MAC 5000 ECG System. GE Medical Systems Information Technologies. Clinical excellence and workflow productivity



Similar documents
GE Healthcare. Rest assured. MAC 5500 resting ECG analysis system

Simpler on the outside. Smarter on the inside.

GE Healthcare. MAC 2000 ECG Analysis System Streamlined for your hospital

Philips PageWriter Touch ECG System

GE Healthcare. The new MAC * 800

GE Healthcare. The ECG with more knowledge built in Introducing the MAC * 5500 HD

GE Healthcare. The heart of cardiology is connectivity The MUSE * v8 Cardiology Information System

Introducing the first 12-lead for the BLS team.

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

GE Healthcare CASE. Cardiac Assessment System for Exercise Testing. Connecting hearts and minds.

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

DASH PRO VARIABLE-ACUITY MONITORING. Connecting you to the right information no matter where patient care takes you. gemedical.com

GE Healthcare CASE. Cardiac Assessment System for Exercise Testing. Connecting hearts and minds.

Company Profile & product presentation.

CardioSoft * Diagnostic System

Datex-Ohmeda Critical Care Monitor

U1602A Handheld Oscilloscopes, 20 MHz

Data Sheet FUJITSU Display E19-7 LED

R&S ZNC Vector Network Analyzer Specifications

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Wi-Fi Barcode Scanner

Agilent 4339B/4349B High Resistance Meters

Agilent Technologies 3000 Series Oscilloscopes

Operating Instructions

touchecg Reference Markets your profession, our mission

Power Meter Series 700

SMART Board interactive flat panel with appliance Model 8055ie-SMP

5000V Graphical Megohmmeter Model 5070

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Duct Humidity Transmitter

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Redundancy Module QUINT-DIODE/40

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Always in touch. Philips PageWriter TC50 cardiograph

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

Data Sheet FUJITSU Display L27T-1 LED Display

QuickSpecs. HP Digital Sketch Overview

SignalPad Data Logging and Analysis Software

Everything you need for protection scheme testing

iva Cable & Antenna Analyzer

Agilent E6020B FTTx OTDR

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

GE Healthcare. Ready. Set. Acquire. CardioSoft diagnostic software

Data Sheet FUJITSU Display Display E22T-7 LED

510(k) Summary May 7, 2012

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

1701/22 FieldMonitor Management Interface Module

SMART Board Interactive Display Model SBID8070i

How To Use A Detector 2

Multi-Range Programmable DC Power Supplies 9115 Series

Telephone- and leased line modem for industrial applications TD-36

RM4TG20 three-phase network control relay RM4-T - range V

rigel 288 Electrical Medical Safety Analyser Key Features Applications

MAJORSINE Power Inverter

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

NI USB-5681 RF Power Meter Specifications

DC Electronic Loads 8500 series

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

FREJA 300 Relay Testing System

DCS Series 1 kw, 1.2 kw, & 3 kw

Frequency selective monitoring and logging of environmental electromagnetic fields

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

PT-LB55NT S P E C F I L E. Micro-Portable Wireless LCD Projector. As of February Specifications subject to change without notice.

IFC 070 Technical Datasheet

Multi-Function Ground

Analog signal converters CC-E I/I Current / current isolators

Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family

R&S ZNBT8 Vector Network Analyzer Specifications

Mobile POS Tablet Barcode Scanner

3200L 32" Interactive Digital Signage Touch Display

BASIC SOUND LEVEL METERS

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

iva Cable & Antenna Analyzer

Waveguide Access Point WGA631. Product Guide

Data Sheet Fujitsu Display B19-7 LED Displays

10 Multimeter. Users Manual

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

T Substation Maintenance and Commissioning Test Equipment

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System

Product Data. Thermal Comfort Data Logger Type Including Application Software Type 7301

LT-82 Stationary IR Transmitter

Lockout Specification BW Clip Maintenance-free single gas detector

Agilent 87421A/87422A Power Supply

Data Sheet FUJITSU Display B24T-7 LED Displays

TORKEL 820 Battery Load Unit

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Scout 1U Rackmount Computer

CARESCAPE VC150 Vital Signs Monitor. Connecting intelligence and care.

