SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s. Manual



Similar documents
Speed-DSL 9.2 Ethernet connection over 8-wires up to 9.2 Mbit/s. Manual * * * *

Pan Dacom. Nets work together. SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s ( A, A) Manual

TNE1500-P and TNE1500-S Single Line T1 Network Extender Provider and Subscriber

TAM Port T1 Access Multiplexer

TNE1500-P and TNE1500-S T1 Network Extenders Installation Instructions

UIM-2T1 T1 Loop Bonding Uplink Interface Module

About the HotWire Slot Standalone Shelf

Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

LMR16TC Mini 10BASE-T Repeater. Installation Guide

Technical Support. Support Information

Power Over Ethernet Adapters POE101

FB-500A User s Manual

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide

Hotwire 5620 RTU Installation Instructions. Contents. Hotwire 5620 RTU Overview. Document Number 5620-A2-GN11-40 September 2001

Long Range Ethernet Extender

Gigabit eco-friendly Ethernet Switch AT-GS900/8. Installation Guide Rev. A

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual

Installation Guide for. 10/100 to Triple-speed Port Aggregator. Model TPA-CU Doc. PUBTPACUU Rev. 1, 12/08. In-Line

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

FSW-0505TX/0805TX 5/8 Port SOHO 10/100Mbps NWay Switch FSW-0505TX FSW-0805TX. 5/8 Port SOHO 10/100Mbps NWay Switch. User s Manual. (Revision 1.

InnoMedia ESBC B. Quick Install Guide. 1

ES-3305P V2 / ES-3308P V2. Quick Installation Guide / v1.0

8-Port PoE Network Switch

8-Port 10/100M N-Way Mini Switch

SHDSL LAN EXTENDER H301A. User Manual

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual

MoCA Adapter MC1001 v2 Installation Guide

MDI/MDIX) FEP-32008T-3

InnoMedia ESBC B. Quick Install Guide. 1

Installation Guide for. 10/100BaseT Port Aggregator Tap with Active Response. Models PA-CU-AR, PAD-CU-AR. Doc. PUBPACUARU Rev.

Product Documentation on the World Wide Web

User Guide. MC100CM MC110CS Fast Ethernet Media Converter. MC111CS MC112CS WDM Fast Ethernet Media Converter

Hotwire 6310 MVL Modem with Inline Phone Filter Installation Instructions. Contents. Hotwire 6310 MVL Modem Overview

palm Switch Port 10/100 Base-TX Switch with Auto MDI/MDI-X User Guide

Perle 10/100 Ethernet Media Converters

C24-CAMANL Video Server/Encoder

Nevco, Inc. Installation Manual

TP-LINK TECHNOLOGIES CO.,LTD. Website ADD FI.3,Bldg.R1-B.High-Tech Industrial Park,Shenzhen

VDSL Ethernet Extender AT-MC605. Installation Guide Rev. C

FCC COMPLIANCE STATEMENT

Quick Installation Guide. 16-Port 10/100Mbps Fast Ethernet Switch

User Guide TL-SG1016D 16-Port Gigabit Switch TL-SG1024D 24-Port Gigabit Switch

Chapter 9A. Network Definition. The Uses of a Network. Network Basics

10/100/1000 Base-T to Gigabit Fiber Media Converter

Energy Smart Electric Water Heater Controller

User Guide TL-SG1016/ TL-SG /24-port Gigabit Ethernet Switch

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

MICROSENS Media Converter 10/100/1000T to Gigabit Fiber

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

Perle 10/100/1000 Ethernet Media Converter Module

HP-1000E v2. User s Manual. Powerline Ethernet Adapter. HP1000E v2 User s Manual

Moxa EtherDevice Switch

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

Open Networking Adapter 1101GT Quick Install Guide

User's Manual. 8-Port 10/100Mbps with 4-Port PoE Fast Ethernet Switch FSD-804P - 1 -

BPM Series. Metered Rack Mount PDUs. Quick Start Guide. Models Covered:

4-CH Video Server SED-2310Q. Ver User s Manual

PRO 5000 CPE 1D Quick Installation Guide

TNE1544 and TNE1584 T1 Network Extenders Installation Instructions

16-Port and 24-Port 10/100 Switches

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

32-bit PCI 10/100/1000Mbps Gigabit Ethernet Card. User s Guide. FCC Warning. CE Mark Warning. VCCI Warning

Network Design. Yiannos Mylonas

4-Port Switch. 10/100/1000 Mbps Gigabit Ethernet GS104. Installation Guide

N560 series H/W Installation Guide

9,'(2 #6(3$5$725 8VHU V#0DQXDO

Ethernet Radio Configuration Guide

INSTALLATION GUIDE ConnectLine TV Adapter Getting started

Digital Library Assistant Model 701

GEU Port Gigabit Switch

USB Mini Print Server PS121. Installation Guide

DES-1005P 5-Port 10/100Mbps with 1-Port PoE Unmanaged Switch

10BASE-T/100BASE-TX & 100BASE-FX 2-Port Bridging Media Converter

FlexDSL MiniFlex. SHDSL.bis Up to 30Mbps Ddd. Ethernet. Features. Possible Applications

5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105

MCR1900 Media Converter 19-Slot Chassis

9,'(2 #6(3$5$725 8VHU V#0DQXDO 96043;

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

IFS SP-PoE Splitter User Manual

EPSON USB/Parallel Adapter User s Guide

USB Dual Handset Adapter for Nortel 1100-Series IP Phones

WPR400 Wireless Portable Reader

PoE+ Extender Switch User's Manual. Rev W

USB/VGA Cat 5 UTP Console Extender

Contents. Section A Networking Basics Learning the Basics Section B Wired Ethernet Networking... 17

HP NC7170 Dual Port PCI-X 1000T Gigabit Server Adapter User Guide. June 2007 (Second Edition) Part Number B

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

Transcription:

Ethernet connection over 2-wires up to 2.3 Mbit/s Manual

Notes Before installing and putting the device into operation, please read the security guidelines at the end of this documentation! Pan Dacom Direkt would like to point out that the information and notes contained in these documents are subject to technical changes. In particular, changes resulting from the continuing development of the products may not have been taken into account. Pan Dacom Direkt does not assume liability for print errors contained in this manual or other inaccuracies. Pan Dacom Direkt explicitly points out that this manual only contains a general description of technical processes and notes, and that their implementation as described is not necessarily sensible in every individual case. In case of doubt, it is essential to confer with Pan Dacom Direkt. This manual may not be copied, in whole or in part, or translated into other languages, without the written consent by Pan Dacom Direkt. by Pan Dacom Direkt GmbH SPEED-DSL 2.3/22.10.2004 page 2

x SPEED-DSL 2.3 CAUTION Pan Dacom Direkt GmbH strongly recommends the use of proper electrostatic discharge (ESD) precautions when handling this equipment. 1. Installation 1.1. Unpack and inspect the equipment. The following components should be included 1 SPEED-DSL 2.3, SPEED-DSL 2.3-Q or SPEED-DSL 2.3-G 1 power supply 1.2. Power up the SPEED-DSL 2.3 Plug the power supply into the back of the SPEED-DSL 2.3 and connect it to the power source. Verify that the Power LED on the front of the SPEED-DSL 2.3 is illuminated. Power Adapter Configuration Ethernet Connection 5V DC SDSL Connection SPEED-DSL 2.3 Available Power Collision Rx Tx Lnk SDSL Connection Ethernet Connection NOTE Upon start up, the Ethernet link will remain disabled (as indicated by solid illumination of the Ethernet Rx, Tx, and Lnk LEDs) until the SDSL connection has been established. SPEED-DSL 2.3/22.10.2004 page 3

