Steinbeis-Transferinstitut Life Sciences Technologies der Steinbeis University Berlin. Certificate



Similar documents
Certificate. We hereby certify, that the below mentioned production lines meet

Weighing terminals IP69K GMP EHEDG NSF. Precision in stainless steel Easy to clean perfect hygiene

11.I In-process control Authors: Dr. Christian Gausepohl / Paolomi Mukherji / Update 07

GMP Pre-Qualification of Separators Ex Works Flexible and Safe on the GEA Pharmaceutical Test Bay

Meet Global Food Safety Standards and Increase Productivity and Profitability

High-Precision Platforms


German engineering under high pressure

2Technical Support 3Formulation Development 4Proof of Concept 5 GMP Services 6Advanced Drug Delivery 1EUDRAGIT Products Evonik. Power to create.

Corden Pharma Latina S.p.A. 5/20/16

Accuracy and Pharmacutical

GMP ANNEX 1 REVISION 2008, INTERPRETATION OF MOST IMPORTANT CHANGES FOR THE MANUFACTURE OF STERILE MEDICINAL PRODUCTS

Validation and Calibration. Definitions and Terminology

The Quality System for Drugs in Germany

DISCUSSION TOOL PRESENTED TO THE AABB CT REGULATORY AFFAIRS SUBSECTION

ASI 691 Prinicples of HACCP 1

ASSESSMENT OF QUALITY RISK MANAGEMENT IMPLEMENTATION

Calibration & Preventative Maintenance. Sally Wolfgang Manager, Quality Operations Merck & Co., Inc.

Federal Institute for Materials Research and Testing (BAM) Pyrotechnics Division 2.3 Explosives D Berlin Berlin,

This interpretation of the revised Annex

Working Party on Control of Medicines and Inspections. Final Version of Annex 15 to the EU Guide to Good Manufacturing Practice

FAT Factory Acceptance Testing SAT Site Acceptance Testing

testing equipment for quality management Programme summary. METROLOGY Tensile and Pressure Testing Machines Measuring Devices Display Devices

EUROPEAN COMMISSION HEALTH AND CONSUMERS DIRECTORATE-GENERAL. EudraLex The Rules Governing Medicinal Products in the European Union

Aseptic preparations, including TPN, for a limited number of patients

Title:: Effective GMP AUDITS for APIs and Formulation Pharma Companies By G.Sundar-Director/Consultant PharmQA Compliance solutions

NSF Dietary Supplement

Guidance for Industry. Q10 Pharmaceutical Quality System

Contamination Control and Environmental Monitoring Systems

Process Engineering and Product Engineering. Dr. P. M. Pandey

Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD

JANUARY 2013 PREPARATION OF A SITE MASTER FILE FOR A MANUFACTURER OF COSMETIC PRODUCTS

Welcome Computer System Validation Training Delivered to FDA. ISPE Boston Area Chapter February 20, 2014

BEST PRACTICE FOR MAXIMUM TABLET QUALITY, AVOIDING THE FDA WARNING LETTER 483.

Vinod et al., ARPB, 2013; Vol 3 (II) ISSN

Comparison of EU GMP guidelines with WHO guidelines Identification of the cost-intensive requirements

CONCEPTS OF FOOD SAFETY QUALITY MANAGEMENT SYSTEMS. Mrs. Malini Rajendran

Compact Monitoring Technology your environmental monitoring solution

EUROPEAN COMMISSION HEALTH AND CONSUMERS DIRECTORATE-GENERAL. EudraLex The Rules Governing Medicinal Products in the European Union

Qualification of an Environmental Monitoring Program

FDA and the Compounding Pharmacy

MHRA GMP Data Integrity Definitions and Guidance for Industry January 2015

Media fills Periodic performance qualification (Re-Validation)

Manufacturing Cellular Products for International Clinical Trials

Guide to Master Formulae WHO/FWC/IVB/QSS/VQR

2016 > Emcure Pharmaceuticals Limited 3/3/16

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Design, Operation and Management of GTP/GMP Cell Engineering Facilities

Library Guide: Pharmaceutical GMPs

HAZARD ANALYSIS CRITICAL CONTROL POINT PLAN SUMMARY SETHNESS PRODUCTS COMPANY LIQUID CARAMEL COLOR

Implementation of ANSI/AAMI/IEC Medical Device Software Lifecycle Processes.

