Air Shower Biosafety Changing Station with Pass-Through Box Pass-Through Box Automatic atomizer for no-contact hand disinfection



Similar documents
LAMINAR FLOW FOR ALL YOUR NEEDS

Laminar Flow Cabinets

FlowFAST V. Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Procedures for the Effective Use of Biological Safety Cabinets

LAMINAR FLOW CABINETS

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

WIBObarrier OCS - Open Containment Systems WIBObarrier CCS - Closed Containment Systems

Spetec. Laminar Flow Box. Portable Clean Room Technology

Laminar Flow Hoods and Booths

Clinic Washer-Disinfectors. Washer-Disinfector Line

Laminar Flow Cabinets and Workstations

Risk Assessment: Biosafety Cabinet

Incubator with mechanical convection

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

BIOLOGICAL SAFETY CABINET PROGRAM

Material test chamber with mechanical convection

Spetec Laminar Flow Systems. Operating Instructions

GETINGE GEW 2100LS CAGE AND RACK WASHER PREVENTING CONTAMINATION IN ANIMAL CARE

Shakers, Incubators, Clean Benches, Water Baths, Drying Ovens

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

CelCulture. CelCulture CO2 Incubator Model CCL-170_-_. CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications

RPV - RP - RA air handling units

HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions

How To Control A Medical Device With A Pc System

Environmental Monitoring

ASALAIR BIOHAZARD CABINET MODEL ATLANTIC CYTOCABINET 1200 CLASS II TYPE A2 COD MICROBIOLOGICAL SAFETY CABINET CLASS II TYPE A2

Stainless Steel Worksurface 3 Feet Hood A10-WS-PR3 A10-WS-SR3 4 Feet Hood A10-WS-PR4 A10-WS-SR4 6 Feet Hood A10-WS-PR6 A10-WS-SR6.

LABOKLAV. Autoclaves Made in Germany.

FVA/A1 saturated-steam sterilizer

Installation, operation and maintenance manual TX 35A

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

UNITOR ULTRASONIC cleaning

Spetec. Clean room. technology. Laminar flow box Clean room workbench CleanBoy Clean room cell Service, certification

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Decontamination Showers

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Questions & Answers (Q & A) Regarding Asbestos Treatment with the Fire Suppression and Renovation Project

CHILDCARE SETTINGS. Childcare Settings

Series 18 Pass Thru Air Lock Cleanroom Entry System

STERILIZERS, LABORATORY DRYING OVENS

BSL3 and BSL4 Autoclaves. Laboratory Line

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

Heating oven with mechanical convection

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Pharmaceutical Rotary Presses. PharmaPress 800. High Speed Double Rotary Press

German engineering under high pressure

Coldrooms designed for your application

PAINT BOOTH LIGHTING

SPECIAL APPLICATIONS

Power consumption (kw)

a range of pollutant free compressors - for pure, clear, oil free air

HVAC air curtains. Type InduAir

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Sterilizers with extra class

Cleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9

PI s Name Date Bldg./Rm# CDC Biosafety Level 3 (BSL-3)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

How To Use A Ds340 (Dsp)

Environmental Monitoring of Clean Rooms

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

Biosafety Level 2 (BSL-2) Safety Guidelines

LAMINAR AIRFLOW EQUIPMENT CLASS I BIOLOGICAL SAFETY CABINETS BIOLOGICAL ENCLOSURES

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Nu/Clean 818 XLR-FB Touch Screen Inline Aqueous Cleaner Technical Specifications & Pricing

Installation Instructions

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since

Zehnder Focus 200. Ventilation device

CARE HOMES AND NURSING HOMES

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Cleanroom Solutions Ltd T: F: E: W:

LABORATORY / MEDICINE / PHARMACEUTICAL REFRIGERATORS

Heating oven with mechanical control

Equipment Information

Freezers - Ultrafreezers. Platilab & Irilab Series

High-speed folding doors. F Series

Minimizing Occupational Exposure to Hazardous Chemicals in Animal Protocols

Espresso coffee grinder

CE6500 Energy Recovery Ventilator

06 / Optional components. MAXDATA PLATINUM Server-Rack PLATINUM. [Product Guide]

LyoBeta. R+D Freeze-Dryers

Medical Waste Autoclaves. Medical Waste Autoclaves

Protection, safety, reliability. And more. LAMINAR FLOW CABINETS AND SYSTEMS

Partnership. Large Steam Autoclaves for the Life Sciences. Laboratory Line

ECOCIAT. Domestic hot water heat recovery unit

Automatic fire-extinguishing systems for commercial cooking

V1504 Vertical Platform Lift OWNER S MANUAL

WASTEWATER TREATMENT OBJECTIVES

Specification of Requirements for Ventilated Cage Rack System

SECTION MORTUARY REFRIGERATORS

Biosafety Level 2 Criteria

#9. EFFECTIVE CLEANING, MAINTENANCE, AND PEST CONTROL PROGRAMS FOR YOUR HACCP PLAN

Modular Glovebox Systems Gas Purifier Units Antechambers Accessories

Profiles for floors of same height Cerfix Projoint

Video conferencing. solutions. Communication was never that easy,

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

Transcription:

Air Shower Biosafety Changing Station with Pass-Through Box Pass-Through Box Automatic atomizer for no-contact hand disinfection A wide range of products to meet the needs of transferring animals, operators, and working tools in absolute safety and with no risk of cross-contamination.

Introduction The goal of animal and human protection in animal facilities has been achieved over the years through the development of a number of barrier systems. Animals are isolated within sealed buildings in positive, HEPA filtered air pressure mode, eating sterilized diets, living on sterilized bedding substrates and drinking microbiologically clean water. On the other side, laboratory personnel wear PPE after cleansing SOPs, carefully handling animals to limit stress and any risk of contamination. Most of these barrier systems are still successfully operating and certainly the general concept of treating materials for subsequent introduction into clean areas, protecting people and animals by means of appropriate clean apparel, showering devices, caging barrier systems etc. have all evolved dramatically over the last 20 years. Air Shower The modern Safe Barrier may differ radically in terms of design, procedures and technologies made available by the industry thanks the development of equipment that has helped to improve the working environment, contributing to safer procedures and more flexible, easier ways of working. An example of the revolution that has come about in animal facilities is the innovative use of air showers as a possible alternative to water shower systems. This is really a consequence of a reduced risk of contamination from animals for technicians and investigators working in the barriered units, thanks the introduction of IVC systems and appropriate cage handling procedures. But important changes have occurred also in terms of safer chemical substances made available to disinfect heat sensitive materials whose efficacy is comparable to that of formaldehyde but with the advantage of a negligible toxicity. Decon-Locks and Pass-Through cabinets have been purposely designed to work efficiently with hydrogen peroxide, chlorine dioxide gas and other chemicals, making it possible to disinfect large loads in a time as low as 90 minutes. Personnel protection from micro-organisms and allergens, animal protection from infective agents, improvement of the working environment, faster and more efficient disinfection processes, are all the result of technological changes on both a large and small scale. To meet the needs of transferring animals, operators, and working tools in absolute safety and with no risk of cross-contamination Tecniplast developed a wide range of products. PT60 Biosafety Changing Station Tecniplast wide experience allows us to provide you with the best solutions for your every possible need in terms of transfer between two environments with different level of contamination. Pass Through Box Apus Automatic Disinfectant Atomizer

