OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL 4-2011

Similar documents
VACUUM CLEANER INSTRUCTION MANUAL

Safety, Operation and Maintenance Manual with Parts List

User Guide. Bagless Cylinder White. Get Cleaning... vax.co.uk. Vax Careline: (UK) (ROI) White series

Wessel-Werk EBK 360. Electric Power Nozzle. Operating Manual Wessel-Werk GmbH Im Bruch 2 D Reichshof Germany

Wessel-Werk EBK 340. Electric Power Nozzle. Operating Manual Wessel-Werk GmbH Im Bruch 2 D Reichshof Germany

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

HYLA NST Cleaning System

EBK 340 / EBK 341 Electric Power Nozzle

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

The Storm 20-Gallon Wet/Dry Vac

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Multifunction. vax.co.uk Series. What s your Vax model number?

Customer Support

Meaco 30L and Meaco 40L dehumidifier instruction manual

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

IMPORTANT SAFETY RULES TO FOLLOW

Dehumidifier Users manual. For Models: DH45S DH65S

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

INFRARED QUARTZ WALL HEATER

- 2 - IMPORTANT SAFETY REMINDERS

100 Series Maxi Internal Filters. Instruction Manual

20 GALLON WET DRY VACUUM

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Operating instructions in the back. PD1020L

You're reading an excerpt. Click here to read official BH FITNESS T1 BASIC user guide

AerAtron. Ceiling fans

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Portable Air Conditioner

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Bagless Upright. vax.co.uk. What s your Vax model number?

AerAtron. Ceiling fans

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

GenStore Archive Cabinet

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.


Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Use and Care Manual. Model CPA12KH AIR CONDITIONER

car + boat Box Contents x2 x _DC16_CAR_BOAT_OPSMAN.indd 1 29/7/08 15:27:01

Ceiling Fan Installation Instructions

Split Type Room Air Conditioner. KSWM units

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Carpet Shampooer 700w Max Power

PROFESSIONAL SILK CERAMIC HAIR DRYER USE & CARE MANUAL PLEASE READ PRIOR TO USE 2400 WATTS SILK CERAMIC GRILLE 5 YEAR WARRANTY AC9096AU

LUCCI AIRFUSION QUEST II CEILING FAN

ClearView 100. Instruction Manual

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

USER S MANUAL HSC-24A

15GAL STEEL OIL DRAIN WITH 110V PUMP

Electric Water Kettle

Quick Start Guide See Inside for Use and Safety Information

Installation Instructions

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Cambridge Electric Infared Fireplace User Manual

Get Cleaning... User Guide Vax Careline: (UK) (ROI) Carpet Washer. vax.co.uk. Rapide Ultra series

Tablet 30W Tablet 92W

Electric Egg Boiler. Instruction Manual. Model Number: AEB-917

VALET MACHINE WET & DRY 30LTR.

INSTALLATION & USER INSTRUCTIONS

Installation Instructions For Slider Casement Air Conditioners

Model 1756 Test Lead Kit

Remote Alarm Monitoring System

D I G I T A L C L A M

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

MIC-WKT and MIC-WKT-IR

Wine Cooler with Thermo-Electric Cooling & Heating Technology

B100. single-line business telephone

OPL BASIC. Dosing System for Professional Laundry machines. Contents

FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL

NV2410N NV2420N NV3610N NV3620N NV4820N NV4820CN NV7210N NW3620N NW4820N

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

2 YEAR WARRANTY S7200PAU USE & CARE MANUAL ADVANCED CERAMIC TECHNOLOGY. To register your product go to

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

MACBlower Model Number: MAC40R MAC60R MAC80R MAC100R. MAC120R MAC150R MAC 200R Serial #

PORTABLE AIR CONDITIONER

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Nilfisk Power e

Installation Guide 2010 BMW S1000RR Full Exhaust System


B150 Series Commercial Brewer. Direct Plumb Kit

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase

PA 03 basic device TECHNICAL DATA. English

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Ultrasonic support removal tank

