FlexArray Virtualization



Similar documents
FlexArray Virtualization

Fibre Channel and iscsi Configuration Guide

High Availability and MetroCluster Configuration Guide For 7-Mode

Windows Host Utilities Installation and Setup Guide

V-Series Systems Implementation Guide for EMC CLARiiON Storage

The IntelliMagic White Paper: SMI-S for Data Collection of Storage Performance Metrics. December 2010

Windows Host Utilities 6.0 Installation and Setup Guide

Implementing Storage Concentrator FailOver Clusters

SAN Conceptual and Design Basics

Hardware and Software Interoperability Matrix

E-Series. NetApp E-Series Storage Systems Mirroring Feature Guide. NetApp, Inc. 495 East Java Drive Sunnyvale, CA U.S.

EMC ViPR Controller. User Interface Virtual Data Center Configuration Guide. Version REV 01

Hardware Compatibility List

Data ONTAP DSM 4.1 For Windows MPIO

EMC ViPR Controller. ViPR Controller REST API Virtual Data Center Configuration Guide. Version

Using VMware ESX Server with IBM System Storage SAN Volume Controller ESX Server 3.0.2

SAN Implementation Course SANIW; 3 Days, Instructor-led

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-

IMPROVING VMWARE DISASTER RECOVERY WITH EMC RECOVERPOINT Applied Technology

N_Port ID Virtualization

Vicom Storage Virtualization Engine. Simple, scalable, cost-effective storage virtualization for the enterprise

Clustered Data ONTAP 8.3

Software Storage Platform Mixing Rules

IBM TotalStorage SAN Volume Controller. Configuration. Version SC

Setup for Failover Clustering and Microsoft Cluster Service

Setup for Failover Clustering and Microsoft Cluster Service

Simple virtualization IBM SAN Volume Controller (SVC)

EMC PowerPath Family

HBA Virtualization Technologies for Windows OS Environments

WHITEPAPER: Understanding Pillar Axiom Data Protection Options

Data Migration Service for isr6200

IMPLEMENTING EMC FEDERATED LIVE MIGRATION WITH MICROSOFT WINDOWS SERVER FAILOVER CLUSTERING SUPPORT

Storage Capacity Optimization. Reduce storage costs with Sentry Software and BCO Bertrand Martin Sentry Software

AX4 5 Series Software Overview

SANtricity Storage Manager 11.25

Fibre Channel SAN Configuration Guide ESX Server 3.5, ESX Server 3i version 3.5 VirtualCenter 2.5

EMC FEDERATED TIERED STORAGE (FTS) Allows Seamless Integration Between EMC Symmetrix VMAX Series and Third-Party Storage Arrays

Violin Memory Arrays With IBM System Storage SAN Volume Control

HiCommand Dynamic Link Manager (HDLM) for Windows Systems User s Guide

EMC CLARiiON Asymmetric Active/Active Feature

IP SAN Fundamentals: An Introduction to IP SANs and iscsi

How To Use A Virtualization Server With A Sony Memory On A Node On A Virtual Machine On A Microsoft Vpx Vx/Esxi On A Server On A Linux Vx-X86 On A Hyperconverged Powerpoint

Direct Attached Storage

Frequently Asked Questions: EMC UnityVSA

EMC Invista: The Easy to Use Storage Manager

Fibre Channel and iscsi Configuration Guide

IBM Tivoli Storage Productivity Center (TPC)

OnCommand Insight 6.4

HP 3PAR Windows Server 2012 and Windows Server 2008 Implementation Guide

Configuration Rules and Examples for FAS20xx Systems

How To Use The Cisco Mds F Bladecenter Switch For Ibi Bladecenter (Ibi) For Aaa2 (Ibib) With A 4G) And 4G (Ibb) Network (Ibm) For Anaa

EMC Symmetrix with Microsoft Windows Server 2003 and 2008

Enterprise Storage Network Management

Continuous Availability for Business-Critical Data. MetroCluster Technical Overview

FUJITSU Storage ETERNUS Multipath Driver (Windows Version) Installation Information

Continuous Availability for Business-Critical Data

How To Use Visualsan On A Server With A Memory Card (For A Non-Procedure)

NetApp Storage System Plug-In for Oracle Enterprise Manager 12c Installation and Administration Guide

EMC Solutions for Disaster Recovery

Setup for Failover Clustering and Microsoft Cluster Service

Data ONTAP 8.2. MultiStore Management Guide For 7-Mode. NetApp, Inc. 495 East Java Drive Sunnyvale, CA U.S.

SANtricity Storage Manager 11.20

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-

OnCommand Unified Manager

P4000 SAN/iQ software upgrade user guide

EMC VPLEX: LEVERAGING ARRAY BASED AND NATIVE COPY TECHNOLOGIES

Linux Host Utilities 6.1 Installation and Setup Guide

Storage Pool Management Feature in EMC Virtual Storage Integrator

Setup for Failover Clustering and Microsoft Cluster Service

Customer Education Services Course Overview

The HBAs tested in this report are the Brocade 825 and the Emulex LPe12002 and LPe12000.

SanDisk ION Accelerator High Availability

Clustered Data ONTAP 8.3

Best in Class Storage Solutions for BS2000/OSD

VMware Site Recovery Manager with EMC RecoverPoint

Clustered Data ONTAP 8.3

HP Serviceguard for Linux Certification Matrix

Monitoring FibreCAT CX systems with ServerView Operations Manager

EMC Virtual Infrastructure for SAP Enabled by EMC Symmetrix with Auto-provisioning Groups, Symmetrix Management Console, and VMware vcenter Converter

EMC Connectrix Manager Software

The Benefit of Migrating from 4Gb to 8Gb Fibre Channel

EMC VNX Series Release 7.0

Clustered Data ONTAP 8.3

Configuration Maximums

Setup for Failover Clustering and Microsoft Cluster Service

Clustered Data ONTAP 8.3

: HP HP0-X02. : Designing & Implementing HP Enterprise Backup Solutions. Version : R6.1

Netapp Interoperability Matrix

1. Revision Page Revision Page 1

OnCommand Unified Manager 6.2

OnCommand Performance Manager 1.1

QLogic 3810, QLogic 5000 Series, and QLogic 5800V Series Switch Firmware. Version Table of Contents

HP XP P9000 External Storage for Open and Mainframe Systems User Guide

SAN Backup Best Practices

HP StorageWorks MPX200 Simplified Cost-Effective Virtualization Deployment

June Veritas TM Operations Manager 6.0 Hardware and Software Compatibility List

HP Virtual Connect Ethernet Cookbook: Single and Multi Enclosure Domain (Stacked) Scenarios

Transcription:

Updated for 8.2.1 FlexArray Virtualization Implementation Guide for Third-Party Storage NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277 Web: www.netapp.com Feedback: doccomments@netapp.com Part number: 215-08542_C0 December 2014

Table of Contents 3 Contents How this guide fits into your implementation planning... 6 Where to find interoperability and limits information for configurations with storage arrays... 8 Interoperability information about support for storage arrays... 8 Limits information for configurations with storage arrays... 9 Use of storage array advanced features... 10 Data ONTAP systems that can use array LUNs on storage arrays... 11 General configuration guidelines for all storage arrays... 12 Requirement for 8-Gb array port initialization... 12 EMC CLARiiON and VNX storage arrays... 13 Required parameters for EMC CLARiiON and VNX storage arrays with Data ONTAP systems... 13 General configuration guidelines... 13 How EMC CLARiiON and VNX storage arrays control access to data... 13 Limitation on array LUN numbering with EMC CLARiiON and VNX arrays... 14 Guidelines for enabling ALUA on EMC CLARiiON and VNX storage arrays... 14 EMC CLARiiON storage array families... 14 EMC VNX storage array families... 15 EMC Symmetrix storage arrays... 17 Required parameters for EMC Symmetrix storage arrays with Data ONTAP systems... 17 General configuration guidelines... 18 Requirements for implementing LUN security on EMC Symmetrix storage arrays... 18 Caution about using the VCMDB LUN... 19 Caution about using the ACLX LUN... 19 Restriction on using gatekeeper LUNs... 19 EMC Symmetrix storage array families... 19 Fujitsu ETERNUS storage arrays... 21

4 Implementation Guide for Third-Party Storage Requirements for configuring Fujitsu ETERNUS storage arrays with Data ONTAP systems... 21 Host Response pattern requirement for Fujitsu storage arrays... 21 Required host configuration parameters for Fujitsu DX8xxx storage arrays... 21 Required host configuration parameters for Fujitsu DX4xx storage arrays... 22 General configuration guidelines... 23 Fujitsu ETERNUS storage array families... 23 Hitachi storage arrays... 25 Required parameters for Hitachi storage arrays with Data ONTAP systems... 25 General configuration guidelines... 26 Requirements for creating LUNs in dynamic pools... 26 Requirements for formatting array LUNs... 26 Requirements for using disks external to the storage array... 27 Guidelines for configuring ports on Hitachi storage arrays... 27 Hitachi storage array families... 28 HP EVA storage arrays... 30 Required parameters for HP EVA arrays with Data ONTAP systems... 30 General configuration guidelines... 30 Requirements for configuring the HP EVA Storage Management Server... 30 Preparing HP EVA storage arrays for NDU... 30 ALUA support for HP EVA storage arrays... 32 HP EVA storage array families... 32 HP XP storage arrays... 34 Required parameters for HP XP storage arrays with Data ONTAP systems... 34 General configuration guidelines... 35 Requirements for creating LUNs in dynamic pools... 35 Requirements for formatting array LUNs... 35 Requirements for using disks external to the storage array... 35 Guidelines for configuring ports on HP XP storage arrays... 36 HP XP storage array families... 36 IBM DS storage arrays... 38 Required settings for IBM DS storage arrays with Data ONTAP systems... 38 General configuration guidelines... 39 Requirements for volume groups on DS8xxx storage arrays... 39

