TECHNICAL DATA. 2. LISTINGS AND APPROVALS See Tables 1 & 2.



Similar documents
Industrial Electric Monitors. Industrial

HYDROSTATIC TEST PUMPS

TECHNICAL DATA. 30a. September 18, /4-8 (DN32 - DN200)

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

MONITOR SECTION INDEX

Industrial Monitors. Weight lbs. (Kg) Style. 55* (24.9 kg) 14"** (356 mm) * Less nozzle ** Less handle. Weight lbs. (kg) Style / 16"** (538 mm)

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Quick response concealed horizontal sidewall sprinkler

TECHNICAL DATA 2. LISTINGS AND APPROVALS. Spray Nozzle 11. December 20, 2013

Automatic Fire Fighting Monitors

HIGH VELOCITY WATER SPRAY NOZZLE

ESFR DRY PENDENT SPRINKLER VK502 (K14.0) TECHNICAL DATA

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Type D3 PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

TECHNICAL DATA. Dry 122a. November 12, 2013

AIR OPERATED OIL PUMPS AND KITS

1300 MAXTRAK SPECIFICATION

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

HELI-DECKS & HELI-PORTS

Series TY-FRB 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick and Standard Response (Light Hazard) General Description

FOAM CHAMBER MODEL - FC

FAIRBANKS NIJHUIS FIRE PUMPS.

esfr pendent sprinkler vk510 (k25.2)

ISO 9001 Certified Manufacturing Facility SPECIFICATIONS

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

Automatic Fire Sprinkler Submittal Requirements

Design & Construction Standards, Revised January

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

Model/Sprinkler Identification Numbers

Flygt Ball Check Valves

BERMAD Fire Protection

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Operating, Installation, and Maintenance Instructions

Product catalogue, pipe and sewer cleaning systems

SUPERYACHT SPARES. Nozzles and portable monitors. / info@superyachtspares.com /

The conditions below apply to the curves shown on the following pages.

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Air Eliminators and Combination Air Eliminators Strainers

1-1/2 Inch (DN40) 9 lbs. (4,1 Kg) 8 lbs. (3,6 Kg) Flange Groove* N/A N/A. Flange Flange N/A N/A

08.08 Vic-Check Valves

Used Fluid Handling Portable Used-Oil Gravity Drains

Para la protecció n de la vida y las propiedades, las Bombas de Incendio AC ofrece paquetizados que satisfacen cada necesidad.

Extended Coverage Sprinklers

RESIDENTIAL SPRINKLER INSTALLATION GUIDE

[ means: Save time, money and space! MAXXMILL 500. Vertical milling center for 5-side machining

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

API Flanged Safety Relief Valves Series 526 CATALOG

TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL

Nordson Automatic Spray Gun Support Kits

Nozzle Check Valves. NOREVA nozzle check valves are used

Fixed or Semi-Fixed Fire Protection Systems for Storage Tanks

TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL

THE ONLY CRANE WITH 10 HYDRAULIC EXTENSIONS. New Model Presentation - VR85

BLADDER SURGE CONTROL SYSTEM

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Fire Pump Plan Review March 2010

Technical Data. Installation

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

Suction assembly for l IBC and 205 l drums mm suction tube Suction assembly for tanks mm suction tube.

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Vertical Pumps for the Oil & Gas Industry

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

TRUCK MOUNTED KNUCKLE BOOM HYDRAULIC CRANE PROPOSAL

Installation, Maintenance, & Repair Series 4000B/LF4000B

Series DS-1 Dry-Type Sprinklers 5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description

Model RV-1 Pressure Relief Valve 2 to 8 Inch (DN50 to DN200), 250 psi (17,2 bar) Pilot-Operated, Globe and Angle Body Styles General Description

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Carton - Straight Link Machine Chain (Order Unit is Feet )

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Pipe Cutting and Beveling Clamshells

Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.

Foam Systems Inductors & Proportioners

NITROUS TRANSFER PUMP INSTRUCTIONS

Goulds Water Technology

Model 1210C Battery Powered Pump Shown. Description

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

CHAPTER. Standpipes and Hose Systems OVERVIEW. Standpipe and Hose Systems Defined

123 Industrial Loop Road Paynesville, MN Phone:

AKRON BRASS COMPANY PH ( ) FAX ( )

Stainless Steel Valves For the Sanitary Industries

BERMAD Fire Protection

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

C I T Y O F S E L M A F I R E D E P A R T M E N T

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps

Transcription:

