High Moisture Corn Drying and Storage. Kenneth Hellevang, Ph.D., P.E. Extension Engineer & Professor

Similar documents
Energy Efficient Grain Drying. Kenneth Hellevang, Ph.D., P.E. Professor & Extension Engineer

Grain Drying & Management Bob Schultheis Natural Resource Engineering Specialist University of Missouri Extension

Grain Drying Concepts and Options

UNIVERSITY OF ARKANSAS DIVISION OF AGRICULTURE RESEARCH AND EXTENSION COOPERATIVE EXTENSION SERVICE ON-FARM SOYBEAN DRYING AND STORAGE

Harvesting, Drying, and Storing Malting Barley

On-Farm Drying and Storage of Soybeans

Managing Stored Grain

Walnut Drying Design and Operation. Selecting Dryer Type. Tray Drying Before Don Osias Jim Thompson

Natural Air Drying Corn Paul E. Sumner University of Georgia Biological and Agricultural Engineering Department

Climatography of the United States No

Climatography of the United States No

Corn Harvesting, Handling, Drying, and Storage

Principles of Rice Drying How does rice dry?

Climatography of the United States No

PREVENT FROZEN PIPES

Analysis One Code Desc. Transaction Amount. Fiscal Period

Sea Water Heat Pump Project

Sino-Italian Environment & Energy Building S I E E B

Life Cycle Cost Analysis of Tankless Water Heaters

Greenhouse Cooling. Why is Cooling Needed?

AT&T Global Network Client for Windows Product Support Matrix January 29, 2015

CONDENSATION. Section Break (Next Page)

Soybean Production in Kentucky

Moisture Content in Insulated Basement Walls

Purpose: To determine the dew and point and relative humidity in the classroom, and find the current relative humidity outside.

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

How do I measure the amount of water vapor in the air?

5 Answers and Solutions to Text Problems

Molds and mildew are fungi that grow

Enhanced Vessel Traffic Management System Booking Slots Available and Vessels Booked per Day From 12-JAN-2016 To 30-JUN-2017

Preventing Mold by Keeping New Construction Dry

Creating the Ideal Environment for Accelerated Drying Times on Construction and Restoration Projects

GEOTHERMAL HEAT PUMPS - TRENDS AND COMPARISONS - John W. Lund Geo-Heat Center

The main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.

Design Considerations for Underfloor Heating Systems. What is Frost Heave Protection?

Subtropical Cities September Design for Energy Efficiency in Commercial Buildings in Queensland

Green Data Center: Energy Reduction Strategies

Section 5 CLIMATE TABLES

HVAC. Kitchen Exhaust. rooftop equipment! let s drop on a few exhaust fans! it doesn t get easier!

Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

Grain Stocks Estimates: Can Anything Explain the Market Surprises of Recent Years? Scott H. Irwin

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

Low Cost. Lower Energy Costs. Higher Efficiency.

Design of Closed-loop Fumigation Systems for Grain Storage Structures

Energy Efficiency. Energy Efficient Home Cooling:

Pool Dehumidification Basics

HVAC Design Industrial Ventilation

Liabilities of Vented Crawl Spaces, Their Impacts on Indoor Air Quality in Southeastern U.S. Homes and One Intervention Strategy

The Climate of Oregon Climate Zone 2 Willamette Valley

Kiln Drying Basics for the Small Producer

Case Studies: Infrared Heating in Industrial Applications

Case 2:08-cv ABC-E Document 1-4 Filed 04/15/2008 Page 1 of 138. Exhibit 8

William A. Lotz, PE, Direct Fired Heaters Can. Result in Excessive Moisture and Condensation. By William A. Lotz, PE Consulting Engineer Acton, ME

Economic Evaluation of Residential Air Conditioner Designs for Hot and Dry Climates

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Climate Change. Lauma M. Jurkevics - DWR, Southern Region Senior Environmental Scientist

New Era Marketing 2015

HARVESTING, DRYING AND STORAGE SOYBEANS Paul E. Sumner, Extension Engineer

CONDENSATION IN REFRIDGERATED BUILDINGS

Onion & Leek Planting Guide

Fuel and Energy Conversion and Equivalence Chart

Measuring The Right Thing For Humidity Control It s the Dew Point Stupid!