Particle Monitoring Requirements in Pharmaceutical Cleanrooms

Precision injection moulding

EudraLex. The Rules Governing Medicinal Products in the European Union Volume 4

ÖNORM EN The European Standard EN has the status of an Austrian Standard. Edition: Standards group B

PORTIO. Intelligent Portion Cutter. High speed cutting: Fixed weight, fixed thickness. High precision, minimal give-away.

Conductivity Sensor Calibrations to Meet Water Industry Requirements

Visualization coupled with visual appeal

COMPLIANCE BY DESIGN FOR PHARMACEUTICAL QUALITY CONTROL LABORATORIES INSIGHT FROM FDA WARNING LETTERS

What Are the Differences?

TSI BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER FACILITY MONITORING SYSTEMS

Implementing SPC for Wet Processes

Metal Pressfitting Pipe Systems

New changes to cleanroom & clean air device classifications: ISO & 2

3-Day GMP Education Course June 2008, Barcelona, Spain

Pharmaceutical Wholesaler Site Inspection Checklist

Timeworks Manufacturing Services

Natural Health Products Directorate - Direction des produits de santé naturels

UV Disinfection Systems A Series. Main Applications: Drinking Water, Process Water, Warm Water / Legionellae. IT T Industries Engineered for life

Combination Products. Presented by: Karen S. Ginsbury For: IFF March PCI Pharma

Annex 9 Guide to good storage practices for pharmaceuticals 1

International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation

Integrating Good Manufacturing Practices During the Transition from Clinical Trials to Commercial Manufacturing

Tableting Punch Performance Can Be Improved With Precision Coatings

Our dispensing solutions ensure the right weight and transfer this precise measurement to your ERP system.

C 5. chemical development contract research custom synthesis cgmp API manufacturing commercial production. Welcome to

QUALITY SYSTEM REQUIREMENTS FOR PHARMACEUTICAL INSPECTORATES

Computer-Aided Facilities Management - A Logical Trend

Retail Scale bc: be connected be successful

The FDA recently announced a significant

Questionnaire Pure Media Systems

MeriCal Quality Profile

Reduced to the best. Visualize and Control Solutions for Process Automation

Quality Assurance. Disclosure for Lilli Møller Andersen. No relevant financial relationships exist for any issue mentioned in this presentation

LEVEL CONTROL INSTRUMENTATION

Calibration Service Selection Guide

File:Quality-Management Manual-V2

LIBRARY GUIDE. Online Courses. March 2012

I. PURPOSE This SOP describes policies, procedures, and record keeping requirements for all documents subject to change control.

AIR-HANDLING-UNITS FOR THE CHEMICAL / PHARMACEUTICAL SECTORS

Injection Molding Machines Benefit from

Making SOP Training More Effective

GLUTEN-FREE CERTIFICATION PROGRAM

PHARMACEUTICAL QUALITY SYSTEM Q10

Good Manufacturing Practices: A Synopsis of Their Role and Rationale in Today's Pharmaceutical Marketplace for Tubing

Quality Agreement. by and between. Supplier Name. Address: and. Client Name: Address:

Transcription:

Certificate We hereby certify, that the below mentioned production lines meet all GMP-guidelines, EG GMP-Annex 15 guideline and PIC/S guideline PI 006-1 requirements. Product lines: Manufacturer: Series IND4x9 Mettler-Toledo (Albstadt) GmbH Unter dem Malesfelsen 34 72458 Albstadt Germany Tübingen, 31.07.2005 Prof. R. Ziegler 1 Steinbeis Transferinstitut Direktor: Prof. Ronald Ziegler Tel.: 07071-3659475 Fax: 07071-3659476

1. Description of the Terminal-line Industrial terminal-line with a high quality operating unit consists of V2A steel (1.4301 respectively. AISI 304). The industrial compact-system includes a terminal of the IND4x9 series. The terminal-line consists of V2A steel and fulfils the protection class IP69K in accordance with DIN 40050. The complete terminal-line is especially conceived for the use in the wet areas and it is suitable for cleaning with high pressure cleaning machines. The terminal-line stands out due to different application steps, weighing capacity and interface options. Calibration capable models of the precision class III to OIML are available. All models fulfil the electrical safety regulations in accordance to EN61010-1 as well as the norms for not independent balances in accordance to EN45501. Page 1 Steinbeis-Transferinstitut

