On-Demand Water Heater Installation Manual and Owner s Guide



Similar documents
On-Demand Water Heater Installation Manual and Owner s Guide

On-Demand Water Heater Installation Manual and Owner s Guide

T-K3 Instantaneous Water Heater Installation Manual and Owner s Guide

910 / 910 ASME (T-M50/T-M50 ASME) On-Demand Water Heater Installation Manual and Owner s Guide

NAVIEN AMERICA INC FITCH AVENUE

T-KJr. Instantaneous Water Heater Installation Manual and Owner s Guide

T-K3 / T-K3-Pro On-Demand Water Heater Installation Manual and Owner s Guide

Your safety and the safety of others are very important.

CARING FOR YOUR WATER HEATER

T-K2 Instantaneous Water Heater Installation Manual and Owner s Guide

ASX7-4-IOM-7 J

On-Demand Water Heater Installation Manual and Owner s Guide

2010 Residential Water Heater Replacement Check List

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

T-K3-OS and T-K3-SP On-Demand Water Heater Installation Manual and Owner s Guide

Commercial Gas Water Heaters

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL

Installation Instructions

Tankless Water Heater

SOLI TANKLESS PRODUCT GUIDE

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

TANKLESS DURABILITY Tankless Product Guide

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Commercial Gas Water Heaters

Residential Gas - FVIR Certified High Efficiency Condensing Power Direct Vent Water Heaters

TANKLESS GAS WATER HEATER


RECON WATER HEATER INSTALLATION FORM

Gas Water Heaters. Installation and Owner Manual MODELS LCN20/LCL20, LCN26/LCL26 - FOR EXTERNAL INSTALLATION ONLY

DRYER VENTING SPECIFICATIONS DRYER SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

SL280UHV SERIES GAS FURNACE WARNING

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

Installation Instructions

SWIMMING POOL HEAT PUMP

Installation Operation & Maintenance Manual

Water Heaters. Commercial Gas. Use & Care Manual. With Installation Instructions for the Installer. Commercial 75 Gallon

INDIRECT WATER HEATER. Installation and Operating Instruction Manual

AMX300 DirectConnect Mixing Valve Kits

Installation Instructions and Use & Care Guide

CHAPTER 5 WATER HEATERS

n NOTICE n WARNING Read and review this entire manual with special emphasis on the Venting and Operation Sections prior to any installation work.

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

INSTALLATION AND SERVICE MANUAL EPJ SERIES INDIRECT WATER HEATERS

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

INSTALLATION & SERVICE MANUAL

Installation & Operation Manual Models: SIT030 - SIT119

TANKLESS WATER HEATER USE AND CARE MANUAL

PLBG/GAS SAFETY Information Bulletin

INSTALLATION AND OPERATING INSTRUCTION MANUAL

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Arapahoe County Residential Water Heater Installation and Inspection Guide

HEAVY DUTY STORAGE GAS

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Installation Manual CONDENSING TANKLESS GAS WATER HEATER DANGER WARNING CAUTION CAUTION

GAS SAFETY PRECAUTIONS

Commercial. Gas-Fired Water Heaters. Installation. Start-Up. Maintenance. Parts. Warranty. CG***N73 / CG***N65 Models

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Your safety and the safety of others are very important.

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Oil and Coolant Circulating Heating System. Model - OCSM

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Installation and Operation Instructions Manual

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

COMMERCIAL GAS WATER HEATERS

INSTALLATION, OPERATION, AND SERVICE MANUAL RESIDENTIAL STORAGE TYPE GAS WATER HEATER

Residential 30, 38, 40, 50 and 60 Gallon

Operator: Save these instructions for future use!

Installation Operation Maintenance

Installation Instructions and Use & Care Guide

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

NFPA31FuelOilPiping 1 Revised

Portable Air Conditioner

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Service Manual. Condensing Boiler. Getting Service

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Gas-Fired, Residential Storage Type Water Heaters

Residential Gas Water Heater with the Flame Guard Safety System Installation Instructions and Use & Care Guide

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Commercial Gas Water Heater

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

INSTANT HOT WATER RECIRCULATING SYSTEM

Please keep this manual for f uture reference.

INSTALLATION & SERVICE MANUAL

!"" #$% "!&' ( ( ) *

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

94% CONDENSING TANKLESS WATER HEATER USE AND CARE MANUAL

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Residential Gas Water Heaters. Residential 30, 38, 40 and 50 Gallon

Transcription:

On-Demand Water Heater Installation Manual and Owner s Guide ANSI Z21. 10.3 and CSA 4.3 model only Models T-KJr2-IN / 110 T-K4-IN / 310 WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Gas Tankless Water Heater TM Suitable for potable water heating and space-heating* * Please refer to local codes for space-heating compliance. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electric switch, do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency or the gas supplier. FEATURING ENDLESS HOT WATER -DEMAND USAGE COMPACT, SPACE SAVING ENERGY CSERVATI COMPUTERIZED SAFETY NO PILOT LIGHT EASY-LINK SYSTEM* COMMERCIAL GRADE COPPER* *( model only) If you have any questions, please call 1-888-479-8324 65Q012-6 REV. 06(04-15)

INSTALLATI MANUAL Table of Contents OWNER'S GUIDE SPECIFICATIS...3 INTRODUCTI...4 SAFETY GUIDELINES....4 Safety Definitions...4 General...4 INSTALLATI...5 General...5 Clearances...7 Included Accessories...7 Optional Items...7 High-altitude Installations...10 Venting Instructions....10 General Exhaust venting Venting Illustrations Vent Termination Clearances Gas supply and gas pipe sizing...15 General Gas Connections Measuring Inlet Gas Pressure Water Connections...15 Pressure Relief Valve Electrical Connections....16 Remote Controller Connections...17 Pump Control Mode...18 Easy-Link System...18 General Easy-Link Connection Procedures APPLICATIS...20 Space-Heating Applications...20 Recirculation...21 Dual-purpose Hot Water Heating...21 With T-D2-IN (510) Model Only INITIAL OPERATI...22 OPERATING SAFETY...23 NORMAL OPERATI...25 General...25 Temperature Settings...25 Without Remote Controller DIP switch Settings for Temperature Flow....26 Freeze protection system...26 Maintenance and Service...27 Unit Draining and Filter Cleaning Descaling the Unit TROUBLESHOOTING...29 General...29 Error Codes....31 Single Unit Installations Easy-Link System Fault Analysis of Error Codes...32 COMPENTS DIAGRAM...35 Case Assembly...35 T-KJr2-IN / 110 T-K4-IN / 310 & Burner Assembly...36 T-KJr2-IN / 110 T-K4-IN / 310 & Computer Board Assembly...38 T-KJr2-IN / 110 & T-K4-IN / 310 Water Way Assembly...38 T-KJr2-IN / 110 Computer Board Assembly...38 Water Way Assembly...38 T-K4-IN / 310 Water Way Assembly...39 Water outlet section...39 Water inlet section....39 PARTS LIST...40 OUTPUT TEMPERATURE CHART...42 T-KJr2-IN Models / 110 T-K4-IN Models / 310 T-D2-IN Models / 510 LIMITED WARRANTY...43 2