1.3. Configure the SPEED-DSL 2.3 Configuration switches for the SDSL port are on the back of the SPEED-DSL 2.3, numbered from left to right, 1-4. Power Adapter Configuration Ethernet Connection 5V DC SDSL Connection 1.3.1 Bandwidth Switches 1-3: SPEED-DSL 2.3-P and SPEED-DSL 2.3-Q ONLY Switches 1-3 on the SPEED-DSL 2.3-P and SPEED-DSL 2.3-Q work in tandem with one another to provide eight bandwidth options for the SDSL port. Distance capabilities listed in the following tables assume the use of 26 American Wire Gauge (AWG) cable. Connections made with cable of a lesser gauge (e.g., 24 AWG) will link up at greater distances. Your SPEED-DSL 2.3 may not link up if the cable is in poor condition or if the cable distance is greater than a particular bandwidth will support; if link IS acheived under such conditions, traffic quality may be affected (e.g., packets may be dropped) SPEED-DSL 2.3-P BANDWIDTH AND DISTANCE OPTIONS Switch Position 1 2 3 Bandwidth Distance (kbps) Feet Meters down down down 2,320 11,000 3,353 down down up 2,064 11,900 3,627 down up down 1,552 12,600 3,840 down up up 1,040 15,500 4,724 up down down 784 16,000 4,877 up down up 528 17,900 5,456 up up down 400 18,900 5,761 up up up Adaptive* varies varies SPEED-DSL 2.3-Q BANDWIDTH AND DISTANCE OPTIONS Switch Position 1 2 3 Bandwidth Distance (kbps) Feet Meters down down down 2,320 10,400 3,170 down down up 2,064 10,800 3,292 down up down 1,552 13,400 4,084 down up up 1,040 14,800 4,511 up down down 784 15,800 4,816 up down up 528 17,400 5,304 up up down 400 18,200 5,547 up up up 272 19,200 5,852 *Adaptive mode allows the SPEED-DSL 2.3-P to train up to the best possible speed supported by the SPEED-DSL 2.3-P, the remote modem to which it's connected, and the copper cable pair connecting the two. The maximum reachable distance for an SPEED-DSL 2.3-P in Adaptive mode is 24,700 feet (at 144 kbps). The SPEED-DSL 2.3-Q does not have Adaptive capability. NOTE Bandwidth cannot be configured on the SPEED-DSL 2.3-S or SPEED-DSL 2.3- Q; subscriber units determine bandwidth via communication with their partner SDSL provider unit. SPEED-DSL 2.3/22.10.2004 page 4

1.3.2 Ethernet Duplex Mode Switch 4: SPEED-DSL 2.3-P, SPEED-DSL 2.3-S, SPEED-DSL 2.3-Q The Ethernet link can be configured at either Full Duplex or Half Duplex mode. Although both ends of the ETHERNET connection must have the same duplex mode configuration, it is not necessary for partner providers and subscribers to be configured the same; duplex mode does not apply to the SDSL link. SWITCH 4 down up CONFIGURATION Half Duplex Full Duplex 1.3.2.1 Half Duplex Ethernet Receive and transmit functions are mutually exclusive; data transmission occurs in only one direction at a time. Packet collisions are not unusual. 1.3.2.2 Full Duplex Ethernet The Ethernet line can receive and transmit simultaneously, effectively upping aggregate bandwidth from 10 mbps to 20 mbps and preventing packet collisions. 1.4. Connect the SDSL Line. Plug your SDSL cable into the SDSL RJ45 port on the back of the SPEED-DSL 2.3. Verify the connection: the SDSL Connection LED on the front of the SPEED-DSL 2.3 will pulse green to indicate the connection is established and operational. SPEED-DSL 2.3 Power Adapter Configuration Ethernet Connection 5V DC SDSL Connection Available Power Collision Rx Tx Lnk SDSL Connection Ethernet Connection Link up time between local and remote SDSL network extenders can vary from one to five minutes depending on the quality, gauge and distance of the copper cable. If cable distance is greater than a particular bandwidth will support, the units may not link up or, if they do achieve link, traffic quality may be affected (e.g., packets may be dropped). SDSL RJ45 PORT PIN CONNECTION 1 not used 2 not used 3 not used 4 Ring 5 Tip 6 not used 7 not used 8 not used SDSL CABLE: RJ45 CONNECTOR SPEED-DSL 2.3/22.10.2004 page 5