SMART Board 8055i and 8055i-SMP

WASH FILTER REGISTER FOR YOUR FREE 5 YEAR GUARANTEE TODAY OPERATING MANUAL ASSEMBLY. click. click. click

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Garage Pro USER S GUIDE 18P0 SERIES. 3 Safety Instructions. Product View. Assembly 5-6. Operation 6-9. Maintenance and Care

Transcription:

OWNER S MANUAL th DRAINVAC ATOMIK PRINTED APRIL 4-2011

INTRODUCTION We take this opportunity to express our gratitude and extend our congratulations for your decision to purchase a Drainvac product. A judicious investment you will enjoy for many years. The Drainvac Atomik central vacuum cleaner is built with the best components available on the market. They are manufactured and tested at our plant by a qualified and specially trained staff. However some installation and operation procedures must be followed to insure maximum performance and to avoid needless service calls. Please read the following carefully. REGISTRATION You must register your Drainvac Atomik vacuum cleaner on our website at this following address (www.drainvac.com/registration) to cover your warranty. WARNING Please read carefully IMPORTANT SAFETY MEASURES the use of an electrical appliance, certain precautions most be followed, including the following. READ ALL INSTRUCTIONS BEFORE USING the Atomik. WARNING: To reduce the risk of fire, electric shock or injury. Disconnect all electrical sources located on the wall where the unit will be installed. Do not leave the appliance unattended when plugged. Unplug when not used, before maintenance and before the installation is complete. Turn off all controls before unplugging. Do not use the appliance if the plug or power cord is damaged. Return the unit to the distributor if its does not operate normally, has been dropped, damaged or was left outdoors. The cord should not be used as a handle or to pull or lift the unit. Do not put the unit on the cord, do not pinch the cord in the doorway while closing a door or pull on a corner of a wall or other sharp edges and keep it away from hot surfaces. Do not pull the cord to unplug the device, rather pull the plug. Do not touch the plug or appliance with wet hands. Do not modify the device or its parts. The installation of the device must be vertical. Do not use outdoors or near source of excess moisture. Never vacuum liquid, fuels or imflammables materials with your device. Do not use it in a place where there are such substances. Never vacuum ashes from your fireplace or your ashtrays. Never pick up substances that are burning or smoking. Use the product according to the guidelines in this instruction manual and use only the accessories recommended by the manufacturer. Do not let children play or use it without adult supervision. Extra care must be taken if children are close when using the device. Do not insert objects into any opening of the unit. Do not use if an opening is blocked and remove dust, lint, hair, etc.., which may impede the airflow. Be sure to keep fingers, hair, loose clothing away from openings and moving parts. Use extra caution when cleaning stairs. KEEP THESE INSTRUCTIONS "Must be plugged into a grounded outlet. See instructions for grounding." INSTRUCTION FOR GROUNDING This appliance must be grounded. In case of failure or breakdown, the circuit grounding provides a path of least resistance which reduces the risk of electric shock. The device comes with a cord equipped with a lead which insures grounding and a ground pin. The plug must be plugged into an outlet that is properly installed and grounded in accordance with applicable local codes and regulations. WARNING: a ground wire connected incorrectly presents risk of electric shock. Consult an electrician or a qualified service technician in doubt about the grounding. Do not modify the plug thats comes with the device, if it does not fit into the outlet, install a new outlet by a qualified electrician. Drainvac International Inc. 2006. declines all responsibility if you violate any of these guidelines. 1

ACCESSORIES Rotating carpet brush Hose cover 1 x Polyester filter & 3 x Dust bags by pck. (Choice with or without zipper) Activac 1 filter 1,2 or 3 inlet installation kit Dustpan installation kit Utility inlet Extra screws & wall hanger #1 screws ( 1.25-30mm ) All illustrations, specifications, colors and photographs shown may vary. While Drainvac International takes care to ensure that the information contained in this publication is accurate, it cannot guarantee complete accuracy. Drainvac International is not responsible for errors or omissions contained in this publication. 17

TOOLS REQUIRED Pair of pliers Pair of cutters Phillips screw driver (star) Flat screw driver 2.25 57 mm 0.5 12,5 mm Measuring tape Hole saw Hand drill Mitre box & saw or Pipe cutter 3

