AmpliSens Toxoplasma gondii-frt PCR kit



Similar documents
PCR kit. AmpliSens CMV-EPh. Instruction Manual. For Professional Use Only

RealLine HCV PCR Qualitative - Uni-Format

HBV PCR detection Kit USER MANUAL

HBV Quantitative Real Time PCR Kit

RealStar HBV PCR Kit /2012

Human Herpes Virus 4 (Epstein Barr)

mircute mirna qpcr Detection Kit (SYBR Green)

Epstein Barr Virus (Human Herpes virus 4) nonglycosylated membrane protein (BNRF1) gene. genesig Advanced Kit. DNA testing

Intended Use: The kit is designed to detect the 5 different mutations found in Asian population using seven different primers.

Epstein Barr Virus (Human Herpes virus 4) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

Application Guide... 2

STA DARD OPERATI G PROCEDURE FOR THE DETECTIO OF AFRICA SWI E FEVER VIRUS (ASFV) BY REAL-TIME POLYMERASE CHAI REACTIO (PCR)

Genomic DNA Extraction Kit INSTRUCTION MANUAL

Human Herpes Virus 1 (Herpes simplex type 1) genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere...

User Manual. CelluLyser Lysis and cdna Synthesis Kit. Version 1.4 Oct 2012 From cells to cdna in one tube

PNA BRAF Mutation Detection Kit

Quantification of Mycobacterium Tuberculosis. 150 tests

altona altona RealStar Clostridium difficile PCR Kit 1.0 always a drop ahead. 11/2012 altona Diagnostics GmbH Moerkenstr Hamburg Germany

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

MystiCq microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C

MagExtractor -Genome-

Genomic DNA detection assay

PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

RNA Extraction and Quantification, Reverse Transcription, and Real-time PCR (q-pcr)

Lyme Disease. RecA gene. 150 tests. Quantification of Lyme Disease genomes. Advanced kit handbook HB

BacReady TM Multiplex PCR System

HiPer RT-PCR Teaching Kit

NimbleGen DNA Methylation Microarrays and Services

DNA Isolation Kit for Cells and Tissues

One Shot TOP10 Competent Cells

ab Hi-Fi cdna Synthesis Kit

Instruction manual for product # PNAC Version 1.2

UltraClean Soil DNA Isolation Kit

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

GenScript BloodReady TM Multiplex PCR System

Blood Collection and Processing SOP

QuickZyme Soluble Collagen Assay

empcr Amplification Method Manual - Lib-A

50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage.

Agencourt RNAdvance Blood Kit for Free Circulating DNA and mirna/rna Isolation from μL of Plasma and Serum

FOR REFERENCE PURPOSES

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

TransformAid Bacterial Transformation Kit

Quantitative Real Time PCR Protocol. Stack Lab

STA DARD OPERATI G PROCEDURE FOR THE DETECTIO OF AFRICA SWI E FEVER VIRUS (ASFV) BY CO VE TIO AL POLYMERASE CHAI REACTIO (PCR)

First Strand cdna Synthesis

ncounter Gene Expression Assay Manual Total RNA and Cell Lysate Protocols

quantitative real-time PCR, grain, simplex DNA extraction: PGS0426 RT-PCR: PGS0494 & PGS0476

Thermo Scientific DyNAmo cdna Synthesis Kit for qrt-pcr Technical Manual

ELISA-VIDITEST-MICROCYSTIN LR Lot: XX

ExpressArt Bacterial H-TR cdna synthesis kit. With extreme selectivity against rrnas

All-in-One mirna qrt-pcr Reagent Kits For quantitative detection of mature mirna

Real-time quantitative RT -PCR (Taqman)

Dengue Virus subtypes 1,2 3 and 4. genesig Standard Kit. DNA testing. Everything... Everyone... Everywhere... 3 Untranslated Region (3 UTR) 150 tests

ABSTRACT. Promega Corporation, Updated September Campbell-Staton, S.

