LABELLING OF GAS BOILERS - AN EFFICIENT MARKET REGULATOR



From this document you will learn the answers to the following questions:

What is the main consideration in the energy label?

What was the aim of the scheme to give the consumer a easy to use and fair tool for choosing a new domestic gas boiler?

What does the new energy labelling scheme as a tool for choosing the right gas boiler?

Similar documents
EcoDesign & Labelling Directive (ErP)

The new Ecodesign regulation for heaters: what does it mean for heat pumps?

ErP made easy! Valves, controls + systems. Guideline Individual packages according to ErP with high energy efficiency and a good benefit/cost ratio

Hybrid heat pumps. saving energy and reducing carbon emissions

ROTEX gas hybrid heat pump. A strong team.

ErP made easy What does it mean to merchants? What does it mean to installers?

Daikin Altherma. hybrid heat pump. The natural combination

How To Comply With The Erp Directive For Ground Source Heat Pumps

Demonstration projects regarding Gas hybrid and Booster heat pumps. IEA Workshop Aarhus 4 May 2015 Svend Pedersen

Daikin Altherma Hybrid Heat Pump

Half the cost Half the carbon

The natural ombination

The natural ombination

Continuous flow direct water heating for potable hot water

Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings

NIBE INSTALLER GUIDE TO ErP, SIMPLE AS 1 2 3

Daikin Altherma Hybrid Heat Pump

Training in Renewable Energy INFORSE-Europe proposal for implementation of the Renewable Energy Directive Draft 28/

Daikin Altherma hybrid heat pump. The natural combination

ROTEX Gas-Hybrid-Heat Pump

Ecodan Air Source Heat Pump and Flow Temperature Controller 2

CHP Plant based on a Hybrid Biomass and Solar System of the Next Generation EU project No. ENER/FP7/249800/"SUNSTORE 4" Dipl.-Ing. Alfred Hammerschmid

Danish-German Energy Efficiency Summit. Cost effective policy instruments Obligations on Energy Companies

Hot Water Heating: Technologies and Use

Natural geothermal energy.

Daikin Altherma Hybrid Heat Pump

ATMOSPHERIC EMISSIONS FROM GAS FIRED HOME HEATING APPLIANCES

REPORT. Hybrid heating systems and smart grid. System design and operation market status. Project report April 2013

THE EUROPEAN GREEN BUILDING PROGRAMME. Technical Module on Combined Heat and Power

Home comfort: water heating

Gas Absorption Heat Pumps. Future proofing your heating and hot water

Vitocaldens 222-F Compact Gas-Hybrid appliance

newenergylabel.eu The new European energy label: the success story continues

Your guide to registering with OFTEC. Guide to registration

Theta Dual service BFC, SGE, SGS for 20/30/40 kw heating capacity

High-efficient gas boiler CompactGas

HIGH-EFFICIENCY CO 2 HEAT PUMP WATER HEATER SYSTEMS FOR RESIDENTIAL AND NON-RESIDENTIAL BUILDINGS

COUNCIL DIRECTIVE 92/42/EEC of 21 May 1992 on efficiency requirements for new hot-water boilers fired with liquid or gaseous fuels

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Combi Unit Genius. The energy efficient Building Service Centre

Create the right atmosphere with renewables.

Energy Efficiency trends and policies

European actions to improve the energy efficiency of buildings. Olli Seppänen, professor Federation of European Heating and Airconditioning

FREQUENTLY ASKED QUESTIONS (SOLAR WATER HEATER)

Energy consumption and heat recovery of refrigeration system in modern Arena

Quantifying the energy and carbon effects of water saving summary report

MONITORING SCHOOL ENERGY CONSUMPTION

school energy consumption assessment

Domestic Heating Energy Savings with Better Controls

Heat Pumps for Domestic Hot Water Preparation in Connection with Low Temperature District Heating

