MFT MultiFlex (MDU) Amplifier



Similar documents
Model GS Port Node 1 GHz with 40/52 MHz split

Compact EGC Amplifier Model 93251

AC3200 INTELLIGENT BROADBAND AMPLIFIER

MATRIX TECHNICAL NOTES

More Power for Your Distribution Team

Table of Contents. Cableoptics Nodes Broadband Telecommunications Multi-Optic Node [BTN-M-75SH/*] FEATURES

Transponder for GainMaker Amplifiers

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Channel Bandwidth, MHz. Symbol Rate, Msym/sec

DVT913 TV CHANNEL CONVERTER

LT-82 Stationary IR Transmitter

Light Link Series 2 LT1550. Laser Transmitter with Erbium Doped Fibre Amplifier. Description. Features

DISCRETE SEMICONDUCTORS DATA SHEET M3D848. CGD MHz, 20 db gain power doubler amplifier. Product specification 2002 Oct 08

DIRECTV MFH2 Single Wire Satellite Distribution System

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Broadband Telecommunications Drop Amplifier

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

Applications. Key Features. Benefits. Contact us. Solution for TETRA coverage. AIR Repeater TETRA / TETRAPOL 400 RF/RF

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS khz

HDO700 P FIBRE OPTIC TRANSMITTER

RF Communication System. EE 172 Systems Group Presentation

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere

SECTION TELECOMMUNICATIONS ACCEPTANCE TESTING

LAP NODO ÓPTICO 4 SALIDAS INDEPENDIENTES OWS860G-S

LAP NODO ÓPTICO 2/4 SALIDAS WT-8604JL

RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc.

Calculating Antenna System Return Loss As Viewed Through The RF Path

Guide. Installation. Signal Booster. Wilson. In-Building Wireless Smart Technology Signal Booster. Contents:

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

DSA800 Series Spectrum Analyzer

Cisco Cable Radio Frequency (RF) FAQs

TUBE-TECH HLT 2A Stereo High- and Low shelving, T- filter & Low- and High cut

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Features, Benefits, and Operation

Impedance 50 (75 connectors via adapters)

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

LM1596 LM1496 Balanced Modulator-Demodulator

CINEMA SB100 powered soundbar speaker

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

IVIS IVIS - Indoor Video Insertion System

FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS. drm TesT equipment

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Propagation Channel Emulator ECP_V3

TOA 900 SERIES II MIXER POWER AMPLIFIER

DC to 30GHz Broadband MMIC Low-Power Amplifier

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

Kit Watt Audio Amplifier

ACT4077 Driver for MACAIR A3818, A5690, A5232, A4905 & MIL-STD-1553

HD Radio FM Transmission System Specifications Rev. F August 24, 2011

MISE - STEREO ENCODER

Current Probes. User Manual

0HDVXULQJWKHHOHFWULFDOSHUIRUPDQFH FKDUDFWHULVWLFVRI5),)DQGPLFURZDYHVLJQDO SURFHVVLQJFRPSRQHQWV

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

BLACK BOX Scalable matrix KVM switch supports up to 1024 ports with fiber or copper cable.

Delaware Valley SCTE Comparing RF-over-Glass to HFC. Bill Dawson VP Business Development ARRIS Access & Transport bill.dawson@arrisi.

CX380X Advanced Spectrum and Burst QAM Analyzer

Network analyzer and spectrum analyzer two in one

Divvela.Santhosh Raghava Rao [1],Sreevardhan cheerla [2]

Blue Point Engineering

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Wideband USB Synthesized Signal Generator. Dynamic range 70 db, output power from -60dBm to +10dBm in 0.25dB steps

Cable 101. A Broadband Telecommunications Primer for Non-technical Personnel

Design and Certification of ASH Radio Systems for Japan

Applications. Key Features. Benefits. Contact us. Solution for TETRA coverage. AIR Repeater TETRA RF/RF High Single

VDI Mixer/Amplifier/Multiplier Chains (MixAMCs)

Achieving New Levels of Channel Density in Downstream Cable Transmitter Systems: RF DACs Deliver Smaller Size and Lower Power Consumption