Unit 4: Electricity (Part 2)

CHAPTER 9: WATER HEATING

Draft - Fumigation Management Plan

HVAC Simplified Approach Option

Infrared Moisture Detection

Home inspectors are not mold inspectors, however they do inspect for defects that

ENGINEERING WEATHER DATA

WATER DAMAGE INVESTIGATION. Massachusetts Department of Public Utilities 1 South Station Boston, Massachusetts

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Building and Grounds Maintenance Checklist

Temperature and Humidity

Innovent LASER Packaged Fresh Air Conditioning Units

Fan and Pad Greenhouse Evaporative Cooling Systems 1

Controlling moisture. For your home. Bellevue, WA Puget Sound Energy. pse.com/myrebates. P.O. Box /14

CONDENSING TANKLESS WATER HEATERS

DRYER VENTING SPECIFICATIONS DRYER SAFETY

TOPIC: CLOUD CLASSIFICATION

How a Ground Source Heat Pump Works for Commercial Buildings

The Water Cycle Now You See It, Now You Don t

The Watergy greenhouse: Improved productivity and water use efficiency using a closed greenhouse

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Direct Fresh Air Free Cooling of Data Centres

Harvesting Dry Bean John Nowatzki, NDSU Extension Agricultural Machine Systems Specialist

Improving comfort and energy efficiency in a nursery school design process S. Ferrari, G. Masera, D. Dell Oro

Environmental Data Center Management and Monitoring

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Preventing Ice Dams on Roofs

Transcription:

High Moisture Corn Drying and Storage Kenneth Hellevang, Ph.D., P.E. Extension Engineer & Professor

Estimated Corn Field Drying EMC GDD PET Est. Drying (%pt) (%) (in) Month Week Sep 15 250-350 4.0-5.0 18 4.5 Oct 16 100-125 2.8-3.5 11-12 2.5 Nov 19 20-30 0.8-1.2 4-5 1 Dec 20 0 0.5-0.8 2 0.5 Jan 21 0 0.5-0.8 2 0.5 Feb 21 0 0.5-0.9 3 0.8 Mar 19 0 1.3-1.6 5 1 Apr 16 50-90 3.2-4.5 16 4 May 14 200-300 6.5-8.5 30 7 NDAWN, Weather, Total PET, Estimate:1-inch = 4% drying EMC-equilibrium moisture content, GDD-growing degree days PET=Potential Evapotranspiration

Corn Harvest Usual Harvesting Dates North Dakota: 20-Year Average Begin Most Active End Corn for grain September 28 October 8-November 19 December 6 Average % Percent Harvested (2006-10) October November 2 9 16 23 30 6 13 20 3 8 18 31 44 56 64 71

Moisture Meter Error Calibrated for 15% corn error on high moistures Adjust for temperature Not accurate <40 F Electronic meters more sensitive to outside of kernel Moisture variation after rapid drying Meters affected by condensation Measure moisture content Place sample in sealed container for several hours (6-12 hrs) Warm to 70 F Recheck moisture

25% - 30% Moisture Corn Pile so can mechanically load 28% corn @ 40 F, AST = 30 days Aerate to keep corn temperature <30 F High Temperature Dry by early February

Holding 22% - 24% Corn Cool to 20 F High temperature dry by early March Deterioration in early spring (AST)

Corn Flowability 28% moisture freezes together 24% - 25% some binding <24% to assure flow Foreign material affects flow Danger!

