Cleaning Procedures for Fiber Optic Connections

Care and Handling of Your VAIO Computer

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

During Various Aluminum Fabricating Operations

HAIR CLIPPER. Model No. HC5150 HC

Oxidation States of Copper Two forms of copper oxide are found in nature, copper(i) oxide and copper(ii) oxide.

sciencemuseumoutreach Kitchen Science 1 Demonstrations to do at home

DASH KIT INSTALLATION

LiquaCast Liquid Molding Rubber INSTRUCTIONS

Separation of Amino Acids by Paper Chromatography

Features: Mounting the Optic

TEC APO140. This telescope is closer to optical perfection more than any instrument I have ever used before. R.Renzi, Italy.

Partnerships Implementing Engineering Education Worcester Polytechnic Institute Worcester Public Schools Supported by: National Science Foundation

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

Recommended Procedures for Use of YSI Water Quality Monitoring Instruments during Oil Spills

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

Paper Chromatography: Separation and Identification of Five Metal Cations

Solvent Cementing Instructions For Plastic Pipe & Fittings

Standards A complete list of the standards covered by this lesson is included in the Appendix at the end of the lesson.

Active and Passive Sash Replacement

Almond SPAMANICURE. Step-by-Step Guide INDULGENT AND RELAXING

VISM CQB Scope Series

Technical Cleaning Ó

Scotchgard Multi-Layer Protective Film 1004

Tractor Painting Tips

Installation Instructions

12 cup programmable coffee maker

How to Clean and Care for Reclaimed Wood Furniture

AF 70~300 mm F/4-5.6 Di LD Macro 1:2 (Model A17)

MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY

FirstView 3 Reflector Telescope Owner s Manual

McDonald s Kitchen Cleaning Instructions. Prepared for: Employees of McDonald s

Digital Photo Picture Frame. Operation Manual

PTFE Slide Bearings 04/10 149

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Making A Mirror Grinding Tool By Allen Malsburry

Transferring a Broth Culture to Fresh Broth

Mixtures and Pure Substances

VISM Evolution Scope Series

Aspect Metal Peel & Stick Tile Installation Guide

Portable Steam Cleaner

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY. STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 079 MOD: 1st Issue Page: 1 of 7

WET CLEANING MANUAL. Wet Cleaning instructions Wet Cleaning best practices Liquid Solution Maintenance

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com

FSP08 i mpr e ssi o n s

A Fishy Tale. Observing the Circulatory System of a Goldfish with a Compound Light Microscope

Table of Contents Markers...1

Minor Cracks in Horizontal Surfaces

1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time

Air Hockey Training Camp Care and repair of your Air Hockey Playfield

Experiment 12- Classification of Matter Experiment

EF70-300mm f/4-5.6 IS USM

Operating manual ICC Camera. Version Menu

A. Work on this project shall consist of, but is not limited to, the following:

INSTRUCTIONS. FLHR/C/S (Road King) FRONT END LOWERING KIT 1WARNING -J03242 REV General. Removal (Left and Right Forks) Kit Number

Bathroom Installation Guide

Brisa UV Gel Enhancements Sculpted on a Tip

BedRug Bedliner Installation Instructions. Part Number(s): Multiple. Preparation

Step-by-Step Guide. ENHANCEMENTS Brisa UV Gel Enhancements Rebalancing. STEP 1: Cleanse

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

TECHNISCHE FICHE - TECHNISCHE FICHE - Chat Board: Classic

- 2 - IMPORTANT SAFETY REMINDERS

IMPORTANT! For best results, go to. for Video Tips & Techniques USER MANUAL. InStyler Wet 2 Dry Rotating Iron

Please read and keep these instructions. Run water through your machine before first use

18-270mm F/ Di II VC PZD for Canon, Nikon (Model B008) mm F/ Di II PZD for Sony (Model B008)

1. The Determination of Boiling Point

Waxing guide for recreational and fitness skiers

Heat. LD Physics Leaflets. Determining the adiabatic exponent c P /c V of various gases using the gas elastic resonance apparatus P2.5.3.

K2 STONE NATURAL VENEER

Never use a spa or hot tub alone. Do not allow children to use a spa without supervision.

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

5.3 Cleaning the Printer

Physical and Chemical Properties and Changes

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.

Care and Maintenance for Wood Flooring

Mechanical Energy. Mechanical Energy is energy due to position or motion.

Flushing and Cleaning the A/C System

CLEANING GUIDE.

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.

