WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!



Similar documents
Example. Fluid Power. Circuits

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

Rexroth Hydraulic Pump A10VO Series User Manual

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

The Secret of Hydraulic Schematics. BTPHydraulics

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

Unit 24: Applications of Pneumatics and Hydraulics

ACCUMULATOR INSTALLATION

COUNTERBALANCE VALVES

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Oil and Coolant Circulating Heating System. Model - OCSM

NITROUS TRANSFER PUMP INSTRUCTIONS

Hydraulic Accumulators Introduction. Page Accumulator Selection Guide. Design Features and Construction. Charging Valve.

MODEL G300 BRAKE BLEEDER

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

I. Introduction. 10 minutes

Quiz On Information Learned From Chapter 1

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

Hydraulic Troubleshooting PRESENTED BY

Hydraulic Trouble Shooting

Chapter 7 Hydraulic System Troubleshooting

STEERING SYSTEM - POWER

Occupational Health Program Safety Training Series. Lockout/Tagout Safety Awareness Training

SIMPLIFIED VALVE CIRCUIT GUIDE

PART 2 FORKLIFT HYDRAULIC SYSTEM

15CI and 25CI Reversing Motor Pumpset Owner's Manual

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Unit 24: Applications of Pneumatics and Hydraulics

PRESSURE REDUCING CONTROL VALVE

Fluid Power Formula. These Formula Cover All Fluid Power Applications In This Manual

Auto-belay Cable Replacement Process

Class 5 to 7 Truck and Bus Hydraulic Brake System

Lockout - Tagout. Control of Hazardous Energy OSHA Standard

SIMPLIFIED VALVE CIRCUIT GUIDE

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

MODEL T200-F18 MODEL T125-F18 Finish Nailers

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

hance the application of specific components, such as pumps, motors, accumulators, filters, and airline lubricators.

PC1130 Electric Air Compressor

INGROUND, ROPED, AND HOLELESS JACK SEAL REPLACEMENT

BRAKE SYSTEM OVERVIEW AND OPERATION PROCESS 1. BRAKE SYSTEM GENERAL INFORMATION 1) DESCRIPTION AND OPERATION 16-3.

PBX Series Quick Fit Connector Bimetallic Steam Traps

1000-LB. TRAILER JACK OWNER S MANUAL

FILLING AND PURGING THE SYSTEM

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Unit: mm(in) Item Standard value Service limit Axle shaft run out - 0.2(0.008)

PC1131 Electric Air Compressor

Sport Ice Elektro 124

MP-4V Heavy Duty Riveter / 39048

HYDRAULIC TABLE CART 500-LB.

Compressed Gas Cylinder Safety

Hydraulic control unit series

Kobelco Extended Warranty Program.

Trouble Shooting Tech Tips Operation

Compressed Gas Cylinder Program

Basic Symbols. Lines. Circular. Square. Diamond. Miscellaneous Symbols. -continuous line - flow line. -dashed line - pilot, drain

2 HP / 4 GALLON AIR COMPRESSOR OWNER'S MANUAL

Fuel Injection Pump, Rotary ( )

Professional Precharged Hunting Rifle

OCTOPUS SELECTION & INSTALLATION GUIDE

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

Morrison Bros. Co. General Product Specifications

Citation 1 Item 1a. #22: Struck by Inspection #

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Pressure Relief and Regulating Valves

VOYAGER 570G. 744A Sprayer Control

Owner s Manual. Models: 2S5P & 3S5P OPERATION AND MAINTENANCE OF SELF-PRIMING CENTRIFUGAL TRASH PUMPS PEDESTAL DRIVE

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

2006 HEADSHOK Service Video #1

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

HYDRAULIC CIRCUIT DESIGN AND ANALYSIS

3620 W 11th Streetб Houston, TX Telephone: sales@kellogg-american.com Website:

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

7600 SAND STREET, FORT WORTH, TX

Operating Instructions Parts List Manual Scissor Lift Pallet Truck

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Diesel Fuel Systems. Injection Nozzles

Series Hose Reels

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

BLADDER SURGE CONTROL SYSTEM

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

Stainless Steel Single and Dual Circulation Kits

FLUSHOMETER - TANK SYSTEM

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Cooling system components, servicing

SunMaxx Solar Filling Station Operating Instructions

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Unit 24: Applications of Pneumatics and Hydraulics

HPU14M-DS 2013 Daniels Manufacturing Corp., All Rights Reserved Page 1 of 17 REV. C 7/2013

Oregon Fuel Injection

Transcription:

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU! Atlanta (Monroe) GA 770-267-3787 gpm@gpmhydraulic.com www.gpmhydraulic.com