SPECIFICATIS Model T-KJr2-IN / 110 T-K4-IN / 310 Natural Gas Input (Operating Range) Min.: 19,500 BTU/h Max.: 140,000 BTU/h Min.: 11,000 BTU/h Max.: 190,000 BTU/h Min.: 11,000 BTU/h Max.: 199,000 BTU/h Propane Input (Operating Range) Min.: 19,500 BTU/h Max.: 140,000 BTU/h Min.: 11,000 BTU/h Max.: 190,000 BTU/h Min.: 11,000 BTU/h Max.: 199,000 BTU/h Gas Connection 3/4 NPT Water Connections 3/4 NPT Water Pressure 15-150 psi* Inlet Natural Gas Min. 5.0 W.C. Max. 10.5 W.C. Pressure Propane Min. 8.0 W.C. Max. 14.0 W.C. Manifold Natural Gas 2.0 W.C. 2.0 W.C. 2.0 W.C. Pressure** Propane 2.5 W.C. 3.7 W.C. 3.7 W.C. Weight 13 kg (28.7 lbs.) 18 kg (39.6 lbs.) 18 kg (39.6 lbs.) Dimensions 520 mm (H) x 351 mm (W) x 170mm (D) 520 mm (H) x 351 mm (W) x 216mm (D) H 20 1/2" x W 13 3/4" x D 6 3/4" H 20 1/2 x W 13 3/4 x D 8 1/2 Ignition Electric Ignition Supply 120 VAC, 60 Hz Electric Consumption Operation 73.1 W / 0.61 A 87.6 W / 0.73 A 89.8 W / 0.75 A Standby 6.2 W / 0.05 A 6.2 W / 0.05 A 6.2 W / 0.05 A Freeze-Protection 111 W / 0.93 A 111 W / 0.93 A 111 W / 0.93 A * 40 psi or above is recommended for maximum flow. ** The Manifold Pressure is the factory setting and generally should not need adjustment. NOTE: Check the rating plate to ensure this product matches your specifications before installation. The manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. 3

INTRODUCTI This manual provides information necessary for the installation, operation, and maintenance of the water heater. The model description is listed on the rating plate which is attached to the side panel of the water heater. Please read all installation instructions completely before installing this product. If you have any problems or questions regarding this equipment, consult the manufacturer or its local representative or call an HVAC technician in your area. This equipment is an on-demand, tankless water heater designed to efficiently supply endless hot water for your needs. The T-KJr2-IN / 110, T-K4-IN / 310, & models are to be installed indoors only (direct-vent convertible). The principle behind tankless water heaters is simple: Exhaust vent collar Heat exchanger SAFETY GUIDELINES Safety Definitions DANGER WARNING CAUTI Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates an imminently hazardous situation which, if not avoided, could result in death or serious injury. Indicates an imminently hazardous situation which, if not avoided, could result in minor or moderate injury. Burners Flow adjustment valve Fan motor Computer board Thermistor Hot Water Outlet Cold Water Inlet Thermistor Gas Valves Flow sensor Gas Inlet * This diagram illustrates tankless water heater design concepts only and does not accurately represent the water heater s physical description. 1. A hot water tap is turned on. 2. Water enters the heater. 3. The water flow sensor detects the water flow. 4. The computer initiates the fan motor and sends a signal to the igniter to create an ignition spark. 5. The igniter starts and the gas valve opens and flames appear within the burner chamber. 6. Water circulates through the heat exchanger and then gets hot. 7. Using thermistors to measure temperatures throughout the water heater, the computer modulates the gas and water valves to ensure proper output water temperature. 8. When the tap is turned off, the unit shuts down. General 1. Follow all local codes, or in the absence of local codes, follow the most recent edition of CSA B149.1 Natural Gas and propane Installation Code. 2. Properly ground the unit in accordance with all local codes or in the absence of local codes, with CSA C22.1 Canadian Electrical Code Part 1. 3. Carefully plan where you intend to install the water heater. Please ensure: Your water heater will have enough combustible air and proper ventilation. Locate your heater where water leakage will not damage surrounding areas. (Please refer to pg. 6,7.) 4. Check the rating plate for the correct GAS TYPE, GAS PRESSURE, WATER PRESSURE and ELECTRIC RATING. * If this unit does not match your requirements, do not install. Consult with the manufacturer. 5. If any problem should occur, turn off all hot water taps and turn off the gas. Then call a trained technician or the Gas Company or the manufacturer. 4

