MultiPost-AP anchorage device



Similar documents
Söll GlideLoc Aluminium Ladders. Vertical fall protection system Certified according to EN 353-1:2002 and CNB/P/11.073

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions

Guide rail bracket (for adjustable heads)

Technical handbook Panel Anchoring System

SCAFFOLDING PRODUCT TECHNICAL GUIDE. Scaffold Couplers General Technical and Application Manual. Genuine Safety. Outstanding Service.


3. Geberit Pluvia Roof Drainage Systems

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249

Geberit Pluvia. Syphonic roof drainage system. Overview Page 42. Geberit Pluvia outlets 6 l. Geberit Pluvia outlets 14 l

HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast prestressed hollow core slabs

KIRÁLY TRADING KFT H-1151 Budapest Mogyoród útja tel: Clamps Clamping devices

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

HORIZONTAL INSTALLATION

Super Slider ADJUSTABLE FROM Model #HD26229

Description. Outlets Page 62. Contact foil Page 65. Accessories Page 65. Outlets Page 68. Accessories Page 69. Brackets Page 73.

Worldwide network in over 40 countries.

CLEAR-DIVISIONS CENTERFOLD

Operations and Instruction Manual Might Swivel - Part # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn

Removable Aluminium posts

Sliding and Folding Door Fittings Sliding Door Accessories

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

Linkeo 19" freestanding cabinets

CLEAR-DIVISIONS APERTO

HOSE, TUBE, AND PIPE CLAMPS

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

12.1 Schlüter -KERDI-BOARD

Saferand easierinstallation

WOLFFKRAN. 1 Schedule drawing. 1.1 Schedule drawing, WOLFF clear. max. hook height above ground. Data WOLFF clear

How to secure your property after a disaster

Pipe Clamps and Accessories

PART E SPECIFICATIONS

Product Catalogue HW-B150H

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

lindab duct suspension & support system Duct suspensions & Support systems

Terminal Boxes Series 8146

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

CLEAR-DIVISIONS VARIOFOLD

The Work at Height Safety Association. Guidance on inspecting eyebolts used for personal fall protection purposes

Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

FAG Hydraulic nuts. Technical Product Information

Mechanical arms, belts and sheets

ANTENNA PARTS CATALOG

1.1 DIMENSIONS AND WEIGHT PAG LOAD CENTRE FOR LIFTING PAG STORAGE CONDITIONS PAG. 2

POLE MOUNT SYSTEM-3 INSTALLATION

Les Produits MURPHCO Ltée

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

HALFEN NATURAL STONE SUPPORT SYSTEMS

HVU with HAS/HAS-E rod adhesive anchor

3-Component Measuring System

SQUARE TRUSS: 2' long square truss SUPPORT BARS:

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Drive shaft, servicing

Cable Trays Technical Instructions & Specifications

Connection Solutions

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Knürr Smaract. Knürr Smaract. CompactRack

Fire Barrier Duct Wrap 15A

Preface nivtec.com 3

Operating Instructions Drill rig DRU160

Lift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge...

INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED

Quality power tools since 1919 NEW GENERATION. Stirrers and mixing stations

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities

lindab duct suspension & support system Duct suspensions & Support systems

Residential Deck Safety, Construction, and Repair

Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille

Machine Screws, Dowel Pins and Hardware

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

1000/14.02 KOBSERT. Thread inserts for metals

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Thermal Performance of Steel Beam Junctions using Different Connection Methods

Pipe Cutting and Beveling Clamshells

INSTALLATION. General. Important Note. Design. Transport

RTD Temperature Probe for the Food/Pharmaceutical Industry

SIGRAFLEX . Properties. Applications

Chapter 10 - Scaffolding Systems

Fixturing systems Fixturing systems for measurement technology

INSTRUCTIONS FOR USE

Fredriksons conveyor systems handle goods with a width from 20 mm up to 600 mm.

