Operating Instructions Air Conditioner



Similar documents
Operating Instructions Air Conditioner

Operating Instructions

Operating Instructions

Operating Instructions Split System Air Conditioner

Instruction manual for Firstline FCS12000CH

Split Type Room Air Conditioner. KSWM units

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

OPTIONAL SLENDER REMOTE CONTROL

Portable Air Conditioner

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Use and Care Manual. Model CPA12KH AIR CONDITIONER

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

INDOOR UNIT/OUTDOOR UNIT

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

Meaco 30L and Meaco 40L dehumidifier instruction manual

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

AIR CONDITIONER (SPLIT TYPE)

PORTABLE AIR CONDITIONER

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

R410A SPLIT SERIES DC INVERTER

Before using your air conditioner, please read this manual carefully and keep it for future reference. ROOM AIR CONDITIONER

DAIKIN ROOM AIR CONDITIONER FT50BSG FT60BSG MODELS. Operation Manual

Split Air Conditioner

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Contents. Correct Disposal of This Product (Waste Electrical & Electronic Equipment)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

DAIKIN ROOM AIR CONDITIONER MODELS. Operation Manual ENGLISH ESPAÑOL TURKISH

WINDOW ROOM AIR CONDITIONER

Room Air Conditioners

LG Wireless Remote Controller

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

LG Floor Standing-Type Air Conditioner OWNER'S MANUAL

SYSTEM Inverter Air Conditioners

LG Multi Type Air Conditioner

INDOOR UNIT/OUTDOOR UNIT

Contents. PREPARING YOUR AIR CONDITIONER Safety Precautions... 3 View of the Indoor unit... 8

DUCT TYPE AIR CONDITIONER

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

SAFEGUARDING THE ENVIRONMENT

OMI-09/OMO-09 OMI-12/OMO-12 OMI-18/OMO-18 OMI-24/OMO-24. Wall Mounted Unit

Inverter Single Zone Ductless Mini Split Heat Pump

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Important Safeguards

OPERATING INSTRUCTIONS INDOOR UNIT MSZ-A18YV MSZ-A24YV MSZ-A26YV MSZ-A30YV

Air Conditioner CONTENTS CS-V7DKE CU-V7DKE CS-V9DKE CU-V9DKE CS-V12DKE CU-V12DKE. Order No. MAC C2

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Operating Instructions Split System Air Conditioner

DAIKIN ROOM AIR CONDITIONER FTKD50BSG FTKD60BSG FTKD71BSG MODELS. Operation Manual

USER S MANUAL HSC-24A

SPLIT TYPE AIR CONDITIONER INDOOR UNIT MODEL RAK-18QH8(W) RAK-25QH8(W) RAK-35QH8(W) RAK-50QH8(W) RAK-18QH8(B) RAK-25QH8(B) RAK-35QH8(B) RAK-50QH8(B)

LG Room Air Conditioner OWNER'S MANUAL

Split Air Conditioner

RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E RAV-SM1604UT-E

PORTABLE AIR CONDITIONER

Owner s Manual AIR CONDITIONER (SPLIT TYPE) Indoor Unit RAV-SM564UT-E RAV-SM804UT-E RAV-SM1104UT-E RAV-SM1404UT-E. Model name:

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

evo + HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM OWNER S MANUAL Models: GWH09AB-D3DNA2D GWH18AC-D3DNA2D GWH24AC-D3DNA2D

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

LG Room Air Conditioner OWNER'S MANUAL

OPERATING INSTRUCTIONS INDOOR UNIT MSZ-GA50VA MSZ-GA60VA MSZ-GA71VA MSZ-GA80VA

AIR-CONDITIONER SPLIT TYPE

AIR CONDITIONER OWNER S MANUAL. ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH πãõ PORTUGUÊS NEDERLANDS

Portable Evaporative Air Cooler with Heater for indoor use. OWNER S MANUAL Read and save these instructions before use.

The figures in this manual may be different with the material objects, please refer to the material objects for reference.

CARING FOR YOUR WATER HEATER

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

Air Conditioner user manual

AIR CONDITIONER Duct Type OPERATING MANUAL

OWNER S MANUAL SPLIT SYSTEM AIR CONDITIONER. G Series Cooling

SPLIT-TYPE AIR CONDITIONERS

Contact Details. Please note that some of the contact details on this PDF document may not be current.

PORTABLE AIR CONDITIONER (LOCAL)

AIR CONDITIONER OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL

To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Operation Manual MODELS FTX20J2V1B FTX25J2V1B FTX35J2V1B DAIKIN ROOM AIR CONDITIONER. English. Deutsch. Français. Nederlands. Español.

OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO

RMI-1103-A SERVICE MANUAL MIDEA AIRCONDITIONER EUROPE MARKET DC INVERTER MULTI TYPE R DC INVERTER MULTI SERIES

All about the Use &Care

REMOTE CONTROL MANUAL

Dehumidifier Users manual. For Models: DH45S DH65S

Wall Mounted Mini Split Heat Pump Air Conditioner

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

MODELS FVXS25FV1B FVXS50FV1B FVXS35FV1B

Owner s Manual RAV-SM404MUT-E RAV-SM454MUT-E RAV-SM564MUT-E AIR CONDITIONER (SPLIT TYPE) Indoor Unit. Model name: Compact 4-way Type.

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Split Air Conditioner

SPLIT-TYPE AIR CONDITIONERS

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

Transcription:

F566272 Operating Instructions Air Conditioner CS-C18FFH CS-C28FFH CU-C18FFH CU-C28FFH ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference. CONTENTS Safety Precautions... 2 Product Overview... 3 How to Operate... 5 Care & Cleaning... 7 Product Specification... 8

n Definition To prevent personal injury, injury to others and property damage, the following instructions must be followed. Incorrect operation due to failure to follow instructions will cause harm or damage, the seriousness of which is classified as below: Warning This sign warns of death or serious injury. Thank you for purchasing Panasonic Air Conditioner SAFETY PRECAUTIONS Installation Precautions Do not install, remove and reinstall the unit by yourself. Improper installation will cause leakage, electric shock or fire. Please consult an authorized dealer or specialist for the installation work. This equipment must be earthed and installed with ELCB. Otherwise, it may cause electrical shock or fire in case of malfunction. This air conditioner must be earthed. Improper grounding will cause electric shock. Ensure that the drainage piping is connected properly. Otherwise, water will leak. Do not install the unit in a potentially explosive atmosphere. Warning Caution Caution This sign warns of injury or damage to property. The instructions to be followed are classified by the following symbols: This symbol denotes an action that is PROHIBITED. Operation Precautions Do not share power outlet. Do not modify power cord. Do not use an extension cord. Do not operate with wet hands. Do not insert finger or other objects into the indoor or outdoor unit. Do not attempt to repair the unit by yourself. Do not use rechargeable (Ni-Cd) batteries in remote control. Keep the remote control away from infants and small children to prevent them from accidentally swallowing the batteries. Do not touch the fin of the indoor and outdoor unit. Warning Remove the cover of the outdoor unit before operating. Use specified supply cord. If the supply cord is damaged or needed to be replaced, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. Remove the batteries of remote control if the unit is not going to be used for a long period of time. New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control. In case of emergency or abnormal condition (burnt smell, etc) occurs, turn off the power supply. These symbols denote actions that are COMPULSORY. Stand on a firm platform to operate the air conditioner or carry out maintenance. Do not wash the unit with water, benzene, thinner or scouring powder. Do not use for other purposes such as preservation of food. Do not use any combustible equipment at airflow direction. Do not sit or place anything on the indoor or outdoor unit. Do not expose directly to cold air for a long period. Caution Ventilate the room regularly. Pay attention as to whether the installation rack is damaged after long period of usage. Switch off the power supply before cleaning or servicing. Switch off the power supply when the unit is not to be used for an extended period of time. Safety Regulation The appliance is not intended for use by young children or infirm person without supervision. Young children should be supervised to ensure that they do not play with the appliance. Replacement or installation of circuit breaker shall be performed by authorized/qualified personnel only. The wires in this mains lead are coloured in accordance with the following code: Terminals red black green/yellow wires live neutral earth colours (GB Standard) brown blue green-yellow Operation Condition ( C) Use this air conditioner under the following temperature range. DBT: Dry Bulb Temperature WBT: Wet Bulb Temperature Indoor Outdoor DBT WBT DBT WBT Maximum Temperature 32 23 43 26 Minimum Temperature 21 15 21 15 Different countries may have different colour coding for the wires. 2

