Global Energy Management System Implementation: Case Study

Similar documents
3M Canada s Commitment to Energy Management

Nissan Automaker improves energy performance 7.2% with a four-month payback using Superior Energy Performance

Nissan Automaker improves energy performance 7.2% with a four-month payback using Superior Energy Performance

Global Energy Management System Implementation: Case Study

Sustaining Our Future

Continual Improvement of Energy Performance with ISO 50001

INTERNATIONAL COOPERATION TO PROMOTE ENERGY MANAGEMENT

for Energy Efficiency Parminder Sandhu, P. Eng

Feasibility Study Proposal & Report Guide. Industrial Optimization Program

Global Energy Management System Implementation: Case Study

Document subject to ISO Requirements

How To Understand Energy Management

Energy Performance Indicators (EnPI) Tim Dantoin Focus on Energy

ISO Energy Management System

Checking Performance and Management Review

The Future of Energy Management: Superior Energy Performance

Two Day Energy Management Training. Student Manual

EnergySTEP (Sustainability Tiered Efficiency Program) Our Approach to Energy Efficiency

BS EN Energy Management Systems VICTORIA BARRON, PRODUCT MARKETING MANAGER, BSI

1. Summary. electric grid, strengthen saving programs sponsored by utilities. The project

Paul Scheihing, U.S. Department of Energy Joe Almaguer, Dow Chemical Company Pamela de los Reyes and Tracy Fisher, Energetics Incorporated

Background on the Global Superior Energy Performance Partnership... 2 Acknowledgments Introduction... 4

Dow s Energy Management System. Joe Almaguer Sept. 2015

Win the energy challenge with ISO ISO energy management

CICS Quick Guide to ISO 50001, the New Energy Management System Standard

WORLD CLASS ENERGY MANAGEMENT WORKSHOP

CONTINUOUSLY IMPROVE TO OBTAIN THE ISO 50001

Wonderware: Corporate Energy Management CEM. Dawid Sadie General Manager: Sales Wonderware Southern Africa

Bureau Veritas Energy Audit Summary Report 390 Benmar Drive, Suite 100 Houston, TX (281)

The Role of Internal Audit in Risk Governance

EHS Auditing at Pfizer

ENERGY AUDITS (OR SURVEYS) & ENERGY MANAGEMENT PROGRAMS SECTION B

ISO 9001: A Quality Manual for the Transition Period and Beyond

CSX Public Safety, Health, and Environmental Management System

Implementing an Energy Management System Using ISO 50001

TOTAL QUALITY MANAGEMENT II QUALITY AUDIT

M&V of Hot Water Boiler Plant. Boban Ratkovich, P. Eng, CEM, BESA, LEED AP President CES Engineering Ltd

The ISO standard

Corporate Carbon Neutral Plan

Fact Sheet. Sustainable Textile Production (STeP)

ENVIRONMENTAL POLICY & MANAGEMENT SYSTEM GUIDE

ENERGY AUDIT REPORT MINIMUM REQUIREMENTS

Fujitsu Group s Environmental Management: Outline of Environmental Protection Program (Stage IV)

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0

DTE Energy Pilot Programs DTE Insight & Retro-Commissioning MPSC Collaborative Joint Workgroup

Welcome! DeLaval Cleaning Solutions Dallas Customer Training Session (GFSI) November 2012

Camber Quality Assurance (QA) Approach

Can Energy Management Deliver Real Savings?

Business Sustainability Challenge The United Illuminating Company

BOMA BESt Assessment Overview

What are the steps to adopt Energy Management Systems?

Bundling small-scale energy efficiency projects

ISO A Standard for the Environment... Today and Tomorrow

John Smegal. Becoming a Certified Practitioner or a Certified Energy Engineer. U.S. Department of Energy

Greening the canned peach production

Energy Savings Performance Contract (ESPC) Lesson Learned Panel. Federal Environmental Symposium- West

About this document. UPS Attention: Sustainability Report Editor 55 Glenlake Parkway N.E. Atlanta, Georgia 30328

E N G I N E E R I N G

Integrating Computerized Maintenance Management System and Energy Efficiency Management System A Modified Approach

EnMS under China s Top- 10,000 Program

IMPLEMENTING ISO 14001:

Energy Efficiency Standards and Labeling in India

Outline for Today s Presentation. Objectives of Environmental Regulations/Laws.