1/ AS - Air Shower Safe transfer of operators The Air Shower is a system which allows the access and exit of operators between environments with different levels of contamination by removing polluting powders and particles from operators (or materials) in transit. Higher level of cleanliness: Tecniplast Air Shower features 22 adjustable air nozzles, so that the air flow can be better oriented. The average air velocity is 30 m/s, higher than many other similar products. Cleanability and duration of the product: completely made of stainless steel, resulting in fewer chance of the product to get scratched. Tecniplast provides inner test certifying efficiency in removing particulate contaminants. The Air Shower is designed to be installed between areas with different levels of contamination in order to minimize the amount of particulate contaminants in the clean area. Personnel move through the Air Shower while particulate contaminants are washed off by high velocity HEPA-filtered air jets coming from dedicated nozzles positioned on the sidewalls and the ceiling. 2/Functioning sequence After opening the access door and entering the Air Shower, the washing cycle is activated by pressing a dedicated push botton on the control panel. At the end of the cycle (pre-set cycle duration is 45 seconds but it is easily adjustable according to the customer requirements), the door lock is released, allowing access to the clean area. The duration of the air flow cycle is settable from a minimum of 15 seconds to a maximum of 4 minutes. 3/Air Shower - Main features All exterior and interior Air Shower surfaces are made of AISI 304 scotch brite (for easy cleanability and duration of product). HEPA filter with H14 MPPS efficiency in accordance with EN 1822. Filter access is from the interior ceiling, thus guaranteeing easy access for maintenance. The doors are made of clear anodized aluminium and sound-absorbent safety glass. The interior ceiling includes a fluorescent light that grants optimal and uniform lighting distribution on the inside. A Programmable Logic Controller (PLC) is used to control the sequence of operations of the Air Shower. The main control box with the PLC is positioned on the ceiling of the chamber and it is easy accessible for maintenance by means of an inspection removable panel positioned in the dirty area (no need to pass through the barrier for maintenance). Tempered glass doors provided with electric lock guarantee high visibility and low noise level. Door interlocks are located in the two door-jambs at the entrance and exit ways. The dirty side lock automatically releases in case of power cut loss or when the Emergency Stop button is pressed. The Emergency Stop buttons are located inside the Air Shower and outside on both sides, close to the entrance doors for maximum safety. Air Shower - Safe transfer of operators 1 Functioning sequence2 Air Shower - Main features3

1/ PT60 Biosafety Changing Station with Pass-Through Box - Safe transfer of animals In each housing facility, one of the most critical operations is receiving the animals, with the related risks of cross-contamination between clean and dirty side. That s why PT60 has been developed: it is a system allowing the operator to receive animals from a non-controlled environment to a controlled one. During the operations of box transferring carried out with PT60 the box does not have to be sterilized, since the operator on the dirty side just has to open it while it is under laminar flow and the operator on the clean side does not have to touch the box and can put the animal directly into the cage: this allows for great efficiency and quicker operations! PT60 is ideal for managing great volumes of animals with the certainty of a high level of safety and protection! PT60 - Safe transfer of animals1 2/ PT60 - Functioning description The system comprises: 1) a laminar flow pass box (ISO 5 class); 2) a bio-safety cabinet for mouse and rat cage changing. The pass-through box can be positioned on either side of the changing station. The door interlock system prevents loss of pressure balance between two separate environments. Above the pass-through chamber there is a fan that re-circulates HEPA-filtered air and distributes it inside the pass box as a uniform laminar flow, thus creating a barrier between the changing station and the environment. 1) The operator on the dirty side presses the green push button to open the door and slides the transport box containing the animals into the passthrough chamber. 2) The operator on the clean side is allowed to open the chamber on their side and to empty the box only after the door on the dirty area has been closed. 3) Finally, the operator on the dirty side can remove the box. PT60 - Functioning description2 The cabinet can also be used for all cage changing operations.

