Information Note Connecting a BRI - checklist



Similar documents
For T1 / E1, an NT NeTwork device must be connected to a TE Terminal Equipment device; NT must connect to TE.

Initial configuration Vega 400 E1/T1 (H.323) Gatekeeper Mode R7

Mediatrix 4404 Step by Step Configuration Guide June 22, 2011

TFM GSMRoute BRI. Quick Installation Guide

In the following installation procedures, do not disconnect the Mediatrix 3000 Series while the LEDs are flashing.

VegaStream Information Note T.38 protocol interactions

NEC 2400 IMS --- T1 PRI

ISDN Troubleshooting October 11, 2012

TECH ARTICLE Date: 03/04/08

Initial configuration Vega 400 E1/T1 (SIP)

Quick Installation Guide

P-2602HWNLI. Quick Start Guide g Wireless ADSL2+ 4-port VoIP IAD. Version /2007 Edition 2

P-2602HWNLI. Quick Start Guide g Wireless ADSL2+ 4-port VoIP IAD. Version /2006 Edition 1

Configuring the ADTRAN ATLAS for a Rabbit-Hole Application

SIP Trunking using Optimum Business SIP Trunk Adaptor and the Allworx 6x IP PBX

ISDN Commands. interface bri number

AudioCodes Mediant 1000 Configuration Guide

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Allo PRI Gateway and Elastix Server

VegaStream PSTN Gateways and pbxnsip

ISDN Diagnostic Codes

If you are unable to set up your Linksys Router by using one of the above options, use the steps below to manually configure your router.

OfficeMaster SBA (Survivable Branch Appliance)

Atlas Event Logging Explanation

Telephone User Guide

DPH-50U VoIP USB Phone Adapter Quick User Guide

SIP Trunking using Optimum Business SIP Trunk Adaptor and ShoreTel IP PBX Phone System

T3 Mux M13 Multiplexer

How To Set Up A Netvanta For A Pc Or Ipad (Netvanta) With A Network Card (Netvina) With An Ipa (Net Vanta) And A Ppl (Netvi) (Netva)

LifeSize Networker Installation Guide

Ethernet Radio Configuration Guide

Vertex VoIP Caller ID (Version 1.5)

Prestige 660R-6x Read Me First

Mediatrix Gateway 440x Series Quick Configuration Guide

UCM61xx Configuration

Remote Office 911x Series Installation and Administration Guide

Wave 500 IP PBX v4.5. SIP Trunking using the Optimum Business Sip Trunk Adaptor and the Wave 500 IP PBX v4.5

DVG-2101SP VoIP Telephone Adapter

Broadband Phone Gateway BPG510 Technical Users Guide

Model PBX 206 System User Guide

Cisco T1 Layer 1 Troubleshooting

Configuration Notes 0217

SV9100 SIP Trunking Service Configuration Guide for Time Warner Cable Business Class

Vega 100G and Vega 200G Gamma Config Guide

RAM: 2 Gb Hard Drive: 168 hours of recording per Gb of disk space available NIC : 2 NIC cards required for IP Recording.

Feature Description: Situation: Feature: Redirecting Number Information Element (RNIE)

Grandstream Networks, Inc. How to Configure T1 Trunk on UCM6510

MyPBX U510 Installation Guide

2 Setting Up the Hardware for a Wired Ethernet Network Setting Up the Software for an Ethernet Network... 21

Connecting Sipura ATAs to a legacy PBX System.

Configuration Notes 283

Getting Started. 16-Channel VoIP Gateway Card. Model No. KX-TDA0490

Installation Guide (No Router)

SIP Trunking Service Configuration Guide for Time Warner Cable Business Class

MAX T1/E1. Quick Start Guide. VoIP Gateway. Version 1.0

Thank you for purchasing a Panasonic Pure IP-PBX. Please read this manual carefully before using this product and save this manual for future use.

beronet Technical Training

MST - What Is It? Uses. Useful for isolating problems to the PBX or external equipment Provides a detailed view of what happened when

Special Note Ethernet Connection Problems and Handling Methods (CS203 / CS468 / CS469)

Information Note Syslog

Personal USB VoIP Gateway User s Guide

SIP Trunking Service Configuration Guide for Skype

SIP Trunking using the Optimum Business SIP Trunk Adaptor and the FortiVoice IP-PBX

VegaStream Information Note Considerations for a VoIP installation

Getting Started KX-TDA5480

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

Digital Phone Installation & User Guide

Cost Effective Tapping and Call Recording using the Sangoma T116 Card. November 2013

NetVanta 3000 Series (with T1/FT1 or T1/FT1 with DSX-1 Network Interface Module)

How To. Configure E1 links. Introduction. What information will you find in this document?

