Super Slider ADJUSTABLE FROM 3.5-12 Model #HD26229

Similar documents
VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249

Horizontal Lifeline. SideWalk Rope. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

D-Ring. Fixed Arm. 1.2 LIMITATIONS: The following application limitations must be recognized and considered before using this product:

Operating instructions. 3-in. x 6-ft. Anchor Strap for Skyline Horizontal Lifeline

Operations and Instruction Manual Might Swivel - Part # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn

Product Name: Beamer 2000

User Instruction Manual Vertical Lifelines and Vertical Lifeline Subsystems

Wire Rope Extender Lanyard

Lanyards. Self Retracting. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

Safe Operating Procedure

RZ Guardrail System Installation Manual

fall arrest. Contact your distributor or Guardian about policies regarding replacement of Guardian components involved in a fall.

Fall Protection Guidelines

WORKING AT HEIGHT & ITS WOES

Fall Protection Program

Elkhorn Construction, Inc. Safety Manual Title: Fall Protection Policy Effective Date:

Working at Heights and Fall Protection

Temporary Horizontal Lifeline System Manual Standard Duty - E8 Model: HLLA38030 and HLLA38060

Fall Protection and Fall Prevention. San José State University Environmental Health and Safety Facilities Development & Operations

Personal Energy Absorbers Absorbing Lanyards

ELEVATED WORK POLICY

FALL PROTECTION WORK PLAN

Fall Protection System: A system put in place to protect workers from falling. (i.e. installation of guardrails, fall arrest, fall restraint, etc.

Introduction to Fall Protection

EMPLOYEE FALL PROTECTION

Frequently Addressed Topics in Fall Protection

ATS Overhead Table Shelf System INSTRUCTION MANUAL

OSHA 29 CFR 1926 Subpart M ( ) OSHA 29 CFR 1910 Subparts D,F, I ( , 66, 67, and 132

Installation, Operation & Maintenance Manual for Rigid Lifelines , , , and Series Self-Retracting Lanyards

FALL PROTECTION- Part 2 SELF INSPECTION CHECKLIST

1 Ton Telescoping Gantry Crane

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Owner s Manual & Safety Instructions

ROTOR LOADER OWNER S MANUAL

OSHA Remove impacted systems and components. Inspect systems prior to use.

Fall Protection Safety Program

Table of Contents WARNING SYMBOLS AND DEFINITIONS

Figure Figure 2 - Applications

Instructions for the following series products:

758 Heavy-duty Ratchet Guy Wire Cutter

Destiny Shower Enclosure Installation Instructions

Fabric Replacement Top Installation Instructions

Owner s Manual & Safety Instructions

TREE SPIDER TREE STRAP Models: TSTS, TSTS3PK

Sample Fall Protection Program

How To Make A Fall Arrest Anchor System

PALLET JACK TON

INSTRUCTION BOOK FOR. Dual Monitor Video Conferencing Cart

Fall Protection Susan Harwood Grant Training Program 2013 Fall Arrest. OSHA Susan Harwood Training - AGC

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Fall Protection and Prevention Training Construction & Safety Professionals

`Fall Protection Guidelines in Construction

INSTRUCTION BOOK FOR. Single Monitor Video Conference Cart

Frequently Asked Questions

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

Working at Heights. Understanding the Requirements of Fall Protection. 29 CFR 1926 Subpart M Fall Protection

ELECTRICAL SAFETY & ARC FLASH Handbook

Department of Environmental Health & Safety. Fall Protection Program

Chapter 10 - Scaffolding Systems

Owner s Manual Gantry Cranes

RESCUE PLAN FALL PROTECTION PROGRAM

CHECKLIST Fall Protection

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

Fall Protection. Solutions for Safety at Heights. Risk Assessment. Hierarchy of fall protection options. Supplementary Administration Controls

SITE SPECIFIC FALL PROTECTION PLAN

It should be noted that this revised standard does not address the construction industry, window cleaning belts, and sports-related activities.

