Metal-on-Metal Hip Systems

Similar documents
FDA Executive Summary Memorandum Metal-on-Metal Hip Implant Systems

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE. Health Technology Appraisal

Appendix B: FDA Safety Communication (Website) for MoM Hip Systems

Clinical Testing for Metal-on-Metal Prosthetic Wear and Tear

Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y

BIRMINGHAM HIP Resurfacing (BHR ) System PATIENT INFORMATION

Hip Resurfacing (Re-Review)

BONE PRESERVATION STEM

Answers to commonly asked questions from patients with metal-on-metal hip replacements / resurfacings. Contents

We have carefully reviewed your questions and the recent promotion for your program on the ABC website.

Randal S. Ford. ATTORNEY AT LAW (205) DePuy ASR Hip Implant Recall Fact Sheet

Cormet Hip Resurfacing System

A Magazine Dedicated to Mass Torts Law. The Dangers of Metal-on-Metal Hips. Details of DePuy ASR Settlement Announced.

DHCPL_RA EXT Page 1 of 6

DePuy Orthopaedics ASR Recall Reference Guide for U.S. Healthcare Professionals

Metal on Metal Hips. Total Hip Replacement. Total Hip Replacement

Why an Exactech Hip is Right for You

Robotic-Arm Assisted Surgery

Modular Dual Mobility Acetabular Components: An Important Extension of a Proven Approach to Hip Instability

Total Hip Joint Replacement. A Patient s Guide

.URGENT DEVICE CORRECTION

Disclosures. ! Consultant. ! Stryker. ! Smith and Nephew. Why Resurface? ! Save bone the day of surgery. ! No bone loss from stressshielding

Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics

Patient Labeling Information System Description

on-metal Hips: Device Mechanics and Failure Modes

IN THE FEDERAL COURT OF AUSTRALIA (FCA) NEW SOUTH WALES REGISTRY - FEDERAL COURT OF AUSTRALIA

frequently asked questions Knee and Hip Joint Replacement Technology

Hip Resurfacing 2011 ORIGINAL ARTICLE. James W. Pritchett MD. Introduction. Abstract

Medical Device Alert. Device All metal-on-metal (MoM) hip replacements. Action by. CAS deadlines. Ref: MDA/2012/036 Issued: 25 June 2012 at 11:00

510(k) Summary of Safety and Effectiveness JUN Hip prosthesis

Summary of Safety and Effectiveness

TOTAL HIP REPLACEMENT FOR A LIFETIME: THE CEMENTLESS METAL ON METAL RECONSTRUCTION

The Right Choice. Exeter. total hip system

Total Hip Replacement

Defective Metal on Metal Hip Implant Claims in Federal Multidistrict Litigation: More Than 8,500 Filed Cases By Hadley L.

Anterior Hip Replacement

VERILAST Technology for Hip Replacement Implants

YOUR GUIDE TO TOTAL HIP REPLACEMENT

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE

IN THE FEDERAL COURT OF AUSTRALIA (FCA) NEW SOUTH WALES REGISTRY - FEDERAL COURT OF AUSTRALIA

PMA P Cormet 2000 Hip Resurfacing System

PRESENTATIONS/PAPERS INTERNATIONAL. RAISING STANDARDS IN JOINT ARTHROPLASTY Course Co-Chairman, The Great Debate - London, June 2013

TOTAL HIP REPLACEMENT: MODERN SURGERY FOR SEVERE ARTHRITIS OF THE HIP

Arthritis of the Shoulder

ANNEXES. Medical device approval process. Annex II IMB safety notice, 27 August Annex III IMB ASR press statement.

