Energy Benchmarking City of New Westminster: Corporate Facilities



Similar documents
Portfolio Manager and Green Power Tracking

Communicating Your Commitment: Your Guide to Clean Energy Messaging

ENERGY STAR Portfolio Manager Data Collection Worksheet

ENERGY STAR for Data Centers

Residential & Commercial Sectors Overview CLIMATE

U.S. Energy Use Intensity by Property Type

Climate and Weather. This document explains where we obtain weather and climate data and how we incorporate it into metrics:

National Energy Benchmarking Framework: Report on Preliminary Working Group Findings

System: Portfolio Manager

Corporate Carbon Neutral Plan

The Greenhouse Gas Protocol

ENERGY STAR Portfolio Manager Data Collection Worksheet

Tools for Energy Tracking and Benchmarking. ENERGY STAR Portfolio Manager for Congregations

TransCanada Case Study: Emissions Management System

Level 1 Energy Audit Report. For: Gladstone Regional Council

Non Domestic energy consumption 2013 Kent Local Authorities (Previously Industrial & Commercial energy use)

Metro Washington, D.C., Greenprint Performance Report VOLUME 1, 2012: PUBLISHED SPRING 2014

Using ENERGY STAR Portfolio Manager

Corporate & Community Climate Action Plan

Scope 1 describes direct greenhouse gas emissions from sources that are owned by or under the direct control of the reporting entity;

Supplier Guidance Document. Energy and Fuel Use Data from Hertfordshire County Council Outsourced Services

SSE s criteria used for GHG emissions reporting

GREENHOUSE GAS EMISSIONS INVENTORY

Building Energy Efficiency Opportunity Report

North American Centre 5650 & 5700 Yonge Street, Toronto Greenhouse Gas Inventory Report

Commercial Energy Use Worksheet

degrees Fahrenheit. Scientists believe it's human activity that's driving the temperatures up, a process

Democratic and Republican Positions on Environmental Issues. Edward H. Klevans, Professor and Department Head Emeritus of Nuclear Engineering

TOWN OF CARRBORO NORTH CAROLINA

Smart Facilities Management with Oracle Applications. Statement of Direction August 2011

Fact sheet. Conversion factors. Energy and carbon conversions 2011 update

Table PARKING SPACE RATES AND PARKING SPACE OCCUPANCY

REPUBLIC OF TURKEY INTENDED NATIONALLY DETERMINED CONTRIBUTION

Renewable Choice Energy

Submission by Norway to the ADP

Summary: Apollo Group Greenhouse Gas Inventory (Worldwide)

Four of the twelve Kent districts (Dartford, Gravesham, Shepway and Thanet were below the National average (4,099 kwh) for electricity

How to Earn the LEED Green Power Credit

GHG Emission Reductions Quantification Report

Energy Update Report Summary 2014

Florida Department of Education Student Performance Standards

Fixing the Leaks: What Would it Cost to Clean Up Natural Gas Leaks?

Metropolitan Boston Health Care Energy Profile for

Prudential plc. Basis of Reporting: GHG emissions data and other environmental metrics.

NEW ZEALAND. Submission to the ADP. New Zealand s Intended Nationally Determined Contribution. 7 July 2015

Energy Benchmarking Report for Lafayette Elementary School Bound Brook, NJ

Comprehensive emissions per capita for industrialised countries

CDP7 and OneReport Comparison

This guidebook provides an overview of the eligibility requirements, available funding, and process for municipalities to participate in TAME+.

FACTS ABOUT CLIMATE CHANGE

House of Worship Energy Audits

Status of China s regional trading programs: progress and challenge

Calculating Greenhouse Gas Emissions

Woodfibre Liquefied Natural Gas (LNG) Project. Review of Related Upstream Greenhouse Gas (GHG) Emissions Estimates

Implications of Abundant Natural Gas

Greenhouse gas emissions from direct combustion of various fuels (e.g. grain dryer)

Carbon Credits: An Opportunity for Forest Landowners. Hughes Simpson Texas Forest Service

School District No. 23 (Central Okanagan) 2015 Carbon Neutral Action Report

DATE: June 16, 2014 REPORT NO. PW Chair and Members Committee of the Whole Operations and Administration