DANGER WARNING Water temperatures over 52 C (125 F) can cause severe burns instantly or death from scalding. The water temperature is set at 50 C (122 F) from the factory to minimize any scalding risk. Before bathing or showering always check the water temperature. Do not store or use gasoline or other flammables, vapors, or liquids in the vicinity of this appliance. Do not reverse the water and/or gas connections as this will damage the gas valves and can cause severe injury or death. Follow the diagram on pg. 16 when installing your water heater. Do not use this appliance if any part has been in contact with or been immersed in water. Immediately call a licensed plumber, a licensed gas fitter, or a professional service technician to inspect and/or service the unit if necessary. Do not disconnect the electrical supply if the ambient temperature will drop below freezing. The Freeze Protection System only works if the unit has electrical power. The heat exchanger will not be covered under warranty if it is damaged due to freezing. Refer to the section on the Freeze Protection System on pg. 26 for more information. 8. Particles from flour, aerosols, clothes dryers and other airborne contaminants may clog the air vent, build up and reduce the functions of the rotating fan, cause improper burning of the gas, or cause damage to the water heater. Regularly ensure that the area around the unit is dust or debris-free. Regular maintenance is recommended for these types of environments. Sealed combustion is recommended too. 9. For the T-KJr2-IN / 110, T-K4-IN / 310, & models: These units may be converted to a direct-vent (sealed combustion) appliance by installing a directvent conversion kit (Part No. TK-TV10) which will bring in all required combustible air from outside the building. When installing the direct-vent conversion kit, please follow all instructions included with the kit. If the water heater is used as a direct-vent appliance, the unit requires a 76mm (3 in.) combustible air supply pipe. The intake pipe must be sealed airtight. Air supply pipe can be made of PVC, CPVC, ABS, Polypropylene, corrugated stainless steel, Category III / IV stainless steel or aluminum flex tube. Terminating the venting through a sidewall is recommended for the direct-vent system. Running the exhaust vent and the intake pipe parallel is recommended. Terminating the exhaust and intake on the same wall/surface is recommended. Terminating in the same pressure zone allows for pressure balancing, which prevents nuisance shutdowns. INSTALLATI General 1. Follow all local codes, or in the absence of local codes, follow the most recent edition of CSA B149.1 Natural Gas and propane Installation Code. 2. All gas water heaters require careful and correct installation to ensure safe and efficient operation. This manual must be followed exactly. Read the Safety Guidelines section. 3. The manifold gas pressure is preset at the factory. It is computer controlled and should not need adjustment. 4. Maintain proper space for servicing. Install the unit so that it can be connected or removed easily. Refer to the "Clearances" section on pg. 7 for proper clearances. 5. The water heater must be installed in a location where the proper amount of combustible air will be available to it at all times without obstructions. 6. The electrical connection requires a means of disconnection, to terminate power to the water heater for servicing and safety purposes. 7. Do not install the unit where the exhaust vent is pointing into any opening in a building or where the noise may disturb your neighbors. Make sure the vent termination meets the required distance by local code from any doorway or opening to prevent exhaust from entering a building. (Refer to pg. 13, CSA B149.1.) 5

WARNING Installation and service must be performed by a qualified installer (for example, a licensed plumber or gas fitter), otherwise the warranty will be void. The installer (licensed professional) is responsible for the correct installation of the water heater and for compliance with all national, state / provincial, and local codes. The manufacturer does not recommend installing the water heater in a pit or location where gas and water can accumulate. Do not have the vent terminal pointing toward any operating window, door, or opening into a building. Do not install next to any source of airborne debris, such as a clothes dryer, that can cause debris to be trapped inside the combustion chamber, unless the system is direct-vented. The manufacturer does not recommend installing the water heater in an attic due to safety issues. If you install the water heater in an attic: Make sure the unit will have enough combustion air and proper ventilation. Keep the area around the water heater clean. When dust collects on the flame sensor, the water heater will shut down on an error code. If the above conditions cannot be met, use the direct-vent conversion kit TK-TV10. Place the unit for easy access for service and maintenance. A drain pan, or other means of protection against water damage, is required to be installed under the water heater in case of leaks. CAUTI The warranty will not cover damage caused by water quality. Only potable water can be used with this water heater. Do not introduce pool or spa water, or any chemically treated water into the water heater. Water hardness levels must not exceed 7 grains per gallon (120 ppm) for single family domestic applications or more than 4 grains per gallon (70 ppm) for all other types of applications. Water hardness leads to scale formation and may affect/ damage the water heater. Hard water scaling must be avoided or controlled by proper water treatment. Water ph levels must be between 6.5 and 8.5 Well water must be treated. Do not install the unit where water, debris, or flammable vapors may get into the flue terminal. The manufacturer recommends using the direct-vent conversion kit when the water heater is installed in a beauty salon or anywhere there are airborne contaminants. Some chemicals used in a beauty salon may affect the flame sensor. Water heater may not work properly. Although the water heater is designed to operate with minimal sound, the manufacturer does not recommend installing the unit on a wall adjacent to a bedroom, or a room that is intended for quiet study or meditation, etc. Locate your heater close to a drain where water leakage will not do damage to surrounding areas. As with any water heating appliance, the potential for leakage at some time in the life of the product does exist. The manufacturer will not be responsible for any water damage that may occur. If you install a drain pan under the unit, ensure that it will not restrict the combustion air flow. 6

WARNING FOR INSTALLATI LOCATIS Do not install the heater where water, debris or flammable vapors may get into the flue terminal. This may cause damage to the heater and void the warranty. Do not have the vent terminal pointing toward any opening into a building. Do not locate your heater in a pit or location where gas and water can accumulate. Do not install this water heater vent terminator within 914 mm (3 ft.) of any air intake or building opening. Prohibited WARNING (Refer to p.13.) 914 mm (3 ft.) Do not install next to a dryer or any source of airborne debris that can be trapped inside the combustion chamber, unless the system is direct-vented. Clearances Model Top Bottom Front Back Sides T-KJr2-IN / 305mm 305mm 102mm* 25mm 76mm 110 (12 in.) (12 in.) (4 in.) (1 in.) (3 in.) T-K4-IN / 305mm 305mm 102mm* 25mm 76mm 310 (12 in.) (12 in.) (4 in.) (1 in.) (3 in.) T-D2-IN / 305mm 305mm 102mm* 25mm 76mm 510 (12 in.) (12 in.) (4 in.) (1 in.) (3 in.) *610 mm (24 inches) recommended for maintenance. V Vent Terminal 914 mm (3 ft.) 914 mm (3 ft.) Maintain all clearances around the water heater. The diagram of clearance Included Accessories Check that these items below are included with the water heater. Items Installation Manual & Owner s Guide Communication Cable ( models only) Temperature remote controller Optional Items Model Universal Appliance Adapter (9008146005) (2SVBFDPA04) T-KJr2-IN /110 &T-K4-IN /310 Qty: 1 Qty: 1 TK-RE02 Qty: 1 T-D2-IN /510 TM-RE30 Qty: 1 T-KJr2-IN / 110 T-K4-IN / 310 T-D2-IN / 510 x x x TK-TV10 x x x TK-PC01 x x TK-PCJr2 x Sidewall vent terminator(hood) / Termination Box & Wall thimble x x x Direct-vent concentric termination kit (2SVSHTCKIT43S or 2SVSHTCKIT43) TK-IV01-AB (Isolation valve kit) Side Front Top Bottom Back Side x x x x x x 7

