Catalog HY /US SERIES DESCRIPTION PAGE NO. SUPER COILS CC... 1/2 Solenoid Tubes... CE3-CE4 CA... 5/8 Solenoid Tubes...

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

4 Posiflow Proportional Solenoid Valves

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Pressure transmitter For general industrial applications Model A-10

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

General Information. Installation Wiring Practices for Vickers Electronic Products

Coils - Connectors. Coils Connectors. Summary. RE /03.16 Replaces: RE / Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Multi-function Card. 1 Description. 2 Technical data ESSK General. 1.2 Application example

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Cable Plug acc. to DIN EN , Form A

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

System 8. ü ( System 8

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Single sub-base valve

Navigate the Catalog HYDRA FORCE. Solenoid Valves. About HydraForce. System Manifolds. How to Contact Us. Electro-Proportional Valves

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Electronic Pressure Switch EDS 300

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

mpm DIN CONNECTORS

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Inductive sensor NI10-M18-Y1X-H1141

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Ordering Part Numbers:

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

3/2 Solenoid Cartridge Valve, Size 6


3/2- and 2/2-way cartridge valve type BVE

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Coils - Connectors. Coils Connectors. Summary. RE / /10 Replaces: RE / Description

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Assisted lift operated 2/2-way solenoid valves Type EV250B

Contents. Document information

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Digital inductive conductivity transmitter

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

Proportional pressure regulators VPPE

Electronic Pressure Switch EDS 3000

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Duct Humidity Transmitter

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Givare NC-SRS 280 och 880

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

maxon sensor maxon sensor

Series 8146/5-V37 and Series 8150/5-V37

Adjustment functions for both span and shift have been incorporated

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Thermal-Magnetic Circuit Breaker M1-..

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

VSO MAX HP High Flow Proportional Valve

ATL Fuel Level Sender Probes

Directory chapter 04

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

HERZ-Thermal Actuators

Line-Mounted Valves L Series

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

3 Port Solenoid Valve

Typical Aluminum GFM Mass Flow Meter

Electric Rotary Actuator - On/Off or programmable control actuator

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Heavy Duty Pressure Sensors/ Transducers Line Guide

On-off valves MS-EM/EE, MS series, NPT

ELECTRONIC CONTROL UNITS. Machine Management Systems. Description. EC-MMS-1012-H 10 inputs, 12 outputs meter-in systems controller 20

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Cross-beam scanning system to detect slim objects. 100 mm in

Actuators and Sensors. Products

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

LED...A Q Series Sealed High-Intensity

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

3753 en /b VE/B - VE/RG Va V riable speed drives

3/2-way Solenoid Valve, direct-acting, NC or NO

Analog Servo Drive 25A8

Vario-Series Accessories

How To Read A Pipe From A Sensor

38 Series - Relay interface modules A

Transcription:

oils and Electronic ontrols Section ontents Typical Application Model Pressure bar (psi) Page oils Toughoils Information... -3 Toughoils Model ode and Specifications... -4 S Series...for 8 size solenoid valves... -5 P Series...for 8 size solenoid valves... -5 J Series...for 10,12,16, 20 size solenoid valves... -6 H Series...for 10,12,16, 20 size solenoid valves... -6 oil Dimensions...S & P Series oils... -7 oil Dimensions...J Series oils... -8 oil Dimensions...H Series oils... -9 R & L Series coils...for 12 size 3 & 4 way solenoid valves... -10 13*16 Information... -11 13*16 Model ode... -12 Explosion proof valve coils...for SV*E series valves... -13 EPV proportional valve coils... -15 EFV proportional valve coils... -16 Proportional Valve Drivers Power Plugs for Proportional valves...ehh-amp-702-d/k-* Series... -17 Soft Switch Power Plugs...EHH-AMP-702--* 10 Series... -23-2.A.B

Toughoils Information Toughoils Eaton/IH Toughoils have been designed to provide industry leading environmental protection and solenoid performance in a compact and rugged package. Toughoils with integrated connectors are rated up to IP69K environmental protection. Toughoils are available with a variety of popular integrated connection options and with wire leads. The best in class, one-piece, shell encapsulated, design meets the most stringent environmental requirements for mobile and industrial applications. The exclusive compact coil design from Eaton/IH, offers the advantage of field retrofitability on all existing, and new, applications. Toughoils Features IP69K Environmental Protection - This rating provides protection against the ingress of dust and high pressure jet stream. The IP69K test was designed specifically for rating protection against a high-pressure jet stream, high liquid temperature and close nozzle distance from the enclosure surface. IP69K protection is standard on coils with MetriPac or Deutsch, integrated connectors. "Thermal Shock Dunk Test - Eaton/IH Toughoils have been qualified to withstand the toughest Mobile Equipment Thermal Shock Dunk tests. Integrated Deutsch, MetriPack 1 and Leadwire 2 connectors exceed Thermal Shock Dunk test qualifications at 140. The Thermal Shock Dunk test requires coils to be heated, reaching a stabilized temperature of 100, then immediately immersed in a solution at 0. The thermal shock is repeated five times with the coil monitored for dielectric strength in the solution and functional performance is verified. In addition, Toughoils passed a more severe powered dunk test conducted from 100 to 0 with 115% rated voltage applied. Field Retrofitable - Toughoils replace all current Eaton coils used on D Frame and Shell type coils. ompact coil dimensions allow substitution in all existing applications. Toughoils are available for most 8, 10, 12, 16 and 20 series valves. No additional water/weather proofing is required. Steel Shell Encapsulated Design - Toughoils provide protection against physical and environmental damage. 1 MetriPack 150 and MetriPack 280 are registered trade marks of Delphi Packard Electric Systems 2 oils with integrated connectors are recommended for applications in harsh environments. Eaton/IH Toughoils, with rated connector, meet or exceed all major OEM environmental protection requirements Shown with deutsch connection options -3.A.B