What You Don t Know About Hydraulic Accumulators Can Kill You TABLE OF CONTENTS Accumulator Function and Dangers of Pre-Charging with Oxygen 1 Safety Procedure for Pre-Charging an Accumulator 2-4 Checking the Pre-Charge Hydraulically and Proper Gauge Location 4, 5 Operation of the Piston Accumulator 5-8 Maintenance Safety Procedures of Removing the Piston 9 Operation of the Bladder Accumulator 10-11 Maintenance Safety Procedures for Removing and Replacing the Bladder 11-13 Accumulator Dump Valves 14 16 Accumulator Safety Procedures When Working on or Around the Machine 17-18

Accumulators And Flow Controls Accumulators Hydraulic accumulators are used to store pressurized hydraulic fluid. The accumulator performs the same function in a hydraulic circuit that a capacitor does in an electrical circuit. Dry nitrogen is used to pre-charge one side of the accumulator. A piston or some type of rubber element (bladder or diaphragm) is used to separate the hydraulic fluid and the nitrogen. Accumulators primarily will perform two functions in the hydraulic circuit: 1) Supply additional oil flow to the system at a very fast rate. The accumulator amd pump volumes are combined together to rapidly cycle hydraulic cylnders. 2) Absorb shock. Hydraulic oil flows through the system at a rate of approximately 20 feet per second. When a cylinder piston bottoms out or a valve is rapidly closed, shock occurs in the system. Dry Nitrogen Dry nitrogen is used to pre-charge accumulators because it is an inert gas. Although any inert gas can be used, nitrogen is cheaper because it is more readily available. 78% of the earth s atmosphere is nitrogen, 21% oxygen, and 1% is made up of Argon and other gases. An inert gas will not react readily with other chemicals. Oxygen or compressed air should never be used to pre-charge an accumulator. As oxygen is compressed it heats up and can cause a fire or explosion when mixing with the hydraulic oil. Hydraulic Accumulator Maintenance & Safety Page 1

Charging the Accumulator with Nitrogen In order for the accumulator to deliver the right amount of oil, the nitrogen pre-charge pressure must be correct. A good rule of thumb is to pre-charge to half the maximum system pressure. In systems using pressure compensating pumps, the maximum system pressure is determined by the compensator setting. The relief valve setting determines maximum system pressure in fixed displacement pump circuits (see pg. 20). This rule of thumb applies only to accumulators used for volume. Accumulators used for shock require a different pre-charge and are discussed later in this section. In the example shown, the compensator setting determines the maximum system pressure. The accumulator pre-charge in this system should be ½ of 2000 PSI or 1000 PSI. To charge the accumulator, the pressure on the oil side should be bled down to 0 PSI. In the example circuit, valve No. 1 should be closed first, then valve No. 2 should be opened. If the hydraulic pump is turned off, valve No. 2 should still be opened allowing the oil pressure to drop to 0 PSI. Once the hydraulic pressure is bled to 0 PSI (Figure 1), the protective valve cover on top of the accumulator can be removed. The gauge and charging rig are then installed onto the accumulator gas valve. Page 2 Hydraulic Accumulator Maintenance & Safety

With the bleeder valve closed, turn the gas chuck handle clockwise. The pre-charge pressure should then be indicated on the pressure gauge. Cracking the bleeder valve open will relieve the nitrogen pressure to atmosphere if overcharged. Before charging a piston accumulator, bleed all the nitrogen off, as there may be oil build up on top of the piston due to bypassing(see pg. 12). To charge with nitrogen turn the gas chuck handle counterclockwise. To vent the pressure out of the charging assembly open and then re-close the bleeder valve. Connect the hose from the nitrogen bottle to the charging rig. Figure 1 Hydraulic Accumulator Maintenance & Safety Page 3

The bottles normally are originally pre-charged to 2200 PSI. With the nitrogen bottle gas valve closed, turn the gas chuck handle clockwise to depress the accumulator gas valve. Gradually open the valve on the nitrogen bottle. Set the regulator on the nitrogen bottle to the desired pressure. Close the nitrogen bottle gas valve when pre-charged to the proper pressure. After pre-charging, turn the gas chuck handle counterclockwise and open the bleeder valve to relieve the pressure in the hose. The hose and charging rig can now be removed. The accumulator gas valve cover should be replaced. Checking the Nitrogen Pre-charge Hydraulically Instead of attaching the charging rig for checking the pre-charge, a hydraulic method is available. When the pump is turned off, pressure is locked in the system. Page 4 Hydraulic Accumlator Maintenance & Safety