RT-200 HI-TEST ROPE TESTER

About this Manual. Support for Your Product

Owner s Manual & Safety Instructions

FALL PROTECTION PROGRAM

Fall Protection Equipment

USER INSTRUCTIONS. MSA HORIZON Horizontal Lifeline Anchorage Connecting Subsystem

NFC Communication Tray Model: HHX-IT3-Z

PART 17 SAFETY/RESCUE HARNESS JACKET TYPE M 500/1 BRIGADE ORDER TECHNICAL NO. 13 C O N T E N T S. Page No PURPOSE STRATEGIC AIMS AND OBJECTIVES

Assembly Instructions

Health and Safety Resources Caution to Users

Cardio-Tramp REBOUNDER MANUAL. Please review this important information regarding your STOTT PILATES

Fall Protection, Title 29 Code of Federal Regulations (CFR) Part 45, Subpart M, Fall Protection, , , , and1926.

Hydraulic Transmission Jacks Operating Instructions & Parts Manual

Installation Instructions

Installation Guide Smart-UPS X External Battery Pack SMX120BP

CR-SERIES CARPET POLES INSTRUCTION MANUAL

Horizontal Cable Systems

Mounting Details - Footpads & Brackets

Calvert USA, Inc. Attic Stairs

Fall Protection Safe Work Plan Fall Distance of 7.5M or More

2-Way Wireless Indoor Siren Installation Guide

PATHWAY Classic Series with Handrails Portable Wheelchair Ramp INSTRUCTIONS FOR USE 6428 REV A

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Walking and Working Surface Checklist:

The Work at Height Safety Association. Guidance on inspecting eyebolts used for personal fall protection purposes

Installation Instructions / Warranty

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

MALONER. Installation & Loading Instructions - Please Read Before Beginning. Step 1: Installing Carriers to Cross Bars

TBM5, TBM5-S and TBM5-SV

Say Hello to Your Precision Cooker

By SP Partners, LLC. INSTALLATION GUIDE. Prestige

Introduction to Fall Protection. The University of Tennessee Office of Environmental Health & Safety

Transcription:

Super Slider ADJUSTABLE FROM 3.5-12 Model #HD26229 IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS SHOULD BE FAMILIAR WITH PERTINENT REGULATIONS GOVERNING THIS EQUIPMENT. ALL INDIVIDUALS WHO USE THIS PRODUCT MUST BE PROPERLY INSTRUCTED ON HOW TO USE THIS DEVICE. V3-0416

