!"" #$% "!&' ( ( ) *



Similar documents
GAS SAFETY PRECAUTIONS

Instruction Manual. Fun Pop 8oz. Popper

Sno-Kone Syrup Dispenserack

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: Natural Gas

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

Your safety and the safety of others are very important.

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

PROFESSIONAL POPCORN MAKER

OWNER S MANUAL FOR PROFESSIONAL POPCORN MACHINE

Getting the best from your urn

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

San josé OWNER S MANUAL

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series:

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

SL280UHV SERIES GAS FURNACE WARNING

Mini-led spotlight with magnetic base

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

orlando OWNER S MANUAL

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Electrical Connection. Provide Proper Electrical Supply. Electrical Requirements. Connecting using the supplied cord and plug

Instruction Manual Model #2343PXJ, 2344PXJ, 2345PXJ

TWO BURNER PROPANE CAMPING STOVE

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Electric Water Heater

CARING FOR YOUR WATER HEATER

TWO BURNER PROPANE CAMPING STOVE

Customer Support

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

ASK THE EXPERT: Burner Troubleshooting Information & Maintenance

Bottom Loading Water Dispenser

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

INSTALLATION INSTRUCTIONS

OUTDOOR GAS FIREPLACE USER GUIDE North America _2 EF

Advantium 2 Plus Alarm

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Instantaneous gas water heater

T360 Barbecue. Assembly Manual (G30531) Propane 1 YEAR LIMITED WARRANTY

INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE

PREPIPED LIQUID FUEL MANIFOLDS PLPM


WARMER or COOKER/WARMER

Churrasco/Grill Manual Models: 2ft, 3ft, 4ft, 5ft & 6ft (with or without motor driven spits)

HEAT WAVE DUCT KIT KIT #

3 IN 1 BATHROOM HEATER

ROUTER TABLE INSERT ASSEMBLY AND OPERATING INSTRUCTIONS

PROFITEER POPCORN MACHINE SERVICE MANUAL

GIANT POPCORN MACHINE SERVICE MANUAL

G670 Intermittent Pilot Ignition Controls

Installation Instructions for Alarm Module Kit A043F059

SHC 2.5, SHC 4 MINI-TANK ELECTRIC WATER HEATERS INSTALLATION INSTRUCTIONS FOR THE LICENSED PLUMBER SHC 2.5 SHC 4. English. English

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

NUGGET GOLDRUSH PLUS T-2000 POPCORN MACHINES SERVICE MANUAL

Operator: Save these instructions for future use!

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Model 1756 Test Lead Kit

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Multi-Pitch Pitching Machine USER MANUAL

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

Troubleshoot resources for homeowner

Micron-Master EL Series Fogger

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Installation Operation & Maintenance Manual

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Super Cascade Filtration Systems (CE)

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

Installation Manual DIAPHRAGM WELL TANK

RESIDENTIAL GAS-FIRED WATER HEATERS OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL GAS COOKTOP. Please read this guide thoroughly before installation. P/No.: MFL

COMPRESSED AIR DRYER

INSTALLATION INSTRUCTIONS

Oil and Coolant Circulating Heating System. Model - OCSM

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

OPERATORS MANUAL MG22 MEAT GRINDER MG22/0209 ED

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Please keep this manual for f uture reference.

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

INSTALLATION AND OPERATION MAINTENANCE

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Your safety and the safety of others are very important.

SunMaxx Solar Filling Station Operating Instructions

Model 854/856. Operating and Assembly Manual. Palmor Products Inc Serum Plant Road Thorntown, IN 46071

Convection TCO600. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

Transcription:

!"" #$% "!&' (( ) *

G Whiz Gas Popper Instruction Manual Model #5908 Part No. 74874 Revised October 1997 Cincinnati, OH 45241-4807 USA

GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells gas can be obtained from the local gas supplier. These instructions must be posted in a prominent location where the unit is to be operated. Do NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury, or death. Read the Installation, Operating and Maintenance Instructions thoroughly before installation or servicing this equipment. Keep this appliance free and clear of combustibles. Do NOT obstruct the flow of combustion and ventilation airways. NOTE The wiring diagram is located under the dome of the machine, next to the drive motor. NOTE The information, specifications and illustrations contained in this manual represent the latest data available at time of publication. Right is reserved to make changes as required at the discretion of Gold Medal Products Company without notice.

SAFETY PRECAUTIONS This equipment is designed and sold for commercial use only. This equipment is not to be used by the consumer in home use. Do not allow direct contact of this equipment by the public when used in food service locations. Only personnel trained and experienced in the equipment operation may operate this equipment. Carefully read all installation instructions before operating the equipment. Always wear safety glasses when servicing this equipment. To avoid serious burns, do NOT touch the kettle while it is hot. Any alterations to this equipment will void the warranty and may cause a dangerous situation. NEVER make alterations to the equipment. Make sure all machine switches are in the OFF position before plugging the equipment into a receptacle. Machine must be properly grounded to prevent electrical shock to personnel. Do NOT immerse the kettle, warmer, or any other part of this equipment in water. Always unplug the equipment before cleaning or servicing. NOTE The information, specifications and illustrations contained in this manual represent the latest data available at time of publication. Right is reserved to make changes as required at the discretion of Gold Medal Products Company without notice.

