Technical Specification. Generating Set with Waukesha engine burning natural gas



Similar documents
4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

Diesel Engine Driven Generators Page 1 of 6

CAT CG132. Series Gas Generator Sets

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

300 Series PA Pump and Cooler Assemblies

Centro-Matic Automatic Lubrication Systems System Controls

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

Diesel Generating Set

C18 ACERT Fire Pump Tier bkw/ rpm

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

DIESEL GENERATOR SETS

3516 Industrial Engine

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

Magnum Mobile Generator MMG55 Specifications

Micro cogeneration. Affordable, efficient and innovative

Bergen Engines Products and Applications

Annex-A TECHNICAL SPECIFICATION

New 27 hp 2 Cylinder Liquid-Cooled Engine

HEAVY DUTY STORAGE GAS

T U R B I N E G A S M E T E R

WÄRTSILÄ 50DF PRODUCT GUIDE

How To Use A Cat Diesel Engine

Frequently Asked Questions Generators

3516B Offshore Generator Set

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Commercial Gas Furnace Upflow

Explosion-Proof Electric Unit Heaters

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK rpm

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

Specifications for Volkswagen Industrial Engine

Propane-Fueled Microturbine: Case Study

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

BHKW. Power. Power. Gas engines for CHP units and gensets. MAN Engines. A Division of MAN Truck & Bus

Electronic Flow Switches

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

Engine Power Plant 5,2 MW Stationary Dual Fuel (Diesel / Gas ) Engine (12 VDS 48/42 )

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Spark-ignited generator set

Auxiliary Power Unit (APU) for Military Vehicles

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

(ui. C) Listed by Underwriters' Laboratories of Canada. 6BTA5.9 F1 LISTED AGENCY RATINGS

October 8, WHP Waste Heat-to-Power Fuel and Emission Free Power

INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station

Gas Turbine Power COMPACT, EFFICIENT, RELIABLE

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

WÄRTSILÄ 34DF PRODUCT GUIDE

A Single Source for all Power System Solutions

Dual Fuel Medium Speed Product. Presenter Name Date

Diagnostic Fault Codes For Cummins Engines

HERZ-Thermal Actuators

Why and How we Use Capacity Control

TMS TANK MANAGEMENT SYSTEM

THM Gas Turbines Heavy duty gas turbines for industrial applications

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Cooling Capacity CFM in. w.c. (125 Pa)

HVAC Processes. Lecture 7

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

4 Posiflow Proportional Solenoid Valves

STANDBY 3200 ekw 4000 kva 50 Hz 1500 rpm Volts

Medical Air Systems: Scroll

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

In-Line Electronic Flow Switches

Marine Generating Sets 3.7 to 50 kva

Sanitary Type Electronic Flow Switches

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines

912. The engine for construction equipment.

MP-4000 Alarm List (Software version or later)

Technical data. Danfoss DHP-A

WÄRTSILÄ GAS POWER PLANTS BENEFITS: Maintenance schedule independent of the number of starts, stops or trips. Net plant electrical efficiency over 52%

MEMBRANE VACUUM MINI PUMPS

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

ECOCIAT. Domestic hot water heat recovery unit

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

3516B Offshore Emergency Generator Set

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Continuous flow direct water heating for potable hot water

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Backup Fuel Oil System Decommissioning & Restoration Plan

TYPE APPROVAL CERTIFICATION SCHEME MASS PRODUCED DIESEL ENGINES

1013 E. The engine for agricultural equipment.

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

Fire Pump Plan Review March 2010

Transcription:

Technical Specification Generating Set with Waukesha engine burning natural gas

The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the GEGS you receive the following benefits: * Optimized electrical efficiency for nominal power by providing a single customer circuit inlet with temperature of up to 80 C (170 F). * Includes ECP8000E genset control panel optimized for applications. * Compact design of GEGS enable easy containerized or building housing and easy maintenance during the operation. GENERAL 16V150LTD GAS ENGINE DATA Cylinder: V 16 Piston Displacement: 48L (2924 cu.in.) Bore & Stroke: 152 x 165 mm (5.98 x 6.5 ) Jacket Water System Capacity: 159L (42 gal.) Lube Oil Capacity: 820 L (215 gal.) Starting System: 8.5 10 bar (125 150 psi) air/gas 24 VDC electric Dry Weight: 7730 kg (17,000 lb. ) Gas Engine Performance Data Engine Model 100% 85% 77% 16V150LTD IC temperature C 54 54 54 JW temperature C 99 99 99 Carb setting Timing BTDC Site Conditions Fuel WKI 99.21 99.21 99.21 Fuel LHV MJ/m 3 34.74 34.74 34.74 Ambient C 37 37 37 Altitude meters 85 85 85 Engine Performance Power kwb 1036 882 804 Speed RPM 1500 1500 1500 BSFC (LHV) (tolerance +5%) kj/kwh 8494 8659 8765 Induction Air Nm 3 /hr 3959 3394 3114 Exhaust Flow kg/hr 5406 4636 4255 Exhaust Temp C 385 404 414 2

