NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS



Similar documents
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

Room Air Conditioners

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Use and Care Manual. Model CPA12KH AIR CONDITIONER

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

Portable Air Conditioner INSTRUCTION MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Get Me Cool Now Portable Air Conditioner User s Manual

PORTABLE AIR CONDITIONER

Meaco 30L and Meaco 40L dehumidifier instruction manual

Portable Air Conditioner

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Important Safeguards

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

Dehumidifier Users manual. For Models: DH45S DH65S

SILENT10 PORTABLE AIR CONDITIONER USER MANUAL

PORTABLE AIR CONDITIONER (LOCAL)

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER

USER S MANUAL HSC-24A

Portable Air Conditioner

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Portable Evaporative Air Cooler with Heater for indoor use. OWNER S MANUAL Read and save these instructions before use.

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

Air Conditioner. Portable BTU/h 2.9kW INSTRUCTION MANUAL CWAC11 CPIN Important! Please read these instructions carefully.

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

Operating Instructions Air Conditioner

OWNERS MANUAL. PAC 210 U Portable Windowless Air-Conditioner

Instruction manual for Firstline FCS12000CH

Operating Instructions Split System Air Conditioner

Room Air Conditioners

Owner s Manual. SRCOOL12K (120V, 60 Hz) SRXCOOL12K (230V, 50 Hz) Portable Air Conditioning Unit. Introduction 2. Important Safety Instructions 2

Platinum Range PLAC12000HP PORTABLE AIR CONDITIONER WITH HEAT PUMP USER MANUAL HIGH MID COLL HEAT DRY FAN LOW F C TIMER SLEEP SWING

WINDOW ROOM AIR CONDITIONER

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

Split Type Room Air Conditioner. KSWM units

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

SWIMMING POOL HEAT PUMP

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

VACUUM CLEANER INSTRUCTION MANUAL

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

SAFETY PRECAUTIONS Read all of the instructions before using this appliance. When using this appliance, always exercise basic safely precautions,

PORTABLE AIR CONDITIONER CLIMATISEUR PORTATIF ACONDICIONADOR DE AIRE PORTATIL

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

Meaco 10L Basic Small Home Dehumidifier

SAFEGUARDING THE ENVIRONMENT

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Wall Mounted Mini Split Heat Pump Air Conditioner

PORTABLE AIR CONDITIONER

WHYNTER 21 Bottle Dual Temperature Zone Freestanding Wine Cooler

Operating Instructions Air Conditioner

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

FT-100 Fire Training Fog Machine User Manual English

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

OPERATION MANUAL OFFICE PRO 18 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS.

Reverse Cycle Inverter Split System Air Conditioner

DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Climax Air Inc. DC Inverter Portable Air Conditioner Model VS12 12,000 BTU Introducing The World s Most Efficient Portable Air Conditioner

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

INDOOR UNIT/OUTDOOR UNIT

OWNER S MANUAL SPLIT SYSTEM AIR CONDITIONER. G Series Cooling

Split Air Conditioner

Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

2-SLICE COOL TOUCH TOASTER

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

Carpet Shampooer 500w

Taurus Series YORK Window Air Conditioners

Operating Instructions

BUILT-IN WINE & BEVERAGE COOLER WITH DUAL TEMPERATURE ZONES INSTRUCTION MANUAL. Model No.: MCWBC77DZC

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

LG Wireless Remote Controller

3000W Power Inverter

Safety, Operation and Maintenance Manual with Parts List

Wine Cooler with Thermo-Electric Cooling & Heating Technology

CARING FOR YOUR WATER HEATER

Whynter 62 QT DUAL ZONE PORTABLE FRIDGE / FREEZER

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Meaco DD8L desiccant dehumidifier Instruction Manual

Reverse Cycle Inverter Split System Air Conditioner

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

R410A SPLIT SERIES DC INVERTER

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) (ROI) White series

Bottom Loading Water Dispenser

INSTRUCTION MANUAL REFRIGERATOR BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Transcription:

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE IT ON A FLAT, LEVEL SURFACE AT LEAST 14 (36CM) AWAY FROM ANY OTHER OBJECTS (FIG 1 & 4). DO NOT PLACE OBJECTS ON THE UNIT AND DO NOT COVER OR OBSTRUCT THE INLET OR OUTLET GRILLES (FIG. 2). THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING ITS USE BY A PERSON RESPONSIBLE FOR THEIR SAFETY. CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE. FIG. 1 FIG. 3 FIG. 2 ELECTRICAL SAFETY: THIS APPLIANCE IS FOR INDOOR USE ONLY. ALWAYS SWITCH OFF THE UNIT AND UNPLUG IT WHEN NOT IN USE. DO NOT USE THIS UNIT IN EXCESSIVELY HUMID OR WET ENVIRONMENTS (FIG 3) DO NOT PULL OR PLACE STRAIN ON THE POWER CORD WHEN MOVING THE APPLIANCE. IF THE POWER CORD IS DAMAGED, IT MUST BE REPLACED BY AN ELECTRICIAN OR SPECIALIZED TECHNICIAN AUTHORIZED BY THE MANUFACTURER IN ORDER TO PREVENT FIRE. FIG. 4 1

FOR MAXIMUM EFFICENCY: Make sure doors and windows are closed while the portable air conditioner is in use. Also keep curtains and blinds closed during the sunniest parts of the day while it is in operation. Frequently clean the filters. Once the room or area has reached your desired comfort level, be sure to reduce the unit s temperature and ventilation settings. 2

PARTS LIST Front Back 1. Display window 2. Control panel 3. Control buttons 4. Louvers 5. Carrying handle 6. Casters FIG.5 FIG.6 7. Cord wrap 8. Air filter 9. Air inlet 10. Exhaust air outlet 11. Air inlet 12. Water plug/drainage port Accessories 13. Hose adaptor (goes over hose and into the window kit) 14. Exhaust hose 15. Activated carbon filter 16. Extendable window kit 17. Hose for continuous drainage 18. Remote control FIG.7 3

INSTALLATION INSTRUCTIONS Installing the Exhaust Hose FIG.8 1. Open the window and insert the window kit into the open gap. 2. Close the window until the window kit is held securely. You may need to adjust the size of the window kit and secure it with screws. This technique may also be used for sash windows. 3. Fit the exhaust hose into the exhaust air outlet located at the back of the air conditioner. 4. Attach the hose adapter onto the exhaust hose. 5. Attach the hose adapter to the window kit. 4

Positioning the Exhaust Hose Insert the exhaust hose into the back of the unit and tighten it into place. Avoid kinks and bends in the exhaust hose. These can cause expelled moist air to accumulate, resulting in overheating and unexpected shut offs (See Fig 9 & 10). Τhe exhaust hose may be extended from 12 inches (300 mm) to 59 inches (1500 mm), but for maximum cooling efficiency, use the shortest length possible. FIG. 9 FIG. 10 FIG. 11 WARNING: The included exhaust hose is specially designed to fit the specifications of this unit. Do not extend it with your own hose, as this can cause the air conditioner to malfunction. FIG. 12 5

Installing the Activated Carbon Filter 1. Remove the filter frame from the unit. 2. Remove the activated carbon filter from its plastic bag. 3. Insert the activated carbon filter into the back of the unit. 4. Reattach the filter frame onto the unit. FIG.13 6

OPERATING INSTRUCTIONS Control Panel 1. ON/OFF (power) button 2. Timer button 3. Timer indicator light 4. Temperature increase button 5. Compressor indicator light 6. Full water tank indicator light 7. Temperature decrease button 8. Low ventilation indicator light 9. High ventilation indicator light 10. Heating mode indicator light (only for AC-10000H) 11. Fan mode indicator light 12. Cooling mode indicator light 13. Automatic mode indicator light 14. Mode selection button 15. Fan speed (ventilation) button 16. Display window 17. Remote control receiver FIG.14 Turning the Unit On and Off 1. Press the ON/OFF button. The unit will start automatically. If the ambient temperature is: - Higher than 74 F, the unit will operate in cooling mode. - Higher than 68 F but below or equal to 74 F, the unit will operate in fan mode. - Equal to or below 68 F, the unit will operate in heating mode (heating mode is only available on model # AC-10000H). 2. The indicator lights showing any functions will turn on. Please note that the display window will only show ambient room temperatures ranging from 32 F to 122 F. 3. To turn the unit off, press the ON/OFF button again. Setting the Mode/Function 1. Press the MODE button to select the desired mode (cooling, heating, fan or automatic). 2. The selected mode s indicator light will turn on. 7