INSTALLATION This instruction booklet is very thorough and complete. Please take the time to read this entire booklet before attempting to operate the appliance. Your 12 Oz. commercial popper is the finest 12 Oz. Gas Popper ever built. No expense has been spared to give you a long lasting unit to withstand the heavy loads of commercial popping. The special kettle is extra-heavy to prevent burnouts or warping and is made from excellent heat conducting aluminum. UNPACKING AND ASSEMBLY After unpacking your 12 Oz. Gas Popper, set it on a counter where you intend to use it and remove all tape. Make sure clearances around the appliance comply with the marking on the data plate for the location you have selected. Bolt the Popper to the counter to secure it from tipping. Use the drilling template below for proper hole alignment. GAS INSTALLATION When installing your new 12 Oz. commercial Gas Popper, you must conform with local codes or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1-1992 or latest edition. Gas is safe when used properly, but can be very dangerous when used improperly. We suggest that installation be carefully made by qualified personnel only. Gas companies have competent service personnel to provide safe installation. When selecting a combustible and noncombustible location for your new 12 Oz. Gas Popper, pay close attention to the installation clearances. The minimum clearance for the side (rear) opposite the dump handle is 10 inches. The minimum side clearance is 30 inches. Suitable for installation on combustible counters. The appliance and its individual shutoff valve must be disconnected from the gas supply piping during pressure testing of the system in excess of 1/2 psig (3.45 kpa). During any pressure testing of the gas supply piping system at pressures equal to or less than 1/2 psig (3.45 kpa), the appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve. NOTE: Be sure to provide adequate air supply and adequate clearance for air openings into the combustion chamber. Be sure to provide adequate clearances for servicing and proper installation. After installation, all gas connections must be checked for leaks with a soap solution Do not use a match or flame to check for leaks - you may cause a fire or explosion! When gas connections are complete, wire the unit to a power source which will carry the current specified on the units data plate. 1

ALTITUDE RANGE The factory has sized the burner orifices for an elevation up to 2000 feet above sea level. For high altitude operation contact gold medal customer service department. GAS PRESSURE We have determined that optimum popping occurs when the gas pressure is adequate. For propane gas we recommend a manifold pressure setting of 10 inches of water column (6 oz/ sq in). The pressure is measured at the appliance while the main burner is ignited. Follow instructions in the maintenance and repair section of this instruction manual. Adequate gas requirements are maintained by proper pipe sizing. Be sure to use properly sized pipe to supply the needed pressure. LIGHTING AND SHUT-DOWN INSTRUCTIONS 1. Turn the gas safety valve handle to the PILOT position. 2. Push down safety valve reset button and hold a match to the pilot burner. Repeat until pilot lights. Continue holding the reset button for 30-45 seconds, until the pilot remains burning when the button is released. 3. Turn the gas safety valve handle to the ON position. The main burner should now ignite from the pilot burner. 4. Should you want to turn both the pilot and main burner off, pull the gas safety valve and turn the handle to the OFF position. If pilot is turned off, a five minute shutdown period is required before attempting to re-light. 2

TO MAKE POPCORN Do not leave main burner operating when not popping popcorn! Turn the main burner on. Put oil in the kettle. You may let oil heat in kettle before adding popcorn and salt. We recommend 12 ounces of corn, 4 ounces of high quality coconut oil and Flavacol salt to get the best results. An accurate measure of oil and flavacol is the secret to great tasting popcorn, popcorn that brings back repeat customers. If you are in a commercial pre-pop operation, this is even more important. Good quality popcorn commands a high price, and to your customer it is well worth the slightly higher price. You may put more popcorn into the kettle, but this will lengthen the popping cycle and your overall production will decrease. You can make smaller batches if necessary, but always use a corn to oil ratio of 3:1. Also, when making small batches, or in between batches, you may want to turn the main burner flame down to prevent it from getting too hot. IF THE FLAME GOES OUT A five minute shut down period is required before attempting to re-light. 1. Check to see if you are out of gas. 2. Check to see if the thermocouple is in proper position. At no time during a power failure is there to be an attempt to operate this unit. In the case that a power failure occurs during operation, the gas supply is to be shut off until power is resumed. Then (and only then) should a re-light be attempted per the lighting and shut-down instructions. TO CLEAN KETLE Unplug machine before cleaning. In order to keep your popper working efficiently, wipe the inside of the kettle with a damp cloth. There is no need to clean using a detergent, since this will only remove the oil. 3