Toughoils Model ode S,P,J and H Series oils Model ode MS * *** * ** * ** 10 1 2 3 4 5 6 7 8 1 Function MS - Solenoid coil 2 Series S - Size 8 (210 Bar) P - Size 8 (350 Bar) J - Size 10, 12, 16, 20 (210 Bar) H - Size 10, 12, 16, 20 (350 Bar) 3 Voltage Rating 012-12 volt 024-24 volt 036-36 volt 048-48 volt 115-115 volt 230-230 volt 5 onnector G0 - ISO 4400 DIN 43650 Q0 - Spade Terminals W0 - Flying lead N0 - Deutsch Male, DT04-2P, Integrated (D Only) Mating onnector: Deutsch DT06-2S Y0 - Amp Jr (D Only) Mating onnector: AMP 963040-3 or equivalent D0 - MetriPack 150 Male, Integrated (D Only) Mating onnector: Delphi 12052641 J0 - MetriPack 280 Male, Integrated (D Only) Mating onnector: Delphi 15300027 E0 - Weather Pack (Packard) female on wire leads Mating onnector: Delphi 12010973 F0 - Weather Pack (Packard) male on wire leads Mating onnector: Delphi 12015792 Note: Auxillary parts for mating connectors may be required. 6 Lead Length 0 - None A - 152mm [6.0 in] (Standard length with connector) B - 610mm [24.0 in] (Standard length without connector) 7 Special Features 00 - None (Only required if valve has special features, omitted if 00. ) 8 Design ode 10 - Design code 4 Voltage Type D - D B - D/with flyback diode A - A/with full bridge rectifier Specifications Ratings and Specifications Duty Rating ontinuous from 85% to 110% of nominal voltage Operating temperature 100 (212 F) continuous @ nominal voltage Lead Wires 18 gauge, standard 610 mm (24 ) long, UL style 3173 SA L 1251 (meets SAE J1128 XLPE style SXL) Power Rating S Series: 20W P Series: 23W J Series: 23W H Series: 29W Encapsulent Glass filled nylon Magnet Wire U.L. class N, 200 (392 F) NEMA pub. No. MW 1000, section MW 35 (single) Flyback diode (arc suppressor) Maximum recurrent peak reverse voltage 800 V (optional) Environmental Protection AUTION oils may be hot to touch if used in continuous duty applications. onnector Ip65 Ip67 Ip69k Thermal Shock Dunk G0: DIN 43650 X* Q0: Spade Y0: Amp Jr. X X 1 * W0: Wire Leads X X X 1 N0: Deutsch X X X X D0: Metri-Pack 150 X X X X J0: Metri-Pack 280 X X X X 1 Passed environmental testing, but not as robust as other connectors *Rating dependent on mating connector -4.A

Toughoils For 8 Size Solenoid Valves S & P Series oils S Series Toughoils part numbers - 300AA00 (omplete Part number is 11 Digits) G0** Q0 W0 N0 Y0 D0 J0 Voltage onnector onnector onnector onnector onnector onnector onnector 12VD 001A 009A 015A 021A 026A 031A 036A 24VD 002A 010A 016A 022A 027A 032A 037A 36VD 003A 011A 017A 023A 028A 033A 038A 24VA 004A 012A 018A 115VA 005A 230VA 006A 12VD* 007A 013A 019A 024A 029A 034A 039A 24VD* 008A 014A 020A 025A 030A 035A 040A *With flyback diode. (Voltage Type B) **DIN 43560 mating connector for G0 style coil 02-166796. For other voltages and connectors contact your Eaton representative. Std. Voltages Amperes* 12 D 1.67 24 D 0.83 36 D 0.56 24 A 0.93 115 A 0.19 230 A 0.10 *Nominal voltage 25 (77 F). Voltage Type B (+) (- P Series Toughoils part numbers - 300AA00 (omplete Part number is 11 Digits) G0** Q0 W0 N0 Y0 D0 J0 Voltage onnector onnector onnector onnector onnector onnector onnector 12VD 041A 049A 055A 061A 066A 071A 076A 24VD 042A 050A 056A 062A 067A 072A 077A 36VD 043A 051A 057A 063A 068A 073A 078A 24VA 044A 052A 058A 115VA 045A 230VA 046A 12VD* 047A 053A 059A 064A 069A 074A 079A 24VD* 048A 054A 060A 065A 070A 075A 080A *With flyback diode. (Voltage Type B) **DIN 43560 mating connector for G0 style coil 02-166796. For other voltages and connectors contact your Eaton representative. Std. Voltages Amperes* 12 D 1.92 24 D 0.96 36 D 0.64 24 A 1.06 115 A 0.22 230 A 0.11 *Nominal voltage 25 (77 F). Voltage Type B (+) (- -5.A

Toughoils For 10, 12, 16 and 20 Size Solenoid Valves J & H Series oils 300AA00 (omplete Part number is 11 Digits) G0** Q0 W0 N0 Y0 D0 J0 Voltage onnector onnector onnector onnector onnector onnector onnector 12VD 081A 089A 095A 101A 106A 111A 116A 24VD 082A 090A 096A 102A 107A 112A 117A 36VD 083A 091A 097A 103A 108A 113A 118A 24VA 084A 092A 098A 115VA 085A 230VA 086A 12VD* 087A 093A 099A 104A 109A 114A 119A 24VD* 088A 094A 100A 105A 110A 115A 120A *With flyback diode. (Voltage Type B) **DIN 43560 mating connector for G0 style coil 02-166796. For other voltages and connectors contact your Eaton representative. Std. Voltages Amperes* 12 D 1.92 24 D 0.96 36 D 0.64 24 A 1.06 115 A 0.22 230 A 0.11 *Nominal voltage 25 (77 F).* Voltage Type B (+) (-) H Series Toughoils part numbers - 300AA00 (omplete Part number is 11 Digits) G0** Q0 W0 N0 Y0 D0 J0 Voltage onnector onnector onnector onnector onnector onnector onnector 12VD 121A 129A 135A 141A 146A 151A 156A 24VD 122A 130A 136A 142A 147A 152A 157A 36VD 123A 131A 137A 143A 148A 153A 158A 24VA 124A 132A 138A 115VA 125A 230VA 126A 12VD* 127A 133A 139A 144A 149A 154A 159A 24VD* 128A 134A 140A 145A 150A 155A 160A *With flyback diode. (Voltage Type B) **DIN 43560 mating connector for G0 style coil 02-166796. For other voltages and connectors contact your Eaton representative. Std. Voltages Amperes* 12 D 2.42 24 D 1.21 36 D 0.81 24 A 1.34 115 A 0.28 230 A 0.14 *Nominal voltage 25 (77 F). (+) Voltage Type B (-) -6.A