Table of Contents 5 Requirements for direct-attached configurations with all IBM DS arrays... 39 IBM DS storage array families... 39 IBM XIV storage arrays... 41 Requirements for configuring IBM XIV arrays with Data ONTAP systems... 41 IBM XIV storage array families... 41 3PAR storage arrays... 43 Required parameters for 3PAR arrays with Data ONTAP systems... 43 Workaround for the unknown device (L254/SES) problem with 3PAR storage arrays... 44 General configuration guidelines... 44 3PAR storage array families... 44 Supported fabric-attached configurations... 46 Stand-alone basic configuration... 46 Stand-alone with two 2-port array LUN groups... 47 Single 4-port array LUN group... 47 Two 4-port array LUN groups... 48 Eight-port array LUN group configuration... 49 Data ONTAP FC initiator port attaching to multiple targets ports... 51 Supported direct-attached configurations... 53 Two-port direct-attached stand-alone configurations... 53 Four-port direct-attached HA pair configuration... 54 Terminology comparison between storage array vendors... 55 Copyright information... 59 Trademark information... 60 How to send your comments... 61 Index... 62

6 Implementation Guide for Third-Party Storage How this guide fits into your implementation planning When planning a deployment with Data ONTAP systems and storage arrays, it is important to review the general requirements for setting up all storage arrays to work with Data ONTAP and also the specific requirements for your vendor and storage array vendor, which are discussed in this guide. Data ONTAP systems can be deployed with a variety of storage arrays. Data ONTAP requirements for working with individual storage arrays can vary by vendor and storage array. This guide provides information about the storage arrays that Data ONTAP supports at the time of publication. Not all models described in this guide are supported in all Data ONTAP releases. To determine which storage array models are supported in a particular Data ONTAP release, see the Interoperability Matrix at support.netapp.com. Note: The Interoperability Matrix is the final authority on information such as storage arrays, firmware, switches, and features that Data ONTAP supports. What to read before this guide When planning for setting up your configuration to work with storage arrays, you should start by reading the FlexArray Virtualization Installation Requirements and Reference Guide, which provides the general requirements for setting up Data ONTAP to work with storage arrays. For example, it contains general guidelines about how to configure array LUNs to work with Data ONTAP and how to set up paths to array LUNs. After you understand the requirements that apply to all vendors, you should read this guide, which provides the additional information that is specific to your vendor. How this guide is organized The information in this guide is organized in separate chapters for each storage array vendor. Each chapter includes information about the following: The requirements for parameters that must be set for each supported storage array from your vendor to be able to work with Data ONTAP Additional configuration guidelines, such as restrictions specific to an aspect of your vendor's storage array configuration The configurations that are supported for the storage arrays from your vendor The supported configurations shown for a vendor might not apply to all storage array models from the vendor. Any exceptions for individual models from a vendor are shown in the Interoperability Matrix at support.netapp.com.

How this guide fits into your implementation planning 7 Where to find out about planning for and setting up Data ONTAP features The FlexArray Virtualization guides provide information about how to set up Data ONTAP to work with storage arrays and how to set up the storage arrays to work with Data ONTAP. You should also refer to the Data ONTAP document library, which provides information about Data ONTAP features. The Data ONTAP guides also contain some procedures for installing and configuring your system to work with array LUNs.

8 Implementation Guide for Third-Party Storage Where to find interoperability and limits information for configurations with storage arrays When planning your configuration to use Data ONTAP systems with storage arrays, you need to check sources in addition to product documentation for interoperability details information. Tools available on the NetApp Support Site provide, in a central location, specific information about which features, configurations, and storage array models are supported in particular releases. Interoperability information about support for storage arrays Not all Data ONTAP releases support the same features, configurations, system models, and storage array models. During your deployment planning, you need to check Data ONTAP support information to ensure that your deployment conforms to Data ONTAP hardware and software requirements for all systems in the deployment. Previously all support information used to set up deployments with storage arrays was included in the V-Series Support Matrix. The information is divided into different tools, as shown in the following table: For information about... Data ONTAP working with devices, including the following: Supported storage arrays and storage array firmware Supported switches and switch firmware Whether your storage array supports nondisruptive (live) upgrade of the storage array firmware You should look here... Interoperability Matrix at support.netapp.com Note: The Interoperability Matrix shows the Brocade and Cisco switches that are supported. You can find guides for configuring specific vendor switches on the NetApp Support Site at support.netapp.com. Whether a MetroCluster configuration is supported with your storage array

Where to find interoperability and limits information for configurations with storage arrays 9 For information about... Data ONTAP limits for releases and platforms, including the following: You should look here... Hardware Universe at hwu.netapp.com Minimum and maximum array LUN sizes, including the minimum array LUN size for the root volume and spare core array LUNs Minimum aggregate size for aggregates with array LUNs Supported block size Minimum and maximum capacity Neighborhood limits What is supported for specific arrays, including supported configurations FlexArray Virtualization Implementation Guide for Third-Party Storage Limits information for configurations with storage arrays The Hardware Universe at hwu.netapp.com contains information about limits that you need to consider when planning for a configuration with storage arrays. The Hardware Universe includes the following limits that do not apply to native disks: Minimum and maximum array LUN size that Data ONTAP supports Minimum size for the array LUN for the root volume Spare core array LUN minimum size Limits for RAID groups with array LUNs Minimum aggregate size for an aggregate of array LUNs Maximum number of array LUNs and disks combined, per platform The Hardware Universe also contains storage limits that are the same for native disks and array LUNs. Note: Limits for V-Series systems were previously provided in the V-Series Limits Reference for Third-Party Storage and the V-Series Support Matrix.

10 Implementation Guide for Third-Party Storage Use of storage array advanced features Data ONTAP does not support storage array advanced features unless otherwise specified in the Interoperability Matrix at support.netapp.com.

11 Data ONTAP systems that can use array LUNs on storage arrays V-Series ( V ) systems and new FAS platforms released in Data ONTAP 8.2.1 and later can use array LUNs if the proper license is installed. In discussions in the Data ONTAP and FlexArray Virtualization documentation, these systems are collectively referred to as Data ONTAP systems when it is necessary to make it clear which information applies to them and what information applies to storage arrays. Note: Starting with Data ONTAP 8.2.1, the capability of using LUNs on a storage array, formerly identified as V-Series functionality, has a new name Data ONTAP FlexArray Virtualization Software. The capability of using array LUNs continues to be available as a licensed feature in Data ONTAP. Systems prior to Data ONTAP 8.2.1 that can use array LUNs The only systems released prior to Data ONTAP 8.2.1 that can use array LUNs are V-Series systems systems with a V or GF prefix. A V-Series system is an open storage controller that virtualizes storage from storage array vendors, native disks, or both into a single heterogeneous storage pool. Note: Almost all Data ONTAP platforms released prior to Data ONTAP 8.2.1 were released with FAS and V-Series equivalent models (for example, a FAS6280 and a V6280 ). (For a few systems, there were no V equivalent models.) Although both types of models could access native disks, only the V-Series systems (a V or GF prefix) could attach to storage arrays. Systems in Data ONTAP 8.2.1 and later that can use array LUNs Starting with Data ONTAP 8.2.1, the model for how platforms are released and the storage they can use changes. Attaching to storage arrays is no longer limited to V-Series systems. Starting with Data ONTAP 8.2.1, all new platforms are released as a single hardware model. This single hardware model has a FAS prefix; there are no longer separate V and FAS models for new platforms. If the V_StorageAttach license package is installed on a new FAS model, it can attach to storage arrays. (This is the same license required on a V-Series system.) Important: FAS systems released prior to Data ONTAP 8.2.1 cannot use LUNs on storage arrays, even if they are upgraded to Data ONTAP 8.2.1 or later; only the V equivalent of a platform can use array LUNs.

12 Implementation Guide for Third-Party Storage General configuration guidelines for all storage arrays This section includes general configuration guidelines for any of the storage arrays supported by Data ONTAP. Requirement for 8-Gb array port initialization In a typical Fibre Channel (FC) fabric, storage array ports initialize as N-Ports (node ports) and their corresponding switch ports initialize as F-Ports (fabric ports). In some cases, these F-ports might go offline and resume operation as L-Ports (loop ports), resulting in fabric errors. This behavior is caused by topology auto-negotiation issues in the Brocade switch. To ensure that switch ports always initialize as F-ports, you must run the portcfggport <portnumber> 1 command on Brocade switch ports that are connected to storage arrays. You must run this command when you start configuring the system to avoid this problem, and you must fix the problem if it occurs. To promote efficiency on the fabric as a whole, you can also use this workaround on any Brocade ports attached to Data ONTAP initiator ports.