TROUBLE SHOOTING PROBLEM : The unit will not start 1 - Check the circuit breaker on your electrical panel. 2 - Check the circuit breaker of the unit. ( Image C1 ) 3 - Check the 24 volt circuit: To check the 24 volt circuit, proceed as follow ; - Establish the contact between the two ports of a wall mounted air inlet valve with a piece of metal (ex. coin ( Image D )). If the system starts, the suction hose is defective. See your dealer. - If the system does not start check the 24 volt wires on the unit ( Image C2 ); Establish the contact between the two screws of the 24 volts circuit plate using a piece of metal (ex. Screw driver ( Image E )). If the unit starts, the 24 volt wire is either cut OR unplugged from one of the wall mounted air inlet valves. - If the system still do not start after steps 1, 2 and 3, the printed circuit is defective. Call your dealer. PROBLEM : The unit will not stop Check the 24 volt circuit as follows ; - Disconnect one of the two 24 volt wires on the unit ( Image C2 ). If the unit stops, the two wires are in contact somewhere in the circuit OR a wall mounted air inlet valve is defective. If the unit does not stop, the printed circuit is defective. Call your dealer. NOTE : If you notice a vibration coming from the motor, call your dealer. IMAGE C 24 volt wire (2) Breaker (1) Coin IMAGE D IMAGE E 15

STEP 1 *** Remove the Drainvac Atomik vacuum cleaner and the equipment from the packaging.*** *** Open the vacuum cleaner before using.*** 1 - Detach the clamps, remove the lid and take off the plastic bag. (The plastic bag included equipment for the installation of the unit. Keep it near the unit). 2 - Make sure the polyester filter and dust bag are properly installed. 3 - Replace the lid on the unit and attach the clamps. 5

MAINTENANCE AND CLEANING PROCEDURE All mechanical systems require a minimum of maintenance, your system is not an exception. Beyond the occasional external cleaning, we recommend a complete inspection of the motor brushes after 500 hours of usage. (1000ft /100 m2 represents 1 hour of usage for each use). For a house approximately 2500 sq. ft./ 250 sq. m. On average, the frequency of inspection is once every 3 to 5 years. Also you must change the polyester filter & the dust bag periodically. This will stabilise the efficiency of the unit and will cut down from 5 to 6 times the maintenance of your unit. Cleaning procedure : 1 - Detach the clamps, remove the lid from the unit. 2 - Remove and discard the dust bag and the polyester filter. If you use a dust bag with a zipper, you can re-use it a few time all depending on the use (Image A). The misuse of this bag may invalidate the warranty. 3 - Install a new dust bag & polyester filter (Image B). You can install the zipper bag if the above conditions are respected. 4 - Reattach the lid to the main unit. Lid Image A Dust bag (With or without zipper) Polyester filter Image B Clamps Main unit * IF THE UNIT IS USED WITHOUT ITS FILTERS, THE WARRANTY WILL BE VOID. 13

MINIMUM SPACE REQUIRED TO INSTALL THE UNIT Front view Min.12 (30.5cm) Min.9 (22.75cm) Min.12 (30.5cm) Install the unit near an electrical outlet. 120 volt, 15amps 240 volt, 16amps Min.1 (2.5cm) Side view Min.18 (45.75cm) 7

INSTALLATION ON A PIPING NETWORK In a condo, in a garage, in a RV, in the mecanic room... Example : RV installation Power outlet 11 24 volt wire

INSTALLATION OF THE EXHAUST FILTER Activac 1 exhaust filter Flat screw driver Collar Collar 90 medium abs elbow Flat screw driver 9

OWNER S MANUAL *** Open the lid of the vacuum cleaner before using.***

WARRANTY Warranty covers any defect in material or workmanship produced by Drainvac International Inc. It excludes damage caused by normal wear and tear, misuse & modification. RESIDENTIAL *see conditions 5 years for : Motor - Parts - Casing - Labor 3 years for accessories * Conditions for the residential warranty : - Excludes motor brushes. - Labor at the dealer s store or plant. - Freight is at the customer s expense. - Must have purchase invoice. * Warning, the service call made by the dealer is at the customer s expense. COMMERCIAL *see conditions 1 year for : Motor - Parts - Casing - Labor 1 year for accessories * Conditions for the commercial warranty : - Excludes motor brushes. - Labor at the dealer s store or plant. - Freight is at the customer s expense. - Must have purchase invoice. * Warning, the service call made by the dealer is at the customer s expense. If you wish to speak to a service agent, please contact your retailer or Drainvac International Inc Monday to Friday from 9am to 4pm (eastern time) at : T : 1 800 408-1448 (450) 467-1448 F : 1 877 408-2225 (450) 467-2225 info@drainvac.com www.drainvac.com http://www.youtube.com/drainvacchannel 18