ISO 9001:2015 Internal Audit Checklist

Measurement & Verification Plan

OUTSOURCING STRATEGIES & RISKS FROM AN ISO PERSPECTIVE. Amera-Veritas. Amera-Veritas. Experts in in Quality, Safety & Supply Chain Assurance

NOMINATION FORM. Category for judging: 5 - Digital Government: Government to Government (G to G)

NASDAQ:BLDP TSX:BLD. Smarter Solutions for a Clean Energy Future

Operating Sustainable Facilities

Building Energy Efficiency Opportunity Report

Emission monitoring, reporting, and verification (MRV) for U.S. cap and trade programs. Jeremy Schreifels US EPA

MECHANICAL PROJECT PROPOSAL

ONTARIO'S DRINKING WATER QUALITY MANAGEMENT STANDARD

Implementing ISO 9001

Environmental Policy. JRI Orthopaedics Limited

Certified Residential Energy Auditor (REA) Study Guide

HP SUPPLIER ENVIRONMENTAL PERFORMANCE REVIEW QUESTIONNAIRE

Bill Younger, Manager Business Energy Management Puget Sound Energy Bellevue, Washington

EMS Example Example EMS Audit Procedure

Energy Efficiency Measurement & Verification

Transcription:

Global Energy Management System Implementation: Case Study 3M Naju plant improves Energy Performance 7.14% with SEP and ISO50001 3M Company has a long history of caring for the environment. 3M also has made our effort to contribute to 3M strategic objectives. In 2015, 3M Naju plant, one of 3M international subsidiary, had worked with KEA ( Energy Agency), to implement energy management system. Naju plant obtained certification of the ISO50001, global EnMS standard and is the first company in achieved Superior Energy performance (SEP) from KEA. Naju plant s EnMS implementation enable 7.14 percent improvement in energy performance in 2 years. Naju Plant of 3M 3M Naju plant in Naju city, Jeollanamdo has implemented energy management system that earned the plant both ISO50001 and SEP in 2015. Business Benefits Achieved 3M Naju plant EnMS saves 41,136 GJ and achieved a 7.14% energy performance improvement, saving over $400,000 during 2014~2015. Naju plant, one of 3M subsidiary companies, successfully implemented an energy management system(enms) that meets all requirements of ISO50001 and Superior Energy Performance (K-SEP). Energy savings achieved in our plant were verified by KEA, one of governmental companies. 3M has already been working to save energy and improve energy performance in the past years. Case Study Snapshot Industry Location Energy Management System Product/Service Energy Performance Improvement (%) Chemicals Naju, ISO 50001 & SEP Industrial tape, material 7.14% for 2 years - 3.17% in 2014-3.97% in 2015 EnMS make us more focus on improving energy performance with systematical approach Jonggu Kim Naju Plant manager Annual energy cost savings $ 209,522 Cost to implement $ 224,797 Payback period 13 month 1

3M Naju plant s Profile People: 420 employees Facility: Established in 1990. Has 162,000 sq ft Products: manufacturing and industry product and home product, especially produces tape products, ranging from industrial tapes to common bundling and holding tapes. Energy profile: Electricity 62%, Natural gas 38% Energy management system(s): Certified under the Superior Energy Performance (SEP) program and the ISO 50001 Global Energy Management System Standard Corporate goals 3M has global comprehensive Energy Management Program to guide 3M ongoing process of improving energy efficiency, reducing operating costs and reducing impacts on the environment. Our goal is to make energy/carbon efficiency a competitive advantage for 3M and to maintain a positive 3M image. The Naju plant also work with 3M locations to help 3M control energy use, costs and the environmental impacts related to energy use. 3M Energy use and costs are tracked at over 250 locations in 39 countries world wide. For an unprecedented and industry-leading 10th consecutive year, 3M has earned the U.S. Environmental Protection!gency s (EP!) ENERGY ST!R Partner of the Year Sustained Excellence!ward for its comprehensive worldwide energy conservation efforts. No other industrial company has achieved this distinction as many times. 3M had 2015 Energy efficiency goals that that is improving energy efficiency 25% by 2015 from 2005 base year. To achieve corporate goals, the plant has a target that is a reduction in energy intensity of 3 percent per year as measured in British thermal units per pound (Btu/lb (joule/kg)); and the plant has an additional goal of 15% intensity-based performance improvement relative to the 2010 baseline. Metrics : BTUs Finished and Semi-finished Goods Keys to Success Benefits of SEP & ISO50001 and Key to Naju s Success SEP & ISO50001 certification is a great milestone which is a result of robust processes in the system. There are many benefits like Sustainable energy efficiency improvement Develop energy cost saving opportunity Increase energy efficiency through actual statistical energy data Energy cost saving with energy efficiency improvement Co-work with KEA Our key to Success Energy management is a long term planning. Our plant have tried to reduce energy cost and improve energy efficiency for years. Metering energy usage is a key to drive to success EnMS implementation. Metering data can be used while finding energy loss and proving energy saving. Management support is the most important source of EnMS implementation. Managing energy saving projects and performing projects actively can make management more receptive to funding 2