Read This Instruction Manual Carefully Before Using This Equipment. User Instructions must always be available to the user and are not to be removed except by the user of this equipment. For proper use, see supervisor, User Instructions, or contact the manufacturer. Compliant fall protection and emergency rescue systems help prevent serious injury during fall arrest. Users and purchasers of this equipment must read and understand the User Instructions provided for correct use and care of this product. All users of this equipment must understand the instructions, operation, limitations and consequences of improper use of this equipment and be properly trained prior to use per OSHA 29 CFR 1910.66 and 1926.503 or applicable local standards. Misuse or failure to follow warnings and instructions may result in serious personal injury or death. PURPOSE The HD26229 is an anchorage connector designed to function as an interface between the anchorage and a fall protection, work positioning, rope access, or rescue system for the purpose of coupling the system to the anchorage. Any references to anchorage connector in this manual include, and apply to, the HD26229. USE INSTRUCTIONS 1. A user must be of sound mind and body to properly and safely use this equipment in normal and emergency situations. Users must have a physician ensure they are clear of any medical conditions that may affect the proper and safe use of this equipment in normal and emergency situations. 2. Before using a personal fall arrest system, user must be trained in accordance with the requirements of OSHA 29 CFR 1910.66 in the safe use of the system and its components. 3. Use only with ANSI/OSHA compliant personal fall arrest or restraint systems. The anchorage must have the strength capable of supporting a static load, applied in the directions permitted by the system, of at least 5,000-lbf (22kN) in the absence of certification. 4. The user shall be equipped with a means of limiting the maximum dynamic forces exerted on the user during the arrest of a fall to a maximum of 8 kn (1800-lbf). 5. Use of this product must be approved by an engineer or other qualified person to be compatible with any and all structural & operational characteristics of the selected installation location and system to be connected to this anchorage connector. 6. The anchorage connector must be inspected prior to each use for wear, damage, and other deterioration. If defective components are found the anchorage connector must be immediately removed from service in accordance with the requirements of OSHA 29 CFR 1910.66 and 1926.502. 7. The anchorage connector should be positioned in such a way that minimizes the potential for falls and the potential fall distance during use. The complete fall protection system must be planned (including all components, calculating fall clearance, and swing fall) before using. 8. A rescue plan, and the means at hand to implement it, must be in place that provides the prompt rescue of users in the event of a fall, or assures that users are able to rescue themselves. 9. After a fall occurs, the anchorage connector must be removed from service and destroyed immediately. USE LIMITATIONS: The anchorage connector shall not be used outside its limitations, or for any purpose other than that for which it is intended. 1. The anchorage connector is designed for single user, with a capacity up to 310 lbs (140 kg) including clothing, tools, etc. 2. The anchorage connector may only be loaded as shown in the LOADING CONDITIONS DIAGRAM. 3. The anchorage connector is designed to be used in temperatures ranging from -40ºF to +130ºF (-40 C to +54 C). 4. Do not expose the anchorage connector to chemicals or harsh solutions which may have a harmful effect. 5. Do not alter or modify this product in anyway. 6. Caution must be taken when using any component of a fall protection, work positioning, rope access, or rescue system near moving machinery, electrical hazards, sharp edges, or abrasive surfaces, as contact may cause equipment failure, personal injury, or death. 7. Do not use/install equipment without proper training by a competent person as defined by OSHA 29 CFR 1926.32(f). 8. Do not remove the labeling from this product. 9. Additional requirements and limitations may apply depending on anchorage type and fastening option utilized for installation. All placements must be approved by an engineer or other qualified person. 10. This anchorage connector should not be used as part of a horizontal lifeline system that has not been designed and or approved to be used with 5,000-lbf anchorage connectors. 11. The anchorage connector should only be used for personal fall protection and not for lifting equipment. COMPATIBILITY LIMITATIONS Anchorage connector must only be coupled to compatible connectors. OSHA 29 CFR 1926.502 prohibits snaphooks from being engaged to certain objects unless two requirements are met: it must be a locking type snaphook, and it must be designed for making such a connection. Designed for means that the manufacturer of the snaphook specifically designed the snaphook to be used to connect to the equipment listed. The following connections must be avoided, because they can result in rollout* when a nonlocking snaphook is used: Direct connection of a snaphook to horizontal lifeline. Two (or more) snaphooks connected to one D-ring. Two snaphooks connected to each other. A snaphook connected back on its integral lanyard. A snaphook connected to a webbing loop or webbing lanyard. Improper dimensions of the D-ring, rebar, or other connection point in relation to the snaphook dimensions that would allow the snaphook keeper to be depressed by a turning motion of the snaphook. *Rollout: A process by which a snaphook or carabiner unintentionally disengages from another connector or object to which it is coupled. (ANSI Z359.0-2007)

PERFORMANCE: Static Tensile Strength: 5000-lbf (22kN) Maximum Capacity: One worker with max weight of 310-lbs when used as a single point anchorage connector for personal fall arrest or restraint system DIMENSIONS: Weight: 3.4-lbs Beam Flange Width Range: 3.5-12 Beam Flange Thickness:.25 to 1.25 REGULATORY COMPLIANCE: ANSI Z359.1(07), ANSI Z359.7(11), OSHA 1926.502, OSHA 1910.66, EN 795:2012 Class B COMPONENT MATERIALS: Aluminum: Cross Bar, Clamps Bronze: Flange Insert Stainless Steel: D-Ring Bracket Zinc Plated Steel: D-Ring, Spring, Hardware (Notches) (Notches) (Latch Handle) (Adjustable Hook) (Adjustable Hook) (Latch Handle) (D-Ring Swivel) (Retaining Bushing) Installation: 1. Locate a structural steel beam flange capable of withstanding a 5,000-lbf. static load or meeting OSHA 1926.502 requirements for a safety factor of two. 2. Push in on the latch handle to allow the adjustable hook to move. 3. Keeping the unit perpendicular to the beam, fit the hooks over the edges of the beam flange. 4. Slide the adjustable hook so that both hooks are snug against the beam flange. 5. Pull back the adjustable hook to ensure the ratchet teeth are fully seated in the nearest ratchet notches. 6. Tug, rock, and twist the anchor in all directions to ensure that it cannot come off of the flange. Always re-adjust according to steps 1-6, above when moving to a new or different size beam.