Terra PCR Direct Polymerase Mix User Manual

UltraClean PCR Clean-Up Kit

RealLine Borrelia burgdorferi s.l. Fla-Format

ab83369 Alkaline Phosphatase Assay kit (Colorimetric)

Plant Genomic DNA Extraction using CTAB

Kevin Bogart and Justen Andrews. Extraction of Total RNA from Drosophila. CGB Technical Report doi: /cgbtr

Aptima Specimen Transfer Kit

PATHOGEN DETECTION SYSTEMS BY REAL TIME PCR. Results Interpretation Guide

GRS Plasmid Purification Kit Transfection Grade GK (2 MaxiPreps)

Canine Creatine Kinase MM isoenzyme(ck-mm) ELISA. kit

All-in-One mirna qrt-pcr Detection System Handbook

RevertAid Premium First Strand cdna Synthesis Kit

Technical Manual No Update Date

Lyme Disease RecA gene. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere tests. Primerdesign Ltd.

Aurora Forensic Sample Clean-up Protocol

Table of Contents. I. Description II. Kit Components III. Storage IV. 1st Strand cdna Synthesis Reaction... 3

Borrelia burgdorferi

HiPer Total RNA Extraction Teaching Kit

Streptococcus pneumoniae

Classic Immunoprecipitation

Essentials of Real Time PCR. About Sequence Detection Chemistries

Quantification of Hepatitis B Virus. Core Protein Region. 150 tests

Hepatitis B Virus. genesig Advanced Kit. DNA testing. Everything... Everyone... Everywhere... Core Protein Region. 150 tests.

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Anti-Zona Pellucida Antibody Latex Agglutination Test

Mouse krebs von den lungen 6 (KL-6) ELISA

Arcturus PicoPure RNA Isolation Kit. User Guide

Data Sheet. PD-L1:B7-1[Biotinylated] Inhibitor Screening Assay Kit Catalog # Size: 96 reactions

TIANquick Mini Purification Kit

RT-PCR: Two-Step Protocol

RT rxns. RT rxns TRANSCRIPTME Enzyme Mix (1) 40 µl 2 x 50 µl 5 x 40 µl

DNA IQ System Database Protocol

Standard Operating Procedure (SOP) Work Package 8. Sample Collection and Storage

Human Free Testosterone(F-TESTO) ELISA Kit

Quantification of Propionibacterium acnes. Standard kit 150 tests

Path-ID Multiplex One-Step RT-PCR Kit

Human Peripheral Blood Mononuclear Cell (PBMC) Manual

DyNAmo cdna Synthesis Kit for qrt-pcr

Crime Scenes and Genes

ID kit. imegen Anchovies II. and E. japonicus) DNA detection by. User manual. Anchovies species (E. encrasicolus. sequencing.

DNA Analyst Training Laboratory Training Manual Protocol 2.02 Clean Technique

Chromatin Immunoprecipitation (ChIP)

Klebsiella oxytoca. Outer membrane protein II (ompa) gene. 150 tests. Quantification of Klebsiella oxytoca genomes. Advanced kit handbook HB10.03.

Transcription:

For Professional Use Only AmpliSens Toxoplasma gondii-frt PCR kit Instruction Manual AmpliSens Federal Budget Institution of Science Central Research Institute for Epidemiology 3A Novogireevskaya Street Moscow 111123 Russia

TABLE OF CONTENTS 1. INTENDED USE... 3 2. PRINCIPLE OF PCR DETECTION... 3 3. CONTENT... 4 4. ADDITIONAL REQUIREMENTS... 4 5. GENERAL PRECAUTIONS... 5 6. SAMPLING AND HANDLING... 6 7. WORKING CONDITIONS... 7 8. PROTOCOL... 7 9. DATA ANALYSIS... 8 10. TROUBLESHOOTING... 9 11. TRANSPORTATION... 10 12. STABILITY AND STORAGE... 10 13. SPECIFICATIONS... 10 14. REFERENCES... 10 15. QUALITY CONTROL... 11 16. KEY TO SYMBOLS USED... 11 REF R-P1(RG,iQ,Mx)-CE-B / VER 16.12.09 16.05.11 / Page 2 of 12