1. Temperature remote controller: TK-RE02 Please refer to the remote controller manual supplied with the remote. The temperature remote controller has two functions. It allows the output temperature from the water heater to be adjusted within the range of 37.5 C to 75 C (99 F to 167 F)*, and it also works as a diagnostic tool that will give a concise error code whenever there is a problem with the unit. The temperature options are 37.5 C (99 F), 38 C (100 F), 39 C (102 F), 40 C (104 F), 41 C (106 F), 42 C (108 F), 43 C (110 F), 44 C (111 F), 45 C (113 F), 46 C (115 F), 47 C (117 F), 50 C (122 F), 55 C (131 F), 60 C (140 F), 70 C (158 F), and 75 C (167 F). See the troubleshooting section for information on possible error codes. *The remote only provides the temperature display in Fahrenheit. 2. Temperature remote controller: TM-RE30 Please refer to the remote controller manual supplied with the remote. The temperature remote controller has two functions. It allows the output temperature from the water heater to be adjusted within the range of 37 C to 85 C (100 F to 185 F), and it also works as a diagnostic tool that will give a concise error code whenever there is a problem with the unit. The temperature options are 37 C (100 F), 38 C (100 F), 39 C (102 F), 40 C (104 F), 41 C (106 F), 42 C (108 F), 43 C (110 F), 44 C (111 F), 45 C (113 F), 46 C (115 F), 47 C (117 F), 50 C (122 F), 55 C (131 F), 60 C (140 F), 65 C (149 F), 70 C (158 F), 75 C (167 F), 80 C (176 F). See the troubleshooting section for information on possible error codes. 3. 4 inches universal appliance adapter with back flow preventer and condensation drain: 9008146005 / 2SVBFDPA04 There are three functions available for this adaptor, which can be connected with the water heater and Flex master venting line and prevents the backflow of air through the exhaust vent. This helps prevent harmful exhaust gases from entering the home, as well as helping to prevent the unit from freezing in areas where cold air can be blown or drawn into the exhaust system. Furthermore condensation drain from the combustion is discharged. Install this adaptor in accordance with the installation instructions that are packaged with the adaptor and any applicable codes. 4. Direct-vent conversion kit: TK-TV10 This kit can be used to convert the water heater from a standard vent system to a direct-vent (or sealed combustion) system. Install this conversion kit in accordance with the installation instructions and any applicable codes. 5. Pipe Covers: TK-PC01 and TK-PCJr2 The pipe cover protects the plumbing pipes to the water heater from unexpected adjustments. This pipe cover is fixed to the bottom of the water heater, which hides the plumbing and improves the visual aspects of the whole installation for the water heater. 8

6. Wall thimble and Sidewall vent terminations They are used when venting out through the wall. These terminations are special stainless steel vents for gas appliances and are UL listed as Category II, III and IV. For different wall thicknesses, there are two ranges of lengths available. (Refer to the Flexmaster brochure for details.) Install these vent terminations in accordance with their installation instructions and any applicable local code. Wall thimble Termination Hood Covering wall thicknesses Wall Thimble 4-7 in. Wall Thimble 5-10 in. Termination Hood Termination Box Part# 2SVSWTF04 2SVSWTEF04 2SVSHTX04 2SVSRTF04 Termination Box 7. Direct-vent concentric termination kit Used when terminating direct-vent (sealed combustion) systems, with indoor models that require a 3 in. (76 mm) intake and a 4 in. (102 mm) exhaust. This concentric termination provides the convenience of only having to make one penetration through a sidewall instead of two separate penetrations for the intake and exhaust piping. The termination includes a bird screen, restricting small animals, pests, and foreign objects from entering into the vent system. This sidewall termination is available in two different sizes, to cover a wide range of wall thicknesses. For different wall thicknesses, there are two ranges of lengths available. (Refer to the Flexmaster brochure for details.) Covering wall thicknesses Part# 6.75 13.0 in. 2SVSHTCKIT43S 12.25 19.25 in. 2SVSHTCKIT43 8. Isolation valve kit: TK-IV01-AB The kit uses Isolation Valves to isolate a unit for service. The Pressure Relief Valve is to help protect the unit and release if the pressure in the tankless water heater or hot water system exceeds 150 psi. 9

High-altitude Installations Check the elevation where your water heater is installed. Set DIP switches shown in the table below depending on the altitude. T-KJr2-IN / 110 & T-K4-IN / 310 Models Altitude Switch No. 3 Switch No. 4 0 to 2,000 ft (DEFAULT) 2,001 to 4,000 ft 4,001 to 6,000 ft OFF OFF OFF OFF 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Model (Left bank of DIP switches) Altitude Switch No. 4 Switch No. 5 0 to 2,000 ft (DEFAULT) 2,001 to 4,000 ft 4,001 to 6,000 ft OFF OFF OFF OFF 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 The dark squares indicate the direction the DIP switches should be set to. The maximum certified or allowable installed altitude is 6,000 ft. T-KJr2-IN / 110 & T-K4-IN / 310 Computer board Computer board CAUTI When installing the vent system, all applicable national and local codes must be followed. If you install thimbles, fire stops or other protective devices and they penetrate any combustible or noncombustible construction, be sure to follow all applicable national and local codes. The water heater must be vented in accordance with the section Venting of Equipment" of the latest edition of CSA B149.1 Natural Gas and propane Installation Code as well as applicable local building codes. The manufacturer recommends the Flexmaster line. However, the following are also UL listed manufacturers: ProTech Systems Inc. (FasNSeal), Metal-Fab Inc., and Heat-Fab Inc. (Saf-T Vent). General rules for venting water heaters are: Place the water heater as close as possible to the vent termination. The vent collar of the water heater must be fastened directly to an unobstructed vent pipe. Do not weld the vent pipe to the water heater s vent collar. Do not cut the vent collar of the water heater. The vent must be easily removable from the top of the water heater for normal service and inspection of the unit. Avoid using an oversized vent pipe or using extremely long runs of the pipe. For rooftop venting, a rain cap or other form of termination that prevents rain water from entering into the water heater must be installed. Do not common vent or connect any vent from other appliances to the water heater vent. WARNING DIP switches DIP switches (Left bank) DO NOT adjust any DIP switches on the right bank for the model. Venting Instructions General DANGER Improper venting of this appliance can result in excessive levels of carbon monoxide which can result in severe personal injury or death. Improper installation can cause nausea or asphyxiation, severe injury or death from carbon monoxide and flue gases poisoning. Improper installation will void product warranty. General rules for vent terminations: Avoid locating the water heater vent termination near any air intake devices. These fans can pick up the exhaust flue products from the water heater and return them to the building. This can create a health hazard. Locate the vent termination so that it cannot be blocked by any debris, at any time. Most codes require that the termination be at least 305 mm (12 in.) above grade, we recommend that it be at least 305 mm (12 in.) above the anticipated snow line, but the installer may determine that it should be higher, depending on the job site condition and applicable local codes. A proper sidewall termination is recommended when the water heater is vented through a sidewall. Regarding the clearances from the exhaust termination to the air inlet or opening, refer to the next few pages. 10