Cisco Unified IP Phone Power Injector

Multi-Range Programmable DC Power Supplies 9115 Series

Foxboro Evo Process Automation System

WXGA (1280 x 800), 3500 lumens, up to 7,000 hours lamp, HDMI, throw ratio, wireless ViewSync

Cardiac Conduction System (1) ECG (Electrocardiogram) Cardiac Conduction System (2) The ECG (1) The ECG (1) The ECG (1) Achmad Rizal BioSPIN

Transcription:

GE Medical Systems Information Technologies MAC 5000 ECG System Clinical excellence and workflow productivity Non-Invasive Cardiology Product Sheet MAC 5000, GE s premier ECG system, delivers advanced disease management capabilities through its vast collection of proven algorithms. The MAC 5000 system offers the sophistication required for advanced ECG applications, while its ease of use extends this level of performance to the broadest range of users possible. And it s part of the complete GE suite of networked, non-invasive testing solutions designed to maximize patient throughput and department productivity. Add the stress option, and you combine the industry s leading highperformance resting ECG system with comprehensive, equally advanced exercise-testing capabilities in a single, compact system. Built on GE s proven performance in ECG analysis: Advanced algorithms set the standard in ECG analysis and interpretation. Easy-to-use applications and features streamline productivity and workflow. Seamless connectivity to the MUSE Cardiology Information System speeds data storage and ECG retrieval. Comprehensive training helps maximize your return on investment. Now with new features that expand your capabilities: Barcode and magnetic card scanning options help reduce patient data errors. New trolley incorporates customer-requested ease-of-use features. XML capabilities ensure flexible, open communications. User-configurable password protection addresses security concerns.

Setting the mark for clinical validity and excellence in ECG analysis Since the introduction of the Marquette 12SL ECG analysis program in 1980, GE Medical Systems Information Technologies has steadily expanded its electrocardiograph-based suite of ECG analysis programs and capabilities. Today, we continue to lead developments in computerized ECG analysis, setting even higher levels of clinical accuracy, validity, and performance. Through extensive clinical evaluation and the use of classic and newly developed ECG interpretation criteria and measurement technologies, we steadily refine and improve our state-of-the-art suite of ECG analysis programs. Regular clinical input from the world s top consulting cardiologists and physicians helps our own research and development engineers enhance our programs. Ongoing acquisition of clinically correlated, gold-standard databases allow us to continually evaluate and verify our algorithm performance. Use of the same patient assessment tests employed by practicing physicians ensures clinically accurate values. Rapid assessments and improvements on very large databases are made possible by sophisticated analysis techniques, developed by our own engineers, that enable us to quickly evaluate the accuracy of our ECG analysis programs. Our commitment to improving the science of ECG analysis has led to the use of our algorithms across GE s diagnostic and monitoring systems. This implementation makes our programs the preferred choice in a variety of care settings and industries including hospitals, clinics, physician offices, and clinical research organizations (CRO s).