Clean Diesel versus CNG Buses: Cost, Air Quality, & Climate Impacts

2009 Energy Policy. Background

Carbon Footprint Calculator for Royal Society of Arts

ENERGY STAR Data Verification Checklist

Making Sense of Climate Change - for businesses and consumers: measuring greenhouse gas emissions ( carbon footprint )

Scope 1 describes direct greenhouse gas emissions from sources that are owned by or under the direct control of the reporting entity;

City of Peterborough s Corporate Energy Management Plan

Vancouver Landfill Gas Capture Optimization Project

Greenhouse Gas Protocol Report for IT Mästaren. Assessment Period: Produced on June 10, 2014 by Our Impacts on behalf of U&W

Overview of the Heavy-Duty National Program. Need to Reduce Fuel Consumption and Greenhouse Gases from Vehicles

FINAL REPORT LIFE-CYCLE COST STUDY OF A GEOTHERMAL HEAT PUMP SYSTEM BIA OFFICE BLDG., WINNEBAGO, NE

Carbon Footprint Report

VERIFICATION STATEMENT GREENHOUSE GAS EMISSIONS

GSL Employer s Requirements Facilities Management Advisor Performance Targets

Energy Projections Price and Policy Considerations. Dr. Randy Hudson Oak Ridge National Laboratory

Integrated Tools for Multifamily Green Asset Management. Energy Upgrade CA Web Portal Funding Finder Compass Portfolio Tracker Webinar May 22, 2012

MAGAZINE OF THE GRAPHIC ARTS TECHNICAL FOUNDATION VOL. 20 NO. 3 JUNE 2008 $15.00

Town of Petawawa Corporate Energy Management Plan

Transcription:

UBC Sustainability Scholar Project Report Energy Benchmarking City of New Westminster: Corporate Facilities August 2015 Priyanka R. Chakrabarti UBC Sustainability Scholar 2015 1

Executive Summary Introduction This report is a brief summary of the results obtained after benchmarking 22 of City of New Westminster s corporate buildings using Energy Star Portfolio Manager. The list of buildings includes Community Centres, Swimming Pools, Firehall, Public Library, Convention Centre, and Offices among others. The building performance data includes energy consumption from December 2010 to Dec 2014. Energy benchmarking is the process of quantifying and recording energy consumption from building operations. Energy benchmarking allows for performance comparisons between buildings. Municipalities can track progress towards energy efficiency targets and energy use reductions. Energy benchmarking can also influence building managers to work towards increasing the building s energy efficiency. According to the City of New Westminster s corporate energy and greenhouse gas emissions management plan, the city aims to reduce its 2007 corporate greenhouse gas emissions quantity by 1311 tonnes Co2e, or 15% percent, by 2017 (Fig. 1). Building benchmarking is one of the tools that is now being used by the city to track the progress in achieving the planned target. 5000 EMISSIONS FORECAST 4500 2007 EMISSIONS QUANTITY EMISSIONS CO2 4000 PERCENT REDUCTION (TARGET)=15% 3500 3000 2009 2011 2013 2015 2017 YEAR Figure 1: Greenhouse Gas Emissions Forecast, Base Year Quantity, and Reduction Target 1 1 Source: http://www.newwestcity.ca/database/rte/greenhouse%20gas%20executive%20summary%20dec %202008.pdf 2

