MODEL 300505 INSTALLATION INSTRUCTIONS



Similar documents
Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

SERIES 101 / 105 INSTALLATION INSTRUCTIONS

SUBMERSIBLE PUMP 250 WATTS, WITH FLOAT Model 45014

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

1/3 HP Submersible Sump Pump with Vertical Float Switch

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Battery Backup Sump Pump System

MODEL NO. QWIK JON 100/101/102 SYSTEMS DATE CODE: INSTALLATION INSTRUCTIONS DATE INSTALLED: PREINSTALLATION CHECKLIST

INSTALLATION & OPERATING INSTRUCTIONS

TROUBLESHOOTING GUIDE

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Installation Manual. Model 441 Battery Backup System IMPORTANT: B. *Do not throw away or lose this manual.

Battery Backup Sump Pump System

Battery Backup Sump Pump System

Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages

Water Tec of Tucson Water Systems

A/C-D/C Battery Backup Sump Pump System

accidents which arise due to nonobservance and the safety information herein.

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Safety, Operation and Maintenance Manual with Parts List

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Backup Sump Pump Systems. 1 NEXT

Tri-Homo Style Operation and Maintenance Instructions

Oil and Coolant Circulating Heating System. Model - OCSM

Battery Backup Sump Pump System

SW/SD/VS33 & 50 Submersible Sump/ Effluent Pumps

COMPRESSED AIR DRYER

Battery Backup Sump Pump System

TWO-STAGE CENTRIFUGAL PUMPS

Installation Manual DIAPHRAGM WELL TANK

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

Rules for Safe Operation

Combination Primary and Backup Sump Pump System

QT Residential Blower Metal Residential Blower

Combination Primary and Backup Sump Pump System

LC-50 FOOD WASTE DISPOSER Installation Manual

WGL20, WGL20H, WGL20F Grinder Pumps

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION

Pro Series C11. Combination Primary and Backup Sump Pump System. Instruction Manual & Safety Warnings. Table of Contents

ECOFILTER PUMP VAULT

Jay R. Smith Mfg. Co.

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

GLACIER POOL COOLERS, LLC OPERATOR INSTRUCTIONS, INSTALLATION AND SERVICE MANUAL

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Technical Guide 08/15/14

MAC FAUCETS. Owner s Manual. Models: FA444

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

SUMP PUMP. Sump Pump Backup Systems. City of Ann Arbor B A C K U P O P T I O N S. Does everyone need a backup system?

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

SRA-125/SRAX-125 Double-Rail Lift-Out Rail System Installation & Service Manual with Parts List

Fire Pump Plan Review March 2010

The Company. QUALITY WHICH REDUCES PUMPING COSTS For over 45 years, PAPANTONATOS S.A. has focused on the customer s design,

Geyser-R Heat pump water heater Installation manual

Utility Distribution Systems

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

KLE-115U Single Rack Undercounter Configuration Instruction Manual

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Pump Maintenance - Repair

MAINTENANCE INSTRUCTIONS FOR THE CLEAN-FLO CONTINUOUS LAMINAR FLOW INVERSION / OXYGENATION SYSTEM

The Storm 20-Gallon Wet/Dry Vac

Installation & Operation

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Dehumidifier Users manual. For Models: DH45S DH65S

Compressor Service & Maintenance Manual

OWNER S MANUAL Submersible Sewage Ejector Pumps

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

ATS Overhead Table Shelf System INSTRUCTION MANUAL

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Installation Manual DIAPHRAGM WELL TANK

Installation, operation and maintenance manual

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

STOP M-150S, M-180S. and M-240S Fuel Pump. Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

400W AUTOMATIC STAINLESS STEEL SUBMERSIBLE CLEAN WATER PUMP

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

2 HP / 4 GALLON AIR COMPRESSOR OWNER'S MANUAL

ClearView 100. Instruction Manual

WH/WIH/WIHD/WIHD&M/WIHL AND WIH SERIES

OPERATORS MANUAL FOR Mi-T-M WCL-10S/30S-0M10 CLARIFIER TYPE SOLIDS SEPARATOR

Anthro Tablet Charging Cabinets

BERMAD Fire Protection

ELECTRIC KNIFE SHARPENER

CARING FOR YOUR WATER HEATER

OPERATING & MAINTENANCE AIR COMPRESSOR RANGER 35 INSTRUCTIONS. Part No:

Owner s Manual & Safety Instructions

Water Tec of Tucson Water Systems

Transcription:

WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com Your pump has been carefully packaged at the factory to prevent damage during shipping. However, occasional damage may occur due to rough handling. Carefully inspect your pump for damages that could cause failures. Report any damage to your carrier or your point of purchase. INSTALLATION INSTRUCTIONS MODEL 300505 SUMP PUMP Please read these instructions carefully. Failure to comply to instructions and designed operation of this system, may void the warranty. 2012 BUR-CAM Printed in Canada 300542