Exhaust venting This is a Category III appliance and must be vented accordingly. The vent system must be sealed airtight. All seams and joints without gaskets must be sealed with high heat resistant silicone sealant or UL listed aluminum adhesive tape having a minimum temperature rating of 177 C (350 F). For best results, a vent system should be as short and straight as possible. This water heater is a Category III appliance and must be vented accordingly with any 102 mm (4 in.) vent approved for use with Category III or Special BH type gas vent. Follow the vent pipe manufacturer s instructions when installing the vent pipe. Do not common vent this appliance with any other vented appliance. (Do not terminate vent into a chimney. If the vent must go through the chimney, the vent must run all the way through the chimney with Category III approved or Special BH vent pipe.) When the horizontal vent run exceeds 1.5 m (5 ft.), support the vent run at 0.9 m (3 ft.) intervals with overhead hangers. The maximum length of exhaust vent piping must not exceed 15.24 m (50 ft.) (deducting 1.5 m (5 ft.) for each elbow used in the venting system). Do not use more than 5 elbows. Max. No. of Max. Vertical & Horizontal Diameter Elbows (Total) Vent Length 102 mm (4 in.) 5 15.24 m (50 ft.) * For each elbow added, deduct 1.5 m (5 ft.) from max. vent length. Venting Illustrations For details of the optional items, refer to the Installation manual for each Optional item. Horizontal Installation Diagram: Vertical condensation drain** Backflow preventer* Hanger Sidewall vent termination Vertical Installation Diagram: Roof Wall Rain cap Storm collar Roof flashing No. of Max. Vertical or Horizontal Length Elbows 0 15.24 m (50 ft.) 1 13.7 m (45 ft.) 2 12.2 m (40 ft.) 3 10.7 m (35 ft.) 4 9.1 m (30 ft.) 5 7.6 m (25 ft.) Excludes elbow termination, rain caps, or the 102 mm (4 in.) Concentric Termination, Termination Hood and Termination Box. Hanger Backflow Preventer* Vertical condensation drain** Fire stop 11

Horizontal Installation Diagram (with direct-venting) Wall Horizontal Installation Diagram with Direct-Vent Concentric Termination Wall Vertical condensation drain** Sidewall vent terminations Backflow preventer* See the picture below for detailed connection instructions to the Direct-vent conversion kit. Vertical Installation Diagram (with direct-venting) Roof flashing Rain cap Direct-vent concentric termination Roof Installation Diagram of Direct-Vent Conversion Kit (TK- TV10) with a water heater Roof flashing Air intake cover plate Storm collar Fire Stop Hanger Remove the air intake cover plate to attach the air intake port from the Direct-vent conversion kit. (TK-TV10) Backflow preventer* Vertical condensation drain** See the picture below for detailed connection instructions to the direct-vent conversion kit. * Backflow preventer (Recommended for freezing weather conditions: 2 C (36 F) and below). ** Vertical condensation drain must be installed in accordance with local codes. Cover the louver of the water heater with the plate provided in the Direct-vent conversion kit to complete the conversion to sealed combustion. 12

Vent Termination Clearances Canada U.S.A Direct-vent and other than Direct-vent Directvent Other than Direct-vent A Clearance above grade, veranda, porch, deck, or balcony 1 foot 1 foot 1 foot 4 feet from below or B Clearance to window or door that may be opened 3 feet 1 foot side opening. 1 foot from above opening. C Clearance to permanently closed window * * * D Vertical clearance to ventilated soffit located above the vent terminator within a horizontal distance of 2 feet (61cm) from * * * the center line of the terminator E Clearance to unventilated soffit * * * F Clearance to outside corner * * * G Clearance to inside corner * * * H Clearance to each side of center line extended above meter/regulator assembly 3 feet * * I Clearance to service regulator vent outlet 3 feet * * J 4 feet from below or Clearance to non-mechanical air supply inlet to building or 3 feet 1 foot side opening. 1 foot the combustion air inlet to any other application from above opening. K Clearance to mechanical air supply inlet. 6 feet 3 feet 3 feet L Clearance above paved sidewalk or paved driveway located on public property 7 feet * 7 feet M Clearance under veranda, porch deck, or balcony 1 foot * * * For clearances not specified in CSA B149.1 Natural Gas and propane Installation Code, please use clearances in accordance with local installation codes and the requirement of the gas supplier. 13