CAPACITIVE LEVEL METERS CLM 36

Product classification

Cable Installation Accessories. Cable Hoisting and Attachment. Snap-In Hangers. SnapStak Hangers

SECTION PIPE HANGERS AND SUPPORTS

Repairing storm damaged roofs

CABLE SUPPORT SYSTEMS

HSL-3 Heavy duty anchor carbon steel. Anchor Fastening Technology Manual HSL-3. Heavy duty anchor. Version /

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

During severe flood events, such as those

Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001

SAFETY FENCES, SAFETY BARRIERS AND PEDESTRIAN GUARDRAILS

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

F-Series Camera Mounting Accessories

Transcription:

MultiPost-AP anchorage device MultiPost anchorage point Type 1 Fixing on reinforced concrete with large, 360 rotating stainless steel lifting eye for the simultaneous securing of max. 2 persons. This can also be used as a fall indicator. Tested to DIN EN 795 Class A, B. L Weight Part No. for fixing pin M 16 250 6,5 kg 23757 350 9,4 kg 23792 450 11,7 kg 23793 for fixing pin M 12 250 6,5 kg 23794 350 9,4 kg 23795 450 11,7 kg 23796 L 250 mm L 350 mm L 450 mm Installation on reinforced concrete by means of pins approved by building regulatory authorities for use in reinforced concrete (not included in delivery). Minimum ceiling thickness "d" and distances from edge "a r " according to pin approval. I 1

MultiPost-AP anchorage device MultiPost anchorage point Type 2 Fixing on steel girders with large, 360 rotating stainless steel lifting eye for the simultaneous securing of max. 2 persons. This can also be used as a fall indicator. Tested to DIN EN 795 Class A, B. For girder width b: 80 175 mm Max. clamping height h: 930 mm Complete with fixing accessories. Please state clamping height h when ordering. L = 250 mm Weight: 14,7 kg Part No. 23847 L = 350 mm Weight: 15,7 kg Part No. 23848 L = 450 mm Weight: 16,7 kg Part No. 23849 Installation on steel girders and lightweight concrete ceilings. I 2

MultiPost-AP anchorage device MultiPost anchorage point Type 3 Fixing on wooden beams with large, 360 rotating stainless steel lifting eye for the simultaneous securing of max. 2 persons. This can also be used as a fall indicator. Tested to DIN EN 795 Class A, B. For beam width b: 80 150 mm Max. thickness of roof boards d: 32 mm Complete with fixing accessories. Please state beam width b when ordering. L = 250 mm Weight: 12,2 kg Part No. 23850 L = 350 mm Weight: 13,2 kg Part No. 23851 L = 450 mm Weight: 14,3 kg Part No. 23852 Installation on wooden beams and roof boards. I 3

MultiPost anchorage device MultiPost universal support Type 1 Fixing on reinforced concrete tested to DIN EN 795, permitted load 15 kn. For fixing horizontal anchorage devices. Support height 250, 350 or 450 mm. L Weight Part No. for fixing pin M 16 250 6,3 kg 23767 L 250 mm 350 9,2 kg 23791 450 11,5 kg 23797 for fixing pin M 12 250 6,3 kg 23798 350 9,2 kg 23799 450 11,5 kg 23800 L 350 mm L 450 mm Xenon system on MultiPost. Installation on reinforced concrete by means of pins approved by building regulatory authorities for use in reinforced concrete (not included in delivery). Minimum ceiling thickness "d" and distances from edge "a" according to pin approval. I 4

MultiPost anchorage device MultiPost universal support Type 2 Fixing on steel girders tested to DIN EN 795, permitted load up to 15 kn. For fixing horizontal anchorage devices. For girder width b: 80 175 mm Max. clamping height h: 930 mm Complete with fixing accessories. Please state clamping height h when ordering. L = 250 mm Weight: 14,5 kg Part No. 23775 L = 350 mm Weight: 15,5 kg Part No. 23776 L = 450 mm Weight: 16,5 kg Part No. 23777 MultiRail system on MultiPost. Installation on steel girders and lightweight concrete ceilings. I 5

MultiPost anchorage device MultiPost universal support Type 3 Fixing on wooden beams tested to DIN EN 795, permitted load up to 15 kn. For fixing horizontal anchorage devices. For beam width b: 80 150 mm Max. thickness of roof boards d: 32 mm Complete with fixing accessories. Please state beam width b when ordering. L = 250 mm Weight: 12,0 kg Part No. 23783 L = 350 mm Weight: 13,0 kg Part No. 23784 L = 450 mm Weight: 14,1 kg Part No. 23785 Guide rail horizontal on MultiPost. Installation on wooden beams and roof boards. I 6