Note: The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for future improvement. PRODUCT OVERVIEW Indoor Unit Discharge Vent n About OFF/ON operation button To turn off or turn on the air conditioner. Operation mode, temperature, fan speed and OFF/ON timer should be set by remote control. ENGLISH Horizontal airflow vanes Vertical airflow vanes Air filter Intake grille Air intake Discharge air Control and Indicator Panel (Signal receiving) Auto OFF/ON Button To operate the unit if the remote control is misplaced or malfunctioning. Action Press once. Press until beep sound. Operation mode Automatic Operation Cooling Operation To OFF, press again the Auto OFF/ON button. To switch the remote control signal receiving sound off or on. 1. Keep pressing the Auto OFF/ON button for about 10 seconds until beep-beep sound to switch off the signal receiving sounds. 2. Repeat the above step if you want to switch on the signal receiving sounds. AIR SWING Airflow direction only can be adjusted manually. Vertical airflow direction control. Outdoor Unit Air inlet (rear) 1. Pull the vane by the left and right portion gently. 2. Don t use the uppermost and the lowest vane to adjust. 3. Don t let the vanes downward continuously for a long time, otherwise condensation may be caused around the discharge vent. Horizontal airflow direction control. Air inlet (side) Air outlet To adjust horizontal airflow vanes gently by holding the control handle on the top left. Troubleshooting l Operation delayed for few minutes after restart. l Sound like water flowing during operation. l Mist emerges from indoor unit. l Noisy during operations. l Remote control/display does not work. l The unit cannot operate. l Outdoor unit emits water/steam. ä This is a normal self protection control. ä Caused by refrigerant flow inside. ä Condensation effect due to cooling process. ä Installation work could be slanted or intake grille didn t close properly. ä Check whether batteries are correctly inserted or need replacement. ä Check either circuit breaker is tripped, or timer is used correctly. ä Condensation or evaporation happens at piping surface. 3

n About Remote Control Preparation Pull out PRODUCT OVERVIEW Remote Control Reset terminals Insert batteries (AAA or R03) The batteries can be used for approximately 1 year. Remove the batteries if the unit is not to be used for a long period. The batteries must be recycled or disposed of properly. Note: The retention period of batteries might be affected to be shorter because of the using times of the remote control, even less than one year. Remote Control Signal Make sure it is not obstructed. Maximum distances : 8m. Certain fluorescent lights may interfere with signal transmission. Consult your dealer. Reset the remote control If the display is chaotic or can not be adjusted, use a screwdriver to short the two terminals to reset the remote control to the original set by manufacturer. LCD display Operation mode Timer setting Fan speed selection Transmitter Off/On Temperature setting Hints l If you wish to have the cool air blowing directly on you, set the airflow direction downward but not for an excessive length of time, as it may harm your health. l Approximately 10% of electricity can be saved if you set the temperature 1 C higher than the desired temperature during cooling operation. Troubleshooting l Indoor fan stops occasionally during Automatic Fan Speed setting. ä This is an advanced feature that helps to remove smell from the surrounding area during operation. 4

HOW TO OPERATE Auto, Cool, Dry, Fan Fan Speed FAN 2 Select the desired operation. FAN SPEED Select fan speed. 1 Start the operation. 3 Set the temperature. n Operation Details AUTO - Automatic Operation The unit will automatically select the operation mode according to the room temperature. Once the operation mode is selected, the unit will operate at the standard setting temperature as shown: Room temperature Operation mode Standard setting temperature 23 C & above Cool 25 C Below 23 C Dry 22 C The operation mode judging temperature and standard setting temperature can be increased or decrease by 2 C permanently, by pressing temperature button or. COOL - Cooling Operation Enables you to enjoy the cooling effect at your preferred setting temperature. The range of temperature can be selected from 16 C ~ 32 C. DRY - Soft Dry Operation Enables you to set the desired temperature at low fan speed which provides you with the dehumidifying surroundings. The range of temperature can be selected from 16 C ~ 32 C. FAN - Air Circulation operation Enable the room to maintain a good ventilation;purifying and deodorizing the air. The compressor will not operate during air circulation operation. ENGLISH FAN SPEED To provide you with the various fan speed selections. There are 2 levels of fan speed in addition to automatic fan speed. Automatic fan speed: The speed of the indoor fan is automatically adjusted according to the operation. Hint l To save electricity, close the curtains when using air conditioner to prevent sunlight and heat from coming in. Troubleshooting l The room has a peculiar odour. l Air conditioner does not cool efficiently. ä This may be a damp smell emitted by the wall, carpet, furniture or clothing in the room. ä Ensure the temperature has been set correctly. ä Ensure windows and doors have been closed properly. ä Ensure filters are cleaned or replaced when necessary. ä Ensure inlet and outlet vents of the units have not been obstructed. 5