Technology Breakthrough in Spinal Implants (Technical Insights)

Your Practice Online

HIP RESURFACING ARTHROPLASTY

Metasul LDH Large Diameter Head

DEC V,(9/azO (c 0 j

ReCap Product Rationale

Hip Replacement Surgery Understanding the Risks

HIP JOINT REPLACEMENT

Introduction to the Bertram Hip Spacer

UNITED STATES DISTRICT COURT DISTRICT OF MINNESOTA

Clinical performance of endoprosthetic and total hip replacement systems

W40 Total prosthetic replacement of knee joint using cement

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology

Clinically Proven Fiber Metal Material. Power to choose advanced bearing technologies to match patient demands

.org. Arthritis of the Hand. Description

Metal-on-metal hip implants

.org. Shoulder Joint Replacement. Anatomy

Metal on Metal Vs Other Bearing Surfaces in Total Hip Replacement

it s time for rubber to meet the road

M 2 a-magnum. Design Rationale. Large Metal Articulation. Knees Hips Extremities Cement and Accessories PMI. Technology

TOTAL HIP REPLACEMENT

P REPLACEMENT SURGERY

The Journal of Arthroplasty

Disclosures. Complications of Wear or Corrosion of Chrome-Cobalt Hip Implants. Where are we going? 21 st Century Cures Act.

The Cobalt and Chromium Conundrum: A Survey of Hip Implant Litigation, Part II

Integra. MCP Joint Replacement PATIENT INFORMATION

IMPORTANT PRODUCT RECALL UPDATE RA EXT_2

The safety of Metal-on-Metal joint replacements with a particular focus on hip implants

Global Hip Implant Market

ARTHROSCOPIC HIP SURGERY

Zimmer Durom Cup problems could have been discovered sooner

September 25, Dear Ms. McCoy:

Procedure Information Guide

Total Shoulder Arthroplasty


Exeter X3 RimFit. Acetabular Cup Surgical Protocol

HEADER TOTAL HIP REPLACEMENT SURGERY FROM PREPARATION TO RECOVERY

Anterior Approach. to Hip Replacement Surgery

Further information You can get more information and share your experience at

Wear-contact analysis of hip implant coated with functionally graded material

Hip Replacement. Department of Orthopaedic Surgery Tel:

Hip and Knee Orthopedic Surgical Implants Market Shares, Strategies, and Forecasts, Worldwide, 2016 to 2022

TOTAL KNEE REPLACEMENT: MODERN SURGERY FOR SEVERE ARTHRITIS OF THE KNEE

J&J Said to Offer Implant Pact That May Reach $2 Billion

Transcription:

Meeting of the Orthopaedic and Rehabilitation Devices Advisory Panel June 27-28, 2012 Metal-on-Metal Hip Systems Center for Devices and Radiological Health U.S. Food and Drug Administration

Meeting of the Orthopaedic and Rehabilitation Devices Advisory Panel June 27-28, 2012 Metal-on-Metal Hip Systems Elizabeth Frank, MS Biomedical Engineer Orthopedic Joint Devices Branch Division of Surgical, Orthopedic and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health

Overview of Hip Arthroplasty Hip arthroplasty relieves pain and restores joint function Hip arthroplasty has been available in the United States (US) for over 50 years Approximately 400,000 hip arthroplasty procedures performed in the US annually 3

Total Hip Replacement (THR) Surgery Diseased femoral head replaced with a femoral head and stem Acetabular socket replaced with a metal cup with a polyethylene, metal or ceramic liner Different bearing combinations Metal on Polyethylene (MoP) Ceramic on Polyethylene (CoP) Metal on Metal (MoM) Ceramic on Metal (CoM) Ceramic on Ceramic (CoC) 4

Resurfacing Hip Replacement Surgery Replaces only the upper surface of the femoral head Preserves more of the native femoral bone Requires stronger bone stock, generally younger patients Metal on Metal articulating components 5

General Hip Replacement Risks The following short and long term complications are associated with any hip replacement surgery. Infection Venous thrombosis Intra-operative nerve injury Vascular injury/bleeding Post-operative leg length inequality Dislocation of the head from the socket Post-operative nerve palsy Implant wear Prosthesis loosening Implant breakage/fracture Heterotopic ossification Femoral neck fracture (resurfacing hip systems) 6

MoM THR Systems: Indications for Use Skeletally mature patients with the following conditions: Non-inflammatory degenerative joint disease (NIDJD) such as osteoarthritis, avascular necrosis, post-traumatic arthritis, ankylosis, protrusio acetabuli, and painful hip dysplasia Inflammatory degenerative joint disease such as rheumatoid arthritis Correction of functional deformity, and Revision procedures where other treatments or devices have failed 7