Optimizing IP3 and ACPR Measurements

RF Video Distribution System. Why Z-Band is The Right Choice for Quality Video

QuickSpecs. HP Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview

Agilent 8753ET/8753ES Network Analyzers

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

ANTENNA DISTRIBUTION SYSTEM USER'S GUIDE

24 GHz Point-to-Point 1.4+ Gbps Radio. Datasheet. Model: AF24. High Performance Wireless Backhaul. Long Range of 13+ km

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

2 Ohm Nominal Coaxial Speaker OWNER S MANUAL

How To Define Hfc Technology

MANUAL FOR RX700 LR and NR

PSM 900 and PSM 1000 Personal Monitor Systems TWO SYSTEMS. INFINITE POSSIBILITIES.

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Introduction. All the WMS4500 systems in this document are designed with active antennas that can be used in all venues with a 20m RG58 antenna cable.

A Low Frequency Adapter for your Vector Network Analyzer (VNA)

iva Cable & Antenna Analyzer

INSTRUCTION FOR COMPLETING COMPETITIVE SOLICITATION ACKNOWLEDGEMENT FORMS

US-Key New generation of High performances Ultrasonic device

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

Ideal for high dynamic range measurements from compression to noise floor

E-Option Multi-taps Conditioning at the Tap

Lynx Broadband Installation Manual for Residential Packages with a 20 db Amp Quick Start Guide (first two pages)

Advanced Power over Ethernet Controllers. Datasheet. Models: TS-5-POE, TS-8-PRO, TS-16-CARRIER. Gigabit PoE Ports. Intuitive Configuration Interface

PD Power Bandwidth- Worst Case Analysis July 2008

Analog Set-Top Terminals Interactive Programmable Baseband Addressable Terminal [CFT-2200] FEATURES

SATELLITE TV on fiber

Application. Key Features. Benefits. Contact us. Solution for Digital TV coverage. Multi DVB-T/-H/-T2 - & ISDB-T Gapfiller Nx1W

USB Smart Power Sensor

The cost and performance benefits of 80 GHz links compared to short-haul GHz licensed frequency band products

328 Innovation Blvd. 1 Wheaton Road, Witham

Differential Charge Amplifier

Transcription:

MFT MultiFlex (MDU) mplifier The CI Communications MultiFlex mplifier is specifically designed for use in vertical mount applications. It is ideal for apartment complexes or business high-rise situations. The MultiFlex is a state-of-the-art, bi-directional amplifier offered as an indoor (UL, CUL & CE listed) mains powered (90-240 VC) or an outdoor cable powered (40-90 VC) amplifier. It can be ordered with forward bandwidths of 750, 870, or 900 MHz. vailable operational gains are 37 db @ 750 MHz, 37 or 40 db @ 870 or 900 MHz. Reverse bandwidths are available in 5-40, 5-42, 5-55 & 5-65 MHz with a gain of 19 db, 24 db or with jumper for passive reverse. djustments for forward/reverse gain, input/output levels, and slope control are easily configured to all application through optional plug-in attenuators and equalizers. directional coupler test points are provided in the forward path at both the input and output with separate test points in the reverse path. The amplifier is housed in a finned aluminum die-cast housing for superior heat dissipation. Mounting is accomplished using easily accessible external tabs allowing a variety of placements in vented lock boxes or pedestals. RF connections are made through high performance SCTE compliant F type cable or 5/8 standard hard-line type cable connectors allowing the flexibility to place the unit on any type of cable. Page 1 of 6

Reverse Gain 19 or 24 db Forward Input Reverse Output H L MFT Multiple Dwelling mplifier Block Diagram Net Pad EQ 1 Pad Board EQ 2 H L EQ Pad LPF Pad Notes 1. Forward gain stated at 750, 870 or 900 MHz. Reverse gain stated at 40 MHz. Forward Output Reverse Input Forward Gain 37 db @ 750 MHz 40 or 37 db @ 870 MHz 40 or 37 db @ 900 MHz Page 2 of 6