S and P Series oils J & H Series oils Dimensions 28,0 [1.10] 34,3 [1.35] 29,5 [1.16] 39,7 [1.56] G0 DIN 43650-A onnector 31,8 [1.25] 12,9 [.51] Shown with integrated Deutsch onnector 17,5 [0.69] 34,5 [1.36] 29,5 [1.16] 26,2 [1.03] 26,2 [1.03] 28,0 [1.10] Q0 Spade onnector W0 Leadwire 37,1 [1.46] 35,6 [1.40] 31,2 23,4 [1.23] [.92] 24,9 [.98] 34,8 [1.37] 27,9 [1.10] N0 Deutsch Male DTO4-2P integrated connector Y0 AMP Junior Timer integrated connector 35,1 [1.38] 37,6 [1.48] 29,7 [1.17] 24,1 [.95] 33,9 [1.33] 25,4 [1.00] D0 Metri-Pack 150 Male, integrated connector J0 Metri-Pack 280 Male, integrated connector -7.A

J Series oils Dimensions 33,5 [1.32] (.685) 29,5 [1.16] 31,5 [1.24] 46,5 [1.83] Ø 38,9 [1.53] 12,9 [.51] G0 DIN 43650-A onnector Shown with integrated MetriPack 150 onnector (.685) 34,3 [1.35] 29,5 [1.16] 26,2 [1.03] 29,7 [1.17] 31,5 [1.24] Q0 Spade onnector W0 Leadwire 36,8 1.45] 35,3 [1.39] 5,1 [.20] 34,8 [1.37] 28,4 [1.12] 38,4 [1.51] 31,5 [1.24] N0 Deutsch Male DTO4-2P integrated connector Y0 AMP Junior Timer integrated connector 35,1 [1.38] 37,6 [1.48] 33,3 [1.31] 27,7 [1.09] 37,3 [1.47] 28,9 [1.14] D0 Metri-Pack 150 Male, integrated connector J0 Metri-Pack 280 Male, integrated connector -8.A

H Series oils Dimensions 33,5 [1.32] (.685) 29,5 [1.16] 31,5 [1.24] 46,5 [1.83] Ø 38,9 [1.53] 17,6 [.69] G0 DIN 43650-A onnector Shown with integrated MetriPack 280 onnector (.685) 34,3 [1.35] 29,5 [1.16] 26,2 [1.03] 29,7 [1.17] 31,5 [1.24] Q0 Spade onnector W0 Leadwire 36,8 1.45] 35,3 [1.39] 5,1 [.20] 34,8 [1.37] 28,4 [1.12] 38,4 [1.51] 31,5 [1.24] N0 Deutsch Male DTO4-2P integrated connector Y0 AMP Junior Timer integrated connector 35,1 [1.38] 37,6 [1.48] 33,3 [1.31] 27,7 [1.09] 37,3 [1.47] 28,9 [1.14] D0 Metri-Pack 150 Male, integrated connector J0 Metri-Pack 280 Male, integrated connector -9.A

R & L Series oils For SVx-12-3 and SVx-12-4 Solenoid Valves L Series oils ( EN490 oils) D oils onnector Voltage G DIN 43650 onnector W Leadwires Only Full Power oils: 12V 02-309454 02-309452 24V 02-309455 02-309453 Note: For more information on L series coils, please refer to Eaton Technical datasheet 5049/EN/0596/A (Solenoid Operated Directional Valve-DG4V-35, EN490 for Mobile Equipment). R Series oils (Blue oils) D oils Voltage G DIN 43650 onnector Q SpaDe onnector W Leadwires Only Full Power oils: onnector 12V 507847 02-111166 02-140394 24V 507848 02-111168 02-140395 Note: For more information on R series coils, please refer to Eaton Technical datasheet V-VLDL-M011-E (Solenoid Operated Directional Valve-DG4V-35 and DG4V3 Series). R and L Series oils Power onsumption D solenoids at rated voltage and 20 (68 F) Full Power oils: 12V 30W 24V 30W -10.A.B

13 and 16 Series - oil Information Duty Rating FPO Electrical onnection Bobbin Encapsulation opper Winding The coil is rated for continuous operation at nominal voltage +/- 10% and an ambient range of -20 to +40. Note: oil performance, force produced and power consumed, is affected by the heat of the coil, performance figures given in this catalogue are measured under simulated continuous duty conditions at the coil stabilized temperature. It is important to verify the actual conditions the valve will experience for any given application it should be tested in situ to confirm valve selection. Wattage 13 (for 13 mm tubes) = 14, 22 & 27 Watts 16 (for 16 mm tubes) = 19 & 29 Watts Voltages Standard 12 VD 110 VRA 24 VD 220 VRA Special/Optional Other Voltages are available on request Alternating urrent Iron Frame/Yoke Location of O ring seal between coil and tube For A voltage an ISO4400 rectified connector must be used, as the coils are wound for D. The correct connector is available from the factory: Wire Insulation The coil winding is copper magnet wire insulation equivalent to class N (200 ). Encapsulation Material 13, 14 Watt coils and 16, 19 Watt coils are black in colour and made from PBT (Black Polybutylene Reinforced) equivalent to lass F (155 ) 13, 22 & 27 Watt coils and 16, 29 Watt coils are black in colour and made from IXEF (Black Polyarylamide Reinforced) equivalent to lass H (180 ) Ingress Protection (IP) BS EN 60529 The coil/tube joint is sealed by O rings preventing fluid ingress and the possibility of tube corrosion. Different electrical connectors offer different levels of protection the minimum being the DIN 43650 connector with a gasket at IP65. Integrated Hydraulics offer a wide range of connector types - details of which are available on request. 110 VA = AXP9997-115 220 VA = AXP9997-230 VDR is fitted for over-voltage protection. Diodes are rated at 1.5 amp. + onnectors H = ISO4400 Standard DIN43650 2 pin and earth F = Black Flying Leads 1.5mm 2 wire 600 mm long, 15 AWG, 2.2 mm diameter, Teflon FEP covered (D voltage only) DM = Deutsch Moulded 2 way DT04-2P series (D voltage only). D oil aution When handling coils after or during use they may be hot which can cause burning to the skin. Handle with care and use the appropriate equipment. - A Voltage onnector ircuit Diagram -11.A