13 EMC CLARiiON and VNX storage arrays You must meet specific requirements when configuring storage arrays to work with Data ONTAP systems that use array LUNs. These requirements include setting configuration parameters on your storage arrays and deploying only supported configurations. Required parameters for EMC CLARiiON and VNX storage arrays with Data ONTAP systems Certain parameter settings are required on the storage array for the storage array to work successfully with Data ONTAP systems. Host configuration parameters that must be set on the storage array are listed in the following table. Parameter Initiator type Array Com Path Setting Clariion Open or Clariion VNX Enabled Failover mode 1 Unit serial number Host Name IP address LUN User-supplied host name and port number. Unique fake IP address. Be sure that you have not entered this IP address anywhere else in the storage array configuration, and that it is not an IP address that is present on the network. General configuration guidelines Information in this section includes cautions, restrictions, special requirements, and information about array characteristics that you might need to consider when configuring or using your storage array. How EMC CLARiiON and VNX storage arrays control access to data EMC CLARiiON and VNX arrays use Storage Groups to control access to data. A Storage Group is one or more LUNs within the storage array that can be accessed only by the host or hosts that you

14 Implementation Guide for Third-Party Storage associate with the array LUNs. A host cannot access or modify data in any array LUNs that are not part of its Storage Group. Data ONTAP supports multiple Storage Groups if these rules are followed: Switch zoning must define which target ports the FC initiator ports on the Data ONTAP system use to access each array LUN group. LUN masking must be used to restrict host access to array LUNs. Storage Groups must define which array LUN groups are presented to each FC initiator port. One FC initiator port pair on each Data ONTAP system is required for each array LUN group. If array LUN neighborhoods are used, the V-Series systems in the same neighborhood must be in the same Storage Group. Limitation on array LUN numbering with EMC CLARiiON and VNX arrays EMC CLARiiON (CX) and VNX storage arrays only support array LUN numbering from 0 through 255. Array LUNs that are numbered beyond that range are not visible to Data ONTAP. Guidelines for enabling ALUA on EMC CLARiiON and VNX storage arrays Starting with clustered Data ONTAP 8.2, support has been added for ALUA (Asymmetric Logical Unit Access) with CLARiiON and VNX arrays. By default, support for ALUA is enabled in clustered Data ONTAP. But to use it, ALUA must be enabled on the storage array. You should enable ALUA only on new configurations. You should not enable ALUA in an existing configuration. If you are setting up ALUA on the storage array, you need to ensure that all hosts in a Storage Group are in the same failover mode, that is failover mode 4 (ALUA). EMC CLARiiON storage array families Data ONTAP does not support mixing some types of storage in aggregates. To help you determine the array LUNs that can be mixed in an aggregate, the storage arrays from each vendor are grouped into families. When you create aggregates, you cannot mix array LUNs from different vendors and from different storage array families in the same aggregate. Storage arrays in the same family share the same performance and failover characteristics. For example, members of the same family all perform active-active failover, or they all perform activepassive failover. More than one factor might be used to determine storage array families. For example, storage arrays with different architectures would be in different families even though other characteristics might be the same. Note: CX storage arrays use asymmetric active-active (ALUA) or active-passive failover mode; they are not active-active storage arrays.

The following list shows CLARiiON storage arrays organized by family: Family 1 CX300 CX500 CX700 Family 2 CX3-20 CX3-40 CX3-80 Family 3 CX4-120 CX4-240 CX4-480 CX4-960 The storage arrays and families shown are current at the time of publication. The Interoperability Matrix at support.netapp.com is the final authority for which storage arrays are supported for each vendor. EMC VNX storage array families Data ONTAP does not support mixing some types of storage in aggregates. To help you determine the array LUNs that can be mixed in an aggregate, the storage arrays from each vendor are grouped into families. When you create aggregates, you cannot mix array LUNs from different vendors and from different storage array families in the same aggregate. Storage arrays in the same family share the same performance and failover characteristics. For example, members of the same family all perform active-active failover, or they all perform activepassive failover. More than one factor might be used to determine storage array families. For example, storage arrays with different architectures would be in different families even though other characteristics might be the same. Note: VNX storage arrays use asymmetric active-active (ALUA) or active-passive failover mode; they are not active-active storage arrays. The following list shows the supported storage arrays, which are all in the same family: Family 1 EMC CLARiiON and VNX storage arrays 15

16 Implementation Guide for Third-Party Storage VNX5100 VNX5300 VNX5500 VNX5700 VNX7500 The storage arrays and families shown are current at the time of publication. The Interoperability Matrix at support.netapp.com is the final authority for which storage arrays are supported for each vendor.

17 EMC Symmetrix storage arrays You must meet specific requirements when configuring storage arrays to work with Data ONTAP systems that use array LUNs. These requirements include setting configuration parameters on your storage arrays and deploying only supported configurations. Required parameters for EMC Symmetrix storage arrays with Data ONTAP systems Certain parameter settings are required on the storage array for the storage array to work successfully with Data ONTAP systems. Required host channel director port configuration parameters The host channel director port configuration parameters that must be set on the storage array are shown in the following table: Parameter (names might differ between GUI and CLI) Common SN (Common Serial Number or C-bit parameter) PP (Point-to-Point parameter) SC3 (SCSI-3) SPC-2 (SCS2_Protocol_version, SCSI Primary Command 2 parameter, or Allow inquiry data to be compiled to the standard ) UWN (Unique Worldwide Name) Volume Set Addressing Setting Enable Enable Enable Enable Enable Disable The Volume Set Addressing parameter must be set the same way on all channel director ports to which the LUN is mapped. If the settings are different, Data ONTAP reports this as a LUN ID mismatch in storage errors show output and in an EMS message. See the FlexArray Virtualization Installation Requirements and Reference Guide for information about troubleshooting this error.

18 Implementation Guide for Third-Party Storage Required host configuration parameters The settings for host configuration parameters are shown in the following table: Parameter Host Type Format SCSI3_persist_reserv (Persistent Reservations) Setting Server or Open systems On General configuration guidelines Information in this section includes cautions, restrictions, special requirements, and information about array characteristics that you might need to consider when configuring or using your storage array. Requirements for implementing LUN security on EMC Symmetrix storage arrays You use LUN security to eliminate the possibility of a host writing data to a LUN that is not owned by that host. To eliminate the possibility of a non-data ONTAP host overwriting EMC Symmetrix (DMX and VMAX) array LUNs owned by a Data ONTAP system or vice versa, you must present the Symmetrix logical devices through the host (channel) director ports in one of the following ways: Present only the Symmetrix logical devices for Data ONTAP on specific Symmetrix host (channel) director ports that are dedicated to Data ONTAP use. If ports cannot be dedicated to Data ONTAP, you should confirm that all other hosts using those ports are compatible with Data ONTAP requirements. This is because each host connected to the Symmetrix array has requirements for different port attribute settings. Sharing ports between multiple hosts that are connected to the Symmetrix storage array might result in an impossible-toimplement configuration. For DMX storage arrays, use LUN masking to associate all the DMX LUNs with the FC initiator ports on the Data ONTAP system and with the host (channel) director ports that are dedicated to Data ONTAP use. For VMAX storage arrays, create masking views for required mapping and masking by creating port groups, Storage Groups, and initiator groups. To achieve this, you must first enable the ACLX port attribute on the VMAX storage array ports.. Attention: Do not present the VCMDB LUN to all hosts by default. Configure the global setting to restrict visibility to the VCMDB unless it has been specifically made visible to a particular host.

EMC Symmetrix storage arrays 19 Caution about using the VCMDB LUN For the VCMDB (Volume Configuration Management Database) to be enabled, the VCMDB LUN must exist. The VCMDB LUN is a command type LUN, not a storage LUN. The VCMDB is typically mapped to LUN 0, but can be mapped to an array LUN other than LUN 0. If the VCMDB LUN is mapped to a Data ONTAP system, Data ONTAP periodically logs a message that the VCMDB LUN is less than the minimum size required, and it marks the VCMDB LUN as failed. The Data ONTAP system continues to function normally after logging this error message, but it cannot use the LUN. A VCMDB LUN should be unmapped from a Data ONTAP system. Caution about using the ACLX LUN On VMAX arrays, the ACLX (Access Control Logix) LUN is created during initialization if the customer requests that ACLX be used. The ACLX LUN is not a storage LUN, so it should not be mapped to Data ONTAP. If the ACLX LUN is mapped to a Data ONTAP system, Data ONTAP logs a message that the ACLX LUN is less than the minimum size required, and it marks the LUN as failed. The Data ONTAP system continues to function normally after logging this error message, but it cannot use the LUN. The ACLX LUN should be unmapped from the front-end director ports on the Data ONTAP system. Restriction on using gatekeeper LUNs If a gatekeeper logical device (LUN) is presented, you must not map it to the Data ONTAP system. Data ONTAP systems cannot use gatekeeper LUNs. A gatekeeper LUN is a Symmetrix logical device through which SYMAPI or the ControlCenter agent communicates with the storage array. EMC Symmetrix storage array families Data ONTAP does not support mixing some types of storage in aggregates. To help you determine the array LUNs that can be mixed in an aggregate, the storage arrays from each vendor are grouped into families. When you create aggregates, you cannot mix array LUNs from different vendors and from different storage array families in the same aggregate. Storage arrays in the same family share the same performance and failover characteristics. For example, members of the same family all perform active-active failover, or they all perform activepassive failover. More than one factor might be used to determine storage array families. For example, storage arrays with different architectures would be in different families even though other characteristics might be the same. The following list shows the supported arrays organized by families: Family1 VMAX SE

20 Implementation Guide for Third-Party Storage VMAX 40k VMAX/VMAX 20k VMAXe/VMAX 10k Family 2 DMX 3 DMX 4 The storage arrays and families shown are current at the time of publication. The Interoperability Matrix at support.netapp.com is the final authority for which storage arrays are supported for each vendor.