Get more from your hot water

SOLAR THERMAL SYSTEMS FOR DOMESTIC HOT WATER AND SPACE HEATING UELI FREI, PETER VOGELSANGER

Condensing Boiler Efficiency

LG Electronics AE Company, Commercial Air Conditioning

BoilerMate SP. benchmark. user instructions A - C L A S S

Improving thermal insulation of concrete sandwich panel buildings

User's Instructions. Alpha HE CB25/33 and HE SY25

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

District Heating & Cooling

Program Overview. Free intelligent thermostat and gateway device ($150 - $200 value)

Kiwa s ErP Newsletter

FIRST ANNOUNCEMENT AND CALL FOR ABSTRACTS. 7th International Conference on Energy Efficiency in Domestic Appliances and Lighting (EEDAL 13)

Monitoring your Energy Bills in Your Business

Session 2: Hot Water Supply

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump

Boiler efficiency for community heating in SAP

Carbon Dioxide Emission Savings Potential of Household Water Use Reduction in the UK

We carried out the comparative. Split Air Conditioners. More efficiency for the energy. Comparative Test

Air-to-water heat pumps: Making the most of renewables. Richard Pickford, Daikin UK

GAS HEAT PUMPS WORKSHOP 01 st & 02 nd December 2011 Saint-Denis/Paris. Dr. Belal Dawoud. Viessmann Werke Allendorf GmbH Viessmann Strasse, 1

Typical condensing boilers can have an efficiency rating of 89% and up, which is 25% more efficient than a non-condensing boiler.

Heat Pumps in the Building Sector: Hybrid Heat Pumps opening UK retrofit opportunities?

2015 Summary of Connecticut Electric Rates Last Updated: July 1, 2015

Energy Audits. Good energy management begins with an energy audit

A simple way to go solar. And save on energy costs.

E-gas Instant Gas Water Heaters

Experience Our Innovation

Danish Energy Saving Report

GREEN EFFICIENT FRIENDLY SUSTAINABLE ENERGY: CERTIFICATED TRAINING

Summary technical description of the SUNSTORE 4 plant in Marstal

Field test of a novel combined solar thermal and heat pump system with an ice store

Measurement of Domestic Hot Water Consumption in Dwellings

New technical solutions for energy efficient buildings

Transcription:

23rd World Gas Conference, Amsterdam 2006 LABELLING OF GAS BOILERS - AN EFFICIENT MARKET REGULATOR Main author Karsten V. Frederiksen DENMARK Corresponding authors J. Schweitzer, L. van Gruijthuijsen, B. Spiegelhauer DENMARK

Abstract This paper presents a new energy labelling scheme as a tool for choosing the right gas boiler. The impact on the boiler market after a pilot period using the scheme in Denmark is discussed. Analyses have been made concerning: - Development of an easy-to-use and objective evaluation tool. - The boiler manufacturers way of implementing the labelling system. - Change in the configuration of the boilers (related to energy consumption). - Development in the market of the best A labelled boilers compared to other boilers. - The role of the gas companies in the process. - Collaboration in the EU concerning a common EU label. TABLE OF CONTENTS 1. Abstract 2. Background 3. Aims of the label 4. Basis for evaluation 5. The present situation after a one-year pilot period 6. Conclusions 7. References 8. List of Tables 9. List of Figures

2. BACKGROUND An energy labelling scheme for electrical appliances (based on an EU directive) has been used in EU for more than 10 years and has been a successful tool to promote efficient appliances on the market. As no similar label was available for gas appliances, the Danish gas companies and Danish Gas Technology Centre decided to launch a similar voluntary labelling scheme for domestic gas boilers based on the same well-know existing design. 3. AIMS OF THE LABEL The aim of the work was to give the consumer an easy-to-use and fair tool for choosing a new domestic gas boiler and thus to promote the use of high-efficient boilers. To that end we have tried to get the support from the entire gas industry in Denmark and EU. As the boilers on the Danish market are also available on other EU markets there is a wide interest for collaboration, which to a very large extent depends on the broad support of all parties concerned. 5. BASIS FOR EVALUATION The annual efficiency (BOILSIM calculation method /1/) is the basis for the boiler labelling scheme. The advantage of this choice is that the method was developed under the European research programme (SAVE) by laboratories and manufacturers. Therefore, it is considered by many as the standard for determination of boiler annual efficiency by a large number of EU test laboratories. Calculation algorithms for determination of an energy label for domestic gas boilers were developed. These algorithms included the parameters chosen for evaluation and the criteria set up for graduation of the boilers. It proved very helpful for the support of the boiler manufacturers that the design was following the standard from the dir. 92/75. The arrow label graduated from A-G and with key figures with comparable information on energy utilization and environmental load of the individual boilers is meant as a decision tool for the consumer. To further assist the consumer in achieving a high sanitary hot water comfort and energy optimized operation of the heating system guidelines for choosing the best boiler/hot water tank combination were developed. Storage technology is the main market for sanitary hot water production. Figure 1 shows the template of the design of the label.