1. INTENDED USE AmpliSens Toxoplasma gondii-frt PCR kit is an in vitro nucleic acid amplification test for qualitative detection of Toxoplasma gondii DNA in the clinical material (peripheral blood, umbilical cord blood, white cells of peripheral or umbilical cord blood, biopsy and autopsy material, cerebrospinal fluid, and amniotic fluid) by means of real-time hybridization-fluorescence detection. The results of PCR analysis are taken into account in complex diagnostics of disease. 2. PRINCIPLE OF PCR DETECTION Toxoplasma gondii detection by the polymerase chain reaction (PCR) is based on the amplification of pathogen genome specific region by using specidic primers. In real-time PCR, the amplified product is detected using fluorescent dyes. These dyes are linked to oligonucleotide probes that bind specifically to the amplified product. The real-time monitoring of the fluorescence intensities during the real-time PCR allows the detection of accumulating product without re-opening the reaction tubes after the PCR run. AmpliSens Toxoplasma gondii-frt PCR kit uses hot-start, which greatly reduces the frequency of nonspecifically primed reactions. Hot-start is guaranteed by separation of nucleotides and Taq-polymerase by using chemically modified polymerase (TaqF), which is activated by heating at 95 C for 15 min. Toxoplasma gondii DNA detection in clinical samples includes: (a) Total DNA extraction from white blood cells of peripheral and umbilical cord blood, biopsy and autopsy material, cerebrospinal fluid, and amniotic fluid simultaneously with the exogenous Internal Control. (b) Multiplex real-time PCR of a DNA fragment of a nonstructural repeated gene (529 bp long) encoding Toxoplasma gondii protein and an artificial DNA fragment cloned into phage, which is used as a noncompetitive exogenous Internal Control. Toxoplasma gondii DNA amplification is detected in the JOE/Yellow/HEX channel, the noncompetitive exogenous Internal Control amplification is detected in the FAM/Green channel. The exogenous Internal Control allows monitoring the main steps of PCR analysis (DNA extraction and amplification). The main advantage of a noncompetitive exogenous Internal Control is the extension of the linear detection range and, therefore, an increase in the analytical sensitivity of the test. REF R-P1(RG,iQ,Mx)-CE-B / VER 16.12.09 16.05.11 / Page 3 of 12

3. CONTENT AmpliSens Toxoplasma gondii-frt PCR kit is produced in 1 form: AmpliSens Toxoplasma gondii-frt PCR kit variant FRT-50 F in bulk 1 (for use with RG, iq, Mx) REF R-P1(RG,iQ,Mx)-CE-B. AmpliSens Toxoplasma gondii-frt PCR kit variant FRT-50 F includes: Reagent Description Volume, ml Quantity PCR-mix-1-FRT Toxoplasma gondii colorless clear liquid 0.6 1 tube PCR-mix-2-FRT colorless clear liquid 0.3 1 tube Polymerase (TaqF) colorless clear liquid 0.03 2 tubes Positive Control DNA Toxoplasma gondii and STI (С+) colorless clear liquid 0.1 1 tube DNA-buffer colorless clear liquid 0.5 1 tube Negative Control (C-)* colorless clear liquid 1.2 1 tube Internal Control STI-87 (IC)** colorless clear liquid 1.0 1 tube * must be used in the extraction procedure as Negative Control of Extraction. ** add 10 µl of Internal Control STI-87 during the DNA extraction procedure directly to the sample/lysis mixture (see RIBO-prep, REF K1-9-Et-50-CE, DNA-sorb-C REF K1-6-50- CE protocols). AmpliSens Toxoplasma gondii-frt PCR kit is intended for 60 reactions (including controls). 4. ADDITIONAL REQUIREMENTS DNA extraction kit. Disposable powder-free gloves and laboratory coat. Pipettes (adjustable). Sterile pipette tips with aerosol barriers ( up to 200 µl). Tube racks. Vortex mixer. Desktop centrifuge with a rotor for 2-ml reaction tubes. PCR box. Personal thermocycler (for example, Rotor-Gene 3000 or Rotor-Gene 6000 (Corbett Research, Australia), icycler iq or iq5 (BioRad, USA), Mx3000P/Mx3005P (Stratagene, USA)). 1 In bulk form contains unlabeled tubes. Tubes with identical reagent are packed in one bag with label. REF R-P1(RG,iQ,Mx)-CE-B / VER 16.12.09 16.05.11 / Page 4 of 12