21 Fujitsu ETERNUS storage arrays You must meet specific requirements when configuring storage arrays to work with Data ONTAP systems that use array LUNs. These requirements include setting configuration parameters on your storage arrays and deploying only supported configurations. Requirements for configuring Fujitsu ETERNUS storage arrays with Data ONTAP systems Certain parameter settings are required on the storage array for the storage array to work successfully with Data ONTAP systems. Host Response pattern requirement for Fujitsu storage arrays For your Data ONTAP system to work with Fujitsu storage arrays, you need to create a new Host Response pattern and set the parameters required by the Data ONTAP system. Fujitsu provides Host Response pattern #00, which is a read-only version of the specification that you edit to match the requirements of your storage array model. Required host configuration parameters for Fujitsu DX8xxx storage arrays You must set certain configuration parameters for the storage array to be able to communicate with the Data ONTAP system. Host configuration parameters that must be set on the storage array are listed in the following table: Parameter Host Response Name Command Time-out Interval Data Transfer Timer Load Balance Response Byte-0 Inquiry Response Inquiry VPD ID Type Inquiry Standard Data Version Reservation Conflict Response for Test Unit Ready Setting Name (name of the Data ONTAP system) Standard (25 seconds) 10 Seconds (Default) Unit Attention No Conversions (Default) Type1 + Type3 (Default) Version 05 (Default) Normal Response (Default)

22 Implementation Guide for Third-Party Storage Parameter Asymmetric / Symmetric Logical Unit Access Host Specific Mode LUN Mapping Changes LUN Capacity Expansion Vendor Unique Sense Code Sense Code Conversion Pattern Setting Active/Active (Default) Normal Mode (Default) No Report (Default) No Report (Default) No report (Default) No Conversion (Default) The following additional parameters must be set if you are using firmware version V10L50 or later: iscsi Discovery Reply TPGS Mode TPG Referrals iscsi Reservation Range All - Reply All Ports (Default) Enable (Default) Disable (Default) CA Port (Default) Required host configuration parameters for Fujitsu DX4xx storage arrays You must set certain configuration parameters for the storage array to be able to communicate with the Data ONTAP system. Host configuration parameters that must be set on the storage array are listed in the following table: Parameter Host Response Name Byte-0 of Inquiry response Setting Name (name of the Data ONTAP system) No conversion (Default) Inquiry VPD ID Type Type 1 + Type 3 Inquiry Standard Data Version Default (Version 05) Command Timeout Interval Load Balance Response Reservation Conflict Response for Test Unit Ready Change Volume Mapping Volume Capacity Expansion Default (25 sec) Default (Unit Attention) Default (Normal) Default (No Report) Default (No Report)

Fujitsu ETERNUS storage arrays 23 Parameter Vendor Unique Sense Code Host Specific Mode Asymmetric/Symmetric Logical Unit Access Sense Data Conversion Setting Default (No Report) Default (Normal) Active/Active/Preferred_Path (Default) Default (no conversion) The following additional parameters must be set if you are using firmware version V10L50 or later: iscsi Discovery Reply Mode TPGS Mode TPG Referrals iscsi Reservation Range All - Reply All Ports (Default) Enable (Default) Disable (Default) CA Port (Default) General configuration guidelines Information in this section includes cautions, restrictions, special requirements, and information about array characteristics that you might need to consider when configuring or using your storage array. Fujitsu ETERNUS storage array families Data ONTAP does not support mixing some types of storage in aggregates. To help you determine the array LUNs that can be mixed in an aggregate, the storage arrays from each vendor are grouped into families. When you create aggregates, you cannot mix array LUNs from different vendors and from different storage array families in the same aggregate. Storage arrays in the same family share the same performance and failover characteristics. For example, members of the same family all perform active-active failover, or they all perform activepassive failover. More than one factor might be used to determine storage array families. For example, storage arrays with different architectures would be in different families even though other characteristics might be the same. The following list shows the storage arrays supported in various Data ONTAP 8.x releases organized by family DX Generation 1 family DX8000 (DX8700, DX8400) DX400 1st generation (DX410, DX440)

24 Implementation Guide for Third-Party Storage DX Generation 2 family DX400 S2 (DX410, DX440) DX8000 S2 (DX8700) The storage arrays and families shown are current at the time of publication. The Interoperability Matrix at support.netapp.com is the final authority for which storage arrays are supported for each vendor. Note: This guide discusses only the Fujitsu storage arrays that are supported in the Data ONTAP 8.x releases. See the Interoperability Matrix for information about the ETERNUS family of storage arrays, which are supported in releases earlier than Data ONTAP 8.x. For Data ONTAP 8.0.2 and earlier, the V-Series Implementation Guide for Fujitsu ETERNUS Storage provides information about setting up the ETERNUS family models to work with Data ONTAP.

25 Hitachi storage arrays You must meet certain requirements when configuring Hitachi storage arrays to work with Data ONTAP systems that use array LUNs. These requirements include setting configuration parameters on storage arrays and deploying only supported configurations. Required parameters for Hitachi storage arrays with Data ONTAP systems Certain parameter settings are required on the storage array for the storage array to work successfully with Data ONTAP systems. Required system parameter for NSC55, USP, and VSP storage arrays The required parameter setting is shown in the following table: Parameter Setting Host type Standard or 00 Required system parameters for AMS and HUS storage arrays The parameters that must be set are listed in the following table: Parameter Mapping mode Host group security Product ID Mode Setting > Common Setting Platform Middleware Setting Enabled Enabled DF600F Standard Mode Not specified Not specified Required system parameters for HUS VM storage arrays The parameters that must be set are listed in the following table: Parameter Setting Host mode Standard or 00

26 Implementation Guide for Third-Party Storage Parameter Port security Setting Enabled Note: A host group that is separate from the default host groups should be created for each initiator-target port pair. The storage array parameters should be set and LUNs should be mapped to the host groups before the switch is zoned to connect the Data ONTAP system to the Hitachi storage array. If Data ONTAP system FC initiator ports are zoned with Hitachi array target ports before the storage array parameters are set and the LUNs are mapped to the host groups, you might not be able to see any LUNs presented to the Data ONTAP interface. In this situation, Data ONTAP generates one of the following EMS messages: [fci.device.login.reject:info] The PLOGI transmitted by port XX was rejected by port_id 0xYYYY with reason code 0x9 'Invalid R_CTL Field', explanation code 0x29 'Insufficient Resources to Support Login' [fci.device.login.reject:info]: The PLOGI transmitted by port XX was rejected by port_id 0xYYYY with reason code 0x3 'Nx_Port Not Available, Temporary', explanation code 0x29 'Insufficient Resources to Support Login' Workaround If zoning was configured prior to setting the parameters and mapping the LUNs to the host groups, you can resolve the problem of LUNs not being visible by performing a path re-initialization to force a rediscovery of the array LUNs that are mapped from the Hitachi storage array. General configuration guidelines Information in this section includes cautions, restrictions, special requirements, and information about array characteristics that you might need to consider when configuring or using your storage array. Requirements for creating LUNs in dynamic pools When creating LUNs in the dynamic pools, do not over-provision the pool capacity. Requirements for formatting array LUNs You can perform different types of array LUN formatting. Each type has an impact on the availability of LUNs or the entire storage array. If you must present a new LUN to the Data ONTAP system immediately, you should use quick formatting. If you plan to present LUNs to the Data ONTAP system in the future, quick formatting is recommended but Online formatting is acceptable.

Quick formatting is recommended because both Online and Offline formatting delay disk discovery until after the LUN formatting is complete, as described in the following list: Online formatting takes the array LUN that is being formatted completely offline, and the array LUN does not respond to any SCSI commands. Formatting is performed on one array LUN at a time until all array LUNs are formatted. Offline formatting takes the entire storage array offline and the storage array does not respond to any SCSI commands. The array LUNs are formatted six at a time per controller until the formatting is complete. The storage array does not respond until all formatting is complete. If you are creating array LUNs (for any host) after initial setup of the Data ONTAP system and you are using Offline formatting, the system panics. Any array LUNs that are mapped to the Data ONTAP system, including array LUNs in the root volume, become unavailable until formatting is complete. Online and quick formatting of LUNs for other hosts do not impact the Data ONTAP system. Requirements for using disks external to the storage array Data ONTAP supports using the same disks behind the storage arrays that the vendor supports (that is, disks external to the storage array). Data ONTAP assumes that the configuration between the storage array and the external disks behind it is correct. The following list shows restrictions and best practice recommendations for deploying storage arrays that use external disks: Root volumes and spare core LUNs are not supported on external disks. Array LUNs from external and internal disks should not be in the same Data ONTAP aggregate. Array LUNs from SATA drives and array LUNs from FC drives should not be in the same aggregate. Rules for the number of paths to array LUNs on external disks are the same as for array LUNs on disks on the storage array. In the case of external disks, the paths go from the Data ONTAP system through the storage array to the external disks. See the FlexArray Virtualization Installation Requirements and Reference Guide for information about the number of paths supported for different Data ONTAP releases and modes. Only block checksum is supported for array LUNs on external disks. Guidelines for configuring ports on Hitachi storage arrays You should follow certain guidelines when configuring ports on Hitachi storage arrays. The guidelines for configuring ports on Hitachi storage arrays are as follows: Hitachi storage arrays 27

28 Implementation Guide for Third-Party Storage You should add only one host group per port. You should ensure that a host group includes all the FC initiator ports of the V-Series systems in an array LUN neighborhood. Hitachi storage array families Data ONTAP does not support mixing some types of storage in aggregates. To help you determine the array LUNs that can be mixed in an aggregate, the storage arrays from each vendor are grouped into families. When you create aggregates, you cannot mix array LUNs from different vendors and from different storage array families in the same aggregate. Storage arrays in the same family share the same performance and failover characteristics. For example, members of the same family all perform active-active failover, or they all perform activepassive failover. More than one factor might be used to determine storage array families. For example, storage arrays with different architectures would be in different families even though other characteristics might be the same. The following list shows the storage arrays organized by family: Family 1 USP-V USP-VM Family 2 VSP Family 3 AMS 200 AMS 500 AMS 1000 Family 4 AMS 2100 AMS 2300 AMS 2500 Family 5 HUS 110 HUS 130 HUS 150

Hitachi storage arrays 29 Family 6 USP 1100 USP 600 USP 100 NSC55 Family 7 HUS VM The storage arrays and families shown are current at the time of publication. The Interoperability Matrix at support.netapp.com is the final authority for which storage arrays are supported for each vendor.