13 and 16 Series - Solenoid oil Model ode 13 H 24 / 22 1 2 3 4 1 oil Series 13-13 mm tube 16-16 mm tube 2 onnection H - DIN43650 ISO Standard F - Flying Leads (12 and 24 VD only) DM - Deutsch Moulded (12 and 24 VD only) (onsult factory for other options) We reserve the right to change specifications without notice 3 Voltage 4 Wattage 12 12 VD 13 16 14 = 14 Watt 19 = 19 Watt 24 24 VD 22 = 22 Watt 29 = 29 Watt 110 110 VRA 27 = 27 Watt 220 220 VRA* *220 to 240 VA All A coils must be used with a rectifying connector: (AXP9997-115 or AXP9997-230) (Other voltages available on request) 13 oils 47.8 (1.88) 16 oils 49.0 (1.93) 38.1 (1.50) 50.0 (1.97) 23.9 (0.94) 36.0 (1.42) 35.5 (1.40) 22.0 (0.87) -12.A

Explosion Proof Valves For hazardous environments oil Options (SV*E Series) Specifications Hydraulic Performance Specifications for explosion proof valves are the same as the base valve. For details please refer to the base valve page reference. oil Temperature Range -40 to 100 (-40 to 212 F) oil Duty ontinuous from 85% to 110% of nominal voltage Housing Type Explosion proof version with 1/2" threaded conduit hub oil Type Epoxy encapulated lead wire coil Lead Wire 24" Long, 18 gauge with 1/32" cross linked Polyethylene insulation Approvals UL SA File AU2206, omponent - Industrial truck accessory, Battery powered Both for general purpose and Hazardous locations lass I, Group & D lass II, Group E, F & G Summary Typical Application Rated flow Base Valve Section Model ode Reference Description Pressure psi (bar) l/min (Usgpm) design SV1E-10--XX-XXXXU 2 way, 2 position, normally closed, poppet type 210 (3000) 45 (12) SV1-10- A SV2E-10--XX-XXXXU 2 way, 2 position, normally closed, poppet type 210 (3000) 23 (6) SV2-10- A SV3E-10--XX-XXXXU 2 way, 2 position, normally closed, poppet type 210 (3000) 45 (12) SV3-10- A SV4E-10--XX-XXXXU 2 way, 2 position, normally closed, spool type 210 (3000) 23 (6) SV4-10- A SV1E-16--XX-XXXXU 2 way, 2 position, normally closed, poppet type 210 (3000) 132 (35) SV1-16- A SV2E-20--XX-XXXXU 2 way, 2 position, normally closed, poppet type 210 (3000) 227 (60) SV2-20- A SV4E-10-0-XX-XXXXU 2 way, 2 position, normally open, spool type 210 (3000) 23 (6) SV4-10-0 A SV3E-10-0-XX-XXXXU 2 way, 2 position, normally open, poppet type 210 (3000) 45 (12) SV3-10-0 A SV5E-10-0-XX-XXXXU 2 way, 2 position, normally open, poppet type 210 (3000) 45 (12) SV5-10-0 A SV3E-16-0-XX-XXXXU 2 way, 2 position, normally open, poppet type 210 (3000) 132 (35) SV3-16-0 A SV3E-20-0-XX-XXXXU 2 way, 2 position, normally open, poppet type 210 (3000) 227 (60) SV3-20-0 A SV1E-10-3-XX-XXXXU 3 way, 2 position, spool type 210 (3000) 23 (6) SV1-10-3 A SV1E-10-4-XX-XXXXU 4 way, 2 position 210 (3000) 23 (6) SV1-10-4 A SV2E-10-4-XX-XXXXU 4 way, 2 position, circuit center 210 (3000) 23 (6) SV2-10-4 A SV3E-10-4-XX-XXXXU 4 way, 2 position, normally open 210 (3000) 23 (6) SV3-10-4 A SV4E-10-4-XX-XXXXU 4 way, 2 position, tandem center 210 (3000) 23 (6) SV4-10-4 A Replacement oil Part Numbers Voltage Assembly Number Amperes (A) Power (W) Lead olor 12 VD 888831 1.50 20 Red 24 VD 888832 0.75 20 Black 36 VD 888834 0.50 20 Blue 48 VD 888835 0.38 20 Purple 110 VD 888836 0.16 20 Brown 24 VA 888837 0.75 20 Orange 115 VA 888838 0.16 20 Yellow 230 VA 888840 0.08 20 Red/White 480 VA 888841 0.04 20 Black/White -13.A