A complete suite of analysis algorithms for advanced ECG applications With the MAC 5000 s arrhythmia and chest pain assessment tools, you can address a wider range of disease management needs, make more efficient decisions, and use involved invasive tests more judiciously. Ongoing development by one of the industry s leading algorithm design staff provides the latest in advanced capabilities, while validation against clinically-verified databases offers unmatched accuracy across a diverse range of patient populations, from pediatrics to adults. Marquette 12SL ECG Analysis Program for Adults and Pediatrics the industry s most thoroughly documented, simultaneous 12-lead ECG acquisition analysis program for uncompromising quality and reliability remains your most clinically valuable second opinion. Marquette 12SL with Gender-Specific Interpretation features criteria that help you more easily detect acute myocardial infarction (MI) in female patients, enhancing diagnostic confidence even among occasional readers of ECGs. Marquette 12SL with ACI-TIPI (Acute Cardiac Ischemia Time-Insensitive Predictive Instrument) this option considers a patient s age, gender, and chief complaint as well as ECG measurements to generate a numerical score that helps predict the probability of acute cardiac ischemia and provides important additional triage information for patients with chest pain. Simultaneous 15-Lead Acquisition, Storage, and Assessment provides additional ST measurements for the detection of changes that occur in some nondiagnostic 12-lead cases to facilitate the prompt detection of right ventricular and posterior MI. P-Wave Signal Averaging option for atrial arrhythmia assessment features a patented templating algorithm that enhances P-wave measurement accuracy. Hi-Res Late Potential Analysis option supports effective ventricular arrhythmia assessment, with an intuitive design that creates a practical, non-invasive alternative to involved invasive testing. Enhanced Pacemaker-Detection Software improves sensitivity to electronically paced hearts. Serial ECG Comparison program, through the MUSE Cardiology Information System, leverages the Marquette 12SL ECG analysis program and analyzes both shortand long-term changes in patient s ECGs.

Features to enhance productivity and workflow Specifically designed to enhance your entire staff s efficiency, the MAC 5000 combines technological advances with ease-of-use features in one system. The digital CAM-14 Module reduces noise and artifact for clearer ECG tracings. Large field-of-view display gives you a clear view of the screen from any angle. Analog ECG output facilitates easy integration with other cardiacdiagnostic devices, such as echocardiography and nuclear medicine systems. Compact system design offers easy mobility. Extensive customization including display and final-report formatting accommodates individual user preferences. Trolley design features a convenient holder for the acquisition module, ample writing surface area, wider bins, and a covered storage compartment. The MAC 5000 s stress option incorporates our leading exercise-testing technologies. Signal-acquisition advances help reduce baseline wander and ST-segment distortion to generate clearer, more well-defined ECGs. Barcode and magnetic card reader options help reduce errors by automating the input of patient data. Barcode and magnetic card reading options

Complete connectivity and network access for improved accuracy and decision support Tap into the power of GE s MUSE Cardiology Information System the industry s predominant cardiology management system to take full advantage of your resting ECG patient information records. Access results from the clinic, office, or other remote facility using a standard modem for maximum decision-making efficiency. Export and store data in XML format. Quickly retrieve, manage, and archive patient data through seamless, bidirectional communication with the MUSE System. Instantly access procedure requests and download patient demographic data from the MUSE System and Order Manager. This functionality reduces time-consuming patient data entry and minimizes delays in procedure billing. Review results or access the computer ECG patient record immediately, any time of day or night, using the Remote Query option for more responsive patient care.