30 Implementation Guide for Third-Party Storage HP EVA storage arrays You must meet certain requirements when configuring storage arrays to work with Data ONTAP systems. These requirements include setting configuration parameters on storage arrays and deploying only supported configurations. Required parameters for HP EVA arrays with Data ONTAP systems Certain parameter settings are required on the storage array for the storage array to work successfully with Data ONTAP systems. System parameter settings are provided in the following table: Parameter Redundancy Preferred path/mode Host type Setting Any RAID level except VRAID0 No preference (default) SUN Solaris General configuration guidelines Information in this section includes cautions, restrictions, special requirements, and information about array characteristics that you might need to consider when configuring or using your storage array. Requirements for configuring the HP EVA Storage Management Server Sharing FC initiator ports present on a Data ONTAP system and initiator ports present on an HP EVA Storage Management Server with common EVA target ports causes compatibility issues. The compatibility issues result from the different host settings for the FC initiator ports present on a Data ONTAP system and the EVA Storage Management Server initiator ports. HP recommends that any HP EVA Storage Management Server that resides in a fabric be configured in a zone that is separate from all operating systems. Preparing HP EVA storage arrays for NDU HP EVA storage arrays have a tendency to bring target ports offline during a firmware upgrade. Starting in Data ONTAP 8.2, Data ONTAP provides commands that increase Data ONTAP resiliency so that the Data ONTAP system is not disrupted if target ports go offline during the

HP EVA storage arrays 31 firmware upgrade. These commands can be used only with storage systems running clustered Data ONTAP. About this task You must follow the guidelines provided by HP for performing the firmware upgrade, including guidelines about the load recommendation (HP EVA). You can upgrade only to firmware that HP supports. This procedure pertains to the HP EVA firmware upgrade type online upgrade. Note: During the firmware upgrade, both HP EVA controllers are rebooted. This procedure instructs you to use Data ONTAP commands that increase Data ONTAP resiliency throughout the firmware upgrade. After the firmware upgrade is complete, you use the Data ONTAP commands again to return the ports to their normal operating mode. Steps 1. On the Data ONTAP system, set the privilege level of the command session to advanced: set -privilege advanced 2. Set the is-upgrade-pending parameter to true for the HP EVA storage array that is undergoing a firmware upgrade: storage array modify -name array_name -is-upgrade-pending true 3. On the storage array, start the firmware upgrade. 4. After the firmware upgrade is complete, set the privilege level to advanced again, if necessary, and then on the Data ONTAP system, set the is-upgrade-pending parameter to false to return the storage array ports to normal operation: storage array modify -name array_name -is-upgrade-pending false If you did not exit advanced mode in Step 2 you do not need to access it again. The is-upgrade-pending parameter contains the following features to ensure proper use of the command: If you attempt to set is-upgrade-pending to false while the upgrade is in progress on the storage array, the command fails and an EMS message is returned. If the is-upgrade-pending status is not returned to false within 60 minutes from the time it is set to true, EMS messages are logged hourly until is-upgrade-pending is returned to false.

32 Implementation Guide for Third-Party Storage ALUA support for HP EVA storage arrays Starting with Data ONTAP 8.1, support has been added for asymmetric logical unit access (ALUA) with HP EVA arrays. By default, support for ALUA is enabled in Data ONTAP as well as on all the HP EVA storage arrays. HP EVA storage array families Data ONTAP does not support mixing some types of storage in aggregates. To help you determine the array LUNs that can be mixed in an aggregate, the storage arrays from each vendor are grouped into families. When you create aggregates, you cannot mix array LUNs from different vendors and from different storage array families in the same aggregate. Storage arrays in the same family share the same performance and failover characteristics. For example, members of the same family all perform active-active failover, or they all perform activepassive failover. More than one factor might be used to determine storage array families. For example, storage arrays with different architectures would be in different families even though other characteristics might be the same. The following list shows the storage arrays organized by family: Family 1 P6300 P6350 P6500 P6550 Family 2: HP EVAx100 EVA 4100 EVA 6100 EVA 8100 Family 3 EVA 4000 EVA 6000 EVA 8000 Family 4

HP EVA storage arrays 33 EVA 4400 EVA 6400 EVA 8400 The storage arrays and families shown are current at the time of publication. The Interoperability Matrix at support.netapp.com is the final authority for which storage arrays are supported for each vendor.

34 Implementation Guide for Third-Party Storage HP XP storage arrays You must meet certain requirements when configuring storage arrays to work with Data ONTAP systems that use array LUNs. These requirements include setting configuration parameters on storage arrays and deploying only supported configurations. Required parameters for HP XP storage arrays with Data ONTAP systems Certain parameter settings are required on the storage array for the storage array to work successfully with Data ONTAP systems. The required parameter setting is shown in the following table: Parameter Setting Host type standard or 00 The storage array parameters should be set and LUNs should be mapped to the host groups before the switch is zoned to connect the Data ONTAP system to an HP XP storage array. If Data ONTAP system FC initiator ports are zoned with HP XP array target ports before the storage array parameters are set and the LUNs are mapped to the host groups, you might not be able to see any LUNs presented to the Data ONTAP interface. In this situation, Data ONTAP generates one of the following EMS messages: [fci.device.login.reject:info] The PLOGI transmitted by port XX was rejected by port_id 0xYYYY with reason code 0x9 'Invalid R_CTL Field', explanation code 0x29 'Insufficient Resources to Support Login' [fci.device.login.reject:info]: The PLOGI transmitted by port XX was rejected by port_id 0xYYYY with reason code 0x3 'Nx_Port Not Available, Temporary', explanation code 0x29 'Insufficient Resources to Support Login' Workaround If zoning was configured prior to setting the parameters and mapping the LUNs to the host groups, you can resolve the problem of LUNs not being visible by performing a path re-initialization to force a rediscovery of the array LUNs that are mapped from the HP XP storage array.

HP XP storage arrays 35 General configuration guidelines Information in this section includes cautions, restrictions, special requirements, and information about array characteristics that you might need to consider when configuring or using your storage array. Requirements for creating LUNs in dynamic pools When creating LUNs in the dynamic pools, do not over-provision the pool capacity. Requirements for formatting array LUNs You can perform different types of array LUN formatting. Each type has an impact on the availability of LUNs or the entire storage array. If you must present a new LUN to the Data ONTAP system immediately, you should use quick formatting. If you plan to present LUNs to the Data ONTAP system in the future, quick formatting is recommended but Online formatting is acceptable. Quick formatting is recommended because both Online and Offline formatting delay disk discovery until after the LUN formatting is complete, as described in the following list: Online formatting takes the array LUN that is being formatted completely offline, and the array LUN does not respond to any SCSI commands. Formatting is performed on one array LUN at a time until all array LUNs are formatted. Offline formatting takes the entire storage array offline and the storage array does not respond to any SCSI commands. The array LUNs are formatted six at a time per controller until the formatting is complete. The storage array does not respond until all formatting is complete. If you are creating array LUNs (for any host) after initial setup of the Data ONTAP system and you are using Offline formatting, the system panics. Any array LUNs that are mapped to the Data ONTAP system, including array LUNs in the root volume, become unavailable until formatting is complete. Online and quick formatting of LUNs for other hosts do not impact the Data ONTAP system. Requirements for using disks external to the storage array Data ONTAP supports using the same disks behind the storage arrays that the vendor supports (that is, disks external to the storage array). Data ONTAP assumes that the configuration between the storage array and the external disks behind it is correct. The following list shows restrictions and best practice recommendations for deploying storage arrays that use external disks:

36 Implementation Guide for Third-Party Storage Root volumes and spare core LUNs are not supported on external disks. Array LUNs from external and internal disks should not be in the same Data ONTAP aggregate. Array LUNs from SATA drives and array LUNs from FC drives should not be in the same aggregate. Rules for the number of paths to array LUNs on external disks are the same as for array LUNs on disks on the storage array. In the case of external disks, the paths go from the Data ONTAP system through the storage array to the external disks. See the FlexArray Virtualization Installation Requirements and Reference Guide for information about the number of paths supported for different Data ONTAP releases and modes. Only block checksum is supported for array LUNs on external disks. Guidelines for configuring ports on HP XP storage arrays You should follow certain guidelines when configuring ports on HP XP storage arrays. The guidelines for configuring ports on HP XP storage arrays are as follows: You should add only one host group per port. You should ensure that a host group includes all the FC initiator ports of the V-Series systems in an array LUN neighborhood. HP XP storage array families Data ONTAP does not support mixing some types of storage in aggregates. To help you determine the array LUNs that can be mixed in an aggregate, the storage arrays from each vendor are grouped into families. When you create aggregates, you cannot mix array LUNs from different vendors and from different storage array families in the same aggregate. Storage arrays in the same family share the same performance and failover characteristics. For example, members of the same family all perform active-active failover, or they all perform activepassive failover. More than one factor might be used to determine storage array families. For example, storage arrays with different architectures would be in different families even though other characteristics might be the same. The following list shows the storage arrays organized by family: Family 1 P9500 Family 2 XP24000 XP20000

HP XP storage arrays 37 XP12000 XP10000 The storage arrays and families shown are current at the time of publication. The Interoperability Matrix at support.netapp.com is the final authority for which storage arrays are supported for each vendor.

38 Implementation Guide for Third-Party Storage IBM DS storage arrays You must meet certain requirements when configuring storage arrays to work with Data ONTAP systems that use array LUNs. These requirements include setting configuration parameters on storage arrays and deploying only supported configurations. Required settings for IBM DS storage arrays with Data ONTAP systems Certain parameter settings are required on the storage array for the storage array to work successfully with Data ONTAP systems. Required host type for DS8xxx storage arrays The required host type setting is shown in the following table: Parameter Host type Setting nseries Required host type for DS3950, DS4xxx, and DS5xxx storage arrays The required host type setting is shown in the following table: Parameter Host type Setting AIX Requirements for configuring DS8300 9A2 LPAR models When setting up the DS8300 9A2 LPAR (system logical partition) model to interact with Data ONTAP systems, you must set up access to each array LUN so that the redundant paths are both accessing the same LPAR.