Energy Label Model Logo Low consumption A B C Large consumption D Annual electricity consumption XYZ kwh Annual efficiency XYZ % Environmental load (NO x ) X (Y,Z kg/år) Choice of hot water tank E A Alternatives, hot water tanks Hot water need Hot water tank 1 (xx litre) Very large (15-18 litre per min.) Hot water tank 2 (xx litre) Large (12-15 litre per min.) Hot water tank 3 * (xx litre) Normal (9-12 litre per min.) Hot water tank 4 (xx litre) Small (6-9 litre per min.) *The boiler has been tested with a tank of xx litre. Choose a hot water tank to meet your need following the advice of your gas installer. Please note: If you choose a larger tank than the one tested, your annual energy consumption may turn out larger, and a smaller tank may lead to a lower consumption F G Prepared by DGC in collaboration with the natural gas companies and the Danish Energy Authority. For further information please contact your local gas company. Figure 1: The template of the design of the label

Below it is described in general terms how each value of the energy label is calculated. A detailed description of the calculation method for the energy label is found in the document Description of the calculation method for the Danish labelling of gas fired boilers that can be downloaded from DGC s homepage. Total annual energy consumption and the A-G label (Figure 1) The boiler is evaluated on the basis of the total energy consumption (gas and electricity) needed to produce 20,000 kwh heat + 2,000 kwh hot water. Electricity consumption is weighted with a factor of 2.75 and the gas consumption with a factor of 1 (the ratio corresponds to a gas price of 6 DKK/m3 and an electricity price of 1.5 DKK/kWh). (The accuracy of measurements of efficiency was carefully taken into account for the design of the label.) Weighted energy consumption [gas and electricity, kwh] Energy label < 23500 A 23500-24600 B 24600-25800 C 25800-27100 D 27100-28600 E 28600-30200 F > 30200 G Table 1: Criteria for energy labelling of boilers based on total energy consumption Heat production The annual efficiency of the boiler for heat production is calculated for an annual heat demand of 20,000 kwh. The calculation is based on an 8 kw heating installation, dimensioned for an average temperature on the water side of 55 C and ΔT = 15 C at an outdoor temperature of -12 C. It is assumed that the boiler runs at minimum load when the heat demand is smaller than the minimum load of the boiler. The calculation of heat production is made according to the BOILSIM method. Hot water Annual efficiency for production of hot water is calculated for an annual consumption of 2,000 kwh, corresponding to the average consumption of Danish single-family homes. Electricity consumption The electricity consumption is calculated for a house with an annual heat demand of 20,000 kwh and an annual hot water consumption of 2,000 kwh. The pump is assumed to run for the entire heating season = 220 days. Annual electricity consumption (Figure 1) As described above for Total annual energy consumption (section 1). Annual efficiency (Figure 1) As for the calculation of total energy consumption, the boiler annual efficiency is calculated on the basis of an annual energy consumption for producing 20,000 kwh heat + 2,000 kwh hot water. Environmental load (NO x ) (Figure 1) NO x emission is calculated for an annual consumption of 20,000 kwh heat + 2,000 kwh hot water, with pure methane (G20) as combustion gas.

