Similar documents
Grid Automation Products. MicroSCADA Pro for substation automation

Document ID. Cyber security for substation automation products and systems

Symphony Plus Cyber security for the power and water industries

Managing Relion IEDs Protection and control IED manager PCM600

Remote Monitoring and REC 501 Control Unit Product Guide

Waveguide Access Point WGA631. Product Guide

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

ABB North America. Substation Automation Systems Innovative solutions for reliable and optimized power delivery

DIGITAL CONTROL SYSTEM PRODUCT SOLUTIONS

RuggedCom Solutions for

IntesisBox Modbus Server Fidelio IP

MicroSCADA Pro. System Configuration. Configuration Manual

WISE-4000 Series. WISE IoT Wireless I/O Modules

Internet-Accessible Power Monitoring & Control Systems

Network Management System (NMS) FAQ

Electrical Network Management System

Lifecycle Service Tool. Operator's manual

Cisco SR 520-T1 Secure Router

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER

Voltage Regulator SPAU 341 C. Product Guide

R-Win. Smart Wireless Communication Management System

i-pcgrid Workshop 2015 Cyber Security for Substation Automation The Jagged Line between Utility and Vendors

GE DigitalEnergy. Integrated Substation Control System (iscs) IEC based Substation Automation Solutions

Communicate and view data from meters with one simple device

INTEGRATING SUBSTATION IT AND OT DEVICE ACCESS AND MANAGEMENT

Fundamentals of a Windows Server Infrastructure MOC 10967

MicroSCADA Pro SYS 600C 2.93 Product Guide

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Emerson Smart Firewall

WinCon Programmable Automation. Controller

The All-in-One, Intelligent NXC Controller

Disturbance Recoder SPCR 8C27. Product Guide

Technology Spotlight on Cellular Data Networking for SCADA system networks. Presented by Teamwork Solutions, Inc.

Protection and Substation Automation. Training Programmes

NEW. EVEN MORE data acquisition and test stand automation

How To Use Safety System Software (S3)

HMS Industrial Networks. Putting industrial applications on the cloud

QuickSpecs. Models. Features and benefits Configuration. HP VCX x3250m2 IP Telecommuting Module. HP VCX x3250m2 IP Telecommuting Module Overview

Niagara IT Manager s Guide

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

WP WinPAC-8x49 Series (WP-8149/8449/8849) is the new generation WinCE based InduSoft PAC (Programmable Automation Controller).

4-CH Hybrid Digital Video Recorder

TAC XentaTM 555 Embedded Web Server for MicroNet

interoperability flexibility scalability Helvar Router Systems P e o p l e I n n o v a t i o n s S o l u t i o n s

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

How To Understand The Architecture Of An Ulteo Virtual Desktop Server Farm

1. Communication Network Requirements

CYBER SECURITY: SYSTEM SERVICES FOR THE SAFEGUARD OF DIGITAL SUBSTATION AUTOMATION SYSTEMS. Massimo Petrini (*), Emiliano Casale TERNA S.p.A.

Automation Unit TM 1703 ACP Flexible automation and telecontrol

securityprobe 5E Standard

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

Kevin Kochirka, ABB Turbine Automation, June 29, Flexible turbine control retrofits Webinar

MM8000 safety and security with smart danger management. A scalable and flexible management station for any requirement. Answers for infrastructure.

Network Management Card. User Manual

MNS is Switchgear System Technical Overview

You were seeking a protocol translator. Eaton delivered a vital data flow processor.

RUGGEDCOM CROSSBOW. Secure Access Management Solution. siemens.com/ruggedcom. Edition 10/2014. Brochure

ATM Video Surveillance

Grid Automation Products. MicroSCADA Pro for network control and distribution management

Tracer Summit Web Server

Square D Model 6 Motor Control Centers

SCADA Questions and Answers

Semaphore T BOX Applications in Data Center Facilities

Building Secure Networks for the Industrial World

SICAM PAS - the Key to Success Power Automation compliant with IEC and your existing system

Power Xpert Gateway 800E

1MRK GEN June 2016 Integrated Engineering Tool IET600 Ver. 5.3 FP2 Release Note

AutoLog ControlMan. Remote Monitoring & Controlling Service

The All-in-One, Intelligent WLAN Controller

securityprobe5es -X20

Instructions for transferring the SINUMERIK HMI to an external screen

FOXBORO. I/A Series SOFTWARE Product Specifications. I/A Series Intelligent SCADA SCADA Platform PSS 21S-2M1 B3 OVERVIEW