Experiment 7: Titration of an Antacid

CHEM 2423 Recrystallization of Benzoic Acid EXPERIMENT 4 - Purification - Recrystallization of Benzoic acid

Smartstrand Cleaning Guidelines

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

Air Hockey Training Camp Care and repair of your Air Hockey Playfield

Transcription:

74 Chapter 5 5.5 CO 2 Cleaning The CO 2 method involves spraying CO 2 snow against the optical surface. Snow is made using a specialized nozzle (Fig. 5.7) that expands the gas or liquid through an orifice. The snow is propelled at a high velocity, so the impact of the snow strikes any particles or contaminants off the surface. Particles of all sizes, from the visible down to 0.03 μm, and hydrocarbons are removed quickly. 11 Figures 5.8 and 5.9 illustrate the effect of this cleaning on an optical surface. This method is used for critical optics like lasers, telescopes, enclosed, or hard-to-reach optics (within the line of sight from the nozzle to the surface). It may be possible for the snow to reach into grooves and around tubes. CO 2 can be used as an interim or the final cleaning step. The CO 2 hardware and the workstation should be in a very clean environment to reduce the chance of re-contamination. Special particle filters such as a HEPA should be used in the cleanroom and/or flow bench. To purge the area and keep the moisture level low, the use of dry air or nitrogen may be required as part of the cleaning. Follow the manufacturer s instructions on the setup and use of the hardware. Figure 5.7 CO 2 nozzle and control applicator with a pressure gauge (image courtesy of Applied Surface Technologies).

Special Cleaning Processes 75 Figure 5.8 Optical surface before the CO 2 cleaning process (image courtesy of Applied Surface Technologies). Figure 5.9 Optical surface after the CO 2 cleaning process (image courtesy of Applied Surface Technologies). The use of a warming plate, heat lamp, warming box, or other warming method is sometimes required to reduce moisture condensation during spraying. A dry box or a nitrogen shroud are alternatives. Caution should be used when applying the cold CO 2 to thermally

76 Chapter 5 sensitive optics or a localized area on very thick glass; be sure to test the procedure on samples. When using CO 2, a static charge build-up is possible and should be addressed. Observe the effectiveness of the procedure and make adjustments. Select several samples and vary the procedure. On coatings, use the CO 2 process cautiously if the coating has not adhered to the glass, the snow can remove it. An improperly bonded coating can be broken off. 9 The optic needs to be properly supported at all times and should be secured. The nozzle should be pointed away from the clean parts and the snow should flow away from them. For safety reasons, the area should have good airflow. Do not let the CO 2 and nitrogen accumulate in the room or under the flow bench. 5.6 Ultrasonic Cleaning Ultrasonic cleaning uses sound waves to clean optics. The process removes hard-to-clean contaminants from the surfaces and sides of an optic. It can be scaled to handle one optic at a time or hundreds as part of a large cleaning line. A small hobby ultrasonic cleaner can be used for experimental cleaning; they are typically used for small items such as jewelry. A cleaner of this size can handle optics up to 50 60 mm. As a precaution, test a few samples of the type of glass to be cleaned and observe the effect of the ultrasonic process on the glass. The mixture of cleaning liquids and the agitation of the ultrasonic waves can have adverse effects. Although benign when used alone, combining sound waves and cleaning liquids candamageanoptic. Start by pouring a simple soap-and-water mixture into an ultrasonic tub. This mixture is used to clean polishing compounds off of the edges of an optic, and oils and fingerprints from the surfaces. The percentage of soap to water should be about 1% of the volume of water.

Special Cleaning Processes 77 A simple plastic holder or rack is recommended to place the optic in the cleaner; it should have an open design to allow for proper cleaning. The optic should be held on its edge or laid flat, and secured to prevent movement during cleaning (in such a way that the optical surface does not touch the insides or bottom of the cleaning chamber). This precaution prevents vibrations from causing subsurface damage to the optical surface. Leave the optic in the cleaner and bath for a limited amount of time: the process should be monitored every 30 90 s. 5.7 Carbon-Tip Cleaning This method uses a fine carbon powder that is embedded in felt or chamois material. The cleaning process is very similar to the chalk method, where a fine powder scrubs and absorbs oils and other contaminants. It works best on uncoated optical surfaces or coated surfaces with hard AR coatings. Carbon tips have the advantage of removing oils and stains without the use of liquids, and the felt or chamois softness reduces the risk of scratching the optical coating or surface. A carbon wipe can be used on flat surfaces, such as tablets, screens (e.g., computers and smartphones; see Fig. 5.10), and windows. Do not use carbon tips on soft coatings such as unprotected front-surfacemirror coatings. If in doubt, test on a sample first. Review and follow the manufacturer s instructions on its use and limitations. Also, do not use carbon tips on optical surfaces that have large amounts of moisture, dirt, or oils, as they will be less effective. Moisture and oils will be absorbed into the felt, chamois tip, or wipe. The carbon-tip tool has a fine brush attached on the opposite end of the tool; the brush is used first to remove large dust particles (see Fig. 5.11). When finished, remove the cap covering the carbon tip (note that it contains a small amount of carbon powder to replenish the tip). The tip is then lightly pressed against the optical surface and slowly moved in a spiral motion from the center out to the edge (Fig. 5.12). During the final rotation, lift the tip up and away from the surface.

78 Chapter 5 Figure 5.10 Cleaning the surface of a cell phone screen using a carbon-tip wipe. Figure 5.11 Cleaning the eye lens of an eyepiece with a small brush before using the carbon tip.