Explosion Proof Valves (SV*E Series) Model ode Model ode SV*E-**(V)-* *** **** U 1 2 3 4 1 Base Valve SV1E-10- SV1-10- SV2E-10- SV2-10- SV3E-10- SV3-10- SV4E-10- SV4-10- SV1E-16- SV1-16- SV2E-20- SV2-20- SV4E-10-0 SV4-10-0 SV3E-10-0 SV3-10-0 SV5E-10-0 SV5-10-0 SV3E-16-0 SV3-16-0 SV3E-20-0 SV3-20-0 SV1E-10-3 SV1-10-3 SV1E-10-4 SV1-10-4 SV2E-10-4 SV2-10-4 SV3E-10-4 SV3-10-4 SV4E-10-4 SV4-10-4 For performance specifications refer to base valve data sheet. Viton seal options are available. 2 Port Size Housing Number Refer to table in Model ode for Base valves 4.8 liters/min 3 Voltage* ode Voltage Replacement oil Part Number 12D 12 VD 888831 24D 24 DV 888832 36D 36 VD 888834 48D 48 VD 888835 110D 110 VD 888836 24A 24 VA 888837 115A 115 VA 888838 230A 230 VA 888840 460A 460 VA 888841 *Arc suppression diode is not available 4 Type (.S.A. Approved) U - 1/2" NPT onnector lass I, Group & D lass II, Group E, F & G Dimensions mm (inch) Description Type Note: artridge only or coil housing are not available as service parts. It is not possible to convert standard valves to explosion proof variants. SV1E-10-3 shown. Dimensions of coil housing are the same for all Vickers explosion proof SiV valves, for other dimensions please refer to base valve datasheet. 53,9 (2.125) 31,8 (1.250) 50,8 (2.0) "U" 0.5" N.P.T. onnector (24" Long Leads 18 GA.) 68,3 (2.69) 1.31 Hex -14.A.B

EPV Series Proportional Valve oils EPV oils ontrol and specifications Rheostat Power plug options Amplifier card Joystick suppliers 12 VD operation 10-12, 20-25 watts 24 VD operation 25-30, 20-25 watts EHH-AMP-702, EPAD-SA-1A6-10 (Require 24 VD power supply to power plug and 12 VD coil) EEA-PAM-523 (Requires 24 VD power supply and either 12VD or 24 VD coil) OEM ontrols, Inc, Shelton, T P-Q ontrols, Inc, Bristol, T Std. Voltages Amperes* Lead olor Power Rating 12 D 1.32 red 16 W 24 D.66 black 16 W *Nominal voltage @ 25 (77 F). oil part numbers F Q U* W Y Voltage onnector onnector onnector onnector onnector 12VD 02-308810 02-317154 02-154070 02-154072 02-308808 24VD 02-308811 02-317155 02-154071 02-154073 02-308809 *DIN 43650 mating connector for U style coil 02-166796. oil onfigurations F - Weather-Pack male on leads Q - Spade terminal U DIN 43650 AUTION oils may be hot to touch if used in continuous duty applications. W 610 mm (24 inch) lead wire Y - Metri-Pack 150 male on leads Note: Width all configurations Ø 43,5 (1.71) -15.A

EFV Series Proportional Valve oils EFV M Series oils ontrol and Specifications Power plug options DIN Rail Module EHH-AMP-702 (Requires 24 VD power supply to power plug and 12 VD coil) EHH-AMP-712 (Requires 12 VD power supply to power plug and 12 VD coil) EHH-PAM-600 (Requires 24 VD power supply and 12VD) AUTION oils may be hot to touch if used in continuous duty applications. Specifications Standard Voltage Resistance Power 12 VD 4.7 Ω 30 W 24 VD 19.0 Ω 30 W oil Model ode MS *** *** * ** ** ** ** 1 2 3 4 5 6 7 8 1 Function MS - Solenoid oil 2 Series M - Size 10 (210 Bar) 3 Voltage Rating 012-12 volt 024-24 volt 4 Voltage Type D - D 5 onnector G0 - ISO 4400 DIN 43650 W0 - Flying lead 0 - Deutsch Male, DT04-2P, On wire leads 6 Lead Length 0 - None A - 152mm [6.0 in] (standard length with connector) B - 610mm [24.0 in] (standard length without connector) K - 127mm [5.0 in] Note: Auxiliary parts for mating connectors may be required. DIN 43560 mating connector for G style coil 02-166796. oil Kits Standard oil Part Numbers 56,134 (2.21) Ø 44,2 (1.74) Ø 20,7 (0.815) 53.3 (2.10) Model ode Assembly Number MS012DGE00 54.6 6034440-001 (2.15) MS024DGE00 6034440-002 MS012DWE00 6034441-001 MS012DE06 6034442-002 S-024BGE00 4995052-232 Note: Width all configurations 56,134 (2.21) 53.3 (2.10) 54.6 (2.15) S-024BWE00 4995052-233 S-024DGE00 4995052-003 Note: Width all configurations -16.A G - DIN 43650 Ø 44,2 (1.74) Ø 20,7 (0.815) W - 610 mm (24 inch) lead wire Note: Width all configurations - Deutsch DT0402P on leads

Electronic ontrols Proportional Valve ontrol Power Plugs EHH-AMP-702-D/K-* Series Application General Description Features and Benefits For use with valve types: EPV**-12D-1* EFV1-**-012DE* ERV1/2**-12D-1* EPRV1/3**-12D-1* ESV1**-12D-1* IRV**-012D-1* PFR21* PFR24* PDR21A* PPD22**-012D-1* Primary applications are in the control of non-feedback proportional valves where the cost of more sophisticated electronic controls can be avoided. Type J is typically used in closed-loop applications. Three types of plugs, conforming to ISO 4400/DIN 43650 interface, with integral amplifiers and necessary adjustment potentiometers, are designed for use with non-feed back hydraulic valves. This plug/valve combination offers very low cost solutions to many hydraulic control problems requiring proportional control. Type D is controlled with a 0-10V command signal, and has adjustable gain, ramp, deadband compensation and dither. For closed-loop and no ramp applications adjust the ramp port to minimum setting. Type K is controlled with a 4-20 ma command signal, and has an adjustable ramp time of 50 ms to 5s. Integral amplifier provides essential functions for control of proportional valves Adjustable ramp time (types D and K), gain, deadband compensation and dither Ease of installation, with reduced cost Fully short-circuit and reverse-polarity protected Differential voltage command signal (type D) Adjustable dither EM to latest European standards Protection to IP67 Electrical Block Diagram Electrical Block Diagram EHH-AMP-702-D/K-* Note: This product has been designed and tested to meet specific standards outlined in the European Electro-magnetic ompatibility Directive (EM) 89/336/EE, amended by 91/26/EE, 92/31/EE and 93/68/EE, article 5. For instructions on installation requirements to achieve effective protection levels, see this leaflet and the Installation Wiring Practices for Vickers Electronic Products leaflet 2468. Wiring practices relevant to this Directive are indicated by a warning symbol and Electromagnetic ompatibility (EM). onnection Diagram onnection diagram for AN version (EHH-AMP-702-N--N-3-30) Pin Number Description 1 AN Shield 2 Supply Positive 3 Supply GND 4 AN H 5 AN L onnection diagram for RS232 Versions (EHH-AMP-7XX-X-R-P-X-30) onnector Pin Number Description -17.A.B Supply 1 Supply Positive onnector 2 Supply GND

