Measuring Sound Insulation using Deconvolution Techniques



Similar documents
Casa da Musica, a new concert hall for Porto, Portugal

Acoustic Terms, Definitions and General Information

Airborne Sound Insulation

Dynamic sound source for simulating the Lombard effect in room acoustic modeling software

Active noise control in practice: transformer station

IMPROVING SOUND DIFFUSION IN A REVERBERATION CHAMBER

Advanced Room Acoustical Measurement Techniques based on Room Impulse Responses

CASE STUDY. Sarakasi Theatre Nairobi, Kenya Room Acoustical Measurements and Modelling. Africa Room Acoustics DIRAC and ODEON

Sound Power Measurement

An Experimental Study of the Sound Insulation Performance and Sound Defect Using Sound Intensity According to the Composition of Balcony Windows

Audio Engineering Society. Convention Paper. Presented at the 129th Convention 2010 November 4 7 San Francisco, CA, USA

MICROPHONE SPECIFICATIONS EXPLAINED

CARMEN R in the Norwich Theatre Royal, UK

SC-30 INTEGRATING SOUND LEVEL METER REAL TIME FREQUENCY ANALYZER

VIPAC ENGINEERS & SCIENTISTS

VIRTUAL SPACE 4D PROJECT: THE ROOM ACOUSTICAL TOOL. J. Keränen, P. Larm, V. Hongisto

Antennas & Propagation. CS 6710 Spring 2010 Rajmohan Rajaraman

Acoustics of indoor sports halls and gymnasia

The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings. Focus on the IBDN System 4800LX from NORDX/CDT

AN-007 APPLICATION NOTE MEASURING MAXIMUM SUBWOOFER OUTPUT ACCORDING ANSI/CEA-2010 STANDARD INTRODUCTION CEA-2010 (ANSI) TEST PROCEDURE

Noise Design Advice. Noise can be a major factor to consider in any new development.

Noise. CIH Review PDC March 2012

Building Design for Advanced Technology Instruments Sensitive to Acoustical Noise

Characterization of acoustics in open offices - four case studies

The Role of Acoustics in Curtain Wall Design:

Acoustic analysis by computer simulation for building restoration

STANDARD DEVIATIONS IN FIELD MEASUREMENTS OF IMPACT SOUND INSULATION. Mikko Kylliäinen

Acoustical Design for Concert Hall in the Science and Art Centre of Xiamen University

HD Radio FM Transmission System Specifications Rev. F August 24, 2011

What Audio Engineers Should Know About Human Sound Perception. Part 2. Binaural Effects and Spatial Hearing

Estimation of Loudness by Zwicker's Method

TCOM 370 NOTES 99-4 BANDWIDTH, FREQUENCY RESPONSE, AND CAPACITY OF COMMUNICATION LINKS

CBS RECORDS PROFESSIONAL SERIES CBS RECORDS CD-1 STANDARD TEST DISC

GSM frequency planning

Voltage. Oscillator. Voltage. Oscillator

The influence of Wi-Fi on the operation of Bluetooth based wireless sensor networks in the Internet of Things

Effects of Different Diffuser Types on the Diffusivity in Reverberation Chambers

A simple method to compute aircraft noise inside dwellings

Inter-Cell Interference Coordination (ICIC) Technology

is the power reference: Specifically, power in db is represented by the following equation, where P0 P db = 10 log 10

Dynamic Frequency Selection (DFS) and the 5GHz Unlicensed Band

Lightweight Partition Design for Residential and Commercial Buildings

Sound Pressure Measurement

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

A METHOD FOR THE ASSESSMENT OF SOUNDS AS PERCEIVED SEPARATELY FROM THEIR BACKGROUND

DeNoiser Plug-In. for USER S MANUAL

Investigation of sound insulation for a Supply Air Window field measurements and occupant response

Manual Analysis Software AFD 1201

Acoustics of the Teatro Arcimboldi in Milano. Part 2: Scale model studies, final results

Propagation Channel Emulator ECP_V3

EE4367 Telecom. Switching & Transmission. Prof. Murat Torlak

A Sound Localization Algorithm for Use in Unmanned Vehicles

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: T-DR1 Teutonic Outswing Vinyl Entrance Door

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: T-DR2 Teutonic Outswing Vinyl Entrance Door

Linear Parameter Measurement (LPM)

Design of an Acoustic Anechoic Chamber for Application in Hearing Aid Research

APPLYING VIRTUAL SOUND BARRIER AT A ROOM OPENING FOR TRANSFORMER NOISE CONTROL

Façade acoustic design strategy Proposed residential development Irvin Avenue, Saltburn

Voice Communication Package v7.0 of front-end voice processing software technologies General description and technical specification

ASTM E 90: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements

Laboratory Guide. Anatomy and Physiology

Lecture 1-6: Noise and Filters

Testing of Partial Discharges in Generator Coil Bars with the Help of Calibrated Acoustic Emission Method

Probability and Random Variables. Generation of random variables (r.v.)