Substation Automation Systems. Nicholas Honeth

scalable data centre energy management solution

Communication Unit 560CMU05 Data sheet

Security appliances with integrated switch- Even more secure and more cost effective

Cisco TelePresence Video Communication Server Starter Pack Express Bundle

Client-Server SCADA Technology

Professional Integrated SSL-VPN Appliance for Small and Medium-sized businesses

Compatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

Gallagher Vapour Recovery Monitoring

Wireless Controller DWC-1000

3G Wireless-N Smart Energy Gateway

CISCO SPA3102 PHONE ADAPTER WITH ROUTER

EtherDevice Switch EDS-726 Series

HMS Industrial Networks

THE TOWN OF GROTON IS REQUESTING PROPOSALS FOR A WIRELESS ALARM MONITORING AND CONTROL SYSTEM WITH INTERNET BASED DATA ACCESS

How To Use The Vacon 0 Machinery

Monitoring solar PV output

TX2123 RS485 TO ETHERNET ADAPTOR

AC1200 Multi-Function Concurrent Dual-Band Gigabit Wi-Fi Router

GE Measurement & Control. Cyber Security for NEI 08-09

3G Cellular RTU Solutions. Activate Your Remote Monitoring Application

A&E Specifications RoadRunner Video Surveillance Systems for School Transportation Applications

Cyber security measures in protection and control IEDs

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

straton Universal control and strong connections. embedded field bus controller soft-plc scada logic

EUROTHERM MASTER COMMUNICATIONS 5000 Series with Master Communications for unsurpassed access to process data everywhere

IT Security and OT Security. Understanding the Challenges

Transcription:

Station Automation Series COM600 Protection and control from ABB

Future-proof Concept: Extensive Substation System Integration and Interoperability The Station Automation Series COM600 is a dedicated system for providing interoperability between industrial or utility substation IEDs (Intelligent Electronic Devices) and local or higher-level systems, such as local operator interfaces or higherlevel Network Control Centres (NCC) or Distributed Control Systems (DCS). The series features gateway functionality supporting a variety of commonly used substation device communication protocols. The COM600 series comprises three products, the Control and Monitoring Unit COM605, the Communication Gateway COM610 and the Station Computer COM615. System range The Control and Monitoring Unit COM605 offers web server functionality, providing a human machine interface (HMI) for local substation monitoring and control. COM605 is mainly used in applications requiring basic-level local and/or remote access using web technology. Secure communication enables the access of the substation HMI over the internet or LAN/WAN for any authorized user with a standard PC and a web browser. By connecting a laptop computer to the unit locally, an HMI for full monitoring and control functionality is obtained on the substation level. The Communication Gateway COM610 maps signals and data between the protection and control IEDs in industrial or utility substations and higher-level systems. The gateway interfaces with any master system using de facto master protocols. The Substation Computer COM615 offers the combined features and functionality of the Control and Monitoring Unit COM605 and the Communication Gateway COM610. The Station Computer provides gateway functions for mapping data and signals between substation level equipment and higher-level systems. Further, the Station Computer COM615 offers HMI functionality to satisfy local and remote monitoring and control needs. The entire COM600 series is designed for smooth system integration and interoperability based on pre-configured solutions utilizing connectivity packages for ABB IEDs. The Station Automation Series COM600 with three products enhancing your system 02 1 2 3 Control and Monitoring Unit COM605 for local/remote control and monitoring of substation IEDs. Communication Gateway COM610 for interoperability between the bay level and the NCC level. Station Computer COM615 for full station automation functionality.