MultiFlex Standard mplifier CI Communications, Inc. MFT 750 / 870 / 900 MHz Notes Part Number Hybrid Return 1 MFT7/37PCS _ MFT8/37PCS _ MFT8/40PCS _ MFT9/37PCS _ MFT9/40PCS _ RT24HY-065 RT30HY-065 Bandwidth (MHz) 2, 3 750 870 870 900 900 See notes Station flatness 4 ±0.5 ±0.5 Gain (db) 5 37.0 37.0 40.0 37.0 40.0 19.0 24.0 Slope (db) 4 0 ±1.0 0 ±1 Return loss (db) worst case 4 16.0 16.0 RF test point (db) Distortions Worst Case -20.0 ±1.0-20.0 ±1.0 Channel loading 6, 12 79 6 Rated output level (dbmv) 6 41/51 35 Rated output slope (db) 6 10.0 ±1.0 0 Composite Triple Beat CTB (-dbc) 7 67.0 68.0 68.0 67.0 67.0 80.0 Composite Second Order CSO (-dbc) high side 7 68.0 79.0 79.0 75.0 75.0 79.0 Cross Modulation XMOD (-dbc) 8 61.0 67.0 67.0 62.0 62.0 72.0 Noise figure (db) 9 8.5 8.5 8.5 8.5 8.5 9.0 Groupt Delay (ns) Forward (n + 3.58 MHz) worst case 10 30.0 Reverse (n + 1.5 MHz) worst case 10 36.0 Surge protection (kv) 11 6 Power Requirements (With ctive Reverse Path) Units Mains powered (90-240 VC) W 24.1 (Max) Cable powered (40-90 VC) W 25.1 (Max) Current Draw (With ctive Reverse path) 40-90 VC only Input Ranges (Selectable) Units 40-90 @ 40 VC 0.82 @ 50 VC 0.68 @ 60 VC 0.57 @ 70 VC 0.50 @ 80 VC 0.45 @ 90 VC 0.40 C Power Passing Limit - C by-pass current damage limit (amps) Cable powered (40-90 VC) only 10 PHYSICL Dimensions (L X W X H) in (cm) 13.00 X 9.25 X 2.75 (33.0 X 23.5 X 7.0) Weight lbs (kg) 7.9 (3.58) Notes 1. " _" In part number is for frequency split, reverse and power cord set options. 2. Maximum bandwidth freqency depends on the reverse frequency split. 3. Lower bandwidth frequency of chosen split. 4. Single station measured with all forward and reverse pads and equalizers with 0 db values. 5. Typical operating gain is measured with equalizers in all forward locations and 0 db pads. 6. Standard channels flat per NCT test methods, or sloped as indicated by rated output slope. 7. Worst case as measured on matrix distortion analyzer utilizing CW carrier. 8. Worst case as measured on matrix distortion analyzer utilizing a 15.75 KHz square wave and measured to nearest db. 9. Single station measured with 0 db pads and equalizers. For system calculations add 1 db for equalizer loss and 1 db loss for diplex filters and test points. 10. Worst case group delay measurements are for 42/53 subsplit only, for different splits contact CI. 11. 6 KV surge protection standard for line powered units. For cable powered units, 6 KV surge protection requires installation of the optional plug-in sidactor (P/N 090491). 12. 550 MHz analog channel loading, 79 channels +200 MHz for 750 MHz, +320 MHz for 870 MHz, +350 MHz for 900 MHz, digital channel loading, 256 QM at -6 dbc relative to its associated visual carrier Confidential Information contained in this document is subject to change without notice Revision date: 1/13/2009 Page 3 of 6

Power cord Sets North merica 10 mp cord set w/c13 Connector 5.9 ft (1.8 m) long International / Europe 10 mp cord set w/c13 Connector 5.9 ft (1.8 m) long Japan 12 mp cord set w/c13 Connector 5.9 ft (1.8 m) long ustralia10 mp cord set w/c13 Connector 5.9 ft (1.8m) long rgentina10 mp cord set w/c13 Connector 5.9 ft (1.8m) long Page 4 of 6