SAFETY INSTRUCTIONS: This fine pump that you have just purchased is designed from the latest in material and workmanship. Before installation and operation, we recommend the following procedures: A B C CHECK WITH YOUR LOCAL ELECTRICAL AND PLUMBING CODES TO ENSURE YOU COMPLY WITH THE REGULATIONS. THESE CODES HAVE BEEN DESIGNED WITH YOUR SAFETY IN MIND. BE SURE YOU COMPLY WITH THEM. WE RECOMMEND THAT A SEPARATE CIRCUIT BE LEAD FROM THE HOME ELECTRICAL DISTRIBUTION PANEL PROPERLY PROTECTED WITH A FUSE OR A CIRCUIT BREAKER. WE ALSO RECOMMEND THAT A GROUND FAULT CIRCUIT BE USED. CONSULT A LICENSED ELECTRICIAN FOR ALL WIRING. THE GROUND TERMINAL ON THE THREE PRONG PLUGS SHOULD NEVER BE REMOVED. THEY ARE SUPPLIED AND DESIGNED FOR YOUR PRO- TECTION. D NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DO NOT ONLY UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER PLUG FROM THE RECEPTACLE. Material required for submersible sump pump application Submersible sump pump installation Desired length of 1 1/2 or 1 1/4 of ABS/DWV pipe to link up the pump to the drain line. If needed 1 reducer 1 1/2 to 1 1/4 for a 1 1/4 discharge. 1 only 1 1/4 check valve (350353) (Note that this 1 1/4 check valve may also be use with a 1 1/2 pipe), or 1 only 1 1/2 check valve (350363) (Note that this 1 1/2 check valve may also be use with a 2 pipe). Sump pit or 1 only sump basin. 1 1/4-1 1/2 stainless steel clamps (750886). ABS cement. Tools NOTICE This unit is not designed for applications involving salt water or brine. Use with salt water or brine will void warranty. 2 Screwdrivers, hacksaw to cut pipe, knife to assist in pipe cutting, round file to smooth pipe ends, pipe wrench, adjustable wrench to tighten fittings.

APPLICATION This submersible sump pump is designed for a permanent sump installation. It can be used in light commercial application. and is great for water transfer from flodded areas. CAPACITY: 5 3000 US GPH 10 2600 US GPH 15 2150 US GPH 20 1650 US GPH 25 1000 US GPH FRICTION LOSS IN PIPE NOT INCLUDED FEATURES Cast iron pump body Stainless steel motor body Stainless steel mechanical rotary seal Thermal and overload protection Oil filled motor 1/2HP, 115VAC, 60Hz, 5A, (10A when start) IMPORTANT NOTICE INSTALLATION STEPS Please note before you proceed with the installation of this product that the manufacturer's guideline has to be respected. Failure to comply may void your warranty. The following are minimum requirements in order to protect your residence from flooding. It is a small investment but it is your personal responsibility to protect your home, family and valuables. Failure to comply with the following requirements may also void your warranty: - Two (2) pumps have to be installed in the sump pit. The first pump as a primary pump and the second pump as the backup unit. - Burcam alarm system model 450454 has to be installed to advise you of any malfunctions. - As sump pumps are electrically powered and activated so to prevent flooding, a Burcam battery powered back up pump model 300403 has to be installed to evacuate the water. Pump selection, proper and adequate installation are a must to comply with local by-laws and need to be adhered to. STEP 1 We recommend that you install your pump in a clean location where there is adequate room for servicing at a later date. Protection from freezing temperatures and good ventilation should be considered as well, to provide the pump an environment for long life. Do not use to pump gas or toxic fuels. This submersible sump pump is designed to pump water only. Friction losses in the discharge pipe must be taken into consideration when the horizontal offset is greater than 50 feet. The discharge pipe should be increased from 1 1/2 to 2. This will reduce friction losses and allow the pump to give maximum performance. More friction losses must also be taken into consideration when many elbows and fittings are installed in the discharge line. Each elbows and fittings must be considered as 1 feet of head. The float switch of your pump has been pre-set at the factory and does not need any adjustment. Never run the pump dry. Damage to the seal may occur. Fill pump pit or sump basin with water before turning on the power. STEP 2 Assuming that you have a sump pit located in your basement floor... Your sump pit may be constructed from concrete, brick, tile or more recently a sump basin made from plastic and/or fiberglass. The minimum size of your sump pit should be 18 in diameter and no less than 25 deep. When pit is ready, proceed to next step. 3