Open the No. 2 manual dump valve a small amount. The pressure in the system will slowly drop. The pressure will drop to a point, then rapidly 0 PSI. The pressure that it rapidly drops to 0 is the pre-charge pressure. Types of Accumulators Piston The piston accumulator is similar to a cylinder without the rod. The piston separates the nitrogen and oil. Piston types are usually used when larger accumulators are required. Although it can be mounted in any position, a vertical mounting is better. If mounted horizontal, the barrel will wear on the bottom side because of the weight of the piston and contamination. Hydraulic Accumulator Maintenance & Safety Page 5

In the example circuit, the pump is off and the ¼ hand valve is open. The nitrogen pre-charge pressure has forced the piston all the way to the bottom. Any oil in the accumulator is drained to tank through the ¼ dump valve. Page 6 Hydraulic Accumulator Maintenance & Safety

With the ¼ manual dump valve closed and the pump turned on, the pump volume will begin filling the accumulator. As the accumulator fills, the dry nitrogen is compressed. The pump will continue to fill and pressurize the accumulator until both the nitrogen and hydraulic pressures are 2000 PSI (pump compensator setting). At this point the accumulator is fully charged and the pump will compensate. Hydraulic Accumulator Maintenance & Safety Page 7

When the directional valve is energized in the A position, pressure in the system will drop. The pressure drops because it takes less than 2000 PSI to move the load. The dry nitrogen forces the oil out of the accumulator combining it with the pump volume. The oil is ported through the directional valve to move the load. When the cylinder piston fully bottoms out or the directional valve is de-energized the pump will again fill the accumulator. Page 8 Hydraulic Accumulator Maintenance & Safety

Bypassing Test and Piston Removal To check for bypassing and to inspect the piston, install the charging rig. For easy removal of the piston it should be forced to the top. The following procedures will accomplish this easily and safely. 1. With the pump on, open the No. 3 bleeder valve on the charging rig. The nitrogen should be forced out of the top of the piston and the nitrogen pressure should drop to 0 PSI. On most charging rigs, the bleeder valve can be removed and a hose put in its place to prevent an oil spill. 2. Close the No. 1 isolation valve. The pump can also be turned off at this time. 3. Open the ¼ manual dump valve (No. 2). Hydraulic pressure in the accumulator will bleed back to tank. The piston should remain at the top due to the friction of the seals. 4. Remove the charging rig and the top of the accumulator. A puller can then be attached to the piston for removal. Hydraulic Accumulator Maintenance & Safety Page 9

Bladder Accumulator The bladder accumulator uses a thick rubber type balloon as the device that separates the oil from the nitrogen. Drawing A shows the bladder filled with nitrogen (1000 PSI). The expanded bladder is holding the poppet valve closed. The purpose of the poppet valve is to prevent the bladder from protruding into the piping and system. Poppet Valve Bladder Page 10 Hydraulic Accumulator Maintenance & Safety

In drawing B, the hydraulic pressure has compressed the nitrogen to the maximum system pressure (2000 PSI). The hydraulic and nitrogen pressures are equal at this point. When the directional valves are energized to extend the cylinders (C), the hydraulic pressure drops. The nitrogen in the bladder forces the fluid out at a high rate of flow. In normal operation the bladder should not contact the poppet valve. Hyadrulic Accumulator Maintenance Safety Page 11

Replacing the Bladder for Bottom Repairable Accumulators Install the charging rig to the bladder valve and release the nitrogen pre-charge. Insure that the hydraulic pumps have been locked out and the pressure has been bled down to 0 PSI prior to removing the accumulator from the machine. All oil should be drained before disconnecting the hydraulic lines. 1) Remove the accumulator and place on a work bench. Install the charging rig again to insure that the precharge has been released. It is always a good idea to remove the valve stem from the bladder. In some cases when the bladder ruptures and deflates, it will fold over inside trapping a small amount of nitrogen pressure. Removing the Poppet Valve 2) Remove the nut, washers and the O-ring on the poppet valve assembly. You will also need to remove the smaller nut on the bladder. Poppet Valve Assembly 3) The poppet will have to be pushed inside the shell to remove the retainer ring. Sometimes the retainer will stick to the accumulator shell or the poppet valve. The retainer is designed to fold in half for removal. The retainer ring will have to be removed before the poppet valve. Page 12 Hydraulic Accumulator Maintenance & Safety