Setting the Temperature 1. Press the UP or DOWN button to change the set temperature. 2. The display window will then indicate the set temperature. If no temperature is set, the display will show the room s ambient temperature. 3. Please note that the default cooling temperature of this portable air conditioner is 75 o F. Setting the Fan/Ventilation Speed 1. Press the SPEED button to select the desired fan speed (high or low). The appropriate indicator light (high or low) will turn on accordingly. 2. If the unit is in AUTO mode, the fan speed will be automatically set according to the ambient temperature (the appropriate indicator light will turn on). Please note that when the unit is in AUTO mode, the speed setting cannot be changed. Setting the Timer 1. Press the TIMER button to set the desired number of operating hours (from 1 to 12 hours). When the set time has been reached, the machine will automatically turn off. The display window will show the number of hours being set as you press the TIMER button. If the TIMER is not set, the unit will work continuously. 2. By pressing the TIMER button without selecting any other modes or settings, you can set the number of hours to be delayed before the unit turns on. For example, if you press the TIMER to 2, the unit will automatically turn on after 2 hours. Heating Mode (only for model no. AC-10000H) When the air conditioner is in heating mode, ambient warm air is recycled and used to heat your immediate area. The exhaust pipe will still need to be fitted onto the unit in order for the cold air to be removed. When in heating mode, the machine can be set on HIGH or LOW speed. All of the above functions can also be performed with the included remote control. The remote control requires 2 AAA batteries to operate. FIG. 15 8

Regulating the Air Flow Direction To control the air flow direction, adjust the knob on the louvers. FIG. 16 PLEASE NOTE: 1. To prolong the life of the compressor, after turning off the unit, please wait at least 3 minutes before turning it back on. 2. The cooling system will switch off if the ambient temperature is lower than the set temperature (the ventilation will keep working at the set level). If the ambient temperature rises above the selected level, cooling will resume. 9

DRAINING THE UNIT During the cooling process, some water will be extracted from the air and stored within the unit s water reservoir. If the water reservoir is full, both the compressor and motor will stop and the unit will beep (press any button to stop the beeping sound). The full water tank indicator light will also start flashing. To resume cooling, empty the reservoir by following these steps: 1. Turn off the air conditioner and unplug it from the wall socket. To prevent water leakage, avoid moving the unit when full. 2. Place a container (such as a small pan) underneath the drainage port. 3. Remove the water plug from the drainage port and allow the water to drain out. 4. When the container is almost full, replace the water plug back into the drainage port and empty the water container. 5. Repeat until the water reservoir is completely empty. 6. Replace the water plug back into the drainage port and make sure it is firmly in place. 7. Turn the unit back on. The warning signal should be off. Drainage port Water plug Cap for the water plug FIG.17 For Continuous Drainage Remove the water plug from the drainage port and retain it for future use. FIG.18 Connect the drainage hose included with unit to the drainage port as shown. Connect the other end of the hose into a drain. Water plug Cap for the water plug 10

The drainage hose may be extended by adding an extension hose using a suitable connector. FIG.19 PLEASE NOTE: 1. The drain must be at or below the level of the drainage port. 2. The full water tank indicator light will not work when the unit is being continuously drained. 3. To extend the drainage hose, you can connect it with another hose with an overall diameter of 0.7 (18 mm). 4. If room humidity levels are over 85%, it will be necessary to continuously drain the unit using the drainage hose. Drainage hose included with the unit FIG.20 Drainage hose included with the unit Extension hose (OD: 0.7 ) For Heating Mode (only for model no. AC-10000H) While using the heating function, please note the following: 1. In order to properly exhaust cool air, make sure the exhaust hose and window kit are properly installed (refer to page 4 for instructions). 2. Set up the air conditioner for continuous drainage using the drain tube (refer to page 10 & 11 for instructions). The working range for the heating function is 32 F to 68 F. The unit may not provide optimal heating if used in temperatures outside this range 11