Disposable polypropylene microtubes for PCR (0.1- or 0.2-ml; for example, Axygen, USA). Refrigerator for 2 8 C. Deep-freezer for 16 C. Waste bin for used tips. 5. GENERAL PRECAUTIONS The user should always pay attention to the following: Use sterile pipette tips with aerosol barriers and use new tip for every procedure. Store extracted positive material (samples, controls and amplicons) away from all other reagents and add it to the reaction mix in a separate area. Thaw all components thoroughly at room temperature before starting an assay. When thawed, mix the components and centrifuge briefly. Use disposable gloves, laboratory coats and eye protection when handling specimens and reagents. Thoroughly wash hands afterwards. Do not eat, drink, smoke, apply cosmetics, or handle contact lenses in laboratory work areas. Do not use a kit after its expiration date. Dispose of all specimens and unused reagents in accordance with local regulations. Specimens should be considered potentially infectious and handled in a biological cabinet in accordance with appropriate biosafety practices. Clean and disinfect all sample or reagent spills using a disinfectant, such as 0.5% sodium hypochlorite or another suitable disinfectant. Avoid sample or reagent contact with the skin, eyes and mucous membranes. If skin, eyes, or mucous membranes come into contact, rinse immediately with water and seek medical advice immediately. Material Safety Data Sheets (MSDS) are available on request. Use of this product should be limited to personnel trained in DNA amplification techniques. The laboratory process must be one-directional, it should begin in the Extraction Area and then move to the Amplification and Detection Areas. Do not return samples, equipment and reagents to the area in which the previous step was performed. Some components of this kit contain sodium azide as a preservative. Do not use metal tubing for reagent transfer. REF R-P1(RG,iQ,Mx)-CE-B / VER 16.12.09 16.05.11 / Page 5 of 12

6. SAMPLING AND HANDLING Obtaining of biological material samples for PCR-analysis, transportation and storage are described in manufacturer s handbook [1]. It is recommended that this handbook is read before starting work. AmpliSens Toxoplasma gondii-frt PCR kit is intended to analyze DNA extracted with DNA extraction kits from: Whole peripheral and umbilical cord blood White cells of peripheral or umbilical cord blood Biopsy and autopsy material Cerebrospinal fluid Amniotic fluid 6.1. Whole peripheral and umbilical blood. Blood should be collected to a tube with 6% EDTA solution at a ratio 20:1 (20 portions of blood per 1 portion of EDTA) after overnight fasting. Umbilical cord blood is obtained by cordocentesis. Invert the tube several times to ensure proper mixing. Do not freeze the whole blood samples! 6.2. White blood cells taken from peripheral and/or umbilical cord blood are to be treated with Hemolytic REF 137. To do this, add 1.0 ml of Hemolytic and 0.25 ml of whole blood to a 1.5-ml tube, vortex, and centrifuge (8,000 rpm, 2 min). Remove the supernatant leaving 100 µl of fluid over the sediment. Cell pellet should be white after washing. The presence of a small amount of a pinkish film-like pellet above the major part of cell pellet is allowed. Add 300 μl of Solution for Lysis to the tube with the obtained leukocyte sample (for RIBO-prep protocol). 6.3 Biopsy and autopsy material is obtained from the expected location of the pathogen, from the damaged tissue or from the area adjoining with the damaged tissue. Collect the samples to a 2-ml tube with 0.3 ml of transport medium. Transfer the sample to a porcelain mortar; add an equal volume of saline or PBS. Thoroughly homogenize the specimen with a porcelain pestle. Take a 100-μl aliquot and transfer to a sterile tube for DNA extraction. 6.4. Cerebrospinal fluid should be obtained by the standard procedure and collected to a sterile Eppendorf tube. 6.5. Amniotic fluid should be obtained during amniocentesis by the standard procedure and collected to a sterile Eppendorf tube. Thoroughly resuspend the obtained sample and transfer 1 ml of it to a new sterile tube. Centrifuge the tube at 8,000 9,000 g for 10 REF R-P1(RG,iQ,Mx)-CE-B / VER 16.12.09 16.05.11 / Page 6 of 12