MAINTENANCE INSTRUCTIONS THE FOLLOWING SECTIONS OF THIS MANUAL ARE IN- TENDED ONLY FOR QUALIFIED SERVICE PERSONNEL WHO ARE FAMILIAR WITH ELECTRICAL EQUIPMENT. THESE ARE NOT INTENDED FOR THE OPERATOR. Do NOT perform and service or repairs on this equipment. Contact our factory, a sales representative, or your local service company for service or repairs. Adequate eye protection must be used when servicing this equipment to prevent the possibility of injury. Do NOT immerse the kettle, warmer, or any other part of this equipment in water. ORDERING SPARE PARTS 1. Identify the desired part by checking it against the photos, illustrations, and/or the parts list. 2. When ordering, please include part number, part name, and quantity desired. 3. Please include your model name and machine serial number (located on the machine nameplate) with your order. 4. Address all parts orders to: Parts Department Gold Medal Products Co. 10700 Medallion Drive Cincinnati, Ohio 45241-4807 or, place orders at: (513) 769-7676 Fax: (513) 769-8500 E-mail: goldme19@eos.net 4

KETTLE ASSEMBLY 5

KETTLE ASSEMBLY Item No. Part No. Description 1 74870 Whole Kettle Assembly 2 47326 Set Collar, ½" I.D. x 7 /8" O.D. 3 74852 Kettle Heat Shroud 4 74859 Kettle Stop Rod 5 74863 Kettle Pivot Rod 6 74865 Kettle Weldment 7 74868 Agitator / Lid Assembly 8 41742 Set Screw (10-32 x 3 /16") 9 47059 Spur Gear 10 47102 Dump Handle Assembly 11 47106 Needle Bearing 12 47107 C-ring 13 47119 Kettle Lid, Rear 14 47296 Lid Lifter Knob 15 47720 Kettle Lid, Front 16 47751 Set Screw 17 61025 Crossbar Assembly 18 61093 Agitator Weight 19 74869 Agitator Shaft Weldment 6

CABINET ASSEMBLY 7

CABINET ASSEMBLY Item No. Part No. Description 1 74547 Burner 2 74576 12V D.C. Motor 3 74854 Hanger Arm, Left 4 74855 Hanger Arm, Right 5 74857 Burner Mounting Bracket 6 74858 Burner Shroud 7 74856 Motor Plate 8 74860 Bracket, Gas Train Mounting 9 47002 Bottom Extrusion Frame Assembly 10 47003 Old Maid Pan 11 47006 Drop Panel Assembly 12 47238 Glide 13 47389 Bottom Cover 14 49351 Front Corner Post, Bright 15 47065 Kettle Drive Gearbox 16 47059 Drive Gear 17 74861 Mount, Panel 18 74866 Dome 19 77525 Glass Strip 20 77526 Glass Strip 21 77529 Glass Strip 22 n/a 23 77732 Top Frame, Anodized 24 57030 Thermocouple 25 57031 Pilot Burner 26 47165 Corn Pan 8

GAS BURNER ASSEMBLY Item No. Part No. Description 1 57030 Thermocouple 2 57031 Pilot Burner 3 74027 Gas Safety Valve 4 74050 Pilot Orifice,.010" 5 74115 Pressure Regulator 6 74560 "T" Fitting 7 74561 ¼" Aluminum Tubing 8 74568 Fitting, Brass Orifice 9 89694 Lighter Tube Orifice 10 74558 Burner 11 74884 1 /8" NPT x 1½" Nipple 12 74885 Coupling 9

WARRANTY WE WARRANT to the original purchaser the Gold Medal equipment sold by us to be free from defects in material or workmanship under normal use and service. Our obligation under this warranty shall be limited to the repair or replacement of any defective part for a period of six (6) months from the date of sale to the Original Purchaser with regard to labor and two (2) years with regard to parts and does not cover damage to the equipment caused by accident, alteration, improper use, voltage, abuse, or failure to follow instructions. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND OF ALL OTHER OBLIGATIONS OR LIABILITIES ON OUR PART, INCLUDING THE IMPLIED WARRANTY OF MERCHANTIBILITY. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIP- TION ON THE FACE HEREOF. We neither assume, nor authorize any other person to assume for us, any other obligation or liability in connection with the sale of said GOLD MEDAL equipment or any part thereof. The term Original Purchaser as used in this warranty shall be deemed to mean that person, firm, association, or corporation who was billed by the GOLD MEDAL PRODUCTS COMPANY, or their authorized distributor for the equipment. THIS WARRANTY HAS NO EFFECT AND IS VOID UNLESS THE ORIGINAL PURCHASER FIRST CALLS GOLD MEDAL PRODUCTS COMPANY AT 1-800- 428-2676 TO DISCUSS WITH OUR SERVICE REPRESENTATIVE THE EQUIP- MENT PROBLEM, AND, IF NECESSARY, FOR INSTRUCTIONS CONCERN- ING THE REPAIR OR REPLACEMENT OF PARTS. NOTE: This equipment is manufactured and sold for commercial use only. GOLD MEDAL PRODUCTS COMPANY 10700 Medallion Drive Cincinnati, OH 45241-4807 USA