Required ccessories The following accessories are required for operation. Forward all units - reverse if active Plug-in equalizers 1 Forward 1 Reverse Plug-in pad 1 Forward 1 Reverse TYPE PRT NUMBER RNGE (db) INCREMENTS (db) Forward CEQ750/XX 1.5 to 21.0 1.5 Forward CEQ870/XX 1.5 to 21.0 1.5 Forward EQD750/XX 0 to 25.5 1.5 Forward EQD870/XX 0 to 21.0 1.5 Reverse REQ42/XXB 0 to 12.0 1.5 Reverse EQD55/XX 0 to 12.0 1.0 Reverse REQ65/XXB 0 to 12.0 1.0 NOTE: For 900 MHz stations use the 870 MHz forward equalizers Optional ccessories (Sold separately) For 19 db reverse gain (P/N RT24HY-065) For 24 db reverse gain (P/N RT30HY-065) RF test probe (P/N 100685-01) Surge protect sidactor (P/N 090491 or 090689-01) ttenuator Pads ttenuators with short handles (SXPXXT) from 0 to 20.0 in 0.5 db increments ttenuators with long handles (SXLXX) from 0 to 20.0 in 0.5 db increments Ordering Information The MultiFlex can be ordered in a number of variations. Each is defined by a part number which specifies a certain combination of options. Page 5 of 6

MFT Configuration Sheet Customer: Created By: Order Date: ORDERING MTRIX November 10, 2009 Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 PRT NUMBER M F T -- 1-2-3 4 6-7 8 9 M F T MODEL 12 REVERSE GIN MFT = MultiFlex mplifier 1 = Passive reverse (Jumper) 6 = Hybrid reverse (19 db gain) BNDWIDTH 7 = Hybrid reverse (24 db gain) (see note 3) 7 = 750 MHz 8 = 870 MHz 13 POWERING 9 = 900 MHz 1 = Cable switch mode power supply (40-90 VC) FORWRD GIN 9 = Mains switch mode power supply 37 @ 750, 870 or 900 MHz (90-240 VC) 40 @ 870, or 900 MHz 15 POWER CORD SETS OR CUSTOM (see note 5) HYBRID TECHNOLOGY 0 = None P = GasFet Power Doubling 1 = North merica 2 = International / Europe STTION SLOPE (see note 4) 3 = Japan C = 0 db @ 750 & 870, 900 (standard) 4 = ustralia D = 11 db @ 750 MHz & 12.9 db @ 870 MHz (only) 5 = rgentina = 14.5 db @ 900 MHz (only) X = Custom - (Determined by product management) 10-11 S FREQUENCY SPLIT (Reverse / Forward - MHz) S4 = Subsplit (42 / 53) S5 = Subsplit (55 / 70) S6 = Subsplit (65 / 85) S7 = Subsplit (40 / 50) (see note 2) NOTES: 1. For proper setup, due to 1002 MHz platform, use only an CI Communications test probe. (P/N 100685-01) 2. For S7 frequency split (40 / 50) use REQ42/XXB for reverse EQ. 3. 24 db reverse gain is not currently available on the 55/ 70 frequency split configuration. 4. Contact CI for distortion specifications other than standard 0 db of slope. 5. Positions 14 & 15 are not used in the cable powered (40-90 VC) part number. CCESSORIES: Required ccessories Optional ccessories (Sold separately) Forward all units - reverse if active For 19 db reverse gain (P/N RT24HY-065) Plug-in equalizers 1 Reverse 1 Forward For 24 db reverse gain (P/N RT30HY-065) Plug-in pad 1 Reverse 1 Forward RF test probe (P/N 100685-01) Surge protect sidactor (P/N 090491 or 090689-01) ttenuator Pads ttenuators (SXPXXT) or (SXPLXX) from 0 to 20 in.5 db increments CI Communications, Inc. reserves the right to discontinue the manufacture or change specifications without prior Page notice 6 of on 6 any parts illustrated in this data sheet. RevE 11-10-2009 CI Communications, Inc.