2. General requirements of balances Balances have to show the suitable measurement range and the required precision (EC- GMP guide, chapter 3.40). They have to be calibrated regularly, what is to be documented (EC-GMP guide, chapter 3.41). The permitted tolerance must be provided under consideration of the measuring inaccuracies, i.e. the still tolerated deviation of the debit value, for the respective weighing capacity. The equipment used at the handling with the raw materials and utensils must meet the requirements for surfaces in the pharmaceutical production. The FDA writes according to 211.65 construction of the equipment: (a) Equipment shall be constructed so that surfaces that contact components, in-process materials, or drug products shall not be reactive, additive, or absorptive so as to alter the safety, identity, strength, quality, or purity of the drug product beyond the official or other established requirements. The here tested scales are constructed with high-grade steels V2A (1.4301, 1.4304) and V4A (1.4401, 1.4404, 1.4571) according to generally recognized construction guidelines. The cleaning ability is confirmed by the cleaning validation. Established cleaning instructions are necessary as a prerequisite for a cleaning validation The at most permitted spreading amount of active ingredients and cleaning agent is depending on the preliminary product, the derivative product and the lot size of the derivative product. A general statement for not critical products can be made with the criteria "visual clean". Due to respected and in the literature described tests a quantity in backlog of 375 µg per 100 cm² is no longer visible. Page 2 Steinbeis-Transferinstitut

3. Appraisal criteria for an optimal cleaning General In principle, the parts which come in contact with the product, these are the load plates of the balances, have to be cleaned well. Both the FDA inspection guideline for cleaning validation and the PIC guideline PIC/S 006-1 name the visual criteria as acceptance criteria to appraise the cleaning success. The terminals of the series IND4x9 were subjected to a qualified examination regarding "clean ability". Therefore the criteria visually clean was used. This means that the terminals of the series IND4x9 must be free of visible residua after cleaning. As a basis for this examination the works of Buscalferri, F., Assignation of the visibility limit of pharmaceutical active agents ( Bestimmung der Sichtbarkeitsgrenze von pharmazeutischen Wirkstoffen ), master thesis, Albstadt-Sigmaringen University, course of studies pharmaceutical technology (1999) and Fourman, G. L., Mullen, Determining Cleaning Validation Acceptance Limits for Pharmaceutical Manufacturing Operations, Pharm. Technol. 17 (4), 54 (1993) were used. Proceeding As examination sample there was chosen granulate, that was colored with Erythrosine. As a basis the criteria visually clean (please see GMP Berater 8E (11)) was consulted. Different pollution degrees were feigned, the terminals of the series IND4x9 were polluted and then cleaned with a common cleaning agent (P3-cosa PUR 80 Manufacturer: Ecolab GmbH & Co. OHG, Düsseldorf), used in the pharmaceutical production. The cleaning success was then appraised visually In addition; a cast test was carried out before and after the cleaning to determine the complete microbial count. The exact data can Page 3 Steinbeis-Transferinstitut

be taken from the SOP for cleaning and the test report is also obvious that the depletion degree which is dependent on the examination material and the specific requirements of the examination meets in principle the hygienic requirements. Results The terminals of the series IND4x9 correspond to the visually clean criteria. The cast test for the determination of the complete microbial count showed a significantly lower complete microbial count after the cleaning. Summary The terminals of the series IND4x9 are GMP-compliant. The cleaning can be carried out very well. There aren't any heavily accessible places in which dust could accumulate. Page 4 Steinbeis-Transferinstitut

4. Appraisal criteria for a qualification General The PIC/S guideline PI 006-1 and the EG-GMP guide Annex 15 mention principles for qualification and validation. Every machine or equipment which directly or indirectly influences the quality of the product shall be qualified. The machine or equipment shall be designed in agreement with the prevailing GMP guidelines. The machine shall be installed in agreement with the design specification and the functions shall be checked with the available documentation (functional qualification Proceeding The available documentation of the terminals of the series IND4x9 was checked to the effect whether a design qualification, installation qualification and functional qualification is feasible. Page 5 Steinbeis-Transferinstitut

Results The documentation of the terminals of the series IND4x9 is very detailed. A detailed description of the balances with design drawings is available. The used materials are described in detail. GMP-relevant documents are available (e.g. inspection certificate, CE-mark). Details on the maintenance are listed. Summary The documentation of the manufacturer of the terminals of the series IND 4x9 is very detailed and offers the necessary conditions for the execution of a qualification as it is demanded by EG-GMP guide Annex 15 and PIC/S guideline PI 006-1. Page 6 Steinbeis-Transferinstitut