IBM DS storage arrays 39 General configuration guidelines Information in this section includes cautions, restrictions, special requirements, and information about array characteristics that you might need to consider when configuring or using your storage array. Requirements for volume groups on DS8xxx storage arrays You must be aware of limitations on the number of volume groups that you can use with a LUN group when configuring DS8xxx arrays. You must use a single volume group for each LUN group on a DS8xxx storage array to guarantee that the DS8xxx array LUNs are consistently presented to all the FC initiators (that are on the Data ONTAP system) that access them. Attention: If array LUNs are not presented consistently, there is a potential for data corruption. Requirements for direct-attached configurations with all IBM DS arrays Direct-attached connections to IBM DS storage arrays, supported only for existing deployments, require specific configuration settings on the storage array. The following list describes the requirements that must be met when configuring direct-attached IBM DS arrays. Host Attachment files for the array ports must be created. The Host Attachment Port type must be set to FcAL (Fibre Channel Arbitrated Loop). The Storage Image I/O port must be set to FcAL. Note: Direct-attached configurations are not supported for new deployments. This information is provided as a reference for configurations that might already exist in the field. IBM DS storage array families Data ONTAP does not support mixing some types of storage in aggregates. To help you determine the array LUNs that can be mixed in an aggregate, the storage arrays from each vendor are grouped into families. When you create aggregates, you cannot mix array LUNs from different vendors and from different storage array families in the same aggregate. Storage arrays in the same family share the same performance and failover characteristics. For example, members of the same family all perform active-active failover, or they all perform activepassive failover. More than one factor might be used to determine storage array families. For example, storage arrays with different architectures would be in different families even though other characteristics might be the same.

40 Implementation Guide for Third-Party Storage The following list shows arrays organized by family: Family 1 DS4800 DS4700 DS4200 Family 2 DS5100 DS5300 Family 3 DS8300 DS8100 Family 4 DS5020 DS3950 Family 5 DS8800 model 951 DS8700 models 941, 94E DS8870 The storage arrays and families shown are current at the time of publication. The Interoperability Matrix at support.netapp.com is the final authority for which storage arrays are supported for each vendor.

41 IBM XIV storage arrays You must meet certain requirements when configuring storage arrays to work with Data ONTAP systems that use array LUNs. These requirements include setting configuration parameters on storage arrays and deploying only supported configurations. Requirements for configuring IBM XIV arrays with Data ONTAP systems Certain parameter settings are required on the storage array for the storage array to work successfully with Data ONTAP systems. System parameter settings System parameter settings for IBM XIV Gen2 and Gen3 arrays are provided in the following table: Parameter Type Host Cluster Setting Default User-supplied host name User-supplied cluster name IBM XIV storage array families Data ONTAP does not support mixing some types of storage in aggregates. To help you determine the array LUNs that can be mixed in an aggregate, the storage arrays from each vendor are grouped into families. When you create aggregates, you cannot mix array LUNs from different vendors and from different storage array families in the same aggregate. Storage arrays in the same family share the same performance and failover characteristics. For example, members of the same family all perform active-active failover, or they all perform activepassive failover. More than one factor might be used to determine storage array families. For example, storage arrays with different architectures would be in different families even though other characteristics might be the same. The following list shows the storage arrays organized by family: IBM XIV Gen 2 2810-A14 2812-A14

42 Implementation Guide for Third-Party Storage IBM XIV Gen 3 2810-114 2812-114 The storage arrays and families shown are current at the time of publication. The Interoperability Matrix at support.netapp.com is the final authority for which storage arrays are supported for each vendor.

43 3PAR storage arrays You must meet certain requirements when configuring storage arrays to work with Data ONTAP systems that use array LUNs. These requirements include setting configuration parameters on storage arrays and deploying only supported configurations. Required parameters for 3PAR arrays with Data ONTAP systems Certain parameter settings are required on the storage array for the storage array to work successfully with Data ONTAP systems. Host persona settings For 3PAR arrays with firmware 2.3.1 and later, the required host persona values must be set as shown in the following table: Connection type Direct connect 10 Fabric attached 10 Host persona The host definition, with the required host persona, should be created on a 3PAR storage array before the switch is zoned to connect the Data ONTAP system to a 3PAR storage array. If zoning is configured before the host definition, Data ONTAP discovers a 3PAR LUN as LUN 254 and product type SES, which Data ONTAP cannot use. The result is that newly mapped 3PAR LUNs cannot be assigned to Data ONTAP system and some 3PAR LUNs that might have already been added to an aggregate cannot be used because Data ONTAP sees a LUN 254 instead of a 3PAR LUN. If this problem occurs, Data ONTAP generates the following EMS message: mlm.array.unknown:warning - Array LUN XXXXXXXX.126L254 [S/N 'XXXXXXX' vendor '3PARdata' product 'SES'] is unknown and is not supported in this version of Data ONTAP. If zoning was configured prior to the host definition, you can resolve the problem by doing path reinitialization to force a rediscovery of the array LUNs that are mapped from the 3PAR storage array. See Workaround for the unknown device (L254/SES) problem with 3PAR storage arrays on page 44 for the workaround for this problem. Port persona settings For 3PAR arrays with firmware 2.2.x, the required port persona values must be set as shown in the following table:

44 Implementation Guide for Third-Party Storage Connection type Direct connect 18 Fabric attached 19 Port persona Workaround for the unknown device (L254/SES) problem with 3PAR storage arrays The host definition, with the host persona specified in the Required parameters for 3PAR arrays with Data ONTAP systems on page 43, should be created on a 3PAR storage array before the switch is zoned to connect the Data ONTAP system to a 3PAR storage array. If zoning is configured before the host definition, Data ONTAP discovers a 3PAR array LUN as LUN 254 and product type SES, which Data ONTAP cannot use. When Data ONTAP discovers 3PAR array LUNs as LUN 254 and product type SES, newly mapped 3PAR LUNs cannot be assigned to Data ONTAP systems and some 3PAR LUNs that might have already been added to an aggregate cannot be used because Data ONTAP sees a LUN 254. Data ONTAP generates EMS messages for the LUN it discovered as LUN 254 and product type SES, reporting some LUNs as unknown devices. If zoning was configured before the host definition, you can resolve the LUN 254/SES unknown device problem by forcing a rediscovery of the array LUNs that are mapped from the 3PAR storage array. The procedure you use depends on whether aggregates with 3PAR array LUNs have already been configured on the Data ONTAP system. (In the following procedures, assume that Node-1 and Node-2 are the names of the Data ONTAP nodes.) General configuration guidelines Information in this section includes cautions, restrictions, special requirements, and information about array characteristics that you might need to consider when configuring or using your storage array. 3PAR storage array families Data ONTAP does not support mixing some types of storage in aggregates. To help you determine the array LUNs that can be mixed in an aggregate, the storage arrays from each vendor are grouped into families. When you create aggregates, you cannot mix array LUNs from different vendors and from different storage array families in the same aggregate. Storage arrays in the same family share the same performance and failover characteristics. For example, members of the same family all perform active-active failover, or they all perform activepassive failover. More than one factor might be used to determine storage array families. For example, storage arrays with different architectures would be in different families even though other characteristics might be the same. The following list shows the storage arrays organized by family:

3PAR storage arrays 45 Family 1 E200 Family 2 S400 S800 Family 3 T400 T800 Family 4 F200 F400 Family 5 P10000 - V400 P10000 - V800 3PAR StoreServ 7200 3PAR StoreServ 7400 The storage arrays and families shown are current at the time of publication. The Interoperability Matrix at support.netapp.com is the final authority for which storage arrays are supported for each vendor.

46 Implementation Guide for Third-Party Storage Supported fabric-attached configurations The fabric-attached configurations included in this section are supported for all the storage array vendors unless mentioned otherwise. For additional information about configuration with specific storage arrays, see the Interoperability Matrix at support.netapp.com. Stand-alone basic configuration The stand-alone basic configuration of a Data ONTAP system that uses array LUNs is a simple, fabric-attached configuration with a single FC initiator port pair accessing a single LUN group. This configuration is supported for use with all storage arrays listed in the Interoperability Matrix as supported for the release and mode of Data ONTAP running on your system. The following illustration shows this configuration: vs1 0a 0b 0c 0d 0e 0f 0g 0h Switch 1 Switch 2 1A LUN group 2A Controller 1 Controller 2 Storage array

Supported fabric-attached configurations 47 Stand-alone with two 2-port array LUN groups This is a stand-alone Data ONTAP system in a fabric-attached simple configuration. In this configuration, each Data ONTAP system FC initiator port pair accesses a separate array LUN group. This configuration is supported for use with all storage arrays listed in the Interoperability Matrix as supported for the release and mode of Data ONTAP running on your system. The following illustration shows this configuration: vs1 0a 0b 0c 0d 0e 0f 0g 0h z1 z2 z3 z4 Switch 1 Switch 2 z3 z2 1A LUN group 1 2A z1 1B LUN group 2 Controller 1 2B z4 Controller 2 Storage array Single 4-port array LUN group This configuration contains a single, 4-port LUN group with each target port accessed by a single Data ONTAP system FC initiator port from the HA pair. Zoning ensures that there are only two paths to a specific array LUN from each Data ONTAP system. This configuration is supported for use with all storage arrays listed in the Interoperability Matrix as supported for the release and mode of Data ONTAP running on your system. The following illustration shows this configuration:

48 Implementation Guide for Third-Party Storage vs1 vs2 0a 0b 0c 0d 0a 0b 0c 0d z1 z3 z2 z4 Switch 1 Switch 2 z1 z3 z2 z4 1A 1B LUN group 1 2A 2B Storage array Controller 1 Controller 2 Two 4-port array LUN groups In this configuration, each Data ONTAP FC initiator port pair accesses a separate array LUN group. The zoning is a single Data ONTAP system FC initiator to a single array target port. This configuration is supported for use with all storage arrays listed in the Interoperability Matrix as supported for the release and mode of Data ONTAP running on your system. The following illustration shows a block diagram of this configuration:

Supported fabric-attached configurations 49 vs1 vs2 0a 0b 0c 0d 0a 0b 0c 0d z1 z5 z3 z7 z2 z6 z4 z8 Switch 1 Switch 2 z6 z1 1A z2 1B z5 1C 1D LUN Group 1 LUN Group 2 2A 2B 2C 2D Controller 1 Controller 2 z3 z4 z7 z8 Storage array Eight-port array LUN group configuration Starting in Data ONTAP 8.2, an eight-port LUN group configuration is supported on clustered V- Series systems and, starting in Data ONTAP 8.2.1, also on Data ONTAP systems that can use array LUNs. This configuration is supported for use with all storage arrays listed in the Interoperability Matrix as supported for the release and mode of Data ONTAP running on your system. There are two ways of deploying this configuration: crossed and uncrossed back-end connections. Crossed back-end connections In this configuration with the back-end connections crossed, the FC connections from the same storage array controller go to both fabric switches (redundant). In this illustration of crossed back-end connections, note how the nodes are attached to the switches and to the storage array. Vs1 uses switch 1 when attaching to the storage array Controller 1 port 1A and Controller 2 port 2C, and uses switch 2 when attaching to storage array Controller 2 ports 2A and

50 Implementation Guide for Third-Party Storage Controller 1 port 1C. This optimizes the use of switch ports and array ports, which reduces the impact of a switch or storage array controller failure. vs1 vs2 0a 0b 0c 0d 0a 0b 0c 0d z1 z3 z5 z7 z2 z4 z6 z8 Switch 1 Switch 2 z1 z8 z2 z7 1A 1B 1C 1D LUN Group 1 2A 2B 2C 2D z5 z6 z3 z4 Storage array Controller 1 Controller 2 Note: The following problem can occur with Active-Passive storage arrays in crossed back-end connections: If one of the fabric switches is taken offline or goes down and a path failure from both Data ONTAP systems occurs, the Data ONTAP systems panic even though the alternate path from each system is still online. For example, if switch 2 is down and the 0b paths on both vs1 and vs2 go down, vs1 and vs2 panic even though the 0a paths are still online. Back-end connections are not crossed In this configuration in which the back-end connections are not crossed, the FC connections from the same storage array controller go to only one fabric switch. The following illustration shows this configuration when the back-end connections are not crossed.

Supported fabric-attached configurations 51 vs1 vs2 0a 0b 0c 0d 0a 0b 0c 0d z1 z3 z5 z7 z2 z4 z6 z8 Switch 1 Switch 2 z1 z1 z2 z3 z4 1A 1B 1C 1D LUN Group 1 2A 2B 2C 2D z5 z6 z7 z8 Storage array Controller 1 Controller 2 Data ONTAP FC initiator port attaching to multiple targets ports Starting in Data ONTAP 8.2, a Data ONTAP FC initiator port can be attached to multiple target ports on separate storage arrays within the same family. The FlexArray Virtualization Installation Requirements and Reference Guide contains the rules for setting up this configuration. This configuration is not supported with MetroCluster configurations. This configuration is supported for use with all storage arrays listed in the Interoperability Matrix as supported for the release and mode of Data ONTAP running on your system. The following illustration shows a shared Data ONTAP FC initiator port configuration with an HA pair. However, sharing an FC initiator port with multiple target ports is supported with both standalone systems and HA pairs. For details about sharing an FC initiator port with multiple target ports and zoning, see the information in the FlexArray Virtualization Installation Requirements and Reference Guide.

52 Implementation Guide for Third-Party Storage One Data ONTAP FC initiator port connecting to target ports on separate storage arrays The following example shows an HA pair in which a single Data ONTAP FC initiator port connects to multiple target ports on different storage arrays: vs1 vs2 0a 0b 0c 0d 0a 0b 0c 0d z1/z2 z5/z6 z7/z8 Fabric 1 z3/z4 Fabric 2 Switch 1 Switch 2 z1 z5 z4 z3 1A 1B LUN group 2A 2B z7 z8 Storage array 1 z2 z6 1A 1B LUN group 2A 2B Storage array 2 Controller 1 Controller 2

53 Supported direct-attached configurations Direct-attached configurations are not supported for new deployments. For older deployments, direct-attached configurations are limited to some storage arrays and some Data ONTAP releases. See the Interoperability Matrix for information about configurations supported for direct attachment. Two-port direct-attached stand-alone configurations Direct-attached configurations are not supported for new deployments. For older deployments, direct-attached configurations are limited to some storage arrays and some Data ONTAP releases. See the Interoperability Matrix for information about configurations supported for direct attachment. The following illustration is shown as a reference for configurations that might already exist in the field. Two Data ONTAP FC initiator ports provide access to LUNs on the storage array. 0a 0b 0c 0d 0e 0f 0g 0h 1A LUN group 2A Controller 1 Controller 2 Storage array

54 Implementation Guide for Third-Party Storage Four-port direct-attached HA pair configuration Direct-attached configurations are not supported for new deployments. For older deployments, direct-attached configurations are limited to some storage arrays and some Data ONTAP releases. See the Interoperability Matrix for information about configurations supported for direct attachment. The following illustration is shown as a reference for configurations that might already exist in the field. The illustration shows a direct-attached HA pair with four ports providing access to array LUNs on the storage array. vs1 vs2 0a 0b 0c 0d 0a 0b 0c 0d 1A 1B LUN group 2A 2B Storage array Controller 1 Controller 2

55 Terminology comparison between storage array vendors Different storage array vendors occasionally use different terms to describe similar concepts. Conversely, the meaning of the same term might differ between array vendors. The following table provides a mapping between some common vendor terms: Term Vendor Definition host group Hitachi, Sun A configuration entity that IBM DS4xxx/DS5xxx EMC DMX HP XP enables you to specify host access to ports on the storage array. You identify the FC initiator port WWNs for the Data ONTAP system that you volume group IBM DS8xxx want to access the LUNs; the Storage Group EMC CX process differs according to vendor and sometimes differs cluster IBM XIV for different storage array models of the same vendor. host affinity group Fujitsu ETERNUS4000, ETERNUS6000, ETERNUS8000, ETERNUS DX8000, ETERNUS DX400 host definition host 3PAR 3PAR, HP EVA, HP XP, Hitachi IBM ESS No concept of host group. You must create a host in the ESS user interface for each FC initiator port that you plan to connect to the storage array and map each host to a port. parity group RAID group array, RAID set IBM DS8xxx, IBM ESS, Hitachi, HP XP, Sun Data ONTAP, EMC CX, Fujitsu ETERNUS IBM DS4xxx/DS5xxx The arrangement of disks in the back-end that together form the defined RAID level.

56 Implementation Guide for Third-Party Storage Term Vendor Definition Parity RAID, Parity RAID group EMC DMX A DMX feature that provides parity data protection on the disk device level using physical parity volumes. disk group HP EVA A set of physical disks that form storage pools from which you can create virtual disks. parity set, RAID set 3PAR A group of parity-protected chunklets. (A chunklet is a 256-MB block of contiguous space on a physical disk.) cluster Data ONTAP In clustered Data ONTAP 8.x, a grouping of nodes that enables multiple nodes to pool their resources into a large virtual server and to distribute work across the cluster. Hitachi, HP XP, Sun IBM XIV A hardware component on the storage arrays that contains the ports to which hosts attach. An entity that groups multiple hosts together and assigns the same mapping to all the hosts. controller Data ONTAP The component of a storage system that runs the Data ONTAP operating system and interacts with back-end storage arrays. Controllers are also sometimes called heads or CPU modules. Hitachi, HP EVA, HP XP, IBM Hardware on the storage array on which the target ports are located.

Terminology comparison between storage array vendors 57 Term Vendor Definition interface module IBM XIV A hardware component on the node 3-PAR storage arrays that contains the ports to which hosts attach. FEBE Board EMC Symmetrix Storage processor (SP) Controller Module EMC CLARiiON Fujitsu ETERNUS LUN Many storage arrays A grouping of one or more LDEV Hitachi, HP XP disks or disk partitions into one span of disk storage space. In the Data ONTAP documentation, this is referred to as array LUN. LUN Data ONTAP The Data ONTAP system can virtualize the storage attached to it and serve the storage up as LUNs to external applications and clients (for example, through iscsi and FC). Clients are unaware of where a frontend LUN is stored. LUN, virtual disk HP EVA A virtual disk (called a Vdisk in the user interface) is a simulated disk drive created in a disk group. You can assign a combination of characteristics to a virtual disk, such as a name, redundancy level, and size. Presenting a virtual disk offers its storage to a host. array LUN Data ONTAP documentation, Data ONTAP storage management tools The Data ONTAP documentation uses the term array LUN to distinguish LUNs on the storage arrays from front-end LUNs (Data ONTAP LUNs).

58 Implementation Guide for Third-Party Storage Term Vendor Definition vlun 3PAR (volume-lun) A pairing between a virtual volume and a logical unit number (LUN). For a host to see a virtual volume, the volume must be exported as a LUN by creating vluns on the storage array. volume IBM, IBM XIV Equivalent to what other storage array vendors call a LUN. Data ONTAP EMC DMX A logical entity that holds user data that is accessible through one or more of the access protocols supported by Data ONTAP, including Network File System (NFS), Common Internet File System (CIFS), HyperText Transfer Protocol (HTTP), Fibre Channel (FC), and Internet SCSI (iscsi). A general term referring to a storage device. A physical volume corresponds to a single disk device. virtual volume 3PAR A virtual storage unit created by mapping data from one or more logical disks.