TABLE OF CONTENTS Tools required page 3 Equipment page 4 STEP 1 : Remove the unit from the packaging page 5 Unit dimensions page 6 Minimum space required page 7 Unit installation page 8 Installation of the Activac1 exhaust filter page 9 Installation, ready to use page 10 Installation on a piping network page 11 Electrical installation page 12 Maintenance & cleaning procedures page 13 WEEE directives page 14 Trouble shooting page 15 Kits A-B-C page 16 Accessories - Filters - Dust bags page 17 Warranty page 18 2

KITS ZIP1021 ZIPBROOM kit 20 (6m) extensible hose + tools, hose hanger and handle TGA30-6 Econo kit 30 (9m) regular hose + brush, tools kit, hose hanger & telescopic handle KIT130C DELUXE kit 30 (9m) on/off hose + brush, tools kit, accessory hanger & telescopic handle 16

EQUIPMENT Clamps Wall bracket Entry Exhaust Power cord North America 120V International 240V 24 volt On/Off button On I position Off O position GreenLED Breaker - Fuse North America 120V International 240V Activac 1 exhaust filter 2 x Dust bags (One without zipper & one with zipper) 8 (20cm) diam. Polyester filter PVC coupling Owner s manual 4 x collar Utility inlet 1 foot (30cm) 24 volt wire with connectors 90 medium ABS elbow 4 x #1 screws 4

WEEE DIRECTIVE This appliance has been assessed in accordance with the European Parliament Directive on Waste Electrical and Electronic Equipment, usually referred to as the WEEE Directive. The WEEE Directive requires that the appliance be disposed of at the end of its useful life an in environmentally responsible manner. Parts and materials should be re-used or re-cycled in order that the use of new resources and amount of waste going for landfill be minimized. The WEEE Directive stipulates that the supplier should collect the used item without cost to you. Please inform the supplier of your wish to have the old appliance collected when ordering the new replacement. If you wish to dispose of the appliance yourself, do not mix it with unsorted municipal waste. The crossed-out wheeled bin symbol on the unit label indicates this requirement. You must ensure that the appliance is disposed of at an authorized treatment facility. Details can be obtained from your local council. WEEE 14

UNIT DIMENSIONS Front view 9.75 (24.75cm) 15.5 (39.5cm) Side view 11 (28cm) 6

ELECTRICAL INSTALLATION The Drainvac Atomik vacuum cleaner is equipped with one electrical cord. An adequate electrical power outlet must be installed close to the unit. We strongly recommend installing an electrical circuit that will be used only by the unit. North American model : ATOMIK6 require an 15 amps/120 volt circuit. International model : ATOMIK60 require an 16 amps/240 volt circuit. Also plan the 24 volt between the unit, the piping system and the inlets. Type B Nema 6-15(220v) Type E Type G Type I 12

UNIT INSTALLATION How to install the unit? 1- Remove the wall plate that is attached to the back of the unit using the pair of cutters. Cut strap with the pair of cutters 2- Fasten the wall plate to the wall using the 4 x #1 screws included with the unit. #1 ( 1.25-30mm ) Phillips screw driver (star) Wall hanger 3- Lift the unit and install the top part (A) of the unit bracket behind the top part of the wall plate. At the same time, install the bottom part (B) of the unit bracket inside of the bottom part of the wall plate. A B 8

DRAINVAC ATOMIK, READY TO USE 1 2 x Collar Utility inlet PVC coupling Phillips screw driver (star) Flat screw driver 2 1 foot (30cm) 24 volt wire with connectors. 10