VegaStream Information Note QOS Statistics

Avaya IP Office 8.1 Configuration Guide

Troubleshooting the Cisco Unified Videoconferencing 3500 Gateway

CHECKLIST FOR CDR INTEGRATIONS

Getting Started. 16-Channel VoIP Gateway Card. Model No. KX-TDA0490

Assign a static IP address for your computer. Please refer to the T3 in Troubleshooting guide if you need assistance.

MyPBX U100 & U200 Installation Guide

Integrated Voice. Service Guide. Save money and maximize bandwidth efficiency Version

Application Note - IP Trunking

Integrated Voice. Service Guide. Learn More: Call us at Save money and maximize bandwidth efficiency

Release Notes for NeoGate TE X

-Helping to make your life betterwww.person-to-person.net

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

High-Level Data Link Control

Optimum Business SIP Trunk Set-up Guide

Setting Up the ZigBee Ethernet Gateway

OmniAccess 5320 BG. Business Gateway. User s Guide

2100 Series VoIP Phone

Thank you for purchasing a Panasonic Pure IP-PBX. Please read this manual carefully before using this product and save this manual for future use.

PC Program User s Guide ( ) 1. Connecting the PC. 2. Installation and Start-up. 3. Programming

1ISDN. August Software Reference ISDN 1

PSC Defective Customer Equipment Return Policy

aurora Plus Basic Rate ISDN Tester

Whitepaper: Voice Call Notifications via VoIP and existing Dialogic Diva Boards

SIP Trunking using the Optimum Business SIP Trunk adaptor and the AltiGen Max1000 IP PBX version 6.7

PBX-64 Analog and IP Phone System Installation

2N - ISDN BRI GSM Enterprise Gateway

Mediatrix Gateways and ISDN Clock Synchronization June 22, 2011

Transcription:

Information Note Connecting a BRI - checklist When connecting a Vega to a BRI device there are a number of steps that need to be followed in order to ensure that the link will come up and the system will operate correctly. Trunk interface (DSL) configuration In ISDN, an NeTwork device must be connected to a Terminal Equipment device; must connect to. For example the PSTN/ISDN will be NeTwork and the trunk interfaces of a PBX will be Terminal Equipment. PSTN / ISDN pbx For a Vega to operate correctly, it must have its trunks configured / appropriately; if it is to connect to a device and if it is to connect to an device. By default Vega gateways are configured with alternate trunks configured and, IF:01 =, IF:02 =, etc. so often it is possible to use default Vega configuration. (If you need to change the configuration, see the appropriate step-by-step initial configuration guide) Version 0.3 5 July 2006 Page 1 of 8