min. Remove the supernatant leaving 200 μl of the fluid over the pellet. Use tips with aerosol barrier. Resuspend the pellet. 7. WORKING CONDITIONS AmpliSens Toxoplasma gondii-frt PCR kit should be used at 18 25 C. 8. PROTOCOL 8.1. DNA extraction It is recommended that the following nucleic acid extraction kits are used: Extraction kit REF Clinical material for DNA extraction RIBO-prep K2-9-Et-50-CE Whole peripheral and umbilical cord blood White cells of peripheral or umbilical cord blood Cerebrospinal fluid Amniotic fluid DNA-sorb-C K1-6-50-CE Biopsy and autopsy material 8.2. Preparing PCR The total reaction volume is 25 µl, the volume of DNA sample is 10 µl. 8.2.1 Preparing tubes for PCR 1. Prepare the reaction mixture. Per one reaction mixture: - 10 μl of PCR-mix-1-FRT Toxoplasma gondii - 5.0 μl of PCR-mix-2-FRT - 0.5 μl of polymerase (TaqF) Refer to Appendix 1 for calculation of reaction volumes. Take into account that the analysis should include two control points: Positive and Negative Controls of Amplification (C+, NCA, respectively). 2. Prepare the required number of tubes or strips for amplification of DNA from clinical and control samples. 3. Add 15 µl of the prepared reaction mixture to each tube. 4. Using tips with aerosol barrier, add 10 µl of DNA samples obtained from clinical or control samples at the DNA extraction stage. 5. Carry out control amplification reactions: NCA - Add 10 µl of DNA-buffer to the tube for Negative Control of Amplification (NCA). Add 10 µl of Positive Control DNA Toxoplasma gondii and STI to the tube for C+ Positive Control of Amplification (C+). REF R-P1(RG,iQ,Mx)-CE-B / VER 16.12.09 16.05.11 / Page 7 of 12

8.2.2. Amplification Program the real-time instrument according to the manual provided by the manufacturer. AmpliSens-1 amplification program for rotor-type instruments 2 Step Temperature, Fluorescence Time С detection Repeats Hold 95 15 min 1 95 5 s Cycling 60 20 s 5 72 15 s 95 5 s Cycling2 60 20 s FAM/Green, JOE/Yellow 40 72 15 s For settings, see Guidelines. AmpliSens-1 amplification program for plate-type instruments 3 Step Temperature, Fluorescence Time С detection Repeats 1 95 С 15 min 1 95 С 5 s 2 60 С 20 s 5 72 С 15 s 95 С 5 s 3 60 С 30 s FAM, HEX 40 72 С 15 s For settings, see Guidelines. 9. DATA ANALYSIS Toxoplasma gondii DNA amplification product is detected in the JOE/Yellow/HEX channel, Internal Control amplification product is detected in the FAM/Green channel. The results are interpreted by the software of the PCR instrument by the crossing (or not crossing) of the fluorescence curve with the threshold line. See Guidelines and Important Product Information Bulletin for data analysis settings. The analysis results are considered valid, only if the control samples results comply with the following: 2 For example, Rotor-Gene 3000/6000 (Corbett Research, Australia) 3 For example, Cycler iq, iq5 (Bio-Rad, USA); Mx3000P (Stratagene, USA) REF R-P1(RG,iQ,Mx)-CE-B / VER 16.12.09 16.05.11 / Page 8 of 12

Control Stage for control Results for controls FAM/Green Ct in channel JOE/Yellow/HEX Interpretation C- DNA extraction boundary value Neg OK NCA Amplification Neg Neg OK C+ Amplification boundary value boundary value OK *For boundary Ct values, see Important Product Information Bulletin. 1. The sample is considered positive if Ct values detected in the FAM/Green and JOE/Yellow/HEX channel are less than the boundary Ct values for these channels. The fluorescence curve should have a typical sigmoid shape and cross the threshold line in the region of significant fluorescence increase only once. 2. The sample is considered negative if its fluorescence curve does not cross the threshold line (Ct value is absent) and does not have the typical shape. The results of analysis are considered reliable only if the results obtained for Positive and Negative Controls of Amplification as well as for the Negative Control of Extraction are correct. 10. TROUBLESHOOTING Results of analysis are not taken into account in the following cases: 1. If any Ct value appears for the Negative Control of amplification (C ) in the JOE/Yellow/HEX and/or FAM/Green channel, this indicates the contamination of reagents or samples. In this case, the results of analysis of all samples are considered invalid. It is necessary to repeat the analysis of all tests and to take measures to detect and eliminate the source of contamination. 2. If the Ct value is absent for the Positive Control of amplification (C+) in the JOE/Yellow/HEX and/or FAM/Green channel, the results are invalid for all samples. PCR should be repeated for all samples. 3. If Ct values in the FAM/Green channel (IC) are absent in clinical samples, this indicates improper DNA extraction. For these samples, analysis should be repeated starting from the DNA extraction stage. If, for clinical samples, the Ct value detected in the FAM/Green channel exceeds the specified boundary Ct value for IC and the Ct value detected in the JOE/Yellow/HEX channel (Toxoplasma gondii) exceeds the specified boundary Ct value, analysis should be repeated starting from the DNA extraction stage. High Ct values may be due to the loss of DNA during extraction or because of inhibitors. REF R-P1(RG,iQ,Mx)-CE-B / VER 16.12.09 16.05.11 / Page 9 of 12