Grain Temperature Average Maximum Air Temp. February 1-15 March 1-27 April 1-45 May 1-65 Solar Radiation (Btu/ft 2 -day) Wall Roof Feb. 21 1725 1800 Jun. 21 800 2425 Periodically Cool Keep under 30 F

Let Stand Over Winter Spring (March) moisture content 19-21% Field losses unknown Check Stalks Snow accumulation 40 = 4 water

Uncovered Piles 1-inch rain increases moisture content of 1 ft of corn by 9 percentage points 6-10 inches of snow = 1-inch water Keep Surface Smooth to aid run-off? 43% voids - Will water run off before a crust forms?

Grain Piles Prepared surface Negative pressure holds cover Examine for Perforations Designed and managed aeration is critical for piles.

Poly Bag Storage Sealed bag does not prevent mold growth or insect infestation. Grain temperature follows average outdoor temperature.

Fuel Cost Cost per bu. $1.85 gal. Propane, $.10/kWh 5% Pt. Removal Pressure Heat Pressure Cool 16.0 Full Heat 13.1 Pressure Heat Vacuum Cool 12.5 Pressure Heat Vacuum Cool Heat Reclaim 9.0

Energy requirements of a conventional cross-flow dryer as a function of drying air temperature and airflow rate. NDSU AE-701 (University of Nebraska) Energy required to remove a pound of water is reduced at higher plenum temperatures and lower airflow rates. Use the maximum temperature that will not damage the grain.

Drying Energy Cost Estimation High Temperature Drying~210 F Assumes 2,500 Btu/lb water Propane cost / bu- point moisture = 0.022 x price/gal $ 0.044/bu-pt = 0.022 x $2.00/gal $ 0.033/bu-pt = 0.022 x $1.50/gal $ 0.022/bu-pt = 0.022 x $1.00/gal @ $1.00/gal propane, estimated propane cost to dry corn from 22% to 16% is $0.022/bu-pt x 6 pts = $0.13/bu. At 2,000 Btu/lb = 0.0177 x Propane Price

Heat of Vaporization Drying Cereal Grains Brooker, Bakker-Arkema, Hall

Estimate Propane Quantity Needed Propane gallons = 0.02 x bu. x point moisture Propane = 0.02 x 1,000 bu x 10 pts = 200 gallons Based on 2,500 Btu/lb. For 2,000 use 0.016/bu. pt.

Test Weight Increase When Drying Adjustment added to the corn wet-harvest test weight to obtain an expected test weight after drying to 15.5 percent moisture. Harvest Mechanical Damage (Percent) Test Weight Adjustment (lb/bu.) 45 0.3 40 0.7 0.2 35 1.3 0.7 Harvest Moisture Content (Percent) 30 28 26 24 22 20 18 16 Affected by: * Kernel Damage * Drying Temperature * Variety Normally ¼ to 1/3 lb/pt. 30 1.8 1.3 0.8 25 2.4 1.9 1.4 0.9 0.3 20 3.1 2.6 2.0 1.5 1.0 0.5 15 3.8 3.2 2.8 2.2 1.7 1.2 0.6 0.2 10 4.5 1.0 3.5 2.9 2.2 1.9 1.4 0.8 5 5.3 4.7 2.2 3.7 3.0 2.7 2.1 1.6 0 6.1 5.6 5.0 4.5 4.0 3.5 2.9 2.4

High Temp. Dryer Management High temperatures, fast drying, fast cooling creates stress cracks, broken kernels & lower final test weight High moisture increases scorching potential, Reduce plenum temperature

Dryer Heat Damage Yes No Sugar discolors during drying Variety & starch dependent Lower dryer temperature and time

Moisture Shrink (Weight loss due to moisture loss) Moisture Shrink (%) = Mo Mf x 100 100 Mf Example: Corn dried from 25% to 15% moisture Shrink%= 25% 15% x 100 = 11.76% 100% 15% Shrink Factors (% weight loss/percentage point moisture loss) 15.5% 1.1834 13.5% 1.1561 13.0% 1.1494 10.0% 1.1111 Example: The moisture shrink drying corn from 25.5% to 15.5% is 10pts x 1.1834 = 11.8%

Dryeration Dump hot, temper without airflow 4-6 hrs, cool Extensive condensation - must move corn to another bin Moisture reduction: 0.25%/10 F cooled, 2.5% Increases dryer capacity 50%-70%, Reduces energy by about 15%-30% Dryeration reduces energy consumption by about 25%, but it is imperative to move the corn to another bin for storage to prevent storage problems.