Model ode/ Operating Data Model ode EHH - AMP - 702 - * - R - P - * - 30 1 2 1 Adjustment Range D - Proportional plug: 0-10 VD with ramp K - Proportional plug: 4-20 ma with ramp 2 able Gland 1 - PG9 2 - M16 Operating Data Electrical Types D Type K onnections 1 24V D 2 Supply GND 3 Positive command signal 4 Negative command signal Power (input) supply 18-36V D including ± 10% maximum ripple (peak-to-peak) 24V D nominal Absolute maximum voltage 40V Max. power consumption 35W including solenoid Reverse polarity protected Yes Short circuit protected Yes Maximum output current 1,6A Maximum output voltage typical Typically 1,5V below supply voltage (1,6A output current) ommand signal 0-10V (10 kohms) 4-20 ma (250 ohms) Deadband triggering 200 mv 4 ma For output (LED on) 200 mv to 10V 4-20 ma For no output (LED off) 0 mv to 100 mv 0-4 ma Deadband adjustment range 100 to 1000 ma Gain adjustment range 0.02A/V to 0.16A/V 0.01 A/mA to 0.08 A/mA Dither adjustment range 0 to 500 ma Ramp time (types D and K only) 50 ms to 5s PWM frequency 1200 Hz ± 10% Dither frequency 120 Hz ± 10% Protection IE 529: IP67 (when correctly installed with interface seal in place) Fully short-circuit and reverse-polarity protected Isolation to VDE 0110 Group B Electromagnetic compatibility (EM): Emission EN 50081-2 Immunity EN 50082-2 Mechanical Housing PA6 glass-reinforced plastic (conforming to UL-94HB). olor: gray Mounting interface ISO 4400 (DIN 43650) able clamp Pg9 screw type able diameter Ø 5 to 10 mm (0.197 to 0.394 dia.) Wire section 0,5 to 1,0 mm2 (20-17 AWG) Temperature, ambient range -20 to +70 (-4 to +158 F) Mass 0,07 kg (0.154 lb) -18.A.B

Installation Data Input/Output haracteristics Type K and D Type J Type ommand K D signal ommand Type K signal Type D Type 20 KmA Type 10V D 8V 20 ma 12 ma 10V 6V 8V 4V 12 ma 6V 2V 4 ma 4V 2V 4 ma Output current Output current Type ommand J signal ommand voltage Us signal voltage 10V Us 8V 10V 6V 8V 4V 6V 2V Time 4V 2V Time Ramp Output setting current Ramp Output setting current U S X U Gain setting Deadband S X compensation Gain setting Deadband Time compensation Time U S X U Gain setting Deadband S X compensation Gain setting Deadband compensation Time Time Time Time Installation Dimensions mm (inch) 88 (3.52) 88 (3.52) 22 (0.87) 22 (0.87) 3rd angle projection 3rd angle projection 39 (1.54) 39 (1.54) 34 (1.34) 34 (1.34) Solenoid onnections Solenoid onnections No connection 1 (or 2) No connection 1 (or 2) 38 (1.5) 38 (1.5) 1 2 1 2 2 (or 1) 2 (or 1) -19.A.B

1 PG9 cable clamp 2 M16 cable clamp 3 M12 5 pin connector Features Installation and Benefits Data Integral amplifier provides essential functions for control of proportional valves. Adjustable ramp time, gain, dead band compensation through potentiometer or RS232/AN communication (via software). Adjustments Ease of installation, with reduced cost. Ramp time: Turn clockwise Terminal 1: Power Supply Fully to increase short-circuit ramp time and reverse-polarity 18-36V protected. D, positive. (Only types D/K). Differential voltage command signal. Terminal 2: Power Supply 0V. Gain: Turn clockwise to Terminal 3: ommand Options increase with gain. RS232 and AN communication. signal positive Peak Deadband and Hold compensation: Functionality. (see Operating Data ). Turn clockwise to increase Terminal 4: ommand PG9, deadband M16 compensation cable clamp and M12 signal connector negative options. current. (see Operating Data ). Adjustable dither. Dither: Turn clockwise to increase the dither current. Wiring Set-up Diagrams Procedure Protection to IP67 Available with ANOpen communications Application Designed for the control of direct-operated, non-feedback, proportional valves where the cost of more complex electronic controls can be avoided. product has been designed and tested to meet specific standards outlined in the European Electromagnetic ompatibility ctive (EM) 89/336/EE, amended by 91/263/EE, 92/31/EE and 93/68/EE, article 5. For instructions on installation uirements to achieve effective protection levels, see this leaflet and the Installation Wiring Practices for Vickers Electronic ducts This leaflet procedure 2468. Wiring describes practices the adjustments relevant on to the this Power Directive Plug are band. indicated Adjusting by Electromagnetic the power plug allows ompatibility the dead-band (EM). to be for setting the dead-band, gain and ramp rate on a non-feedback proportional valve. Proportional valves with over-lapped ing the spool jump across the dead-band when a small input electronically eliminated (dead-band ompensation) by mak- Installation Wiring Options spools have a range of spool travel where there is no flow signal is applied to the power plug. from the valve. This range of spool motion is called dead- The gain of the valve is the ratio of the opening of the valve (or flow rate from it) to the applied voltage input to the power plug. The ramp rate is the rate at which the power plug allows the valve to open (or close) when a step voltage input is applied to the power plug. In many applications this ramp would be used to gradually accelerate or decelerate an actuator. Installation precautions to eliminate leaks into the power plug: Use only cables with circular cross-sections and diameter between 5 10 mm (.2 -.4 ) Ensure that sealing grommet is present and installed correctly. It must be forced over the outer jacket of the cable. Ensure that all the gaskets are present and properly seated. Ensure that the plastic cover seats firmly and correctly on the center body post. 2 EATON DPPP atalog October 2011-20.A.B WARNING Electromagnetic ompatibility (EM) - Screened cables should be used and particular attention paid to the grounding of the screens as shown in the above diagrams. onnection diagram for AN version (EHH-AMP-702-N--N-3-30) Warning: Warning: Electromagnetic ompatibility ompatibility (EM) (EM) Note: Note: For EHH-AMP-7X2-N--N-3-30 For wiring wiring diagram diagram please please refer refer the connectionection diagram diagram for the for same. the the con- same.