Hardware connectivity Use the diagrams in Annex 1 to correctly wire in your Vega 50 BRI. Note Vega 50 BRI uses different cables depending on whether a trunk is being connected to an or a device. N.B. Do Not use Vega 100 or Vega 400 cables the pinout is completely different to BRI cables. The channel LEDs on the Vega 50 BRI indicate the connectivity status of the line. If the LED is off there is either no cable connection, or the cable is wrongly wired. If the LED is flashing, layer 1 (the physical layer) has connected OK, but signalling layer 2 has not connected properly. If the LED is solidly on then the signalling layer 3 has connected correctly. Note: BRI devices often take layer 2 down between calls. It is therefore acceptable for the relevant channel LED to be flashing when there is not a call in progress on that trunk. Termination of BRI lines and number of devices on the line Electrically, BRI lines should be terminated using terminating resistors at both ends of the BRI (S0) bus. If BRI lines are not properly terminated, reflections of signals on the lines can make the signalling and media connection unreliable Vega 6x4 BRI gateways have terminating resistors built in, so external terminating resistors are not required. On Point-to-Multi-Point busses where there are multiple BRI devices attached, ensure the bus is terminated at the ends only and that none of the mid-point BRI devices have termination resistors enabled (i.e. put the Vega at the end of the bus). Do not exceed the maximum of 8 devices on the line (S0 bus). Point-to-Point, Point-to-Multi-Point and I BRI lines can be configured in Point-to-Point mode or Point-to-Multi-Point mode. Point-to-Point mode is used where it is known that only a single device will be connected to the line. Point-to- Multi-Point is used where, for example, multiple telephones or ISDN / data adaptors may be connected to the line. Generally a line supplied to connect to a PBX will be Point-to-Point (but this is not always the case), and a line supplied to connect to ISDN handsets will be Point-to-Multi-Point. When connecting the Vega, it must be configured the same as the device(s) that it is connecting to. If the other device is in Point-to-Point mode, the Vega must be set to Point-to-Point mode, and if the other device(s) is configured in Point-to-Multi-Point mode, the Vega must also be configured as Point-to-Multi-Point. In Point-to-Multi-Point mode the Vega and the other devices will automatically negotiate their I (Terminal Endpoint Identifier) values leave the Vega configured for I=64. In Point-to-Point mode, the I value of the Vega must be statically configured. Configure the Vega to have the same I value as the far end device (in the range 0 to 63). Version 0.3 5 July 2006 Page 2 of 8

If you do not know the I value of the far end, a good starting point is to try a I of 0, otherwise take an ISDN trace and look at the I value in the messages sent by the other device. [NEC XenMaster BRI trunks are point-to-multipoint they cannot be configured for poit-to-point operation even though they usually connect directly to the ISDN] Layer 2 restart In order to allow layer 2 to be taken down between calls: set _advanced.isdn.restart_l2_after_disc=0 If this is not set, then event logs (and SNMP) will report the ISDN trunk regularly going down and being brought back up again. As a rule of thumb, Point-to-Multi-Point trunks can be expected to take layer 2 down between calls, and Point-to-Point trunks typically keep layer 2 up, but this is only a guide. Bus master In order to keep synchronised the Vega should synchronise itself with a master clock typically the PSTN clock. Generally trunks receive the clock and trunks are clock masters. If a Vega trunk is not synchronised, then there will be SLIPs to check for SLIPs, use show ports. One or 2 slips often occur at start up this is acceptable; if the slip count keeps increasing, there is a problem that needs to be resolved. See Information Note IN03 ISDN clocks for details about how to configure clocking and Bus Master. Further configuration To configure your Vega for use, see the appropriate step-by-step initial configuration guide and / or the step-by-step guide insert Vega between PSTN and PBX Trouble-shooting No physical connection (LED off) - check that is connected to and is connected to - check whether a crossover is needed - check exact cabling pinouts Rx+ connects to TX+ Rx- connects to TX- Tx+ connects to Rx+ Tx- connects to Rx- - if still problems take an ISDN trace (see Annex 2) especially look for SABMEs No layer 2 (LED flashing) - N.B. this is acceptable for BRI when no calls are in progress on a trunk - If calls are not handled correctly, consider pmp / pp - take an ISDN trace (see Annex 2) especially look for SABMEs Layer 2 up (LED flashing / on), call disconnects with error code 38 - check that the call is being routed to a trunk that is up Version 0.3 5 July 2006 Page 3 of 8

Layer 2 up (LED on), outgoing call to ISDN is rejected by the network - check that the caller ID being presented in the outgoing ISDN call is a valid caller ID for that trunk. Some network operators check the caller ID on outgoing calls and reject calls if an invalid caller ID is being presented (other network operators just over-stamp caller ID with the Trunk caller ID). Layer 2 up (LED flashing / on), some calls work, others don t If the link is Point-to-Point and the Vega is set at its default Point-to-Multi-Point then the Vega will accept calls, but outbound calls will fail. - take an ISDN trace (see Annex 2) especially look for differences in the SETUP (and other) messages between working and non-working calls. - for instance Channel ID preferred / exclusive choice sometimes matters (see _advanced.isdn.chanid_excl) Type of Number, Numbering Plan, and screening information can be important generally these should be configured as supplied so that they are passed through from inbound call to outbound call. They can be overriden on a per trunk basis (advanced > setup_mapping > called party number / calling party number) or on a per call basis (planner.post_profile) Bearer capability generally this should be passed through but it can be overriden on a per trunk basis (advanced > setup_mapping > bearer capability). Version 0.3 5 July 2006 Page 4 of 8