In-Storage Cooling Immediately cool, Airflow rate 12 cfm/bu-hr of fill rate About 1-1.5 percentage point moisture reduction (0.1 0.15 / 10ºF) Reduce condensation if outdoor temperature is below 50ºF by partial cooling in the dryer typically to about 90 F In-storage cooling requires rapid cooling and cooler initial grain temperature to limit condensation. Slow cooling saves more energy, but storage problems typically occur near the bin wall.

Storability Cracked, broken, immature corn spoils easier Test weight is an indicator of storability Variety variation

Approximate Allowable Storage Time for Cereal Grains (Days) Moisture ----- Grain Temperature ( F) ----- Content 30º 40º 50º 60º 70º 80º (%) Approximate Allowable Storage Time (Days) 14 * * * * 200 140 15 * * * 240 125 70 16 * * 230 120 70 40 17 * 280 130 75 45 20 18 * 200 90 50 30 15 19 * 140 70 35 20 10 20 * 90 50 25 14 7 22 190 60 30 15 8 3 24 130 40 15 10 6 2 26 90 35 12 8 5 2 28 70 30 10 7 4 2 30 60 25 5 5 3 1 * Exceeds 300 days

Condensation may freeze over vents when outside air temperatures are near or below freezing Leave fill and access open Iced over vents will damage bin

Moldy Grain Health Hazard At least a N-95 rating

Grain Hazards Bridging transfers load to the bin wall CAUGHT IN THE GRAIN! AE-1102 Ice on blade may cause it to disintegrate

Natural Air and Low Temperature Corn Drying 21% Initial Corn Moisture Content, Average ND Climatic Conditions Drying Time (Days) Month & added heat Temp. ( F) RH EMC 1.0 cfm/bu 1.25 cfm/bu Oct. +3 F (fan) 50 58% 13.5% 42 34 Oct. 15 Nov +3 F (fan) 37 66% 15.8% 65 52 Nov. +3 F (fan) 30 64% 16.0% 70 56 Nov. +3 F (fan)+2 F 32 58% 14.6% 65 52 Nov. +10 F 37 48% 12.5% 51 41 Using a humidity controlled heater reduces the potential for over-drying the corn

Minimum Recommended Airflow Rate For Natural Air Drying Corn Airflow Moisture Rate Content (cfm/bu) (%) 1.00 21 1.25 22 1.5 23 2.0 24 2.3 25 Wilcke and Morey, University of Minnesota Bu-6577-E, 1995

Fan Power Required Energy efficiency maximum depth about 22 ft. and airflow rate about 1.0 cfm/bu. Airflow Rate Corn Depth (ft) 16 18 20 22 24 (cfm/bu) ----- hp per 1,000 bu ----- 1.0 0.6 0.8 1.1 1.3 1.7 1.25 1.1 1.4 1.8 2.3 2.9 1.5 1.7 2.2 2.9 3.6 4.5 Horsepower calculated based on a 42 ft diameter bin 42 ft diameter bin, corn 36 ft deep, 1.0 cfm/bu Fan = 180 hp, static pressure = 17-inches wg.

Air Drying 21% Maximum moisture content 1.0 cfm/bu minimum airflow rate Start when fall temperatures average <50 F Cool to 20-30 F for winter storage Start drying when temperature average >40 F

For More Information Internet Search: NDSU Grain Drying & Storage