Workshop Perceptual Effects of Filtering and Masking Introduction to Filtering and Masking

Difference in levels of groundborne noise and vibrations between the T-1300 and MX-3000 metro trains in Oslo

Absorption Coefficients and Impedance Daniel A. Russell Science and Mathematics Department, Kettering University, Flint, MI, 48504

Relationship between Sound Pressure and Sound Power Levels

Testing Panasonic s WM-61A Mike Cartridge

Figure1. Acoustic feedback in packet based video conferencing system

PHYS 331: Junior Physics Laboratory I Notes on Noise Reduction

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: TUBELITE, INC. SERIES/MODEL: T TYPE: Two-Lite Storefront

Building Technology and Architectural Design. Program 4th lecture Case studies Room Acoustics Case studies Room Acoustics

RANDOM VIBRATION AN OVERVIEW by Barry Controls, Hopkinton, MA

Exhaust noise control case study for 2800 class locomotive

PERCENTAGE ARTICULATION LOSS OF CONSONANTS IN THE ELEMENTARY SCHOOL CLASSROOMS

DESIGN CRITERIA FOR ACOUSTIC ENHANCEMENT SYSTEMS Ben Kok, Wim Prinssen Systems for Improved Acoustic Performance Uden, The Netherlands

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MGM INDUSTRIES SERIES/MODEL: TYPE: Single Hung Window

Direct and Reflected: Understanding the Truth with Y-S 3

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

COMPARISON OF METHODOLOGIES FOR CONTINU- OUS NOISE MONITORING AND AIRCRAFT DETECTION IN THE VICINITY OF AIRPORTS

Wireless LAN Concepts

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS. drm TesT equipment

Room Acoustic Reproduction by Spatial Room Response

Enhancing the SNR of the Fiber Optic Rotation Sensor using the LMS Algorithm

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

Tuning Subwoofers - Calibrating Subwoofers

Aircraft cabin noise synthesis for noise subjective analysis

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Propsim enabled Mobile Ad-hoc Network Testing

Functional Communication for Soft or Inaudible Voices: A New Paradigm

Schindler 3300 / Schindler 5300 Information on noise and vibration.

Audio processing and ALC in the FT-897D

Four Wave Mixing in Closely Spaced DWDM Optical Channels

Electronic Communications Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT)

DAAD: A New Software for Architectural Acoustic Design

Noise associated with the ground water systems serving residential geothermal heat pumps

Sound absorption and acoustic surface impedance

Transcription:

Measuring Sound Insulation using Deconvolution Techniques C. C. J. M. Hak a, N. H. A. M. Van Hout b and H. J. Martin c a Technische Universteit Eindhoven, De Rondom 10, 5612 AP Eindhoven, Netherlands b LeVel Acoustics BV, De Rondom 10, 5612 AP Eindhoven, Netherlands c Eindhoven University of Technology, Den Dolech 2, BWK/BPS, 5600 MB Eindhoven, Netherlands c.hak@inter.nl.net 3991

To compare the acoustic performance of a building element with given sound insulation requirements, measurements need to be done. Generally, a broadband noise source is used according to international standards. This method does not always work in practice due to high sound insulation values or high background noise levels. It is very inconvenient from a practical point of view or even impossible to perform an accurate sound insulation measurement for all frequency bands. A solution to this problem can be found in deconvolution techniques using MLS or sweep signals. It is possible to increase the signal to noise ratio with these techniques by averaging measurements and spreading out the spectral sound energy in time. As a result an efficient use of available sound power is possible. In a laboratory the use of MLS or sweep signals as a source signal and deconvolution as a measurement technique to obtain the sound insulation under noisy conditions was investigated. 1 Introduction ISO 140-4 [1] describes the procedure for measuring the sound insulation of a practical construction using broadband noise. In addition to this traditional technique deconvolution techniques can be used to determine the sound insulation of a construction. The deconvolution technique makes use of a well-defined signal like MLS or swept-sine and is described in ISO 18233 [3]. Unlike using the traditional technique, the signal-to-noise-ratio (SNR) can effectively be increased by increasing the measurement time using the deconvolution technique. A disadvantage of the deconvolution technique is the sensitivity to time-variance, which may reduce the effective SNR. This holds less for a swept-sine than for an MLS signal. Another advantage of a swept-sine is the higher obtainable sound pressure level using the same power amplifier. According to ISO 140-4 for a traditional sound insulation measurement in the field, a correction for background noise has to be applied if in the receiving room the difference between the total level of transmitted sound and background noise and the level of background noise only (L (S+N) - L N ) is 6 db or more. At a difference of 10 db or more, correction is not required. According to ISO 18233 the sound reduction D [Eq.(1)] obtained from an impulse response measurement is reliable if the decay range or INR [9] is at least 30 db, (i.e. the background noise is negligible). Is the measurement result still usable if this requirement is not met? In other words, is it possible to eliminate the background noise from the measured signal? And what is the impact of fluctuating background noise? It was investigated whether it is possible to correct the measured signal from the receiving room for background noise using deconvolution techniques according to ISO 18233, under normal room conditions and within the boundaries of ISO 140-4. For this investigation two transmission rooms in the laboratory of the Eindhoven University of Technology were used to simulate a practical situation indoors. An extra loudspeaker was used to simulate background noise (random white noise and traffic sound). The starting point for the measurements was an SNR of 0 db. During the investigation, the following parameters were varied: Type of test signal (MLS versus swept-sine) Type of background noise (random white noise versus traffic noise) Measurement time and averaging (averaging 8 sequences of 10,9 s versus one long measurement of 87,9 s) All results were compared with the results of traditional measurements carried out under the same measurement and room conditions, without background noise (SNR >30 db). 2 Background The sound reduction D between two rooms can be written as: where: D = (1) L1 L2 [ db] L 1 = the energy averaged sound pressure level in the source room [db] L 2 = the energy averaged sound pressure level in the receiving room [db] A system impulse response h is obtained from its response y to an excitation signal s through deconvolution: h = (2) y s Using this technique according to ISO-18233: 2 h1 ( t) dt 0 D = L1 L2 = 10lg [ db] 2 h2 ( t) dt 0 (3) 3992