COM615 COM610 COM605 Station Communication Station Communication NCC Communication Control and Monitoring External OPC client access Parameter settings & DR upload Remote parameter setting & DR upload Local HMI LAN/WAN/Internet/Intranet Station Automation COM600 concept Industrial Embedded Computer Advantages Open access to real-time information The COM600 products incorporate OPC Server functionality, which provides one entry point to all the information of a substation, and the IEC 61850 support enables connectivity and seamless communication with application-specific equipment. Full IEC 61850 compliance The COM600 series products are fully compliant with the IEC 61850 standard for distribution automation. Thus they provide full interoperability with any IEC 61850 compliant IEDs, tools and systems, which simplifies system design and commissioning. Fast commissioning of ABB IEDs The commissioning of ABB IEDs is straight forward due to the support of ABB's unique connectivity package concept, which simplifies system configuration and reduces the risk of errors in the system integration, minimizing device configuration and set-up times. Features Comprehensive supervision The COM600 series products can easily be monitored either using the dedicated Communication Engineering Tool (CET) or a web browser. The CET tool enables the process data flow to be viewed through COM600, thus reducing the need for additional protocol analyzers. Embedded technology With their compact and robust design, the COM600 series products are well adapted for harsh environments. They meet the IP4x degree of protection by enclosure and contain no moving parts subject to wear and tear. The COM600 series products are based on embedded technology for durability and maximum availability. Efficient protocol mapping The Communication Engineering Tool (CET) is an efficient instrument for creating protocol mappings. Based on the IEC 61850-7 model, cross-referencing between protocols is unified and simplified. The drag-and-drop signal mapping enables complete structures to be mapped from the source data. Configuration workflow of a COM600 device. Create the Project Transfer configuration data from IEDs Configure your HMI and/or Gateway Upload your configuration Commission your application 03

Secure Web Technology for Safe Communication User management & information security Information security is an issue of growing importance today. With its built-in security features for confidentiality, integrity, authentication, authorization, and auditing, the COM600 series addresses this issue. All COM600 products feature an integrated firewall on the dedicated WAN port to stop external unauthorized connection attempts. User accounts and access rights can be defined for both the COM600 software and the HMI, and are protected with individual passwords. Every user login/logout event is recorded. Connections from the web are to ensure confidentiality, integrity, and the authenticity of your remote monitoring and control data when data are transmitted over public networks. The operating system and applications are hardened and tested to withstand threats like worms or viruses from a public network. With their security features, COM600 products can defend themselves. For usage scenarios with higher security assurance requirements, they can also act as part of a defense-in-depth information security architecture involving an external firewall, intrusion detection systems, etc, to support your enterprise security policy. 04

Remote communication NCC/DCS Internet/ LAN/WAN Remote access COM615 User case COM615. Diagnostics Station communication Local HMI I/O device Station Computer COM615 COM600 features Ÿ Substation control Ÿ Busbar mimic diagram Ÿ Busbar colouring Ÿ Alarms and events Ÿ User-definable web links Ÿ Measuring and metering Ÿ Disturbance record upload Ÿ Parameter setting Ÿ System diagnostics Ÿ User management Ÿ Local language support Ÿ MS IE web interface Ÿ Security and authentication The Station Computer COM615 combines the features and functionality of the Control and Monitoring Unit COM605 and the Communication Gateway COM610. Full station automation functionality COM615 provides gateway functions for mapping signals between protection and control IEDs in industrial or utility substations and higher-level systems, and an HMI (Human Machine Interface) that provides an interface for data and information between the substation and the users. COM615 gathers the data from protection and control IEDs as well as process devices using different communication protocols. Control and monitoring data are displayed to different users in a well-arranged and user-friendly manner utilizing standardized web technology and transferred to the Network Control Centre or Distributed Control System. The Station Computer COM615 transfers information between the protection, control and automation equipment of a substation and a higher-level system by providing interoperability between different systems using different standard protocols. CET tool of COM615. 05

Remote access Internet/ LAN/WAN Remote communication NCC/DCS COM610 Diagnostics Station communication I/O device Communication Gateway COM610 COM610 is a communication gateway that maps signals between the protection and control IEDs and process devices in industrial or utility substations and higherlevel systems such as Network Control Centres or Distributed Control Systems. Extended gateway functionality The Communication Gateway COM610 sends process control and monitoring information to the NCC and DCS and receives process control commands from them. The gateway also handles system coordination tasks, such as dynamic assignment of control command authorisation and communication supervision. COM610 is typically connected to an NCC via a telecontrol protocol, or to a DCS using the OPC Server/Client technology. Various protocols can be used to connect process devices to the communication gateway. COM610 is a true IEC 61850 gateway supporting all applicable IEC 61850 parts. The integrated system diagnostics functions provide accurate information on the operation of every network component. The detailed diagnostic information facilitates commissioning work and shortens the overall delivery time of the project. The system diagnostics functions also enhance fault location and clearance capabilities. Example of communication diagnostic view of COM610. 06