CAUTI Please follow all local and national codes in regards to proper termination clearances. In the absence of such codes, the following clearances can be used as guidelines. Local codes supersede these guidelines. For rooftop terminations A A A For sidewall terminations 305 mm (1 ft.) 305 mm (1 ft.) 610 mm (2 ft.) Exhaust terminations Inside corner 915 mm (3 ft.) 915 mm (3 ft.) 610 mm (2ft.) Direct-vent terminations Inside corner For multiple sidewall exhaust For multiple-unit, directvent sidewall terminations terminations (e.g. Multi- Unit systems), an exhaust that combine the intake termination must be at least and exhaust into a single 305 mm (1 ft.) away from penetration, space each another exhaust termination. direct-vent termination at An exhaust termination must least 915 mm (3 ft.) away also be at least 610 mm from each other, no matter (2 ft.) away from an inside the orientation. A direct-vent corner. (If the adjacent wall termination must also be at is less than 610 mm (2 ft.) of least 610 mm (2 ft.) away length, the minimum required from an inside corner. (If the distance away from the inside adjacent wall is less than corner will be equal to the 610 mm (2 ft.) of length, the length of that adjacent wall.) minimum required distance away from the inside corner will be equal to the length of that adjacent wall.) 610 mm (2 ft.) Exhaust termination B Exhaust termination A A Air intake Air intake A: In accordance with local codes For multiple-unit rooftop terminations (whether for standard or direct-vent installations) space all exhaust and intake terminations in accordance with local codes. An exhaust termination must be spaced from a wall or surface in accordance with local codes as well. B: An exhaust termination shall extend not less than 915 mm (3 ft.) above the highest point where it passes through the roof of a building AND NOT less than 610 mm (2 ft.) higher than any portion of a building within a horizontal distance of 3048 mm (10 ft.). (CSA B149.1 8.14.4) 3 ft. 3 ft. 3 ft. 2 ft. Air supply inlet Exhaust termination For direct-vent sidewall Exhaust and/or direct-vent terminations that use two sidewall terminations should separate penetrations for the be at least 610 mm (2 ft.) intake and exhaust, distance away from an opposite the intake and exhaust surface/wall. Do not place terminations at least 915 mm the termination directly in (3 ft.) away from each other, front of an opening into a no matter the orientation. building. 14

Gas supply and gas pipe sizing General WARNING Check that the type of gas matches the rating plate first. Ensure that any and all gas regulators used are operating properly and providing gas pressures within the specified range shown below. Excess gas inlet pressure may cause serious accidents. Conversion of this unit from natural gas to propane or vice versa will void all warranty. Contact your local distributor to get the correct unit for your gas type. The manufacturer is not liable for any property and/or personal damage resulting from gas conversions. The minimum and maximum inlet gas pressures are: Gas type Inlet gas pressure Natural Gas Min. 5.0 W.C. Max. 10.5 W.C. Propane Gas Min. 8.0 W.C. Max. 14.0 W.C. Inlet gas pressures that fall outside the range of values listed above may adversely affect the performance of the water heater. These pressures are measured when the water heater is in full operation. Inlet gas pressure must not exceed the above maximum values; gas pressure above the specified range will cause dangerous operating conditions and damage to the unit. Until testing of the main gas line supply pressure is completed, ensure the gas line to the water heater is disconnected to avoid any damage to the water heater. Gas Connections 1. Install a manual gas shutoff valve between the water heater and the gas supply line. 2. When the gas connections are completed, it is necessary to perform a gas leak test (see below) either by applying soapy water to all gas fittings and observing for bubbles or by using a gas leak detection device. The water heater and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kpa). The water heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5kPa). 3. Always purge the gas line of any debris, inert gas* and/ or water before connecting to the gas inlet. * Inert gas may be left in the line from pressure testing. Note: Size the gas pipe appropriately to supply the necessary volume of gas required for the water heater using CSA B149.1 Natural Gas and propane Installation Code or local codes. Otherwise, flow capabilities and output temperatures may be limited. The installation shall comply with CSA B149.1 Natural Gas and propane Installation Code. Measuring Inlet Gas Pressure 1. Turn off all electric power to the water heater if service is to be performed. 2. Turn the manual gas valve located on the outside of the unit clockwise to the off position. The water heater cannot perform properly without sufficient inlet gas pressure. Below are instructions on how to check the inlet gas pressure. THIS IS LY TO BE DE BY A LICENSED PROFESSIAL. 1. Shut off the manual gas valve on the supply gas line. 2. Remove the screw for the pressure port located on the gas inlet of the water heater shown in the diagram below. 3. Connect the manometer to the pressure port. 4. Re-open the manual gas valve. Check to see that there are no gas leaks. Take a reading of the gas pressure. Open some of the fixtures that use the highest flow rate to turn on the water heater. 5. Check the inlet gas pressure. Take another reading. When the water heater is on maximum burn, the manometer should read from 5.0 to 10.5 W.C. for Natural gas or from 8.0 to 14.0 W.C. for Propane. Verify drop meets code. Water Connections CAUTI Pressure port Do not use this water heater if any part has been submersed under water. Immediately call a licensed professional to inspect the water heater to replace any damaged parts. Do not reverse the hot outlet and cold inlet connections to the water heater. This will not properly activate the water heater. All pipes, pipe fittings, valves and other components, including soldering materials, must be suitable for potable water systems. 1. A manual shutoff valve must be installed on the cold water inlet to the water heater between the main water supply line and the water heater. 15

2. In addition, a manual shutoff valve is also recommended on the hot water outlet of the unit. If the water heater is installed within, or subjected to, a closed loop water system, a thermal expansion tank must be installed on the return side. We recommend isolation valve sets with hose bibs for serviceability such as flushing. See maintenance section. 3. Before installing the water heater, flush the water line to remove all debris, and after installation is complete, purge the air from the line. Failure to do so may cause damage to the heater. 4. There is a wire mesh filter within the cold inlet to trap debris from entering your heater. This will need to be cleaned periodically to maintain optimum flow. Electrical Connections WARNING CAUTI Follow the electrical code requirements of the local authority having jurisdiction. In the absence of such requirements, follow the latest edition of CSA C22.1 Canadian Electrical Code, Part 1. When servicing or replacing parts within the water heater, label all wires prior to disconnection to facilitate an easy and errorfree re-connection. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. As close as possible 1. The water heater requires 120 VAC, 60 Hz electrical power supply that is properly grounded. 2. The use of a surge protector is recommended in order to protect the unit from power surges. Pressure Relief Valve Hot outlet Cold inlet Gas inlet Pressure Relief Valve The water heater has a high-temperature shutoff switch built in as a standard safety feature (called a Hi-Limit switch) therefore a pressure only relief valve is required. This unit does not come with an approved pressure relief valve. An approved pressure relief valve must be installed on the hot water outlet. The pressure relief valve must conform to CAN 1-4.4 and installation must follow local codes. The discharge capacity must be at least 140,000 BTU/h for the T-KJr2-IN / 110, 190,000 BTU/h for the T-K4-IN / 310, and 199,000 BTU/h for the. The pressure relief valve needs to be rated for a maximum of 150 psi. The discharge piping for the pressure relief valve must be directed so that the hot water cannot splash on anyone or on nearby equipment. Follow local codes. Attach the discharge tube to the pressure relief valve and run the end of the tube to within 152 mm (6 in.) from the floor. This discharge tube must allow free and complete drainage without any restrictions. If the pressure relief valve installed on the water heater discharges periodically, this may be due to a defective thermal expansion tank or defective pressure relief valve or it could be signs of internal scale build up. The pressure relief valve must be manually operated periodically to check for correct operation. No valve may be placed between the relief valve and the water heater. 16