STEP 3 STEP 4 STEP 5 STEP 6 STEP 7 STEP 8 SUMP PUMP APPLICATION SEE DIAGRAM ON PAGE 5 At this step, you have the opportunity to install a 1 1/2 or a 1 1/4 discharge. We recommend a 1 1/2 ABS/DWV discharge. Install a check valve (350362 in-line 1 1/2 or 350353 1 1/4 MNPT inlet and 1 1/4 or 1 1/2 outlet) over discharge pipe of your pump and secure it with stainless steel clamps or glued nipple for ABS/DWV pipe. This check valve will allow easy access to pump, should service be required. Install and position your submersible sump pump in the centre of your sump pit or basin and ensure that there is clearance to allow the mechanical float switch a free working area without obstructions (pipe, pit s wall, power cord). The float cord length is factory set and should not need adjustment. If adjustment is required, the switch cord can be shorted or lengthed. Install your discharge pipe from check valve to the point of discharge or drain. For installation over 50 feet of horizontal position discharge pipe, use a 2 pipe to reduce friction loss. The mechanical switch provided with your pump is supplied with a serial electrical male plug. Fix the power cord of the pump into the piggy-back receptacle of the switch and plug this one into electrical grounded outlet. We recommend that a licensed electrician be employed to do wiring. Permanently ground the motor in accordance to the electrical codes for your area. Do not use an extension cord to connect your pump to the power source. From your distribution panel to the receptacle, we recommend a wire gauge not smaller than 14 gauge. Use tape or tie wrap to fix power cords to discharge pipe. Fill the sump pit or basin with water to test the operation of your submersible sump pump. The motor should start when the water level reaches approximetely 3 over your pump. Allow the pump to go through several on-off cycle to assure satisfactory operation. If needed, see trouble shooting guide in this manual. Review your installation with typical diagram. Check all connections for leaks. MAINTENANCE Unplug the switch and pump motor power cord. Remove the pump from pit or basin. Remove trash accumulation and dirt from the pump and float switch. Be sure the float switch operates freely after cleaning. If tar or paint has been received in the pit or basin, use kerosene to remove residue from float switch or pump. Do not use strong paint solvents. Remove the screws that hold the strainer or the base to the bottom of the pump body. Pry the base off the pump body carefully. Clean the impeller and volute passage way from any debris wich may have become in contact with these parts. Again, If tar or paint has entered pump, clean with kerosene. Do not use strong paint solvents. Be sure impeller turns freely after cleaning. Check and clean away any debris wich may be clogging the suction inlet, pump discharge, check valve and discharge line. 4 screws and return sump pump to sump pit or basin and reconnect to piping.

SUMP PUMP APPLICATION STEP 2 Sump pit 18 diameter X 25 depth STEP 3 Prepare your choice of discharge pipe size and check valve STEP 6 Connect float and motor power cable STEP 7 Fill the basin and test the operation STEP 5 Install discharge pipe STEP 8 Review and check connections for leaks STEP 4 Install your pump in centre of pit 35 23 22 21 19 REPAIR PARTS 20 16 17 REF. PART DESCRIPTION REF. PART DESCRIPTION 24 18 15 1 350182 Metal strainer 2 300587 Pump body screws (3) 3 350157 Diffuser 4 350158 Top O ring 5 350159 Impeller 6 350160 Pump housing 7 350167 O ring (2) 8 350163 Lip seal 9 350164 Mechanical seal 10 506032 Lower bearing 11 350166 Motor casing 12 350168 Rotor and shaft 13 350169 Stator 14 350340 Upper ball bearing 15 350173 Motor upper plate 16 350176 Capacitor 17 350177 Upper cover 18 350162 O ring pump body 19 350180 Power cable 20 350136 Screws (5) 21 350181 Handle 22 350137 Screws (6) 23 450704 Capacitor clamp 24 350138 Capacitor clamp screw 25 350139 Nuts (8) 26 350140 Snap rings (4) 27 350183 Long screws (4) 28 350277 Discharge reducer 29 350141 Oil seal 30 350142 Washer 31 350161 Oil chamber cover 32 350143 Key 33 350144 Nut 34 350145 Snap ring 35 450453 Mechanical switch 25 28 32 2 8 33 34 3 5 22 20 1 Repair parts may be ordered from your authorized point of sale or from BUR-CAM PUMPS 26 27 29 30 14 13 12 11 10 9 4 31 6 7 5

TROUBLE SHOOTING GUIDE CHECKLIST NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER CONNECTED. DON T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER FROM THE RECEPTACLE. TROUBLE PROBABLE CAUSE ACTION Motor does not run. Switch is off position Blown fuse Tripped breaker Plug disconnected Corroded plug Low water level Thermal overcharge Defective switch/float Defective motor Improper float position Turn switch to on position Reset Re-install Clean prongs Add water and verify Cool the motor /repair Check movement Pump does not deliver to full capacity. Jammed impeller Plugged check valve Blocked suction/inlet Discharge leak Blocked line/pipe Worn impeller Defective motor Clean Clean/replace Check for debris in pit and clean Repair Check for debris or ice Repair/replace Pump does not shut off. Defective switch Float obstruction Blocked suction/inlet Adjust/check Check for debris in pit and clean TO THE END CONSUMER If you have any problems with the product, before advising the store, where you ve purchased the pump, please contact us at 514 337-4415, and ask for our sales department, and they will be pleased to help you with any questions you might have, concerning your installation. 6