1/ PTB - Pass Through Box Safe transfer of materials and tools PT60 is designed for animal transfer, but Tecniplast offer is completed by the static interlocking pass-box, designed to transfer materials and working tools between zones with different levels of contamination, while at the same time keeping them separate. The pass-through box is made of AISI 304L scotch bright finished stainless steel panels, with two single 8mm tempered glass doors, directly hinged to the metal structure. Two interlocking electrically operated doors ensures the separation of the two environments. On both sides a green light shows when the door can be opened by pressing the adjacent button. 2/ Functioning description The static pass-box is easy to use: The first operator pushes a button to open the door on side A. The interlocking device automatically keeps the other door on side B locked while the green light on side B goes off. The items are inserted and the first operatorcloses the door. On side B the green light switches on, then the second operator can push the button and open the door to take out the items. In this phase the door on side A is locked and the green light on side A is off. Pass Through Box - Safe transfer of materials and tools1 Functioning description2 1/ APUS - Automatic atomizer for no-contact hand disinfection APUS - The machine sprays precise doses of disinfectant, validated by a procedure, and most of all, always in the same quantity, so they are not subject to human error. Safety is thus guaranteed. APUS1 APUS Automatic atomizer for no-contact hand disinfection

Electrical supply Supply voltage: Working power supply: Max. line current absorption: 400 V - 3 P+N+G 3,85 KVA 5,5 A External dimensions changing station - pass box assembly (W x D x H) Doors width Weight HEPA filter efficiency H-14 EN 1822 (MPPS) Average air velocity measured on each air nozzle Noise level Air flow cycle duration Air Shower TECHNICAL SHEET 9AS10ALxxx 1300 x 1450 x 3010 mm - 51.2 x 58 x 118.5 inch 745 mm - 29.33 inch 1153 Kg 99,995% 30 m/s - 98.4 ft/s 60 db(a) 45 sec. 45 sec. 45 sec. - From dirty to clean 10 sec. - From clean to dirty 9AS10Lxxx 1300 x 1450 x 3010 mm - 51.2 x 58 x 118.5 inch 695 mm - 27.36 inch Clean side 745 mm - 29.33 inch Dirty side 1153 Kg 99,995% 30 m/s - 98.4 ft/s 60 db(a) From dirty to clean From clean to dirty Two ways cycle Air Shower Options Electric Configuration: - 400V 50Hz (3P+N+G) Door position configurations: - in line - 90 Door opening direction configurations: - 12 available different configurations Cyle type configuration: - One way cycle unclean - clean - One way cycle clean - unclean - two ways cycle Lock type for clean door: - Normally open - Normally close Electrical supply Supply voltage: Working power supply: Weight: Appliance net weight: 230 VAC 50 Hz 0,4 A 85 Kg / 70 Kg Pass through box TECHNICAL SHEET Size (L x W x H): External dimensions: Internal dimensions: 700 x 600 x 1050 mm / 600 x 600 x 670 mm - 27.56 x 23.62 x 41.34 / 23.62 x 23.62 x 26.38 inch 635 x 570 x 900 mm / 480 x 600 x 540 mm - 25 x 22.44 x 35.43 / 18.9 x 23.62 x 21.26 inch Pass Through Box Options Electric Configuration: - 8 different electric configurations: 230V 50/60Hz; 100V 50/60Hz; 115V 50/60Hz Available in two different dimensions: - Small size 600 x 600 x 670 mm - 23.62 x 23.62 x 26.38 inch (W x D x H) - Large size 700 x 600 x 1050 mm - 27.56 x 23.62 x 41.34 inch (W x D x H) Door opening direction configuration: - 4 different available configurations Floor base configuration: - With stainless steel base from floor - Without stainless steel base from floor