Annex 1 Physical connectivity of a Vega 50 BRI PSTN () 3 Rx+ 6 Rx- 4 Tx+ 5 Tx- Wall connector PBX () Cable pinouts Cables with RJ48 plugs are used to connect to the Vega 50 BRI's ISDN ports. The pinout of each Vega 50 BRI interface is hardwired as. A (BLUE) straight through cable is used to connect a Vega DSL to an far end device. A (RED) cross-over cable is used to connect an Vega DSL to a far end device. Vega 50 BRI Far end device (physical) 3 (Tx+) 3 (Rx+) 4 (Rx+) 6 (Tx-) 6 (Rx-) 5 (Rx-) 4 (Rx+) 4 (Tx+) 3 (Tx+) 5 (Rx-) 5 (Tx-) 6 (Tx-) For Loopback between a Vega port and a Vega port, use the RED cable Version 0.3 5 July 2006 Page 5 of 8

Physical connectivity of a Vega 50 6x4 BRI PSTN () 3 Rx+ 6 Rx- 4 Tx+ 5 Tx- 3 Rx+ 6 Rx- 4 Tx+ 5 Tx- Wall connector PBX () Cable pinouts Cables with RJ48 plugs are used to connect to the Vega 50 6x4 BRI's ISDN ports. The pinout of each Vega 50 6x4 BRI interface automatically changes from to depending on the configuration setting in the Vega. A (BLUE) straight through cable is used to connect an Vega DSL to a far end device, and the same (BLUE) straight through cable is used to connect a Vega DSL to an far end device. Vega 50 BRI Far end device 3 (Tx+) 3 (Rx+) 6 (Tx-) 6 (Rx-) 4 (Rx+) 4 (Tx+) 5 (Rx-) 5 (Tx-) VegaStream provided cables (ISO 8877) Version 0.3 5 July 2006 Page 6 of 8

Vega 50 BRI Far end device 3 (Rx+) 3 (Tx+) 6 (Rx-) 6 (Tx-) 4 (Tx+) 4 (Rx+) 5 (Tx-) 5 (Rx-) VegaStream provided cables (ISO 8877) For Loopback between a Vega port and a Vega port, use the BLUE cable Version 0.3 5 July 2006 Page 7 of 8

Annex 2 ISDN trace Follow the guidelines in the Information Note IN 04 - Low level ISDN trace to take the trace. If there are link start up problems, look for SABMEs Both and devices should send SABMEs, though typically devices will send the SABME earlier than the device. Within the SABME there is a command_response bit. For a SABME sent to, the command_response bit =1 For a SABME sent to, the command_response bit =0 A SABME should be responded to with a UNNUMBERED ACK. Once the link is up, layer 2 RECEIVER READY messages should be seen. These can be initiated by both and devices. They should be responded to immediately by a RECEIVER READY message from the other device. For a RECEIVER READY command sent to, the command_response = 1 For a RECEIVER READY command sent to, the command_response = 0 For a RECEIVER READY response sent to, the command_response = 0 For a RECEIVER READY response sent to, the command_response = 1 Finding the I Look at a layer 2 message in the DETAIL DECODE section; the tei is labeled Contact Details Email: support@vegastream.com Web: www.vegastream.com www.vegaassist.com EMEA Office VegaStream Limited Western Centre Western Road Bracknell Berks RG12 1RW UK +44 (0) 1344 784900 USA Office VegaStream Inc. 6200 Stoneridge Mall Road 3rd Floor Pleasanton California 94588 USA +1 925 399 6428 Version 0.3 5 July 2006 Page 8 of 8