Experimental determination of cervical spine mechanical properties



Similar documents
MATERIALS AND METHODS

Side Impact Causes Multiplanar Cervical Spine Injuries

A MULTI-BODY MODEL OF THE WHOLE HUMAN SPINE FOR WHIPLASH INVESTIGATIONS

A Patient s Guide to Diffuse Idiopathic Skeletal Hyperostosis (DISH)

Cervical Spondylotic Myelopathy Associated with Kyphosis or Sagittal Sigmoid Alignment: Outcome after Anterior or Posterior Decompression

Structural behavior of human lumbar spinal motion segments

Aesculap Spine activ L

Spine University s Guide to Kinetic MRIs Detect Disc Herniations

Biomechanics of the Lumbar Spine

Whiplash: a review of a commonly misunderstood injury

Temple Physical Therapy

Patient Information. Lateral Lumbar Interbody Fusion Surgery (LLIF).

Study on Structural Behaviour of Human Vertebral Column Using Staad.Pro

Patient Information. Anterior Cervical Discectomy and Fusion Surgery (ACDF).

Stability of the spine modelled as an arch

A MORPHOMETRIC STUDY OF THE PEDICLES IN DRY HUMAN TYPICAL THORACIC VERTEBRAE

SPINE ANATOMY AND PROCEDURES. Tulsa Spine & Specialty Hospital 6901 S. Olympia Avenue Tulsa, Oklahoma 74132

ANTERIOR CERVICAL DISCECTOMY AND FUSION. Basic Anatomical Landmarks: Anterior Cervical Spine

Compression Fractures

SAE / Government Meeting. Washington, D.C. May 2005

Instability concept. Symposium- Cervical Spine. Barcelona, February 2014

Magnetic Resonance Imaging

1. Proposal Abstract. Table 1. Degeneration distribution of tested discs Grade I Grade II Grade III Grade IV Grade V # of discs tested

Acta of Bioengineering and Biomechanics Vol. 12, No. 2, 2010

.org. Cervical Radiculopathy (Pinched Nerve) Anatomy. Cause

.org. Fractures of the Thoracic and Lumbar Spine. Cause. Description

BODY BODY PEDICLE PEDICLE TRANSVERSE TRANSVERSE PROCESS PROCESS

1 REVISOR (4) Pain associated with rigidity (loss of motion or postural abnormality) or

Spinal Anatomy. * MedX research contends that the lumbar region really starts at T-11, based upon the attributes of the vertebra.

Spine Anatomy and Spine General The purpose of the spine is to help us stand and sit straight, move, and provide protection to the spinal cord.

Consideration on ACL/PCL Failure Evaluation

A multi-body head and neck model for low speed rear impact analysis

GENERATION OF A 3-D PARAMETRIC SOLID MODEL OF THE HUMAN SPINE USING ANTHROPOMORPHIC PARAMETERS. A thesis presented to.

On Cervical Zygapophysial Joint Pain After Whiplash. Spine December 1, 2011; Volume 36, Number 25S, pp S194 S199

SPINAL FUSION. North American Spine Society Public Education Series

InternatIonal JOURNAL OF ANATOMY PHYSIOLOGY and BIOCHEMISTRY

Human Anatomy & Physiology

Biomechanics of Joints, Ligaments and Tendons.

If you or a loved one have suffered because of a negligent error during spinal surgery, you will be going through a difficult time.

CHA SERIES. Key Chiropractic Concepts for the CHA. Ontario Chiropractic Association. Treatment That Stands Up.

Degenerative Changes of the Cervical Spine

Cervical Spine: Postmortem Assessment of Accident Injuries Comparison of Radiographic, MR Imaging, Anatomic, and Pathologic Findings

Disc Replacement or Fusion: which is best for me?