Heat to kw Jacket Water 376 320 291 Lube Oil 139 129 124 First Stage Intercooler 136 95 78 Second Stage Intercooler 74 62 57 Total Exhaust 614 559 528 Radiation 69 74 76 Emission mg/nm 3 NOx 500 500 500 CO 750 800 800 NMHC 180 200 200 Ignition timing and Carb Setting determined by based on load, speed, Desired NOx, O2 Offset, and WKI(TM). O2 Offset may need to be adjusted in ESP to meet emissions at different operating points. Configuration includes a unit mounted heat exchanger to combine jacket water, lube oil, and first stage intercooler into one circuit with an estimated combined heat of 652 kw based on a water inlet temperature 75 C. BSFC is stated in lower heating value (LHV).NOx emission at absolute humidity of 10.71 g H2O/kg of dry air. Fuel must comply with the Gaseous Fuel Specification in effect at the time of approval. All data is based on 500 mg/nm3 Nox calibration. Maximum allowed normal oil header temperature is 88C. Extended operation below 75% load is not recommended. Increased maintenance and oil change intervals will result if running at loads below 75% load for extended periods of time. Lube oil change intervals may be shorter due to increased jacket water temperatures. Gas Engine Specification: Flex connections [1000A] Includes(1) fuel, (1) exhaust, (2) jacket water (HT), and (2) auxiliary water (HT) flexes. For isolator mount installations. APG1000 CHP Configuration [1002] Increases thermal efficiency from 38.2% to 44.6% (50 Hz) and 40.9% to 47.6%(60 Hz). [2071] Thermally released gas train shutoff valve for APG1000 CHP configuration on natural gas. High Efficiency Generator [3000] Increase generator efficiency from 96.5% tp 96.9% at 50 Hz and 96.2% to 96.8% at 60 Hz. Generator Space Heater [3021] 230V AC, single phase, 50/60 Hz. Automatically disconnected when engine is running, wiring brought to AC junction box. 3

Winding Temperature and Generator Bearing Temperature Detector [3068] 100 ohm platinum resistive temperature detector (RTD), with a temperature coefficient of 0.00385 ohms/ohm/ C, one per phase, total of three, and one bearing. Includes 25 ft (7.6 m) customer interface harness. Waukesha MICROSPIN Oil Filtration System [5112A] MICROSPIN centrifugal bypass oil filter with shutoff valve. Oil Level Regulator and Quick Fill Valve [5200B] Kenco oil level regulator. Quick fill mounted and piped to regulator. Lubrication Oil Heater [5206A] 2,500 watt heating element. Thermostatically controlled (100 F on; 120 F off). Engine mounted, designed for indoor duty. Continuous prelube not available. Pump motor: 24V DC. controlled. Level Switches [6112] Low lube oil level warning and shutdown and high lube oil level warning switches, 24V DC, 2 amps. Includes 25 ft (7.6 m) customer interface harness. Note: Heat exchanger cooled units include low water warning and shutdown for jacket and auxiliary circuits. Shipped with surge tank assembly. Exhaust Thermocouples [6205] Type K, (18 total), individual cylinders plus (1) pre turbine and (1) post turbine. Main bearing thermocouples, Type K, (9 total). Includes 25 ft (7.6 m) customer interface harness. Additional Sensors [6210] Pressure senders for jacket water and fuel pressure. Temperature senders for auxiliary water inlet and fuel gas. Vibration transducers Two (2) sensing elements, engine and generator. Includes 25 ft (7.6 m) customer interface harness. Vibration Isolators [ 9509B] Spring type. Requires longer flex connections (not supplied). GENERATOR LEROY SOMER LS541 VL12 DATA: Generator Specification please see the enclosure. 4

SINGLE/MULTIPLE UNIT CONTROL FOR PARALLELING The Model ECP8000E panel consists of one free standing steel enc losure for controlling single or multiple units in parallel. Panel dimensions: 764mm x 459mm x 1830mm (30"W x 18"D x 72"H). Rated for indoor use: operating temperature 20 C to +70 C ( 4 F to +158 F), relative humidity 0 95% (noncondensing). The HMI (Human Machine Interface), control switches and indicating lights are mounted through the hinged door. Technical parameters of gas Kind of gas Natural gas Calorific value min. 31 MJ/Nm 3 Methan contents (CH 4 ) ca. 97,8 % capacity Ethane, Propane, Butane Nitrogen (N 2 ) Carbon dioxide (CO 2 ) and other ca. 1 % capacity ca. 1 % capacity ca. 0,2 % capacity BASIC SPECIFICATION for GDGS APG1000 type Generating Set type APG1000 Fuel Natural gas Rotational speed (50Hz) rpm 1500 Nominal shaft power kw m 1 036 / engine Electric efficiency of generator (cos φ = 1) % 96,9 Voltage of generator V 400 Frequency Hz 50 5

Mechanical output of GEGS kw m 1036 Electrical output of GEGS (for cos φ = 1) kw e 1004 Mechanical efficiency on engine shaft (+5% of tolerance) % 42,4 Electrical efficiency ( +5% of tolerance) % 41,1 Energy input kw 2359 Heat Rate (tolerance +5%) kj/kwh m 8 494 Heat Rate on generator shaft (tolerance +5%) kj/kwh e 8 765 Engine fuel consumption / hour for LHV=34,74 Nm 3 /h 245 Technical guarantee and servicing The manufacturer provides a technical guarantee for a period of 12 months counting from the final acceptance test of the power respectively 18 months from notification of readiness for dispatch of the Unit GDGS, which occurs first. 6

All random events are fully covered by our company and at its expense within the guarantee period provided that, the engine operation will be according with Manual Instruction. Following the technical guarantee support, we can offer a complete post warranty service package. Enclosure: 1/APG (Advanced Power Generation) Gas ENGINATOR 2/ Generator Specification 3/EPC8000E Enginator Control Panel 7