where: h 1 2 (t) = the squared impulse response in the source room h 2 2 (t) = the squared impulse response in the receiving room The measured sound pressure level in the receiving room will be higher due to background noise. The value of D could therefore be seriously underestimated at low SNR values. As mentioned before, ISO 140-4 describes how to correct for this effect. 3 Measurements 3.1 Procedure The measurements were carried out in two transmission rooms of the Eindhoven University of Technology. Transmission room 1, which is a reverberant room (T 60avg 5 s), was used as the source room. Transmission room 2 was used as the receiving room. To simulate a practical situation, the receiving room was semi-anechoic (T 60avg 1 s). Between the rooms a double layered glass construction was placed. All sound reduction measurements were done according to ISO 140-4, which describes the procedure for measuring the sound insulation of a construction in the field. According to this standard at least two source positions and 5 receiving positions (in the source room as well as receiving room) have to be used. For practical reasons the sound pressure level was measured in both rooms at 6 positions. Two channels were used to record the sound pressure levels in the source and receiving room simultaneously. The mean sound pressure level was determined by averaging over the 6 measurement positions. The sound reduction between the two transmission rooms was measured with and without background noise by using the traditional and deconvolution method. For the measurements with background noise, noise was generated by a loudspeaker in the receiving room. Two types of background noise were used: white noise and traffic noise. The spectrum of the simulated background noise was shaped so as to obtain an SNR between -0.5 and 0.5 db in each 1/3 octave band. With background noise the SNR in the receiving room was 0 db. Using the deconvolution technique, the SNR was effectively increased from 0 to 9 db by averaging and increasing the measurement time. The results of all measurements were normalised to D 0, where D 0 is defined as the average over the D values determined from the traditional, MLS and swept-sine measurements without background noise. 3.2 Equipment Figure 1 Measurement setup. The measurement equipment consisted of the following components: signals: random white noise, MLS and 87.4 s, lin swept-sine and 87.4 s, traffic noise (urban motor way) 180 s; input/output: USB audio device 1 (Acoustics Engineering - Triton); power amplifier: (Acoustics Engineering - Amphion); sound sources: omnidirectional (B&K Type 4292); microphones: ½ omnidirectional (B&K Type 4165); software: DIRAC 4.0 (B&K/Acoustics Engineering Type 7841). 3.3 Measurements Source signal Signal length Random noise (traditional) MLS Swept-sine (lineair) No noise SNR >30 db Background noise White noise SNR = 0 db Traffic noise SNR = 0 db --- 8x (avg) 8x (avg) 8x (avg) 8x (avg) Table 1 Used measurement signals, measurement lengths, types of background noise and SNR values. The measurements were carried out over four days, all under the same room conditions (temperature: 20 ±1 o C, relative humidity: 46 ± 2 %), using the same measurement setup and measurement equipment. For every measurement session the spectrum of the background noise was reshaped as described in paragraph 3.1. 3993