CERVICAL SPINE PROTECTION REPORT Prepared for NOCSAE

Biomechanics of the Neck in Rear Impacts for improved Seat Design

.org. Cervical Spondylosis (Arthritis of the Neck) Anatomy. Cause

visualized. The correct level is then identified again. With the use of a microscope and

Computer Aided Engineering (CAE) Techniques Applied To Hip Implant

Spine Trauma: When to Transfer. Alexander Ching, MD Director, Orthopaedic Spine Trauma OHSU

Biomechanical Analysis of the Deadlift (aka Spinal Mechanics for Lifters) Tony Leyland

Determining the Posture, Shape and Mobility of the Spine

Finite Element Modelling of Biomechanical Dummies- The Ultimate Tool in Anti-Whiplash Safety Design?

The biomechanics of the sheep cervical spine: an experimental and finite element analysis

An Anatomical Comparison of the Human and Bovine Thoracolumbar Spine

THE LUMBAR SPINE (BACK)

III./8.4.2: Spinal trauma. III./ Injury of the spinal cord

Spine Clinic Neurospine Specialists, Orthopaedics and Neurosurgery

Cervical Spondylosis (Arthritis of the Neck)

Evaluation and Treatment of Spine Fractures. Lara C. Portmann, MSN, ACNP-BC

SPINAL STENOSIS Information for Patients WHAT IS SPINAL STENOSIS?

From the Trenches Personal Injury Report Whiplash Injuries Review & Update on Facet Joint Trauma

Options for Cervical Disc Degeneration A Guide to the M6-C. clinical study

Whiplash and Whiplash- Associated Disorders

Low Back Injury in the Industrial Athlete: An Anatomic Approach

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

Pedestrian protection - Pedestrian in collision with personal car

INJURIES OF THE HAND AND WRIST By Derya Dincer, M.D.

Institute of Structural Engineering Division of Computer Aided Design Laboratory of Biomechanics

Introduction to Mechanical Behavior of Biological Materials

A review of spinal problems

Whiplash Associated Disorder

Development of a Detailed Human Spine Model with Haptic Interface

Degenerative Spine Solutions

Professor Alan Hedge, Cornell University, August 2013

The Furcal nerve. Ronald L L Collins,MB,BS(UWI),FRCS(Edin.),FICS (Fort Lee Surgical Center, Fort Lee,NJ)

Chapter 12 The Trunk and Spinal Column

Mechanics of the Human Spine Lifting and Spinal Compression

Neck Pain Overview Causes, Diagnosis and Treatment Options

Thoracic Spine Anatomy

The patellofemoral joint and the total knee replacement

Herniated Cervical Disc

Mechanical Diagnosis And Therapy of the Cervical Spine. The McKenzie Method. Allan Besselink, PT, Dip.MDT Smart Sport International Austin, Texas

Proposing a 2D Dynamical Model for Investigating the parameters Affecting Whiplash Injuries

MARTIN CHARLES HILLIER

Ron Schenk PT, PhD 1

CERVICAL SPONDYLOSIS

Non-Surgical Spinal Decompression with Computerized Spinal Table (Traction, Deep heat and Massage)

Contents. Introduction 1. Anatomy of the Spine Spinal Imaging Spinal Biomechanics History and Physical Examination of the Spine 33

Options for Cervical Disc Degeneration A Guide to the Fusion Arm of the M6 -C Artificial Disc Study

Highlighting of Intervertebral Movements and Variations of Intradiskal Pressure During Lumbar Spine Manipulation: A Feasibility Study

LUMBAR LAMINECTOMY AND DISCECTOMY. Basic Anatomical Landmarks: Posterior View Lumbar Spine

Discogenic Low Backache A clinical and MRI correlative study A DISSERTATION SUBMITTED TO UNIVERSITY OF SEYCHELLES AMERICAN INSTITUTE OF MEDICINE

Transcription:

Acta of Bioengineering and Biomechanics Vol. 10, No. 4, 2008 Experimental determination of cervical spine mechanical properties MAREK GZIK*, WOJCIECH WOLAŃSKI, DAGMARA TEJSZERSKA Division of General Mechanics and Biomechanics, Department of Applied Mechanics, Silesian University of Technology, Gliwice, Poland. The results of research into human cervical spine mechanical parameters necessary for process modelling are presented. Our tests were divided into identification of tissues mechanical features and determination of data useful for validating human cervical spine models. Mechanical properties of the whole cervical spine as well as the stiffness of ligaments and discs were identified on the basis of tests on cadaveric spinal specimens. Thanks to our cooperation with medical practitioners, physiological cross-section areas of neck muscles were analysed using MRI. Functional computed tomography was used to determine kinematics of cervical vertebrae during head movement in sagittal and frontal planes. Key words: human cervical spine biomechanics, spine tissues mechanical properties 1. Introduction In last decade, modelling in biomechanics becomes more popular as a method providing information about living organisms. Reasonably assumed tissue mechanical parameters of anatomical parts have a decisive effect on model attributes. Information about physical features of biological tissues could be obtained from literature, but in many cases data describing the same element are considerably different. Personal features of specimens and lack of standards of experiments are responsible for the situation. Many research centres in the world deal with recognizing biological material parameters but the knowledge about physics of living organisms is still incomplete. Development of biomedical technique allows us to see a human organism in a wider perspective due to discovering, for example, magnetic resonance imaging (MRI), functional computed tomography (CT) or needle electromyography (EMG). Unfortunately, the methods have some limitations, especially because of their invasive character. The need for an experimental method to investigate the behaviour of whole cervical spine specimens under normal physiologic loads has been recognized in the literature [1], [2], [4], [11]. Several static and dynamic models of human cervical spine were built by the scientists representing the Department of Applied Mechanics, Silesian University of Technology [4], [5]. Materials parameters of such models were previously assumed only on the basis of literature data, and the situation revealed different problems. Nowadays thanks to interdisciplinary cooperation between medical practitioners and new bioengineering laboratories it is possible to carry out pioneering experiments. The results of research allowing the model material parameters to be identified and verified are presented. * Corresponding author: Marek Gzik, Division of General Mechanics and Biomechanics, Department of Applied Mechanics, Silesian University of Technology, ul. Konarskiego 18a/18b, 44-100 Gliwice, Poland. E-mail: marek.gzik@polsl.pl Received: April 11th, 2008 Accepted for publication: November 4th, 2008

50 M. GZIK et al. 2. Experimental determination of human cervical spine stiffness The load displacement response of cervical spine was determined in the case of movements in sagittal, frontal and horizontal planes. Fresh spine segments consisting of seven adjacent vertebrae (C2 Th1) and their interconnecting ligaments, soft tissue and discs were obtained from six individual cadavers (two females and four males) between the ages of 55 and 65. The specimens were examined radiographically in order to exclude improper spines. For the load displacement analysis spines were mounted so that the external vertebrae were rigidly attached to the grip of a testing apparatus and the middle vertebrae were free to move in response to the loads applied. The investigations were done for physiological range of motion determined on the basis of literature data [4], [7], [8], [9], [10]. The tests were carried out using static strength machine MTS Insight 10 KN (figure 1) and an adapter of a special design (figure 2). Each segment was subjected to four tests: flexion and extension in sagittal plane, side bending in frontal plane and torsion in horizontal plane (figures 3 and figures 4). Th4 C7 C2 Fig. 1. Test carried out on human anatomical spine: a) human cervical segment C2 Th4 before tests, b) experimental stand Fig. 2. Adapter adjusted to: a) flexion extension spine movement in sagittal and frontal planes, b) rotation in horizontal plane