MultiPost anchorage device Anchorage ring Tested only together with the MultiPost according to EN 795 (Class C). Tensile strength = 22.5kN, max tolerable load = 15kN, thread M 12. When using MultiPost as end fixing point for Xenon, than this anchorage ring must be used. Supplied with the required washers. Stainless steel To be used with MultiPost without thermal insulation Weight: 0,18 kg Part No. 23769 To be used with MultiPost with thermal insulation Weight: 0,19 kg Part No. 23811 Thermal insulation set For MultiPost Anchorage Points and universal post for permanent installation. All necessary accessories for Anchorage Device, Multi- Rail-bracket or Xenon-bracket are included, and are compatible with the most commonly used insulation systems. PE, Insulation material: Mineral wool, PU for MutiPost L=450 mm Weight: 1,3 kg Part No. 23813 Special length upon request Factory-fitting on MultiPost Part No. 23817 Example of use (right) MultiPost AP with thermal insulation on concrete covering. Sealing by adhesive flange (not included in delivery). I 7

Anchorage points Söll-RAP Removable Anchorage Point A new removable anchorage device which complies with EN 795, Class A. Approved to be used by two persons contemporarily. The anchor eyebolt can be removed and reinserted into the anchor socket. It can only be released by the user pressing the unlocking button. The eyebolt can swivel ensuring the user can be safely connected in any position. Both eyebolt and socket are made from stainless steel. The anchor socket should be fixed with chemical adhesive appropriate for the substrate. SÖLL-RAP Swivel eye bolt Weight: 0,2 kg Part No. 23876 SÖLL-RAP Basic anchors stainless steel 316Ti Supplied with white plastic socket cap 23875 100 mm 0,2 kg 23951 125 mm 0,3 kg 23952 200 mm 0,4 kg 23953 250 mm 0,5 kg SÖLL-RAP Stainless steel plate 316Ti For fixing into soffit above a suspended ceiling Weight: 0,4 kg Part No. 23955 Threaded bolt M16 including nuts and washers 24042 330 mm 0,2 kg 24041 660 mm 0,2 kg 24040 1000 mm 0,3 kg SÖLL-RAP Stainless steel angle 316Ti For fixing to walls above a suspended ceiling Weight: 0,5 kg Part No. 23954 I 8

Anchorage points SÖLL-RAP Example of use SÖLL-WAP Wall Anchorage Point A single anchor point, with integral fall indicator, which complies with EN795, Class A. Approved for 1 person, can be fixed to structural steel or non-cracked structural concrete (minimum thickness 165mm) The fall indicator will activate at 3.5kN. The delivery includes the wall eyelet, the fixing elements as well as a compound anchor cartridge. The instruction sheet included must be observed accurately. SÖLL-WAP Wall anchorage point Weight: 0,14 kg Part No. 23948 I 9

Anchorage points Safety ring tested i.a. w. DIN EN 795 - class A.1. Min. mast diameter 60 mm. max. mast diameter 1.300 mm. Complete with all fitting elements. When ordering please state size of segment (90, 180, 270 or 360 ) and exact mast diameter. Weight: depending on dimensions Part No. SR-<segment size>-<ø in mm> Söll-Map mast anchoring point: Clip with eye. tested i.a. w. DIN EN 795 - class A.1. Min. mast diameter 60 mm. max. mast diameter 300 mm. Complete with all fitting elements. When ordering please state exact mast diameter. Weight: depending on dimensions Part No. BS-OESE-<Ø in mm> I 10

Anchorage points Söll T-Anchor - Anchorage points tested i.a. w. DIN EN 795 - class A, admitted for the concurrent use by 2 people. On sufficient load-carrying capacity of the subsoil is to pay attention. Weight: 1,46 kg/each Part No. 24787 Stainless steel, pickled Weight: 1,46 kg/each Part No. 24788 01.2011 I 11