4 Results Figure 2 depicts the spread in the results from the used methods without background noise. Starting point is the equality of the different techniques without background noise [7,8]. - - - - - Without background noise: Traditional MLS Sweep Figure 2 Normalised level difference D obtained from the traditional, MLS and swept-sine measurements, all without background noise: INR min > 50 db. Figure 3 shows the normalised level differences D for all measurements. The results were all corrected for the background noise, i.e. raised by approximately 3 db at the 0 db SNR. - - - - - MLS single 10.9 noise Sweep single 10.9 noise MLS single 10.9 traffic Sweep single 10.9 traffic Traditional 10.9 noise Figure 3 Same as figure 2, but for various source and background signals. Source signal length =. Figure 4 shows the same results, but with 8 times longer measurement times, hence 9 db higher effective SNR values. In this case the background noise correction of the results was reduced to approximately 0.5 db. - - - - - MLS avg noise MLS avg traffic Sweep avg noise Sweep avg traffic MLS long noise MLS long traffic Sweep long noise Sweep long traffic Figure 4 Same as figure 3, but for source signal lengths of and 8x (avg). From figures 3 and 4 it is clear that the spread in D is reduced by the increased measurement time, as expected. In addition, figure 4 shows little difference between averaged and long source signals, except for the sweep with traffic noise. While the averaged sweep shows the smallest spread in D, the long sweep seems to be affected around 250 Hz, which indeed is the band containing the most energy of the traffic noise used. This difference is explained as follows. During the section containing 250 Hz a sweep can be disturbed by traffic noise. In case of multiple sweeps, the impact of this effect is reduced by the undisturbed periods, while a single long sweep will always be affected. For the sake of completeness, figure 5 shows the same results as figure 4 but in full octave bands. - - - - - MLS avg noise MLS avg traffic Sweep avg noise Sweep avg traffic MLS long noise MLS long traffic Sweep long noise Sweep long traffic Figure 5 Same as figure 4, but measured in full octave bands. In practice, the sound reduction often is expressed by single number quantities. Table 2 shows the maximum measured error of the level difference at several bandwidths. 3994

Maximum level difference measurement error at several used bandwidths 1/3 octave 1/1 octave 2 octaves 6 octaves +/- 0.5 db * +/- 0.4 db +/- 0.3 db +/- 0.2 db * -1 db for 100 and 125 Hz Table 2 Maximum error in normalised level differences from measurements using deconvolution techniques. 5 Conclusions 1. Without background noise, the spread in D (measured over several days) of the different measurement techniques stays below 0.2 db for nearly all third octave bands. This spread equals the spread in D of measurements carried out in a short measurement period, with only one measurement technique and under laboratory conditions. 2. With background noise resulting in SNR = 0 db, the spread in D increases by a comparable amount over all deconvolution methods, background noise types and types of measurement time increase, staying below 0.5 db when measuring time is increased by a factor of 8. 3. D values from averaged signals and from long signals compare very well (within 0.1 db), except for sweeps with traffic noise. 4. Long sweeps are affected more by traffic noise than averaged short sweeps. 5. With background noise, the D values from the various methods compare better as the bandwidth considered increases. The differences decrease down to 0.2 db when averaged spectrally over 6 octaves. References [1] ISO 140-4, Acoustics - Measurements of sound insulation in buildings and of buildings elements, part 4: Field measurements of airborne sound insulation of building elements, (1998) [2] M.R. Schroeder, Integrated-impulse method for measuring sound decay without using impulses, Journal of the Acoustical Society of America 66, 497-500 (1979) [3] ISO 18233, Acoustics - Application of new measurement methods in building and room acoustics, (2006) [4] D.D. Rife, J. Vanderkooy, Transfer-function measurements with maximum length sequences, Journal of the Audio Engineering Society 37, 419-444, (1989) [5] S. Müller, P. Massarani, Transfer-function measurements with sweeps, Journal of the Audio Engineering Society 49, 443-471, (2001) [6] F. Satoh, J. Hirano, S. Sakamoto, H. Tachibana, Sound propagation measurement using swept-sine signal, Proc. Inter-Noise (2005) [7] P. Bonfiglio, P. Fausti, Determination of Sound Reduction Index by impulse response measurements, Proc. Acustica (2004) [8] H.J. Martin, International Round Robin on two types of glazing concerning accuracy of laboratory sound insulation measurements, Results of TU/e Acoustics Lab., Eindhoven University of Technology Fac. of Architecture, Building and Planning, Unit BPS, (2007) [9] C.C.J.M. Hak, J.P.M. Hak, R.H.C. Wenmaekers, INR as an Estimator for the Decay Range of Room Acoustic Impulse Responses, AES Convention Amsterdam (2008) [10] C.C.J.M.Hak, J.S.Vertegaal, MP3 Stimuli in Room Acoustics, International Congress on Acoustics Madrid (2007) [11] C.C.J.M.Hak, J.P.M.Hak, Effect of Stimulus Speed Error on Measured Room Acoustic Parameters, International Congress on Acoustics Madrid (2007) 3995