Experimental determination of cervical spine mechanical properties 51 Fig. 3. Averaged load displacement response of male ( ) and female ( ) cervical spines loaded: a) flexion, b) extension Fig. 4. Averaged load displacement response of male ( ) and female ( ) cervical spines loaded: a) side bending, b) torsion After spine stiffness identification, six anterior longitudinal ligaments (C3 C6) and discs (C6 C7) were isolated from specimens. Average crosssection area of ligaments in C4 C5 was 38 mm 2. Tensile strength of ligaments was determined. In order to avoid the problems of fixation, the ligaments were tested in situ with pressure holders (figure 5). a) Ligament Pressure holders b) Tensile force [N] 200 180 160 140 120 100 80 60 40 20 0 0 2 4 6 8 10 12 14 E longation [mm] Fig. 5. Tensile test of anterior longitudinal ligament: a) photo of in situ bone ligament bone preparation for tensile tests, b) averaged load elongation response

52 M. GZIK et al. Disc Compression holders Compression force [N] 600 500 400 300 200 100 0 0 1 2 3 4 5 6 Deformation [mm] Fig. 6. Compression test of disc: a) photo of device, b) average material characteristics determined Compressive properties of six intervertebral discs C6 C7 were determined (figure 6). Discs were isolated together with part of adjacent vertebral bodies. The total height of specimens amounted to 12 mm (6 mm front height of individual disc) and the crosssection area was 350 mm 2. Figures 5b and 6b present average response in male and female spines during the tests. 3. MRI of neck muscles Nowadays there is no technique which allows individual muscle forces to be measured. Muscles role in movement could be recognized using mathematical models. The modelling of muscles is based on the information about their anatomy and physiology. Physiological cross-section area is an important parameter in the process of muscle force identification. Due to our cooperation with Voxel Diagnosis Centre in Bytom the cross-section areas of male and female neck muscles were determined (figure 7). The experiments were conducted on five women (between the ages of 25 and 56) and five men (between the ages of 36 and 56). The group of main neck muscles responsible for head and cervical spine movement was analysed. Our research differs from those presented by other authors [3], [6], because it is based on threedimensional analysis of muscle volume. Each muscle was framed in the space, and its cross-section area was determined. The results were obtained for natural head position. Average physiological cross-section areas for right and left muscles are presented in the table. Table. Average physiological cross-section areas of male and female neck muscles Muscle Female Male (mm 2 ) (mm 2 ) Trapezius R * 695 1095 L ** 731 1106 Sternocleidomastoid R 275 364 L 278 396 Semispinalis capitis R 62 93 L 64 94 Splenius capitis R 77 94 L 75 95 Obliquus capitis inferior R 146 191 148 185 Rectus capitis posterior major R 74 108 L 76 106 Scalenus medius R 164 188 L 158 187 * Right, ** left. 4. Human cervical spine examination using functional computed tomography Fig. 7. MRI of sternocleidomastoid muscle with outline of physiological cross-section area Computed tomography (CT) is the method frequently applied in the diagnosis of a human skeletal

Experimental determination of cervical spine mechanical properties 53 Fig. 8. Results of cervical vertebra rotation during head flexion extension in sagittal plane Fig. 9. Results of cervical vertebra rotation during head side movement in frontal plane system. Nowadays various advanced techniques offer the possibility of carrying out examination during human activity. Some examples of the results of cervical vertebra kinematics analysis of head movement in sagittal and frontal planes (one adult man examined) are presented in figures 8 and 9. In order to validate human cervical spine models, information about real object is indispensable. Typical model is verified by comparing kinematical parameters obtained from numerical simulation and from tests on human body. Rotation of cervical vertebrae presented above could be useful for models validation. Use can be made of functional computed tomography in order to validate the models of human motion organ. This validation is based on the latest achievements in medical technique. The present research should be continued which allows average kinematical parameters to be determined for male and female spines on the basis of a representative sample of people. 5. Conclusions Such parameters as stiffness or elastic modulus, physiological cross-section area of muscles and vertebra kinematical parameters are required for a mathematical modelling. The analysis of male and female cervical spine stiffness revealed a similar spine response to torsion in