Electrical supply Supply voltage: Working power supply: Max. line current absorption: PT60 Options Electric Configuration: - 9 different electric configurations: 230V 50/60Hz; 100V 50/60Hz; 115V 50/60Hz Pass-through Box configurations: - one door - two interlocking doors Door configuration in reference to the front of the Pass Through Box: - Right side - Left side Position of the Pass Through Box in reference to the front of cabinet: - Right side - Left side PT60 TECHNICAL SHEET 230 VAC 50/60 Hx - 115 VAC 60 Hz - 100 VAC 50/60 Hz 1,8-2,3 KVA 22 A External dimensions changing station - pass box assembly (W x D x H) Working area changing station (W x D x H) Working area pass box (W x D) Front access opening cabinet Front access opening external pass box Weight HEPA filter efficiency H-14 EN 1822 (MPPS) Recirculation/Exhaust Exhaust air volume Air velocity - downflow Air curtain velocity Noise level 9PT60AU - xxxxx 2115 x 895 x 2208 mm - 83.27 x 35.24 x 86.93 inch 1486 x 535 x 740 mm - 58.5 x 21.06 x 29.13 inch 485 x 244 mm - 19.1 x 9.6 inch 290 mm - 11.4 inch 495 mm - 19.5 inch 485 Kg 99,995% 60% / 40% 900 m 3 /h - 530 cf/m 0,35 m/s - 1.15 ft/s 0,55 m/s - 1.8 ft/s 60 db(a) 9PT60BU - xxxxx 2345 x 895 x 2208 mm - 92.32 x 35.24 x 86.93 inch 1486 x 535 x 740 mm - 58.5 x 21.06 x 29.13 inch 485 x 552 mm - 19.1 x 21.7 inch 290 mm - 11.4 inch 440 mm - 17.3 inch 555 Kg 99,995% 60% / 40% 900 m 3 /h - 530 cf/m 0,35 m/s - 1.15 ft/s 0,55 m/s - 1.8 ft/s 60 db(a) Electrical supply Supply voltage: Working power supply: Max. line current absorption: Weight: Appliance net weight: Size (L x W x H): Atomisation time: Tank maximum capacity: Apus TECHNICAL SHEET 230 VAC 50/60 Hz - 115 VAC 60 Hz - 100 VAC 50/60 Hz 12 V - 20 W 30 W 5 Kg 220 x 270 x 405 mm - 8.66 x 10.63 x 16 inch Continuos when the photocell is activated 950 ml Apus Options Electric Configuration: - Universal battery ( 230V 50/60Hz; 100V 50/60Hz; 115V 50/60Hz) Installation configurations: - Stand alone - With wall mounting frame - With sliding system for changing station (CS5;Interactive; BS48;BS60;PT60;)

Related Products To maximise operational efficiency and learn more about these products contact your local representative. BS48. TÜV certified Class II Laminar Flow Cabinet. Sealsafe Plus. High containment, certified protection from allergens, high density and practicality of use. The IVC (r)evolution. Sealsafe Plus RAT. High containment, protection from allergens, high density and practicality of use. HEADQUARTERS ITALY Tel. +39 0332 809711 www.tecniplast.it E-mail: tecnicom@tecniplast.it sister companies AUSTRALIA/NEW ZEALAND Tel. + 61 2 8845 6500 www.tecniplast.it E-mail: info@tecniplast.com.au FRANCE Tél. 04 72 52 94 41 www.tecniplast.fr E-mail: info@tecniplast.fr GERMANY Tel. 08805 921320 www.tecniplast.de E-mail: info@tecniplast.de UNITED KINGDOM Tel. 0845 0504556 www.tecniplast.it E-mail: info@tecniplastuk.com JAPAN Tel. + 03 5770 5375 www.tecniplast.it E-mail: info@tecniplastjapan.co.jp USA/CANADA Toll Free: 877.669.2243 www.tecniplastusa.com E-mail: info@tecniplastusa.com To find your local distributor, please visit www.tecniplast.it ISO-9001 - Cert. n 0875 ISO-14001 - Cert. n 0256A/0 Tecniplast reserves the right to change or modify product and or specifications without notice or obligation. Safe Barrier Solutions, Air Shower, PT60, Pass Through Box and Apus are Tecniplast trademarks. CAT096/ING - Rev. June 2012