Remote Controller Connections To connect the remote controller to the water heater: 1. Disconnect power supply from the water heater. 2. Take off the water heater s front cover. 3. Wires used for the remote controller connection must be: Minimum 20 gauge wire (No polarity) T-KJr2-IN / 110 & T-K4-IN / 310 models (TK-RE02) Maximum 45 m (150 ft.) long model (TM-RE30) Maximum 122 m (400 ft.) long * For detailed connection to the remote controller, refer to the instructions that are packaged with the remote controller. 4. Pick location of install for the remote controller. 5. Cut enough two pair wire. 6. Crimp on supplied fork connectors. 7. Locate the remote controller terminals, pictured below (located around the lower right-hand side of the computer board). 8. Open the plastic cover of the remote controller, and then attach the two fork terminals to connector base of the backside of the remote controller with two screws. Make sure the terminals are firmly fixed. 9. Pull the remote s wires through the hole at the bottom of the water heater s casing. 10.Properly attach the remote s wires to the remote controller terminals on the computer board. (No polarity) * Do NOT jump or short-circuit the wires, or the computer board will be damaged. 11. Replace the plastic computer board cover and then replace the front cover securely. NOTE*: If the model is used in an Easy-Link System, the remote MUST be connected to the Parent unit. Only one remote controller is needed in an Easy-Link System. T-KJr2-IN / 110 & T-K4-IN / 310 models TK-RE02 Connect to these terminals Front of remote controller Back of remote Connect to these terminals T-D2-IN /510 model TM-RE30 Connect to these terminals Front of remote controller Back of remote Connect to these terminals 17

Pump Control Mode (Available on the model only) The water heaters can be used to control a recirculation pump. Proper pump control helps to preserve the life of the system and saves energy as well. The water heater pump control port is a normally-open dry contact, and therefore needs additional components to properly control a recirculation pump. To control a recirculation pump, connect the pump to the Pump connector in the water heater as shown in the diagram below. (In an Easy-Link System, connect the pump LY to the PARENT unit.) The pump is to be connected using suitable relays shown in the diagram below. Please make sure the relays are properly rated for the recirculation pump. Using the water heater s internal thermistors as a temperature control, the recirculation pump will only turn on when recirculation is needed. CAUTI Recirculation pump In an Easy-Link System, the pump must be connected to the Pump connector in the PARENT unit only. If the pump is connected to any of the CHILD units, the pump will not work. Thermal relay for additional safety 120 VAC 220 VAC etc for relay Connect to this Pump connector These components are NOT included with the water heater and are external to the unit. They must be acquired separately. Power supply for pump 120 VAC 220 VAC etc Easy-Link System (Available on the model only) Power supply for relay General The water heaters can be connected with other heaters of the same model with communication cables to work as a multiple-unit manifold system. The Easy-Link System allows up to 4 units to manifold together. 18 A communication cable (gray color) comes with each model. You can manifold from 2 to 4 units without the need for a Multi-Unit Controller. A 4-unit system has full automatic modulation between 11,000 BTU/h and 796,000 BTU/h. Gas In Cold In CAUTI Hot Out The Easy-Link System is limited up to 4 units. If you connect more than 4 units, only the first 4 units will work as a part of the Easy-Link System. The other additional units will not work correctly and fluctuating water temperatures or no hot water may be a result. All units within an Easy-Link System must be of the same exact model. Easy -Link System is backward compatible with the T-K3 and T-K3 Pro, no other models cannot be combined together to form an Easy-Link System. Only change DIP switch settings with power off. Easy-Link Connection Procedures 1. Make sure the power to the water heaters are off. 2. Verify the set temperatures of all units within the system. Every single water heater must be set to the same set temperature. See *Note on the next page. 3. Select one unit to be the PARENT unit with power off. 4. PARENT unit: Locate the two banks of DIP switches at the right of the 7-Seg LED on the computer board of the unit that you select to be the PARENT unit. Change DIP switch No. 1 on the right bank of DIP switches to the position. See the computer board diagram as shown in the next page. Do not change any DIP switches on any of the CHILD units. 5. Between the PARENT and the CHILD-1 units: Connect the PARENT connector of the PARENT unit to the 1 connector of the CHILD-1 unit. 6. Between the CHILD-1 and the CHILD-2 units: Connect the 2 connector of the CHILD-1 unit to the 1 connector of the CHILD-2 unit. 7. Between the CHILD-2 and the CHILD-3 units: Connect the 2 connector of the CHILD-2 unit to the 1 connector of the CHILD-3 unit.