Energy Star Score In Canada, the current version of Portfolio Manager is limited to providing Energy Star Scores for Offices, K-12 Schools, Hospitals and Food Retail only. Only offices (from the building types) apply to the City of New Westminster s portfolio which limits the Energy Star Score 2 availability to 1 building. The remaining buildings have been compared based on energy use intensity (EUI) 3. The energy star score reflects a normalized comparison of the building performance with other buildings of similar type in Canada. The score normalizes with respect to varying climate and accounts for the Property Use Details that the EPA has identified as being important to building operation. The data collected to populate the Property Use Details in Portfolio Manager can be used to provide custom normalization 4 metrics which can be used to calculate the Energy Star Score. There are a number of reporting and planning features within Portfolio Manager that can assist with managing building energy use beyond the provision of energy use comparisons. Examples of these features include: - Setting energy efficient targets and tracking progress. - Reporting energy use trends through standard and custom reporting templates available on Portfolio Manager. 5 Under 5000 sq.m. Over 5000 sq.m. 3.75 2.5 1.25 0 recreation Firehall Swimming Pool Office Library Museum Repair services Convention Centre Figure 2: City of New Westminster Energy Benchmarking Portfolio Building Types Police Station Public Services 2 The Energy Star score is a measure of how well the property is performing relative to similar properties, when normalized for climate and operational characteristics. 3 EUI-calculated by dividing the total energy consumed by the building in one year (measured in kbtu or GJ) by the total gross floor area of the building. Generally a low EUI signifies good energy performance. 4 Weather Normalized Source Energy The source energy use the property would have consumed during 30-year average weather conditions. Weather Normalized is Weather Normalized Source Energy divided by property size or by flow through a water/wastewater treatment plant). 3

6 4.5 3 1.5 0 1930's 1940's 1950's 1960's 1970's 1980's 1990's 2000's 2010's Figure 3- Age of Buildings in the City of New Westminster Energy Benchmarking Portfolio Method The building energy use data is derived from the City of New Westminster s SMARTTooL 5 database. The energy data is determined from billing information and is currently only available for buildings for which the city pays for the utilities. Data is provided for each utility meter and is aggregated for properties that contain multiple meters. Energy use data is provided for Electricity and Natural Gas (depending on the building connections). The City of New Westminster is interested in how the emissions reporting metrics of Portfolio Manager and SMARTTool compare and how these can be used to complement each other for potential data exchange. There is future possibility for integration of the two tools which could help to inform New westminster s Energy benchmarking plan. The largest time commitment associated with the use of Portfolio Manager is the need to continuously update the energy consumption data. This can be done by manually uploading data to Portfolio manager or through the spreadsheet upload templates provided in the software. A detailed procedure for future updates to the City of New Westminster s Energy Use data has been provided in the form of a guidebook to the City of New Westminster s sustainability team. 5 SMARTTool is a GHG emissions reporting tool used to help organizations meet GHG reductions targets. The service is provided by BC Hydro to the City of New Westminster. 4

Challenges A number of issues were encountered while developing the City of New Westminster s energy benchmarking portfolio. The challenges are as follows: 1. Data accuracy and comparison of building types- There are small variations in the values comparing the GHG emissions with the numbers determined by SMARTTool. The Energy Star Score is not currently available for all building types and is not a direct indication of energy consumption. The Energy Star Score allows for a comparison of building energy performance within a category of buildings against the national building stock peer group 6. However, in Canada the Energy Star Score is currently available for only four building types: Offices, K-12 schools, Hospitals and Food Retail, limiting the pool of buildings available for a comparative analysis. 2. Property use types- Property Use Details will need to be added manually to each property type as they are not accounted for in the templates. If property use details are not included Portfolio Manager will use default values based on Property Type and Gross Floor Area when required to perform internal calculations, distorting the EUI values. Also, certain property types are not accounted for in Portfolio Manager, for e.g. Greenhouses. 3. Buildings with multiple uses- A number of the City of New Westminster s properties have multiple uses. The Energy Star Score is based on an average of the use types but Portfolio Manager cautions that common configurations will be provided with a more accurate score if the building is classified only with the single dominant use type 7. The multiple uses have been included in the City of New Westminster s portfolio as this is the preferred approach from the standpoint of building energy management. 4. Uploading data using templates: Portfolio manager can sometimes fail to read the data in the uploaded templates. Due to this issue the updating process can become a very time consuming and tedious task. 6 7 EPA. Technical Reference Energy Star Score. Available online: <https://portfoliomanager.energystar.gov/pdf/ reference/energy%20star%20score.pdf?11 ac-97ca> 5