LOADING CONDITIONS DIAGRAM Placement at or below a user s working height requires integration of a compatible ANSI Z359.1 shock-absorbing lanyard that does not allow the user to extend more than 6 feet (in any direction) from the anchorage connector before the shock absorber is activated. The beam anchor must be attached to the I-beam flange facing the user (top flange if above, bottom flange if below, etc.).

The user shall be equipped with a means of limiting the maximum dynamic forces exerted on the user during the arrest of a fall to a maximum of 8 kn (1800-lbf). (ANCHOR POINT) WORK SURFACE WARNING! Swing falls may occur when the worker is not directly under anchor point. Inspect retaining bushing for wear or damage. WORK SURFACE All products subjected to fall arresting forces should be removed from service immediately. MINIMUM CLEARANCE 3ft (1m) DECK/FLOOR/GROUND LEVEL

WARNING LABEL LOCATIONS WARNING: It is essential to the safety of the end user that the seller of this device include all instructions pertaining to the proper use, maintenance and inspection of the device in the language of the country in which the product is to be sold.

MAINTENANCE, CLEANING AND STORAGE Cleaning periodically will prolong the life and proper functioning of the product. The frequency of cleaning should be determined by inspection and by severity of the environment. Clean with compressed air and/or a stiff brush using plain water or a mild soap and water solution. Do not use any corrosive chemicals that could damage the product. Wipe all surfaces with a clean, dry cloth and hang to dry, or use compressed air. When not in use, store anchorage connectors in a cool, dry, clean environment, out of direct sunlight and free of corrosive or other degrading elements. INSPECTION AND MAINTENANCE LOG MODEL NUMBER: DATE OF MANUFACTURE: Date Part Number Comments Inspector Name Inspection: Official periodic inspection must be made at least annually. The inspection must be performed by a qualified person other than the intended user. If severe weather or conditions exist then inspections must be carried out more frequently. All inspection results must be logged in the space provided above. (It is recommended that the anchor device is marked with the date of the next or last inspection.) 1. Make sure all labeling is affixed to the unit. 2. Inspect anchoring system for signs of damage or wear. 3. Make sure the ring is free to swivel and pivot. 4. Check for excessive play and wear on the retaining bushing (Bushing should not wiggle or rotate). 5. Ensure latches engage and disengage properly. 6. Record inspection results in the space provided above. If any damage that could affect the strength or operation of the device, or unsafe conditions are found, proper disposal is required. The anchorage connector must be rendered unusable and then properly discarded.

Product Warranty, Limited Remedy and Limitation of Liability WARRANTY: THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. PMI LIMITED WARRANTY PMI products are warranted to the original retail purchaser to be free from defect in material and workmanship for a period of one year. PMI will repair or replace the item without charge provided inspection at our factory discloses no misuse or alteration, which, in our judgment, has affected the condition or functioning of the product. All implied warranties imposed by law in connection with the sale of PMI products are also limited in duration to a period of one year. PMI expressly excludes and shall not be liable for any consequential damages arising out of any breach of the express or implied warranties on sales of PMI products. Because of the high risks involved in high angle rope work such as, but not limited to, rescue, rope access, caving, rappelling, rock climbing and mountaineering, no further warranties exist or are implied by PMI. Regulations issued under the Magnuson-Moss Warranty Act require us to include the following statement: some states do not allow limitations on how long an implied warranty lasts nor the excluding or limitation of incidental or consequential damages, so the above limitations may not apply to you. LIMITATION OF LIABILITY: IN NO EVENT WILL PIGEON MOUNTAIN INDUSTRIES BE LIABLE FOR ANY INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING, BUT NOT LIMITED TO LOSS OF PROFITS, IN ANY WAY RELATED TO THE PRODUCTS REGARDLESS OF THE LEGAL THEORY ASSERTED. Pigeon Mountain Industries PO Box 803 LaFayette, GA 30728-0803 800-282-ROPE (7673) / www.pmirope.com