54 M. GZIK et al. horizontal plane, the others characteristics showed that male spine is stiffer and transmits greater loads. The anatomical construction of human cervical spine restricts in a special way the movement in frontal plane. The side bending of head activates most effectively neck muscles. Six anterior longitudinal ligaments and discs were tested during the experiments. The ligaments are especially active during strip elongation, while the discs during tension and compression. A biomechanical model design is connected with some simplified assumptions. The characteristic of ligaments proves that linearization of the function describing their response is appropriate for a physiological range of the elongation (up to 6 mm). The same statement made to the disc does not correspond with the facts. The disc response to tension and compression should be treated as nonlinear. Due to advanced biomedical technique we have faced some new possibilities of determining physical tissue parameters. Up to now physiological crosssection areas of muscles were determined on the basis of MRI scanning in one intersection plane. Thanks to 3D Fiesta module of MRI it is possible to frame each muscle in the space and then to measure its geometrical parameters. The method of physiological cross-section areas allowed the main neck muscles to be determined in five women and five men. The results prove that in many cases the same muscles have not the same geometrical parameters. This means that the assumption about symmetrical to middle sagittal plane neck response is false. The differences were observed especially in elderly people, which is connected with the degeneration of facet joints and discs. Validation is an important part of model building. In the paper, new techniques of measuring some kinematical parameters during physiological activity were presented and proposed as a way of validating the model of human organ motion. Comparison of the results from numerical simulation and tests on real object makes the success in biomechanical modelling more spectacular. The new methodology of experiments can contribute to the creation of much more realistic models which prevent neck injuries or improve surgical treatment technique. Acknowledgements The research was supported by the Polish Ministry of Science and High Education, project no. 4 T07B 01730. References [1] BĘDZIŃSKI R., Biomechanika inżynierska zagadnienia wybrane, Oficyna Wydawnicza Politechniki Wrocławskiej, Wrocław, 1997. [2] BOCHENEK A., REICHER M., Anatomia człowieka I, Wydawnictwo Lekarskie, PZWL, Warszawa, 1990. [3] CONLEY M.S., MEYER R.A., BLOOMBERG J.J., FEEBACK D.L., DUDLEY A.A., Noninvasive analysis of human neck muscle function, Spine, 1995, Vol. 20, No. 23, 2505 2512. [4] GZIK M., Biomechanika kręgosłupa człowieka, Wydawnictwo Politechniki Śląskiej, Gliwice, 2007. [5] GZIK M., Modelling of human spine and biomechanical analysis of correlations between human body movement and internal forces, Material of International Conference RRS 2007, Road Safety and Simulation, Rome, 2007. [6] KAMIBAYASHI L.K., RICHMOND F.J.R., Morphometry of human neck muscles, Spine, 1998, Vol. 23, No. 12, 1314 1323. [7] MYERS B.S., MCELHANEY J.H., NIGHTINGALE R., Cervical spine injury mechanisms, P-276, Head and Neck Injury, Society of Automotive Engineers, Warrendale, 1994. [8] PANJABI M.M., CHOLEWICKI J., NIBU K., GRAUER J., BABAT L.B., DVORAK J., Critical load of the human cervical spine: an in vitro experimental study, Clinical Biomechanics, 1998, Vol. 13, No. 1, 11 17. [9] PANJABI M.M., CRISCO J.J., VASAVADA A., ODA T., CHOLEWICKI J., NIBU K., SHIN E., Mechanical properties of the human cervical spine as shown by three dimensional load displacement curves, Spine, 2001, Vol. 26, No. 24, 2692 2700. [10] PANJABI M.M., MYERS B.S., Cervical spine protection. Report, prepared for NOCSAE, 1995. [11] SEIREG A., Biomechanical analysis of the musculoskeletal structure for medicine and sports, Hemisphere Publishing Corporation, New York, 1989.