MoM THR Systems: Contraindications Bone or musculature compromised by disease, prior infection, or prior implantation that cannot provide adequate support or fixation for the prosthesis Any active or suspected infection in or about the hip or distant foci Skeletal immaturity Metal sensitivity Patients who are pregnant or who may become pregnant, and Patients with known moderate to severe renal insufficiency 8

MoM THR Systems: FDA Regulation Class III preamendment devices Call for Premarket Approval (PMA) Applications has not been proposed Regulated as Class III 510(k) devices Initial MoM THR design from each manufacturer supported with clinical data Modifications to existing systems supported by preclinical testing with clinical data required for significant changes 9

MoM THR Systems Marketed in the U.S. As of May 30, 2012, FDA has cleared 188 510(k) submissions from 21 manufacturers for MoM THR systems Many of these are for additional components or modifications to previously cleared systems Manufacturers have been purchased by other manufacturers or no longer market MoM hip systems 10

Manufacturers of MoM THR Systems Marketed in the U.S. 1. Biomet, Inc. 2. DePuy Orthopaedics, Inc. 3. Encore Medical, L.P. 4. Wright Medical Technology, Inc. 5. Zimmer, Inc. 11

MoM THR Systems: Characteristics Acetabular Shell Monoblock Modular with metal liner Modular with metal insert in polyethylene liner (poly sandwich) Articulating component Material: Cobalt-chromium-molybdenum (CoCrMo) alloy ASTM F1537 Wrought ASTM F75 Cast High carbon content (0.15 0.35 mass percent chemical composition) Inner Diameter ranges from 28-60mm 12

MoM THR Systems: Characteristics Acetabular Shell Shell material Titanium alloy (ASTM F136) or CoCrMo alloy (ASTM F1537 or ASTM F75) Outer Diameter ranges from 44-80mm Methods of Fixation Cemented Porous or non-porous metallic coatings Calcium phosphate coatings 13

MoM THR Systems: Characteristics Femoral Head Cobalt-chromium-molybdenum (CoCrMo) alloy ASTM F1537 Wrought ASTM F75 Cast High carbon content (0.15 0.35 mass percent chemical composition) Diameters range from 28-60mm Range of neck offsets Larger heads may have taper sleeve adapter 14

MoM THR Systems: Characteristics Femoral Stem CoCrMo alloy (ASTM F1537 or ASTM F75) Titanium alloy (ASTM F136) Methods of Fixation Cemented Porous or non-porous metallic coatings Calcium phosphate coatings Diametrical Clearances range from 50 250 µm 15

MoM Hip Resurfacing Systems: Indications for Use Intended for reduction or relief of pain and/or improved hip function in skeletally mature patients having the following conditions: Non-inflammatory degenerative arthritis such as osteoarthritis, traumatic arthritis, avascular necrosis, or dysplasia/developmental dislocation of the hip (DDH); or Inflammatory arthritis such as rheumatoid arthritis. Resurfacing systems are intended for patients who, due to their relatively younger age or increased activity level, may not be suitable for traditional total hip arthroplasty due to an increased possibility of requiring ipsilateral hip joint revision. 16

MoM Hip Resurfacing Systems: Contraindications Infection Skeletal immaturity Inadequate bone stock Severe osteopenia Osteonecrosis or avascular necrosis (AVN) with >50% involvement of the femoral head (regardless of FICAT Grade) Cysts of the femoral head (>1cm) Vascular insufficiency, muscular atrophy, or neuromuscular disease severe enough to compromise implant stability or postoperative recovery Females of child-bearing age Moderate to severe renal insufficiency Immunosuppressed with diseases such as AIDS or persons receiving high doses of corticosteroids Obesity and/or with a BMI>35 Metal sensitivity (e.g., jewelry) 17

MoM Hip Resurfacing Systems: FDA Regulation Class III devices requiring Premarket Approval (PMA) Applications Each manufacturer must demonstrate a reasonable assurance of safety and effectiveness through preclinical and clinical performance data Conditions of Approval: Post Approval Studies Long-term outcomes General use of the device Training programs 18

MoM Resurfacing Systems Marketed in the U.S. Sponsor Device Date of Approval PMA Number Smith & Nephew Orthopaedics, Inc. Birmingham Hip Resurfacing (BHR) System May 9, 2006 P040033 Corin Medical, Ltd. Cormet Hip Resurfacing System July 3, 2007 P050016 Wright Medical Technology, Inc. CONSERVE Plus Total Resurfacing Hip System Nov. 3, 2009 P030042 19