4) Once the poppet valve is removed, the bladder can be removed as well. A 5-gallon bucket can be used to catch the oil that is inside the ruptured bladder. Removing the Bladder 5) Prior to installing a new bladder, the inner shell should be cleaned. Also, inspect the old retainer ring for damage. It is always best to replace the old retainer ring with a new one. There is a good possibility that the hydraulic system has over heated prior to removal. Heat causes rubber to harden and get brittle. Damaged Retainer Ring 6) The inner shell of the accumulator and the bladder should be lubricated with hydraulic oil. This provides a slippery surface that will make it a little easier to install the new bladder. A threaded tool can be attached to the bladder to help pull the bladder into the shell. 7) The poppet valve assembly can now be installed in the reverse order. Never pre-charge the accumulator in the shop. Install it first! Slightly open the nitrogen bottle valve when initially pre-charging the first 50 PSI. Otherwise the cold nitrogen introduced quickly can cause the rubber to become brittle and rupture. Hydraulic Accumulator Maintenance & Safety Page 13

Accumulator Dump Valves A circuit using a hydraulic accumulator must have a method of bleeding the pressure down when the system is turned off. All accumulator systems should use a manual or automatic dump valve to accomplish this. If the pressure is not bled down then the accumulator will remain charged over a period of time. Prior to working on the system you should verify that the pressure is bled down by observing the pressure gauge when the machine is turned off. In some cases, the electric motor is turned off, however control power to the system directional valves remains on. If a photocell, limit switch, or proximity switch is made accidentally, the directional valve can shift causing the cylinder to move. Manual Dump Valve The manual dump valve is normally a small valve, ¼ or less. Anytime the pump is turned off and maintenance is performed, the valve should be opened. Page 14 Hydraulic Accumulator Maintenance & Safety

Solenoid Operated Dump Valve The solenoid on the normally open dump valve is usually wired in to the electric motor starter. When the motor is started the valve will shift closed, blocking flow back to the tank. When the pump is turned off, electrical power is removed from the dump valve solenoid. The valve spool will then spring return to the open position. The pressurized fluid in the accumulator will automatically bleed to tank through the dump valve. Pilot to Close Check Valve When the pump is turned on, pilot pressure plus the spring pressure holds the valve closed. Flow is then blocked back to tank. When the pump is turned off, pressure in the pilot line will bleed down through the internal clearances inside the pump. Pressurized fluid in the accumulator will shift the valve open, dumping the oil back to tank. Hydraulic Accumulator Maintenance & Safety Page 15

Differential Dump Valve The valve is shifted open and closed by hydraulic pressure. The pilot pressure taken immediately downstream from the pump acts on a much larger area than does the pilot pressure that is sensed from the accumulator. The area difference is usually a 4:1 ratio. For example, if the larger area is 1 square inch, then the smaller area on the opposite end of the spool is ¼ or.25 square inches. When the pump is turned on, the same pressure will be exerted on both sides of the spool. The valve is not usually large enough to dump the total pump volume back to tank. For this reason the pressure builds up. With the same pressure (1000 PSI) on both sides of the valve spool, the valve shifts closed because more force is exerted on the larger end of the spool. Page 16 Hydraulic Accumulator Maintenance & Safety

Force to Shift Closed = PSI x Area Force to Shift Closed = 1000 PSI x 1 square inch Force to Shift Closed = 1000 lbs force Force on Opposite End = 1000 PSI x.25 square inches Force on Opposite End = 250 lbs force When the pump is turned off, the valve shifts back into the open position shown in the Power Off condition. The oil in the accumulator then returns back to tank. Accumulator Safety The accumulator is the most dangerous hydraulic component in the system, simply because it is a source of stored energy. Several safety procedures should be followed when working with accumulators. Follow all ZES lock out. LOCK OUT the pump, Then make sure the pressure is bled down out of the hydraulic system and accumulator before working on or around the machine. Watch the pressure gauge when the system is turned off. If an automatic dump valve is used, then the pressure should gradually drop to 0 PSI. If the pressure is not bled down, locate the manual dump valve. Open the valve and recheck the pressure. If it is bled down, LOCK the valve into the open position. In a quiet area, you can hear the pressurized fluid returning to tank through the valve. Hydraulic Accumulator Maintenance & Safety Page 17

Release the nitrogen pressure with a charging rig before removing the accumulator from the system. If the protective cap cannot be removed, do not cut it off with a torch. The compressed nitrogen can be released violently, causing possible hearing and other physical damage. Always pre-charge the accumulator once installed on the machine. NEVER pre-charge an accumulator in the shop and carry it into the plant. NEVER pre-charge with nitrogen pressure above the maximum pressure of the accumulator. The maximum pressure is stamped on the outer housing of the accumulator. Make sure accumulators are properly clamped. Page 18 Hydraulic Accumulator Maintenance & Safety