The annual environmental load of NO x emission is graduated on a scale from A to G based on the criteria: - Annual NO x emission below 1 kg/year corresponds to A - Annual NO x emission between 1 and 2 kg/year corresponds to B - Annual NO x emission between 2 and 3 kg/year corresponds to C - Annual NO x emission between 3 and 4 kg/year corresponds to D - Annual NO x emission between 4 and 5 kg/year corresponds to E - Annual NO x emission between 5 and 6 kg/year corresponds to F - Annual NO x emission over 6 kg/year corresponds to G. Choice of hot water tank (Figure 1) The hot water demand that can be covered by boiler and hot water tank is determined on the basis of Figure 2. Figure 2: Criteria for choice of hot water tank Table 2 shows the definition of the number of taps. Litre per minute Hot water need for 10 minutes Corresponding to e.g. Small 6-9 Shower Normal 9-12 Shower and wash basin at the same time Large 12-15 Bath tub or two showers at the same time Very large 15-18 Two showers and wash basin at the same time Table 2: Definition of the different categories of hot water needs Upon adoption of the CEN standard EN 13203, the basis of calculation will be revised with the effect that the CEN standard will then form the basis of choice of hot water tank. Apart from the label, other tools were developed that explain the contents of the label and facilitate comparison of alternative boilers. Different tools were developed for the consumer and the

installer, respectively. Boiler manufacturers are yet another target group. Apart from the above advising tools the manufacturers need to know what they are required to do in order to have their new boilers included in the labelling system. To facilitate the implementation of the labelling scheme in the energy sector a large range of tools have been developed. The following tools are aimed to help the end-user choose the best boiler: - Boiler list - can be used for a quick comparison of the boilers. - Information sheet - gives a short explanation of the individual elements of the energy label. The following tools are aimed to help the installer, the energy adviser and the sales person to give advice concerning choice of the best boiler: - Boiler list - can be used for a quick comparison of the boilers. - Information sheet - gives a short explanation of the individual elements of the energy label. - Guideline - gives a detailed explanation of the contents of the energy label. - Presentation material - can be used for marketing. The following tools are aimed to help the boiler suppliers and the producers: - Administration document - describes the rules for the boiler manufacturers participating in the labelling system. - Procedure for boiler tests - in case the boiler manufacturer wants to provide the required documentation for labelling. - Description of calculation method - can be used by the manufacturer for determination of the energy label of the boiler. - Market surveillance document - describes actions to prevent abuse of the energy label. Together with the Danish gas companies and supported by the Danish Energy Agency as well as the boiler manufacturers, DGC has established a website for the boiler labelling list /2/ and an explanation in English /3/. This website also includes all the above tools. A secretariat and a steering group are in charge of administering the labelling system. 6. REPORT ON THE SITUATION AFTER A ONE-YEAR PILOT PERIOD The implementation of the labelling scheme in the market was based on a close cooperation between DGC and the gas companies, boiler industry, Danish Electricity Saving Trust, National Consumer Agency and Danish Energy Authority. They were all prepared to support the energy labelling scheme for domestic gas boilers. The most important success criterion is that these groups would in actual fact support and use the scheme in their activities, and as will appear from the below evaluation the intentions have indeed been transformed into action. Development of the boiler list From the start in August 2004 the list comprised 34 boilers, of which 49 % were A labelled. During year 1 additional 14 gas boilers were accepted in the energy labelling scheme. All 14 new boilers received the A label. So a total of 72 % of the boilers on the list were A labelled. All boiler manufacturers on the Danish market are represented on the boiler list, and the list is used by end users, installers and others who are about to compare and choose between alternative boilers. The key figures of the energy label show a distinct trend confirming the aim of the energy labelling scheme. We draw the attention to the below points: 1. After one year, the average annual efficiency for all boilers in the list was 96 %, constituting an increase of 2 percentage points on the starting point.