Performance Specifications Performance Specifications (cont.) Instrument type Microprocessor augmented automatic electrocardiograph; 14 -leadwire acquisition with programmable lead configuration Processing ECG Interpretation: Marquette 12SL ECG Analysis Program for Adults and Pediatrics Computerized 15-lead analysis includes Measurements: measurements of user-selectable additional 3 leads Optional: Hi-Res Late Potential Analysis and P-Wave Signal Averaged ECG Additional ECG Vectorcardiography Function: ECG Analysis 500 samples/second (sps) Frequency: ECG Storage: 150 typical, 200 ECGs maximum on removable media (1.44 MB, 3.5 in diskette) 15 typical in XML format Digital Sampling Rate: 4000 samples/second/channel Pre-Acquisition: Provides 10 seconds of instantaneous ECG acquisition Dynamic Range: AC Differential ±5 mv DC offset ±320 mv Resolution: 4.88 µv/lsb @ 250 sps 1.22 µv/lsb @ 500 sps Frequency Response: 3 db @ 0.01 to 150 Hz Common Mode >140 db (123 db with Rejection: AC filter disabled) Input Impedance: >10M Ω@ 10 Hz, defibrillator protected Patient Leakage: <10 µa Pace Detect: Orthogonal LA, LL, and V6; 750 µv @ 50 µs Special Acquisition Disconnected lead Functions: detection, electrode impedance, excessive AC noise, baseline wander and muscle tremor messages Heart Rate Meter: 30 to 300 BPM ±10% or 5 BPM, whichever is greater. Heart rates outside this range will not be displayed. Communications MUSE Cardiology Information System compatible Optional: Modem and Fax transmission, Remote Retrieval (Remote Query) Display Display Type: Display Resolution: Display Data: Writer Writer Technology: Writer Speeds: Number of Traces: 10.4 in (264 mm) diagonal graphics backlit AM LCD (color optional) 640 x 480 pixels with waveform enhancement Heart rate, patient name, ID, clock, waveforms, lead labels, speed, gain and filter settings, warning messages, prompts, and help messages Thermal dot array 5, 12.5, 25, & 50 mm/s (same as displayed) 3, 6, 12, or 15, user-selectable (same as displayed) Writer Sensitivity/Gain: 2.5, 5, 10, 20, 10/5 (split calibration) mm/mv (same as displayed) Writer Speed Accuracy: ±2% Writer Amplitude ±5% Accuracy: Writer Resolution: Horizontal 1000 dpi @ 25 mm/s, 200 dpi vertical Paper Type: Thermal, Z-fold, perforated, fan fold, 300 sheets/pack Paper Size: A Size: 8.45 in x 11 in (214.63 mm x 280 mm) A4 Size: 8.27 in x 11.7 in (210 mm x 297.5 mm) Keyboard Type: Sealed elastomer with soft function keys, alphanumeric keys, writer controls, and TrimPad cursor controls Electrical Power Supply: AC or battery operation Voltage: 100 to 240 VAC +10, 15% Current: 0.5A @ 115 VAC, 0.3A @ 240 VAC, typical Frequency: 50 to 60 Hz ±10% Battery Type: User replaceable, 18V @ 3.5 AH ±10% rechargeable NiMH Battery Capacity: 100 single page reports (typical) or 6 hours continuous display (without printing) Battery Charge Time: Approximately 4.5 hours from total discharge (with display off)