Installation Data Assembly Showing Wiring onnection Points WARNING Ensure cable clamp nut is adequately Assemblies tightened to secure cable. Do not connect, or disconnect, the plug while power is on. Do not mount, or dismount, the plug while power is on. *All seals must be fitted correctly at plug installation to provide protection to IP67 (IE 529). Warning: Ensure cable clamp nut is adequately tightened to secure the cable. Do not connect, or disconnect, the plug while power is on. Do not mount, or dismount, the plug while power is on. -21.A.B

Installation Data Start-Up Procedure With the plug correctly wired but not mounted to the load provide with a D power supply (See table). Apply the command signal (ON) and check the Power ON LED (RED) illuminates. Reduce the signal to the ommand signal (OFF) level and check the LED (RED) goes out. If there is malfunction to the LED replace the plug. Switch off the power supply and command signal and connect the plug to the load. Ensure that the interface seal is correctly fitted and clamped between the mounting faces (essential for IP65 protection). Tighten the retaining screw. Ensure that no damage or injury will occur on the machine when the valve is operated. Switch on the power supply. Apply the command signal. (a) Observe Power On LED (RED) is ON. (b) Observe PWM LED (Orange) is ON. If LED is not operated then there is short circuit in the load. Replace the load/load coil. Successful completion of these steps means that the plug and load are ready for normal use. Spare Parts The only spare part available is the interface seal, part number 732100. Ordering Procedure Order plug by full model code, and spare interface seals by part number 732100. -22.A.B

Electronic ontrols Soft Switch Power Plugs EHH-AMP-702--* 10 Series For use with valve types: EPV**-12D-1* EFV1-**-012DE* ERV1/2**-12D-1* EPRV1/3**-12D-1* ESV1**-12D-1* IRV**-012D-1* PFR21* PFR24* PDR21A* PPD22**-012D-1* Application Focus applications for this plug are in the control of hydraulic solenoid operated directional and pressure control valves where control of valve response time can significantly reduce shocks in the hydraulic system. Best results in reducing hydraulic shocks will only be obtained by using valves with the right low shock, or proportional features. General Description These plugs, conforming to ISO 4400/DIN 43650 interface, offer adjustable, ramped on/off switching times through the use of an integral amplifier. The switching time range is 50 ms to 5 seconds. The soft switch plug is rated for 24V D nominal and controlled by a 24V logic signal. Applying an on signal causes the output current to ramp up to, and stay at, an adjustable maximum while the on signal is maintained. At switch-off the output current is ramped down to zero and will remain at zero until the next on signal. Features and Benefits Integral amplifier provides control from on/off logic command signal Adjustable ramp time Deadband compensation Adjustable output level Adjustable dither EM to latest European standards Improved switching time repeatability Fully short-circuit and reverse-polarity protected Protection to IP67 Ramp times (switching times) can be adjusted by an in-built potentiometer. An adjustment also allows for compensation of any deadband in the valve. Electrical Block Diagram EHH-AMP-702--* 10 Series Power input 24V D + 1 Dither X1 Note: This product has been designed and tested to meet specific standards outlined in the European Electro-magnetic ompatibility Directive (EM) 89/336/EE, amended by 91/26/EE, 92/31/EE and 93/68/EE, article 5. For instructions on installation requirements to achieve effective protection levels, see this leaflet and the Installation Wiring Practices for Vickers Electronic Products leaflet 2468. Wiring practices relevant to this Directive are indicated by a warning symbol and Electromagnetic ompatibility (EM). 0V ommand Signal 2 3 4 (N) 2k7W Ramp Gain Deadband Max. limiter PWM Power amp. Solenoid X2-23.A.B

Model ode/ Operating Data Model ode EHH - AMP - 702 - - * Operating Data Electrical onnections 1 24V D 2 OV (power and signal) 3 Positive command signal 4 Negative command signal Power (input) supply 18-36V D including ± 10% maximum ripple ripple (peak-to-peak) 24V D nominal Absolute maximum voltage 40V Max. power consumption 35W including solenoid Reverse polarity protected Yes Short circuit protected Yes Maximum output current 1,6A Maximum output voltage typical Typically 1,5V below supply voltage (1,6A output current) ommand signal For output (LED on) 11 to 24V For no output (LED off) 0V to 5V Input impedance 10 KOhm ohms Deadband adjustment range <100-1000 ma Gain adjustment range 0.02A to 1,6A (maximum) Dither adjustment range 0 to 500 ma Ramp time 50 ms to 5s PWM frequency 1200 Hz ± 10% Dither frequency 120 Hz ± 10% Protection IE 529: IP67 (when correctly installed with interface seal in place) Fully short-circuit and reverse-polarity protected Isolation to VDE 0110 Group B Electromagnetic compatibility (EM): Emission EN 50081-2 Immunity EN 50082-2 Mechanical Housing PA6 glass-reinforced plastic (conforming to UL-94HB). olor: gray Mounting interface ISO 4400 (DIN 43650) able clamp Pg9 screw type able diameter Ø 5 to 10 mm (0.197 to 0.394 dia.) Wire section 0,5 to 1,0 mm2 (20-17 AWG) Temperature, ambient range -20 to +70 (-4 to +158 F) Mass 0,07 kg (0.154 lb) -24.A.B