MoM Resurfacing Systems: Characteristics Acetabular shell Cast CoCrMo (ASTM F75) 44 66mm outer diameter, 36-58mm inner diameter Metallic coating, with some also having a calcium phosphate coating Resurfacing femoral head Cast CoCrMo (ASTM F75) 36 58mm diameter Cemented 20

Intended Benefits of MoM Hip Systems Relieve pain and improve function Larger diameter heads closely mimic natural anatomy Intended to improve stability and reduce incidence of dislocation Resurfacing systems provide for greater preservation of femoral bone stock 21

Issues Associated with MoM Hip Systems Wear of articulating components may lead to the production and accumulation of metal ions and debris Cup malpositioning may increase wear rates Reaction to particulate is patient specific No reaction Mild hypersensitivity Severe inflammatory response Increases in potential safety issues, include: Local complications, such as pseudotumors and aseptic lymphocytic vasculitis-associated lesions (ALVAL) Commonly referred to as adverse local tissue reaction (ALTR) or adverse reaction to metal debris (ARMD) Early device failure and need for revision surgery Systemic complications from metal ion exposure 22

Regulatory Actions Australian Therapeutic Goods Administration (TGA) Review of data from Australian National Joint Replacement Registry (NJRR) showed higher revision rates for the DePuy ASR hip implants. Withdrawal of DePuy ASR hip implants from Australian market (Dec 2009) 23

Regulatory Actions U.K. Medicines and Healthcare products Regulatory Agency April 2010 MHRA Alert Local and soft tissue reactions and revision surgery Recommendations regarding metal ion testing and crosssectional imaging May & Sept 2010 MHRA Alerts Patients implanted with DePuy ASR hip implants February 2012 MHRA Alert Revised recommendations regarding metal ion testing and cross-sectional imaging Specific recommendations for patients with large diameter total hip systems ( 36mm), standard THR systems, resurfacing systems and the ASR 24

Regulatory Actions Health Canada 25

Regulatory Actions - FDA April 2009 515(i) Call for Safety and Effectiveness Information FDA called for safety and effectiveness information on all Class III preamendment devices for which the classification process has not been finalized Applies to MoM THR systems Five orthopedic manufacturers submitted information recommending downclassification of MoM THR systems Proposed rule under review, NOT the subject of this panel meeting 26

Regulatory Actions - FDA Two MoM THR device recalls in US Zimmer Durom Total Hip System (July 2008) Inadequate instructions for use Device currently available to surgeons who complete surgeon training program DePuy ASR Total Hip System (August 2010) Higher than expected revision rates THR system no longer marketed in the US Resurfacing system never marketed in US 27

Regulatory Actions - FDA Sept 2010 FDA met with professional societies Feb 2011 FDA posted public health communication on its website May 2011 FDA issued 522 postmarket surveillance orders for MoM THR Systems 28

Goals for this Advisory Panel Meeting Review currently available data regarding MoM hip systems Open and transparent dialogue of issues Characterize any potential and real safety risks Generate scientifically based recommendations for the clinical and patient communities on how to best communicate and mitigate risks NOTE: This panel meeting is NOT intended to address specific regulatory issues regarding MoM systems including prior market entry data, regulatory decisions or classification. 29

Advisory Panel Meeting Overview Transparent dialogue between: Advisory Panel Members FDA International Regulatory Bodies Professional Societies Industry Scientific Experts Academia Consumer Groups Public 30

Advisory Panel Meeting Overview Scientific Sessions: MoM Device Mechanics and Failure Modes Soft Tissue Imaging of the Hip Metal Ion Testing Methodology Outcomes: Local and Systemic Complications International Consortium of Orthopaedic Registries (ICOR) Revision Outcomes Literature Review 31

Advisory Panel Meeting Goals Recommendations for patient follow-up (symptomatic and asymptomatic) Total hip replacement systems Resurfacing hip systems Discussion of patient risk factors to take into account when considering MoM Hip Systems as an option Recommendations for modifications to current product labeling 32