May 3, 2013 Foam 138a 1. DESCRIPTION Chemguard Water Powered Oscillating Monitors are designed to automatically discharge over a specific design area upon system activation. These are suitable for use in high risk areas such as tank farm facilities, aircraft hangars, offshore, refineries, chemical plants, and heliports. Features The monitor and body of the oscillating unit are manufactured of brass. The water drive wheel is bronze with bronze supply gate valve. CWPOM is UL Listed with CMNB350, CMNB500 and CMNB750 monitor nozzles only Capable of flowing foam or water Unique water drive wheel design Arc of oscillation adjustable via 6 set points Speed of oscillation adjustable from 0-30 /sec. (24 / sec. @100 psi) (7 Bar) Manual override capabilities in both horizontal and vertical degree fields Minimum operating pressure 40 psi (2.8 Bar) Maximum operating pressure 200 psi (14 Bar) Flow of water / foam solution through water drive wheel: - At 50 psi (3.5 Bar) 5 gpm (19 lpm) At 100 psi (7 Bar) 8 gpm (30 lpm) - Double reduction oil bath gearbox Grease fittings and two rows of stainless steel ball bearings at all rotation joints on monitor All brass and stainless steel construction Monitor has one tiller bar control for manual control Unit equipped with a garden hose test connection. This allows functional check of the oscillation mechanism without system flow. 2. LISTINGS AND APPROVALS See Tables 1 & 2. 3. Technical data Specifications: See Tables 1 & 2. Material Standards: See Table 1. Ordering Information: See Table 2. Viking Technical Data may be found on The Viking Corporation s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. 4. Installation The vertical angle of elevation and horizontal arc of oscillation is field adjustable and can be set and locked in position. The monitor can be set to oscillate over a range of 0-120 and the oscillation arc can be set anywhere within the 360 field of operation. Elevation range of the unit is between +80 and -40 from the horizontal plane. 5. Operation A water drive wheel connected to a double reduction gearbox drives the oscillating mechanism. To operate the drive wheel, a small quantity of flow is diverted from the monitor inlet. The monitor requires no external wiring or hydraulic control for operation. The drive wheel design is unique in that it does not require an inlet filter. This makes the oscillating mechanism highly reliable and less likely to fail. 6. Inspections, tests and maintenance NOTICE: The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to recognized standards such as those produced by NFPA, LPC, and VdS which describe care and maintenance of sprinkler systems. In addition, the Authority Having Jurisdiction may have additional maintenance, testing and inspection requirements which must be followed. WARNING: Any system maintenance or testing which involves placing a control valve or detection system out of service may eliminate the Fire Protection of that system. Prior to proceeding, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a Fire Patrol in the affected area. Form No. F_051008 Replaces page 138a-e, dated March 28, 2013. (Removed Part Number F15316.)

Foam 138b May 3, 2013 7. Availability Viking Foam Products are available through a network of domestic and international distributors. See the Viking web site for closest distributor or contact The Viking Corporation. 8. guarantee For details of warranty, refer to Viking s current list price schedule or contact Viking directly. Part No. Inlet Diameter 1 Table 1: Oscillating Monitor Base Specifications Discharge Diameter 2 Waterway Diameter F15048 4 4 2-1/2 3 (76 mm) F15049 5 4 3-1/2 4 (100 mm) Maximum Flow 3 Weight Material 1250 GPM (4740 LPM) 2000 GPM (7570 LPM) 1 Monitor inlets are ANSI Class 150 Flat Face flanges. 2 Monitor discharges are male NST Threads. 3 Flow ratings are given for 100 psi (7 bar). Maximum operating pressure is 200 psi (14 bar). 4 Used in assemblies with flow up to and including 1250 GPM. 5 Used in assemblies with flow between 1300 and 2000 GPM. 120 lbs. (54 kg) Brass and Stainless Steel 150 lbs. (68 kg) Brass and Stainless Steel

May 3, 2013 Foam 138c Figure 1: Dimensions Part Number A B C D E F G F15048 13 (33 mm) 17 (43 mm) 8 (20 mm) 3 (8 mm) 11 (28 mm) 23 (58 mm) 14 (36 mm) F15049 14.5 (37 mm) 18.8 (48 mm) 8 (20 mm) 3 (8 mm) 11 (28 mm) 23 (58 mm) 14 (36 mm)

Foam 138d May 3, 2013 Figure 2: Pressure Loss vs. Flow F15048 Monitor Figure 3: Pressure Loss vs. Flow F15049 Monitor

May 3, 2013 Foam 138e Table 2: Assembly Specifications Monitor Inlet Pressure Viking Part Number Includes Base (See Table 1) Chemguard Model Number Listings Flow Rate Monitor Elevation Angle 50 psi (3.45 bar) 100 psi (6.9 bar) 150 psi (10.3 bar) Fixed Oscillating Fixed Oscillating Fixed Oscillating Reach Height Reach Height Reach Height Reach Height Reach Height Reach Height F15050 F15051 F15052 F15048 CWPOM-350 CWPOM-500 CWPOM-750 UL Listed* UL Listed* UL Listed* 350 GPM (1325 LPM) 500 GPM (1893 LPM) 750 GPM (2839 LPM) 5 60 ft. 8 ft. 15 90 ft. 15 ft. 55 ft. 80 ft. 8 ft. 14 ft. 1 135 ft. 30 100 ft. 25 ft. 90 ft. 145 ft. 20 ft. 100 ft. 125 ft. 9 ft. 18 ft. 32 ft. 135 ft. 30 ft. 135 ft. 170 ft. 175 ft. 12 ft. 39 ft. 5 65 ft. 9 ft. 60 ft. 9 ft. 115 ft. 105 ft. 9 ft. 150 ft. 13 ft. 15 95 ft. 30 105 ft. 5 70 ft. 15 98 ft. 30 115 ft. * UL LIsted with Chemguard C301 MS (Viking Part Number F14971) 16 ft. 26 ft. 16 ft. 28 ft. 85 ft. 95 ft. 65 ft. 88 ft. 98 ft. 15 ft. 24 ft. 16 ft. 25 ft. 155 ft. 165 ft. 120 ft. 155 ft. 170 ft. 36 ft. 11 ft. 36 ft. 145 ft. 150 ft. 105 ft. 146 ft. 150 ft. 21 ft. 33 ft. 11 ft. 21 ft. 33 ft. 185 ft. 200 ft. 160 ft. 185 ft. 2 25 ft. 44 ft. 14 ft. 25 ft. 45 ft. 120 ft. 150 ft. 155 ft. 135 ft. 165 ft. 180 ft. 140 ft. 168 ft. 183 ft. 21 ft. 35 ft. 11 ft. 40 ft. 13 ft. 42 ft.

This page intentionally left blank Form No. F_051008 Replaces page 138a-e, dated March 28, 2013. (Removed Part Number F15316.)