EnMS Development and Implementation Our company management agreed to implement EnMS system. The Naju energy team proceeded development and implementation of EnMS at the plant. Energy team Plant Manager Plant engineering Manager Coordinator Electrical, Utility team Audit team EnMS implementation step Role & responsibility Ensure the EnMS is established, implemented, maintained, and continually improved Lead implementation Energy data collection and Performing projects Lead audit Checking ( measurement and analysis, legal and other requirements, internal audit, control of records) ISO50001 requires all staff to be trained to certain competencies. Our energy team had been trained from a governmental company and then team members educated other employees. To assist with EnMS implementation, the plant hire a consulting company. A expert from hired company also educate our employees to reinforce their mind and culture. SEP certification required a greater depth of energy-use analysis than required for the ISO50001 certification. The plant followed step like below. The first step to certify ISO50001 and the SEP was reviewing plant s energy use. To develop baseline of Naju plant, the plant made energy flow drawings for electricity and gas. The plant also gathered related data. Our EnMS implementation strategy was to Energy usage & balance map Energy flow diagram List of metering units Which was useful to understand energy flow. This kind of analysis was conducted which identified significant energy use, room for improvement in planning, operational controlling and training. In order to adopt ISO 50001 framework, following actions were taken Energy Policy was made that was based on our 3M energy policy. Energy planning ( energy review, energy baseline, energy performance indicators, targets and action plans) Implementation operations (competence, training, communication, documentation, operational control) Energy Review for Naju plant Energy usage & balance mapping Define production baseline of energy usage Develop Key Factor Find key factor like total output amount, heating degree days, cooling degree days, other variables 3

Data managing for Energy Energy data collection & verification system set up Energy map improvement Baseline modeling and review Model application and review Linear Regression analysis of modeling Measurement & Verification Measurement & Verification Verify model application Applied to actual energy management system Corrective action set up EnPI Tool To assist plants in measuring and verifying plant-wide improvement, KEA( energy agency) offered EnPI tool (Energy Performance Indicator) which is linear regression analysis method. By Using this tool, the plant measure actual energy performance improvements in compliance with the SEP measurements and verification protocol. But when using this tool, factors that affect energy use have to been reviewed and analyzed thoroughly. The company establish a normalized baseline of energy use, measure annual energy performance improvements and identify energy performance indicators. Internal and Third-party Audit In 2015, the Naju plant achieved third part certification to SEP and ISO50001. The third party certification for SEP and ISO50001 were performed separately. But audit steps are similar to each other. Pre-Audit : An auditor visited and reviewed progress of EnMS adoption. An auditor advised several points to get better grade. Phase 1 : A third part reviewed submitted documentation Phase 2 : Two-day on site visit to verify that the facility complied with the certification requirements. Financial Support 3M Naju plant received financial support from 3M internally with Corporate Energy team s support. Staff at the plant also contributed by giving their time and commitment to the process. Regarding SEP certification, KEA ( Energy Agency) had financially supported from consulting and implementing to audit. The Naju plant was the first pilot project to KEA. Energy team 3M Naju Energy Team The Naju energy team have carried out from metering and performing projects to employee education Work with passion Team members enthusiastically investigated energy saving methods to make energy saving project ideas possible. Members also carried out their assignment to make project went smoothly. Energy team meeting Our team have a regular team meeting to discuss project status and problems. The plant also work with Lean Six Sigma team to get better ideas and calculate benefits using DEMAIC tool. 4

The results 3M Naju plant has already performed energy saving project and collected energy related data. So the plant could set up energy management system more easily. ISO50001, SEP certification in 2015 7.14 percent energy performance improvement relative to previous year s baseline for 2 years, as required by the SEP EnPI tool. Major energy project savings like ; LED Lighting (Saving: $140,000) AHU & Compressor Optimization (Saving : $153,000) Heat Recovery & process improvement (Saving : $66,500) Lessons Learned Measuring and Verification Measuring energy data is essential to improve energy performance. Using this data, engineers can find energy waste or loss of every equipment. The plant collects energy data manually which could cause human error. So the plant are going to install real time energy monitoring system in 2016. The plant expecting Opportunity Monitoring granularity of energy consumption in production Understanding waste in energy consumptions Optimizing energy targets in production Key benefits Reduce unit cost Reduce waste in energy consumption Enhance energy consumptions in production Verification and documentation of energy project savings are also important. A plant can crosscheck their improvements amount and project savings. This kind of savings could lead management s support for further improvements. Key factors for EnMS implementation An EnMS can lead to significant cost savings. To successfully implement this; 1. Management willingness to commit resources 2. Energy team to lead EnMS with individual expert and responsibility 3. The development and performing of energy saving projects Through the Energy Management Working Group (EMWG), government officials worldwide share best practices and leverage their collective knowledge and experience to create high-impact national programs that accelerate the use of energy management systems in industry and commercial buildings. The EMWG was launched in 2010 by the Clean Energy Ministerial (CEM) and International Partnership for Energy Efficiency Cooperation (IPEEC). For more information, please visit www.cleanenergyministerial.org/energymanagement. 5