2. After one year, the average electricity consumption for all boilers on the list was 477 kwh/year, constituting a decrease of 5 % on the starting point. 3. After one year, the average NO x emission for all boilers was 1.1 kg/year against 1.3 kg/year at the start. Development of the market The fact that the boilers included in the labelling scheme are becoming better and better does not necessarily mean that they are the boilers that are actually being sold. In order to look into this issue the distribution of boilers sold during the first quarter of 2004 and the first quarter of 2005 was examined in two natural gas areas in Denmark. One area was the Northern part of Jutland covered by the natural gas company Naturgas Midt-Nord. The other area was the Greater Copenhagen area, covered by the natural gas company Greater Copenhagen Natural Gas. In the Northern Jutland area 632 boilers were sold during the first quarter of 2004. 77 % of these had an A label. 16 % had no label, and the remaining 7 % had B, D and G labels. Correspondingly, 669 boilers were sold during the first quarter of 2005. 82 % of these had an A label. 11 % had no label and the remaining 7 % were B-E labelled boilers. In other words, A labelled boilers have gained an increasing market share at the expense of non-labelled boilers. The Greater Copenhagen area showed the same trend; however, with larger sales figures than in Jutland and with a slightly smaller share of A labelled boilers. Similar detailed statistics are not available in the other Danish natural gas areas (Southern part of Jutland, Funen and Zealand). There is a tendency, though, that the share of condensing boilers is high and steadily increasing in these areas. Of course, a number of parameters can be said to influence the market development in favour of A labelled boilers, but the introduction of the labelling scheme has contributed considerably. In addition, the gas industry has for several years promoted condensing gas boilers, and for quite some time now, the gas industry has been aware of the 2006 changes to the Danish Building Regulations regarding minimum requirements to boiler efficiency. How do consumers and the energy industry use the label? During the summer of 2005 70 new natural gas installations were inspected in a series of spot tests to check that the end user was informed of the correct energy labelling of his new boiler by means of a label attached to the gas boiler and corresponding information included in the user manual for the particular boiler. A few boiler suppliers had already implemented the energy labelling to their product and in the user manual. However, most of the spot tests revealed that many end users were not aware of the energy label of their new boiler. The market surveillance further included visits to Danish installer trade exhibitions and examination of campaign material. It was found that most boiler suppliers are labelling their boilers at exhibitions, and that to a great extent campaign material is including the labels and corresponding information. However, the examination revealed that for some of the boilers the campaign material only includes part of the label and leaves out the logos at the bottom of the label. In order to solve this problem, a simple arrow was developed that can be used if there is not enough room for the entire label. Energy labelling and the new requirements of the 2006 Building Regulations The Danish Building Regulations of 2006 introduces new requirements to gas boilers that - like the energy labelling scheme - promote the best boilers; i.e. boilers with full-load and part-load efficiencies according to the CE labelling tests of above 96 % and 104 %, respectively. This means

that in the future only condensing gas boilers will be represented in the Danish market in the case of boiler replacement as well as in the case of new buildings. The question is, how does this relate to the labelling scheme? Will this mean that in the future only A labelled boilers meet the new requirements? The answer is No. According to DGC s database there are both B and C labelled boilers and even one D labelled boiler that fulfil the new requirements. 7. CONCLUSIONS In the work we have developed an easy-to-use and objective evaluation tool that - based on a few key figures - can be used to compare and to choose between a number of domestic gas boilers. The tool was prepared for EU standardization. After a one-year pilot period it appears that the energy labelling scheme has indeed influenced the boiler market: - During this one-year period, the boiler manufacturers have adapted their boilers regarding the electrical components. Boilers that originally were sold with three-stage pumps have been modified to be sold with modulating pumps. - The supply of the best A labelled boilers is increasing at the expense of B-G labelled boilers. - The gas company show rooms only show A labelled boilers today. - As the labelling system is a voluntary system, some boilers are still not labelled. The Danish gas industry has fully supported the labelling system. The boiler manufacturers commitment is mainly due to the fact that the labelling system has been prepared for EU standardisation. Such standardisation may in the long run result in a reduction of the number of boiler tests in the individual countries.

8. REFERENCES 1. http://www.boilsim.com/ 2. http://www.dgc.dk/tekniker/energimaerke.htm 3. http://www.dgc.dk/tekniker/info_leveran.htm 9. LIST OF TABLES Table 1: The template of the design of the label Table 2: Definition of the different categories of hot water needs 10. LIST OF FIGURES Figure 1: The template of the design of the label Figure 2: Criteria for choice of hot water tank Pas photo of Karsten V. Frederiksen, main author