Performance Specifications Vectorcardiography Report Formats: Sensitivity: Time Resolution: Vector loops of component vectors (P, QRS, ST-T) 20, 40, 80, or 160 mm/mv 2 ms Hi-Res Late Potential Analysis and P-Wave Signal Averaged ECG Frequency 3 db @ 0.01 and Response/Input: 250 Hz Frequency Response/Output: Upper Limit: 250 Hz Lower Limit: 0.01, 25, 40, or 80 Hz Sensitivities: Raw Data Template: 20 mm/mv Average Beat: 20 mm/mv and 50 mm/mv Filtered Signals and 1 mm/µv Vector Magnitude: Analysis Sampling 1000 samples/ Rate: second/channel Digital Sampling 4000 samples/ Rate: second/channel High/Low Pass Filters: Special filter using Fast Fourier Transform (FFT) ADC Resolution: 1.22 µv/lsb Analysis Resolution: 0.1525 µv/lsb Physical Specifications 3.7 in (9.4 cm)* with display closed 15 in (38.1 cm)* Depth: 13.8 in (35.1 cm)* Weight: Approximately 6.8 kg (15 lbs)* including battery without paper Environmental Specifications Temperature: Operating: 50 to 104 F (10 to 40 C) Transport/Storage: 40 to 158 F ( 40 to 70 C) Humidity: Operating: 20% to 95% RH non-condensing Transport/Storage: 15% to 95% RH non-condensing Pressure: Operating: 700 to 1060 hpa Transport/Storage: 500 to 1060 hpa * without cart Trolley Specifications Dimensions: Depth: Temperature with acquisition module holder Weight: 39 in (99 cm) 21 in (54 cm) 28 in (72 cm) 52.5 in (134 cm) 55 lbs (25 kg) Magnetic Card Reader Specifications Character Set ANSI/ISO ALPHA alphanumeric characters and ANSI/ISO BCD (subset of ASCII (ISO 646 IRV:1991)) Dimensions: 1.17 in (28 mm) Length: 3.94 in (100 mm) 1.34 in (34 mm) Temperature Range 50 F to 104 F Operating: (-10 C to 40 C) Humidity: 10% to 90% humidity Agency Conformance: Complies with FCC Class A. CE: The system has been tested to and conforms with the provisions within 89/336/EEC, Electromagnetic Compatibility directive (EMC) Keyboard Wedge/Decoder Specifications Dimensions: 1.18 in (3.0 cm) Length: 3.25 in (8.3 cm) 2.88 in (7.3 cm) Electrical: Complies with UL, CSA, and VDE Temperature Ranges: Operating: 32 F to 104 F (0 C to 40 C) Storage: 40 F to 158 F (-40 C to 70 C) Humidity: 0% to 95% non-condensing Mechanical Shock: Functions normally after twelve 6ft.(1.8 cm) drops onto a concrete surface EMI Radiation: FCC Class A and **EN55022 Class B (1988) ESD Sensitivity: Meets **IEC 801-2: 1991/1984 and a minimum of 300 discharges at 2.5kv intervals from 2.5kv to 17.5kv Radiated Susceptibility: Meets **IEC 801-3; 1984 Electrical Fast Meets **IEC 801-4; 1988 Transients: **These requirements combined with EN50082-1; 1992 indicate conformity to the EMC directive 89/336/EEC

Bar Code Scanner Specifications Symbologies: Code 39 (extended), PDF- 417 Dimensions: 6.0 in (15.2 cm) Length: 5.3 in (13.5 cm) 3.1 in (7.9 cm) Light Source: 630 nm visible red LED Temperature Ranges: Operating: 32 F to +122 F (0 C to 50 C) Storage: -4 F to +140 F (-20 C to +60 C) Humidity: 0 to 95% non-condensing Mechanical: Operational after 25 drops from 5 feet (1.53 m) to concrete Vibration: Withstands 5G peak from 20 to 300 Hz ESD Sensitivity: 15 kv to any external surface Agency Compliance: FCC Class B, EMC Class B, CE Low Voltage Directive, EN60825-1, IEC60825-1 LED Safety: Class 1, UL, cul, TÜV Certified to EN60950, C-Tic Certification UL classification, CSA classification, CE marked in accordance with the Directive 93/42/EEC for Medical Devices, CB certified Warranty Standard warranty is one year Ordering Information Available in: Dutch, English, French, German, Italian, Spanish, Swedish, Japanese, Danish and Norwegian Visit gemedical.com or contact your local GE Medical Systems Information Technologies representative. Accessories available from www.gemedical.com Information Technologies European Headquarters GE Medical Systems Information Technologies GmbH P.O. Box 60 02 65 79032 Freiburg, Germany Tel. +49 761 45 43-0 Fax +49 761 45 43-233 General Electric Company reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. Contact your GE representative for the most current information. 2004 General Electric Company 228 259 02-2004.01-V7.0 Printed in Germany World Headquarters GE Medical Systems Information Technologies, Inc. 8200 West Tower Avenue Milwaukee, WI 53223, USA Tel. +1 414 355 5000 Fax +1 414 355 3790 Asia Pacific GE Medical Systems Information Technologies Asia 24F Floor, Shanghai MAXDO Center, No. 8 Xing Yi Road, Hong Qiao Development Zone Shanghai 200336, P.R. China Tel. +86 21 5257 4650 Fax +86 21 5208 2008