4. If the Ct value of a clinical sample detected in the JOE/Yellow/HEX channel exceeds the specified boundary Ct value, the result is considered equivocal. It is necessary to repeat the analysis twice. If a positive Ct value is detected twice, the sample is considered as positive. 11. TRANSPORTATION AmpliSens Toxoplasma gondii-frt PCR kit should be transported at 2 8 C for no longer than 5 days. 12. STABILITY AND STORAGE All components of the AmpliSens Toxoplasma gondii-frt PCR kit (except for polymerase (TaqF), PCR-mix-2-FRT, and PCR-mix-1-FRT Toxoplasma gondii) are to be stored at 2 8 C. All components of the AmpliSens Toxoplasma gondii-frt PCR kit are stable until the expiration date on the label. The shelf life of reagents before and after the first use is the same, unless otherwise stated. Polymerase (TaqF), PCR-mix-2-FRT, and PCR-mix-1-FRT Toxoplasma gondii are to be stored at 16 C PCR-mix-1-FRT Toxoplasma gondii is to be kept away from light 13. SPECIFICATIONS 13.1. Sensitivity The analytical sensitivity of AmpliSens Toxoplasma gondii-frt PCR kit is 400 Toxoplasma gondii DNA copies/ml. 13.2. Specificity The claimed analytical features of AmpliSens Toxoplasma gondii-frt PCR kit are guaranteed only when additional reagent kit (RIBO-prep or DNA-sorb-C) is used. The analytical specificity of AmpliSens Toxoplasma gondii-frt PCR kit is ensured by selection of specific primers and probes as well as stringent reaction conditions. The primers and probes were checked for possible homologies to all sequences published in gene banks by sequence comparison analysis. The clinical specificity of AmpliSens Toxoplasma gondii-frt PCR kit was confirmed in laboratory clinical tests. 14. REFERENCES 1. Handbook Sampling, Transportation, and Storage of Clinical Material for PCR Diagnostics, developed by Federal Budget Institution of Science Central Research Institute for Epidemiology, Moscow, 2008. REF R-P1(RG,iQ,Mx)-CE-B / VER 16.12.09 16.05.11 / Page 10 of 12

15. QUALITY CONTROL In compliance with Federal Budget Institution of Science Central Research Institute for Epidemiology ISO 13485-Certified Quality Management System, each lot of AmpliSens Toxoplasma gondii-frt PCR kit has been tested against predetermined specifications to ensure consistent product quality. 16. KEY TO SYMBOLS USED Catalogue number Caution Batch code Sufficient for In vitro diagnostic medical device Expiration Date Version Temperature limitation Consult instructions for use Keep away from sunlight Upper limit of temperature NCA Negative control of amplification Manufacturer C Date of manufacture C+ Negative control of extraction Positive control of amplification Mx For working with Mx3000P or Mx3005P (Stratagene) IC Internal control RG For working with Rotor-Gene 3000/6000 (Corbett Research) iq For work with icycler iq and iq5 (Bio-Rad) REF R-P1(RG,iQ,Mx)-CE-B / VER 16.12.09 16.05.11 / Page 11 of 12

VER 10.06.11 VV List of Changes Made in the Instruction Manual Location of changes Cover page, text Essence of changes The name of Institution was changed to Federal Budget Institution of Science Central Research Institute for Epidemiology REF R-P1(RG,iQ,Mx)-CE-B / VER 16.12.09 16.05.11 / Page 12 of 12