Installation Data Input/Output haracteristics Type K and D Type J Functions ommand signal Switch-on/off: after Type K Type D switching on with a 20 ma 10V 11V signal the amplifier 8V will remain in the on 12 ma 6V condition with a command 4V signal above 6V. The 2V 4 ma command signal must be reduced to below 5V Output to achieve switch-off of current the amplifier. ommand signal 24V, typical Ramp setting ommand signal voltage Us 10V 8V 6V 4V 2V Time Output Ramp time currentu S X Gain setting Deadband compensation Time Output current Time U S X Gain setting Deadband compensation Gain adjustment Time Time Deadband compensation Time Installation Dimensions mm (inch) 88 (3.52) 22 (0.87) 3rd angle projection 39 (1.54) Solenoid onnections 1 (or 2) No connection 34 (1.34) 38 (1.5) 1 2 2 (or 1) -25.A.B

Installation Data e able connection option 1 PG9 cable clamp 2 M16 cable clamp 3 M12 5 pin connector Adjustments Ramp time: Turn clockwise Features and Benefits to increase ramp time. Integral amplifier provides essential Gain: functions Turn clockwise for control to of proportional valves. increase gain. Deadband compensation: Adjustable ramp time, gain, dead Turn band clockwise compensation to increase through potentiometer or RS232/AN deadband communication compensation (via software). current. Ease of installation, with reduced Dither: cost. Turn clockwise to increase the dither current. Fully short-circuit and reverse-polarity protected. Differential voltage command signal. Options with RS232 and AN communication. Peak and Hold Functionality. PG9, M16 cable clamp and M12 connector options. Adjustable dither. EM to latest European standards. Protection to IP67 Terminal Available 1: Power with ANOpen Supply communications 18-36V D, positive. Application Terminal 2: Power Supply 0V. Terminal Designed 3: Switch for the command control of direct-operated, non-feedback, positive. proportional valves where the cost of more com- signal Terminal plex electronic 4: Not connected controls can be avoided. Set-up Procedure s product has been designed and tested to meet specific standards outlined in the European Electromagnetic ompatibility ctive (EM) Installation 89/336/EE, Wiringamended by 91/263/EE, 92/31/EE and 93/68/EE, article 5. For instructions on installation uirements to achieve effective protection levels, see this leaflet and the Installation Wiring Practices for Vickers Electronic ducts This leaflet procedure 2468. Wiring describes practices the adjustments relevant 24V on to the this Power Directive Plug are band. indicated Adjusting by Electromagnetic the power plug allows ompatibility the dead-band (EM). to be for setting the dead-band, WARNING gain and ramp rate 0V on a non-feedback proportional valve. Proportional valves >11 Vwith over-lapped ing the spool jump across the dead-band when a small input electronically eliminated (dead-band ompensation) by mak- Electromagnetic spools have a range ompatibility of spool (EM) travel where there is no flow signal is applied to the power plug. from the valve. - This Screened range cables of spool motion is called dead-protective ground connection should be used and particular attention paid to the grounding of the screens as shown in the above diagram. 1 2 3 4 The gain of the valve is the ratio of the opening of the valve (or flow rate from it) to the applied voltage input to the power plug. The ramp rate is the rate at which the power plug allows the valve to open (or close) when a step voltage input is applied to the power plug. In many applications this ramp would be used to gradually accelerate or decelerate an actuator. Installation precautions to eliminate leaks into the power plug: Use only cables with circular cross-sections and diameter between 5 10 mm (.2 -.4 ) Ensure that sealing grommet is present and installed correctly. It must be forced over the outer jacket of the cable. Ensure that all the gaskets are present and properly seated. Ensure that the plastic cover seats firmly and correctly on the center body post. 2 EATON DPPP atalog October 2011-26.A.B

Installation Data Assemblies Assembly Showing Wiring onnection Points WARNING Ensure cable clamp nut is adequately tightened to secure cable. Do not connect, or disconnect, the plug while power is on. Do not mount, or dismount, the plug while power is on. *All seals must be fitted correctly at plug installation to provide protection to IP67 (IE 529). Warning: Ensure cable clamp nut is adequately tightened to secure the cable. Do not connect, or disconnect, the plug while power is on. Do not mount, or dismount, the plug while power is on. -27.A.B

Installation Data Start-Up Procedure orrectly wire the plug and, before mounting it on the valve solenoid, apply 24V D (18 to 36V limits) to the power input terminals. heck for correct plug function by illumination/ non-illumination of the LED: a. Apply less than 2 to 3 volts to the input terminal: LED should not be illuminated. b. Increase voltage: the LED should illuminate when the voltage reaches 11V. Do not exceed 30V command signal. c. Decrease voltage: the LED should go off when the voltage is less than 5V. Switch off power supply and command/input signal and then install plug on solenoid. Ensure that all seals are fitted correctly and clamped as the retaining screw is tightened: this is essential in providing IP67 protection. Ensure that the hydraulic system will not cause any erratic movement of actuators, then: Switch on power supply again. Repeat LED/function check as in 2. An LED malfunction now indicates a short circuit at the load. Successful completion of these checks means that the plug and load are ready for use. Spare Parts The only spare part available is the interface seal, part number 732100. Ordering Procedure Order plug by full model code, and spare interface seals by part number 732100. -28.A.B