Table 1: Benchmarking results for the City of New Westminster s corporate buildings. Property Name Property Type Area (m 2 ) Year Built Current (2015) and % change Site EUI Current Site EUI (2015) and % Change GHG Emissions Change Canada Games Pool Swimming Pool 3877 1973 7.70 7.86 (2.1%) 5.93 6.19 (4.4%) 7.6% City Hall Office 5490 1953 0.46 0.54 (17.4%) 0.22 0.26 (18.2%) 17.8% Centennial Community Centre 1926 1985 0.98 0.86 (12.2%) 0.71 0.64 (9.9%) 5.5% Engineering Operations Admin Office & Industrial 557 1952 8.95 8.88 (0.8%) 5.40 5.42 (0.4%) 3.3% Glenbrook Firehall Firehall 7803 2002 0.43 0.41 (4.7%) West End Firehall Firehall 287 1947 2.43 2.62 (7.8%) 0.29 0.28 (3.4%) 1.92 2.12 (10.4%) 9.8% 13.4% Queensborough Firehall Firehall 557 1999 2.47 4.04 (63.6%) 1.87 3.13 (67.4%) 72.2.% Hume Park Washroom 139 1958 7.08 4.34 38.7% 6.51 4.02 38.2% 37.8% Moody Park Arena 2845 1974 2.82 2.60 (7.8%) 1.73 1.54 (11.0%) 16.9% Moody Park Outdoor Pool Swimming Pool 464 2009 5.56 6.20 (11.5%) 3.97 4.66 (17.4%) 27% Public Library Library 4180 1958 1.10 1.15 (4.5%) 0.67 0.70 (4.5%) 4.1% Century House Social/ 2322 1958 0.69 0.69 0.61 0.63 (3.3%) 6.1% Police Services Building Police Station 4923 2001 1.95 1.63 (16.4%) 1.17 0.95 (18.8%) 27.4% Queen s Park Arenex 1254 1938 1.29 0.76 (41.4%) 0.87 0.57 (34.5%) 22.9% Arena 4459 1930 1.99 1.86 (6.5%) 1.23 1.16 (5.7%) 3.6% Centennial Lodge Social/ 737 1960 0.88 0.8 (9.1%) 0.61 0.57 (6.6%) 0% Maintenance Yard Repair Services 297 1945 4.27 3.66 14.3% 2.72 2.36 13.2% 10.9% Greenhouses Public services 696 1970 3.81 3.77 1.0% 3,48 3.38 2.9% `4.2% 6

Property Name Property Type Area (m 2 ) Year Built Current (2015) and % change Site EUI Current Site EUI (2015) and % Change GHG Emissions Change Gardeners Building 185 1956 1.35 0.99 (26.7%) 1.11 0.81 (27.0%) 26.4% Irving House Museum Museum 545 1964 2.05 1.38 (32.7%) 1.17 0.85 (27.4%) 7.5% Queensborough Community Centre Social/ 2415 1978 1.14 1.15 (0.9%) 0.88 0.72 (18.2%) 42.5% Anvil Centre Convention Center 7804 2014 Glossary (GJ/m 2 ) The Source Energy Use divided by the property per square meters. Source Energy Use Source energy represents the total amount of raw fuel that is required to operate the building. It incorporates all transmission, delivery, and production losses. EPA has determined that source energy is the most equitable unit of evaluation for determining the Energy Star Score. Site EUI (GJ/m 2 ) The Site Energy Use divided by the property per square meters. Site Energy Use The annual amount of all the energy consumed on-site by the property, as reported on the utility bills. GHG Emissions Greenhouse Gas (GHG) Emissions are the carbon dioxide (CO2), methane (CH4), and nitrous oxide (N2O) gases released into the atmosphere as a result of energy consumption at the property. GHG emissions are expressed in carbon dioxide equivalent (CO2e), a universal unit of measure that combines the quantity and global warming potential of each greenhouse gas. References EPA. Exchanging Data: Resources to Help Get you Started. Available online: <http:// portfoliomanager.energystar.gov/webservices/home;jsessionid=c3f407aad348c47b 884529D03B0E7959.beta-esws-dist-1> NRCAN. What is building energy benchmarking?. Available online: <http://www.nrcan.gc.ca/ energy/efficiency/buildings/energy-benchmarking/building/3715> 7