MAINTENANCE INSTRUCTIONS Always unplug the air conditioner from the power supply before cleaning. To maximize the efficiency of the air conditioner, regularly clean the unit. Cleaning the Housing Use a soft, damp cloth to wipe the body clean. Never use strong chemicals, gasoline, detergents, chemically-treated cloths, or any other cleaning solutions to clean the air conditioner, as these can all potentially damage the unit s housing. Cleaning the Filters: Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters and then rinse them thoroughly under running water (no warmer than 104 o F). Thoroughly dry the filters before replacing them back into the unit. PLEAE NOTE: Never operate the unit without the filters. End of Season Storage Completely drain any condensed water from the unit. Set the air conditioner on fan mode (ventilation only) for a few hours to thoroughly dry the inside of the unit. Clean or change the filter. Unplug and wrap the power cord around the cord wrap as shown (fig. 21). Place the unit back in its original carton and store it in a clean, dry area. FIG.21 12

TROUBLESHOOTING The air conditioner does not function. Is the air conditioner plugged in? Is the power outlet functioning correctly? Is the full water tank indicator light flashing? Is the ambient room temperature lower than the set temperature? The unit does not produce adequate cooling. Is the unit placed in direct sunlight? If so, close any curtains or move the unit to a more shaded area. Are too many windows or doors open? Are there too many people in the room? Are there additional heat sources in the room? Is the filter dusty or dirty? Is the air inlet or air outlet blocked? Is the ambient room temperature lower than the set temperature? The unit is noisy. Is the machine positioned unevenly? Is the unit positioned on an even, solid surface? The compressor does not work. Is the compressor s overheat protection function activated? If so, wait for the temperature to drop and then turn on the unit again. Never try to repair and dismantle the unit yourself. Unauthorized repairs can void your warranty and endanger the user. 13

TECHNICAL SPECIFICATIONS Model Number: AC-10000E AC-10000H Voltage / Frequency 115V / 60Hz Power Consumption for cooling 909W / 8.3A Power Consumption for heating NIL 830W / 7.6A Air Volume (Maximum Speed) 300 m 3 /h Dehumidification Capacity Compressor Type Refrigerant Type 2.1 pints/hr (1 L/hr) Rotary R-410A Number of Fan Speeds 2 Timer Exhaust Pipe Dimensions Product Weight 1 ~ 12 hours Ø4.72 X 59.06 (Ø120x1500 mm) 50.7 lbs (23kg) Product Dimensions (W x D x H) 12.2 x 13.8 x 28 ( 310 x 350 x 710 mm ) ADDITIONAL REMARKS: 1. The data marked with '*' may vary for technical reasons; for more accurate data, please refer to the rating label found on the back of the unit. 2. Measuring condition for the above specifications: Cooling DB = 95 F (35 C), WB= 82.94 F (28.3 C) Heating DB= 68 F (20 C), WB= 59 F (15 C) * D.B. = dry bulb temperature = room temperature * W.B. = wet bulb temperature = relative humidity 14

LIMITED MANUFACTURER S WARRANTY This appliance is covered by a limited manufacturer s warranty. For one year from the original date of purchase, the manufacturer will repair or replace any parts of this appliance that prove to be defective in materials and workmanship, provided the appliance has been used under normal operating conditions as intended by the manufacturer. Warranty Terms: During the first year, any components of this appliance found to be defective due to materials or workmanship will be repaired or replaced, at the manufacturer s discretion, at no charge to the original purchaser. The purchaser will be responsible for any removal or transportation costs. Warranty Exclusions: The warranty will not apply if damage is caused by any of the following: Power failure Damage in transit or when moving the appliance Improper power supply such as low voltage, defective household wiring or inadequate fuses Accident, alteration, misuse or abuse of the appliance such as using non-approved accessories, inadequate air circulation in the room or abnormal operating conditions (extreme temperatures) Use in commercial or industrial applications Fire, water damage, theft, war, riot, hostility or acts of God such as hurricanes, floods, etc. Use of force or damage caused by external influences Partially or completely dismantled appliances Obtaining Service: When making a warranty claim, please have the original bill of purchase with purchase date available. Once confirmed that your appliance is eligible for warranty service, all repairs will be performed by a NewAir authorized repair facility. The purchaser will be responsible for any removal or transportation costs. Replacement parts and/or units will be new, re-manufactured or refurbished and is subject to the manufacturer s discretion. For technical support and warranty service, please call 1-855-9Newair or email support@newair.com.