n Operation Details ON TIMER Use the ON timer to turn on the air conditioner at the desired time. This will give you a cooling environment, e.g. when you return from work or wake up. When the ON timer and COOL or DRY operation mode are set, operation will start 15 minutes before the actual set time in order to reach the remote control s set temperature at the set time. The ON timer can be only set while the air conditioner is not in operation. OFF TIMER Use the OFF timer to stop the air conditioner operation at the desired time. This can save electricity while you are going out or sleeping. The OFF timer can be only set while the air conditioner is in operation. HOW TO OPERATE Timer 1 Select ON or OFF timer. 2 Set the desired time. 3 Confirm the setting. CANCEL Cancel the selected timer. l The timer indicator of the indoor unit will light up during the timer operation. l To cancel either the ON or OFF timers, press press operation button during the timer setting operation, timer setting will be cancelled. l When a power failure occurs, the timer setting will be cancelled. Once power is resumed, reset the timer.. If you Hints l For your convenience, you could set the air conditioner to operate automatically by using either ON or OFF timer. Troubleshooting l POWER indicator is blinking 30 minutes before ON timer is activated. ä The unit is determining the operation mode by sensing the room temperature. This happens when it has been set to AUTO operation mode. 6

CARE & CLEANING Switch off the power supply before cleaning n Washing Instructions Do not use benzene, thinner or scouring powder. Use soaps or neutral household detergent ( ph7) only. Do not use water with temperature higher than 40 C. ENGLISH Remove AIR FILTER Vacuum, wash and dry. Screws INTAKE GRILLE Lose the two screws and open the grille,then remove. Wash and dry. INDOOR UNIT Wipe gently. INDOOR UNIT Wipe the unit gently with a soft, dry cloth. AIR FILTER It is recommended to clean the air filters once every 2 weeks. Purchase the replacement filter if it is damaged. Part no.: CWD001217 n Preparation for extended Non-operation To dry the internal parts of the indoor unit, operate the unit for 2-3 hours using FAN operation. Switch off the air conditioner and disconnect the power supply. Remove the remote control batteries. n Pre-season Inspection This inspection is recommended before operating the air conditioner at every season. Check if the remote control batteries needed to be replaced. Ensure there is no obstruction at all air intake and outlet vents. After the start of operation for 15 minutes, it is normal if the temperature differences between air intake and outlet vents at indoor unit is:- Operation Temperature difference Cooling 8 C Hints l Clean the filter regularly as dirty filters will cause unpurified air, low cooling capacity, unpleasant smells and higher energy consumption. l The unit will become dirty and the performance of the unit will decrease after used for several seasons. Please consult an authorized dealer to perform seasonal inspections in addition to regular cleaning. l When thunder and lightning occur, stop the unit and switch off the power to protect the air-conditioner. l If power resumed after a power failure,the operation will be restarted automatically under the previous operation mode. l This air-conditioner may cease because of strong surge of voltage. If that happens, consult to an authorized dealer. 7

PRODUCT SPECIFICATION Indoor Unit Outdoor Unit Model CS-C18FFH CU-C18FFH CS-C28FFH CU-C28FFH COOLING Single, 220V-240V, 50Hz Single, 220V-240V, 50Hz [W] 1900-1950 2600-2650 Power/Current [A] 8.65-8.80 11.90-12.00 Refrigerant [kg] R22* 0.94 R22 1.41 Cooling Capacity [kw] 5.10-5.15 7.20-7.30 Noise Level JIS C 9612 [<70 db(a)] 46-47 48-49 [db(a)] Conditions 1m Distance Max. cooling 53-54 53-54 Air Circulation [m 3 /min.] 14.5-15.5 15.0-16.2 Product Weight [kg] 34 35 40 55 Dimensions (H W D) [mm] 1680 500 298 540 780 289 795 900 320 Ambient Temperature [ C] 18-43 *60 g for air purging is not included. Test conditions 1. Cooling: Indoor Dry Bulb Temp. ( C) 27 Outdoor Dry Bulb Temp. ( C) 35 Wet Bulb Temp. ( C) 19 Wet Bulb Temp. ( C) 24 2. Standard piping length:5 m(includes Indoor Unit piping length). 3. Air filter is attached. 8

NON SERVICEABLE CRITERIAS TURN OFF POWER SUPPLY and CALL Authorized Distributor under the following conditions: Abnormal noise during operation Circuit breaker switches off frequently Water/foreign particles have entered the Remote Control Power cord becomes unnaturally warm Water leak from Indoor unit Switches or buttons are not functioning properly F566272 F0812-3