59 Copyright information Copyright 1994 2014 NetApp, Inc. All rights reserved. Printed in the U.S. No part of this document covered by copyright may be reproduced in any form or by any means graphic, electronic, or mechanical, including photocopying, recording, taping, or storage in an electronic retrieval system without prior written permission of the copyright owner. Software derived from copyrighted NetApp material is subject to the following license and disclaimer: THIS SOFTWARE IS PROVIDED BY NETAPP "AS IS" AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE HEREBY DISCLAIMED. IN NO EVENT SHALL NETAPP BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. NetApp reserves the right to change any products described herein at any time, and without notice. NetApp assumes no responsibility or liability arising from the use of products described herein, except as expressly agreed to in writing by NetApp. The use or purchase of this product does not convey a license under any patent rights, trademark rights, or any other intellectual property rights of NetApp. The product described in this manual may be protected by one or more U.S. patents, foreign patents, or pending applications. RESTRICTED RIGHTS LEGEND: Use, duplication, or disclosure by the government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.277-7103 (October 1988) and FAR 52-227-19 (June 1987).

60 Implementation Guide for Third-Party Storage Trademark information NetApp, the NetApp logo, Network Appliance, the Network Appliance logo, Akorri, ApplianceWatch, ASUP, AutoSupport, BalancePoint, BalancePoint Predictor, Bycast, Campaign Express, ComplianceClock, Customer Fitness, Cryptainer, CryptoShred, CyberSnap, Data Center Fitness, Data ONTAP, DataFabric, DataFort, Decru, Decru DataFort, DenseStak, Engenio, Engenio logo, E-Stack, ExpressPod, FAServer, FastStak, FilerView, Fitness, Flash Accel, Flash Cache, Flash Pool, FlashRay, FlexCache, FlexClone, FlexPod, FlexScale, FlexShare, FlexSuite, FlexVol, FPolicy, GetSuccessful, gfiler, Go further, faster, Imagine Virtually Anything, Lifetime Key Management, LockVault, Manage ONTAP, Mars, MetroCluster, MultiStore, NearStore, NetCache, NOW (NetApp on the Web), Onaro, OnCommand, ONTAPI, OpenKey, PerformanceStak, RAID-DP, ReplicatorX, SANscreen, SANshare, SANtricity, SecureAdmin, SecureShare, Select, Service Builder, Shadow Tape, Simplicity, Simulate ONTAP, SnapCopy, Snap Creator, SnapDirector, SnapDrive, SnapFilter, SnapIntegrator, SnapLock, SnapManager, SnapMigrator, SnapMirror, SnapMover, SnapProtect, SnapRestore, Snapshot, SnapSuite, SnapValidator, SnapVault, StorageGRID, StoreVault, the StoreVault logo, SyncMirror, Tech OnTap, The evolution of storage, Topio, VelocityStak, vfiler, VFM, Virtual File Manager, VPolicy, WAFL, Web Filer, and XBB are trademarks or registered trademarks of NetApp, Inc. in the United States, other countries, or both. IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. A complete and current list of other IBM trademarks is available on the web at www.ibm.com/legal/copytrade.shtml. Apple is a registered trademark and QuickTime is a trademark of Apple, Inc. in the United States and/or other countries. Microsoft is a registered trademark and Windows Media is a trademark of Microsoft Corporation in the United States and/or other countries. RealAudio, RealNetworks, RealPlayer, RealSystem, RealText, and RealVideo are registered trademarks and RealMedia, RealProxy, and SureStream are trademarks of RealNetworks, Inc. in the United States and/or other countries. All other brands or products are trademarks or registered trademarks of their respective holders and should be treated as such. NetApp, Inc. is a licensee of the CompactFlash and CF Logo trademarks. NetApp, Inc. NetCache is certified RealSystem compatible.

61 How to send your comments You can help us to improve the quality of our documentation by sending us your feedback. Your feedback is important in helping us to provide the most accurate and high-quality information. If you have suggestions for improving this document, send us your comments by email to doccomments@netapp.com. To help us direct your comments to the correct division, include in the subject line the product name, version, and operating system. You can also contact us in the following ways: NetApp, Inc., 495 East Java Drive, Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277

62 Implementation Guide for Third-Party Storage Index 3PAR storage arrays configuration requirements 43 families (storage array) 44 troubleshooting unknown device problems 44 8-port array LUN group configuration support for 49 A ACLX LUN caution about using 19 ALUA support for HP EVA 32 ALUA support with EMC CX and VNX guidelines for enabling 14 AMS storage arrays required system parameters 25 array LUNs systems running Data ONTAP that can use 11 array port initialization requirements for 12 C channel director ports parameter settings 17 configuration requirements 3PAR 43 EMC Symmetrix 17 Fujitsu ETERNUS 21, 22 Hitachi 25 HP EVA 30 HP XP 34 IBM DS 38 IBM XIV 41 configurations supported with storage arrays 8-port array LUN group 49 FC initiator port attaching to multiple targets ports 51 four-port direct-attached HA pair 54 single 4-port array LUN group 47 stand-alone basic configuration 46 stand-alone with two 2-port array LUN groups 47 two 4-port array LUN groups 48 two-port direct-attached stand-alone 53 D direct-attached configurations requirements for IBM DS arrays 39 DS8xxx storage arrays volume group number requirements 39 DX4xx storage arrays host parameter settings 22 DX8xxx storage arrays host parameter settings 21 E EMC CLARiiON storage arrays ALUA support 14 array LUN numbering 14 families (storage array) 14 required parameters with Data ONTAP systems 13 Storage Group use 13 EMC Symmetrix storage arrays caution about using the ACLX LUN 19 caution about using the VCMDB LUN 19 channel director port parameter settings 17 configuration requirements 17 gatekeeper LUN use restriction 19 host configuration parameters 17 EMC VNX storage arrays ALUA support 14 array LUN numbering 14 families (storage array) 15 required parameters with Data ONTAP systems 13 Storage Group use 13 F families (storage array) 3PAR 44 EMC CLARiiON 14 EMC Symmetrix 19 EMC VNX 15 Fujitsu ETERNUS 23 Hitachi 28 HP EVA 32 HP XP 36 IBM DS 39 IBM XIV 41

Index 63 FC initiator ports sharing target ports supported configuration 51 formatting array LUNs Hitachi 26, 35 HP XP 26, 35 four-port direct-attached HA pair configuration support for 54 Fujitsu ETERNUS storage arrays configuration requirements 21, 22 DX8xxx parameter settings 21 families (storage array) 23 Host Response pattern 21 G gatekeeper LUNs restrictions for using 19 H Hitachi storage arrays configuration requirements 25 Data ONTAP requirements for external disks 27, 35 families (storage array) 28 formatting array LUNs 26, 35 port configuration guidelines 27 host configuration parameters EMC Symmetrix 17 host parameter settings DX4xx storage arrays 22 host persona 43 Host Response pattern 21 HP EVA storage arrays ALUA support 32 configuration requirements 30 families (storage array) 32 preparing for NDU 30 zoning requirements 30 HP XP storage arrays configuration requirements 34 Data ONTAP requirements for external disks 27, 35 families (storage array) 36 formatting array LUNs 26, 35 port configuration guidelines 36 HUS storage arrays required system parameters 25 I IBM DS storage arrays configuration requirements 38 families (storage array) 39 host type setting 38 requirements for direct-attached connections 39 IBM XIV storage arrays configuration requirements 41 families (storage array) 41 parameter settings 41 implementation planning information needed for 6 initiator ports sharing with multiple target ports supported configuration 51 Interoperability Matrix support information in 8 L limits for storage arrays where to find information needed for planning 9 LUN limits where to find information needed for planning 9 LUN security EMC Symmetrix storage arrays LUN security methods 18 LUNs (array) systems running Data ONTAP that can use 11 LUNs, array See LUNs (array) N NDUs preparing HP EVA storage arrays for 30 NSC55 storage arrays required system parameters 25 P parameters required for EMC CLARiiON and VNX storage arrays with Data ONTAP systems 13 port persona settings 43 portcfggport command use for array port initialization 12 ports configuration guidelines for Hitachi 27

64 Implementation Guide for Third-Party Storage R configuration guidelines for HP XP 36 sharing initiator port with target ports supported configuration 51 required parameters for EMC CLARiiON storage arrays with Data ONTAP systems 13 for EMC VNX storage arrays with Data ONTAP systems 13 S shared FC initiator target ports supported configuration 51 single 4-port array LUN group configuration support for 47 stand-alone basic configuration support for 46 stand-alone with two 2-port array LUN groups configuration support for 47 storage array families 3PAR 44 EMC CLARiiON 14 EMC Symmetrix 19 EMC VNX 15 Fujitsu ETERNUS 23 Hitachi 28 HP EVA 32 HP XP 36 IBM DS 39 IBM XIV 41 storage arrays configuration guidelines for 12 preparing for NDUs on HP EVA 30 supported, where to find information about 8 Storage Groups ALUA support with 14 guidelines for enabling ALUA with 14 how used for access control 13 support for ALUA in HP EVA 32 Support Matrix See Interoperability Matrix supported configurations with storage arrays 8-port array LUN group 49 FC initiator port attaching to multiple targets ports 51 four-port direct-attached HA pair 54 single 4-port array LUN group 47 stand-alone basic configuration 46 stand-alone with two 2-port array LUN groups 47 two 4-port array LUN groups 48 two-port direct-attached stand-alone 53 switches supported with back-end storage arrays finding information about 8 T terminology storage array vendor 55 two 4-port array LUN groups configuration support for 48 two-port direct-attached stand-alone configuration support for 53 U USP storage arrays required system parameters 25 V V-Series functionality name change to FlexArray Virtualization 11 V-Series Support Matrix See Interoperability Matrix V-Series systems See LUNs (array) VCMDB LUNs caution about using 19 restricting visibility of 18 volume groups requirements for number of 39 VSP storage arrays required system parameters 25 Z zoning compatibility issues with HP EVA storage arrays 30 shared FC initiator port supported configuration 51