Internet/ LAN/WAN Remote access COM605 Local HMI Station communication I/O device Control and Monitoring Unit COM605 COM605 is a control and monitoring unit allowing a stand-alone HMI to be used for data and information from the substation. The Control and Monitoring Unit COM605 gathers data from protection and control IEDs and process devices using different protocols. COM605 uses web technology to display data in a professional and userfriendly manner. It includes a web server, which can provide the HMI on a monitor connected either directly to the unit or to any web client, when COM605 is connected to the intranet/internet over LAN/WLAN/WAN networks. Total control and monitoring of your substation The COM605 user interface offers easy access to essential information in your substation. A single-line diagram with busbar colouring based on the actual network status gives you a quick overview of the situation and the switching state of your substation. Status data is updated in real time and the single-line diagram is re-coloured accordingly. Intuitive control dialogs guide you through the control commands in a safe, select-before-execute manner. To facilitate information access, web links to any reference documentation can be added to the control dialogs, e.g. functional descriptions and maintenance information. Easy-to-read, clear and well-organized alarms and events are always just a mouseclick away. Lists are updated in real time but can be frozen, when needed. Filtering can be applied to sort the information you need, and alarms are coloured and classified by their current status. Naturally, you can acknowledge single, multiple or all alarms. The event lists can be exported to Microsoft Excel. The user interface also includes a contextsensitive on-line help function which guides the operator and provides specific information on demand. Single-line diagram of COM605. 07

Station Automation Series COM600 COM615 COM610 COM605 Connectivity: Master protocols: IEC 61850-8-1 client IEC 60870-5-103 Modbus (serial and TCP) LON (according to the ABB Lon Application Guideline LAG) SPA DNP 3.0 Slave protocols: IEC 60870-5-101 IEC 60870-5-104 DNP 3.0 Serial & LAN/WAN SPA Router OPC DA and A&E for external OPC clients IEC 62439/PRP (Parallell Redundancy Protocol)* Switch Fault Tolerance (SFT)* SNTP server for local time synchronization for IEC 61850-8-1 client Support for remote parameter setting and disturbance file upload with ABB protection and control devices from MicroSCADA Pro Connectivity to ABB s Low Voltage Motor Control Center MNS is HMI functions System supervision and communication diagnostics Single-line diagram with busbar colouring Switch device control Event and alarm lists Measurement display Individual user accounts with role-based access control and access event logging User-definable web links Parameter setting for ABB protection and control IEDs which are connected with SPA, LON or IEC 61850 (mainly distribution level) and supporting SPA parameters Disturbance data upload for IEC 61850 devices HMI through web server functionality using Internet Explorer with Adobe SVG viewer 3.03 * Requires the LAN option card Hardware: Industrial computer with no moving parts Communication ports: 2 x LAN (RJ-45 copper), 4 x RS-232 (one of which can be configured as RS-485; 2-wire) Other ports: VGA output, 4 x USB, audio output for audio alarm Optional cards: RS-232/RS-485 (8 ports) or LAN (2 ports, RJ-45 copper) or LON (1 port) Power supply: 76-240 VDC/internal Operation temperature range: -25...+70 C Environmental conditions: Humidity 5-95% at +40 C, non-condensing Dimensions: 214 mm (W) x 122.5 mm (H) x 313 mm (D) 1MRS755810 E 6/2008 Copyright 2008 ABB. All rights reserved. Tested according to: CE marking, Vibration and shock, EMC Class B Security: Built-in firewall Secured, encrypted communication for web clients (https) Hardened and locked-down local operating system The information in this document is subject to change without notice and should not be construed as a commitment by ABB Oy. ABB Oy Distribution Automation P.O. Box 699 FI-65101 VAASA, Finland Phone: +358 10 22 11 Fax: +358 10 22 41094 www.abb.com/substationautomation ABB Inc Distribution Automation 655 Century Point Lake Mary, FL 32746 Phone: + 1 407 732 2000 Fax: + 1 407 732 2335 www.abb.com/substationautomation