8. Make sure the 7-Seg LED of all the units computer boards display the unit #. The numbering system automatically allocates the unit # to each water heater in the Easy-Link System, in accordance with the table below. Parent unit Unit #: 1 Child units Unit #: 2, 3 or 4 (A) Computer board (C) Examples of incorrect settings and/or connections CASE 1: Unless you change DIP switch No. 1 of the PARENT unit to the position, the system will not work as an Easy-Link System. The units will operate as individual units. Connectors PARENT unit 2 Connectors CHILD-1 unit 2 Easy-Link System Online LED Left bank of DIP switches Wrong setting Right bank of Dipswitches 1 2 3 4 5 6 OFF 1 PARENT Right bank of Dipswitches 1 2 3 4 5 6 OFF 1 PARENT 7-Seg. LED Communication cable Right bank of DIP switches Easy-Link connectors are next to the computer board. To change the DIP switch settings for the Easy-Link System, locate the bank of DIP switches at the right of the 7-Seg LED. Do not adjust the left bank of DIP switches. Prohibited Wrong DIP switch setting on the PARENT unit (B) Basic diagram of connections between the Easy-Link System units. Connectors PARENT unit 2 Connectors CHILD-1 unit 2 Connectors CHILD-2 unit 2 Connectors CHILD-3 unit 2 CASE 2: If you connect the 1" (or "2") connector of the PARENT unit to the PARENT" (or "1") connector of the CHILD-1 unit, the system will not work as an Easy-Link System. The units will operate as individual units. PARENT PARENT Right bank of Dipswitches 1 2 3 4 5 6 OFF Right bank of Dipswitches 1 2 3 4 5 6 OFF Communication cable 1 1 PARENT Right bank of Dipswitches 1 2 3 4 5 6 OFF Right bank of Dipswitches 1 2 3 4 5 6 OFF 1 1 PARENT PARENT unit CHILD-1 unit Connectors 2 1 Connectors 2 1 Wrong connection PARENT PARENT The dark squares indicate the direction the DIP switches should be set to. Wrong connection Right bank of Dipswitches 1 2 3 4 5 6 OFF Communication cable Right bank of Dipswitches 1 2 3 4 5 6 OFF CAUTI OR *Note: A remote controller is not required for the Easy-Link System. If running the Easy-Link System without a remote controller, please make sure the temperature settings on ALL the units are set to the same settings. Otherwise, the units will not operate properly. If a remote controller is used, the temperature on all the units in the system will automatically be set to the same temperature that is set on the remote. Wrong connection Connectors Right bank of Dipswitches 1 2 3 4 5 6 OFF PARENT unit 2 1 PARENT Communication cable Connectors Right bank of Dipswitches 1 2 3 4 5 6 OFF CHILD-1 unit 2 1 PARENT Wrong connection Wrong connections between the PARENT unit and the CHILD-1 unit Prohibited 19

CASE 3: If you connect the PARENT connector of the CHILD- 1 unit to the 1 connector of the CHILD-2 unit, the CHILD-2 unit will operate as an individual unit, and will not be part of the Easy-Link System. Connectors Right bank of Dipswitches 1 2 3 4 5 6 OFF PARENT unit 2 1 PARENT Communication cable Prohibited WARNING Connectors Right bank of Dipswitches 1 2 3 4 5 6 OFF CHILD-1 unit 2 1 PARENT Connectors Right bank of Dipswitches 1 2 3 4 5 6 OFF CHILD-2 unit 2 1 PARENT Wrong connection Wrong connections between the CHILD-1 unit and the CHILD-2 unit Connecting two PARENT connectors together from two separate units may damage the computer board. The communication cable has a female end and a male end so it s impossible to have a PARENT-to-PARENT connection with the communication cable. Do not splice or modify connectors. CASE 4: If a remote controller is used, it has to be connected to the PARENT unit. If the remote controller is connected to a CHILD unit, it will only control that particular individual CHILD unit and will not control the Easy-Link System as a whole. APPLICATIS Space-Heating Applications WARNING In order to purge air in water pipes within a closed-loop system, an air vent and air separator should be installed in the system. Required circulation flow rates are labeled next to each application diagram. These flow rate requirements must be followed. Toxic chemicals used in boiler treatments such as alcohol, glycerol and glycol groups must not be introduced into the system if the system incorporates an open-loop potable water system. The water heater can be used to supply potable water and space heating and shall not be connected to any heating system or component(s) previously used with nonpotable water where any chemicals were added to the water heating appliances. Water heaters for combination water/ space heating cannot be used in space heating applications only. When the system requires water for space heating at temperatures higher than required for other uses, a means such as a mixing valve shall be installed to temper the water for those other uses in order to reduce scald hazard potential. Water temperature over 52 C (125 F) can cause severe burns instantly or death from scalding. Connectors PARENT unit Connectors CHILD-1 unit Remote controller 2 2 1 1 PARENT PARENT Right bank of Dipswitches 1 2 3 4 5 6 OFF Communication cable Right bank of Dipswitches 1 2 3 4 5 6 OFF Wrong connection Remote controller connected to incorrect unit Prohibited 20

Recirculation The recirculation pump is to be controlled by: Dual-set aquastat (recommended w/timer) OR Pump Control Mode (T-D2-IN / 510 Models only). Refer to pg. 18. The recirculation pump is to provide no less than 7.5 L/min (2 GPM (US)) and no more than 15 L/min (4 GPM (US)) through each activated unit in the system. Hot water outlet to fixtures Recirculation pump S Air separator Air vent Check valve Pressure relief valve Hot water outlet Check valve Cold water inlet Gas inlet Unions Ball valves Gas supply Expansion tank Y-Strainer Cold water inlet Dual-purpose Hot Water Heating with Model Only (Domestic and Space Heating): Diagramatic layout of Radiant Heating and Domestic Water Heater. The recirculation pump is to provide no less than 7.5 L/min (2 GPM (US)) and no more than 15 L/min (4 GPM (US)) through each activated unit in the system. Automatic tempering device must be installed below the top of the water heater as per manufacturer s recommendations. Piping loop between water heater and fan coil Heating Coil (used with air-handler) Thermostatic mixing valve Apply correct thermal expansion tank-size per application. Tempered water to plumbing fixtures. Follow local code. Shut-off valves Cold water supply Shut-off valve Pressure gauge Check valves P Check valve will have 1/8" hole drilling in clapper optional. Atmospheric vacuum breaker Hot water supply and return to heating coil Unions Ball valve Hot water outlet Drain plug Cold water inlet Water filter 4" gas exhaust vent (Discharge must comply with local and state codes). Cannot be common vented with other appliances. Gas inlet Unions 120 VAC switch or outlet System installed with reverse acting aquastat to shut off fan 50-0 maximum distance from water heater to fan coil (Developed length) Not including coil in heating unit. Shut-off valves T Check valve NSF-61 product approved pump Electronically controlled pump timer. Activates every 6 hours for 60 seconds. Wire to product approved pump. The built in Pump control may also be used to control pump. Readily accessible T-handle gas shut-off valve An approved temperature and pressure relied valve, tie to location approved by local codes and Must meet BTU rating of water heater model used. Note: Priority Control Devices such as a flow switch, an Aquastat or other electronic controller can be used to prioritize the domestic water system over the heating system. Follow all local codes. This illustration is a concept design only. There are a wide variety of variations to the application of controls and equipment presented. Designers must add all necessary safety and auxiliary equipment to conform to code requirements and design practice. For more details, contact the manufacturer. 21