1.5. Connect the Ethernet Line Plug the Ethernet cable into the Ethernet Connection RJ45 port on the back of the SPEED- DSL 2.3. Verify the connection: solid illumination of the Ethernet Connection Lnk LED on the front of the SPEED-DSL 2.3 indicates a link has been established, IF an SDSL connection has already been made. If an SDSL connection has NOT yet been made, the Ethernet link will remain disabled (as indicated by solid illumination of the Ethernet Rx, Tx and Lnk LEDs) until the SDSL link has been established. SPEED-DSL 2.3 Power Adapter Configuration Ethernet Connection 5V DC SDSL Connection Available Power Collision Rx Tx Lnk SDSL Connection Ethernet Connection ETHERNET RJ45 PORT PIN CONNECTION 1 Rx+ 2 Rx- 3 Tx+ 4 not used 5 not used 6 Tx- 7 not used 8 not used ETHERNET CABLE: RJ45 CONNECTOR NOTE For most applications, the SPEED-DSL 2.3 connects to a PC using a straightthrough Ethernet cable and to a hub or a switch using a crossover Ethernet cable. For any other connection combinations you must verify the pinout of the Ethernet device into which you are connecting the SPEED-DSL 2.3 in order to determine which type of cable is required. SPEED-DSL 2.3/22.10.2004 page 6

2. Additional Information 2.1. LED Indicators LED State Indication Additional Information Power solid green unit is operational If the Power LED is not illuminated, it is unlikely the SPEED-DSL 2.3 is receiving power and therefore none of the LEDs will be illuminated: Available SDSL Connection pulsing green solid green SDSL connection is established and active problematic SDSL connection Traffic is flowing A connection exists but there is indication of a problem with the SDSL line. no illumination no SDSL connection When the SDSL connection is lost, the Ethernet LEDs will present as follows (see NOTE on following page): Ethernet Collision no illumination standard Either there is no traffic or traffic is flowing without any collisions. When there is no Ethernet connection, the Ethernet Collision LED will remain unlit by default. flashing red packet collision The Ethernet packet(s) will automatically be retransmitted. NOTE: An SPEED-DSL 2.3 in Full Duplex mode does not have collisions; the Ethernet Collision LED is only applicable in Half Duplex mode. solid red warning There is a potential traffic problem over the Ethernet segment. SPEED-DSL 2.3/22.10.2004 page 7

LED State Indication Additional Information Ethernet Rx flashing amber Ethernet activity The SPEED-DSL 2.3 is receiving data from the Ethernet network. no illumination no activity Either there is no Ethernet link or a link exists but there is no activity. OR solid amber heavy Rx traffic The SPEED-DSL 2.3 is receiving large amounts of data from the Ethernet network. A solid amber Ethernet Rx LED can also signify a lost SDSL connection when presented as follows (see NOTE on following page) Ethernet Tx flashing amber Ethernet activity The SPEED-DSL 2.3 is transmitting data to the Ethernet network. no illumination no activity Either there is no Ethernet link or a link exists but there is no activity: OR solid amber heavy Tx traffic The SPEED-DSL 2.3 is transmitting large amounts of data across the Ethernet network. A solid amber Ethernet Tx LED can also signify a lost SDSL connection when presented as follows (see NOTE on following page): SPEED-DSL 2.3/22.10.2004 page 8

LED State Indication Additional Information Ethernet Lnk solid green Ethernet connection is established A solid green Ethernet Lnk LED can also signify a lost SDSL connection when presented as follows (see NOTE on following page): no illumination no Ethernet connection The Ethernet Rx and Tx LEDs will remain unlit by default. (A pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks at a more rapid, less constant rate.) NOTE If the SDSL connection loses link, the Ethernet connection will automatically be disabled (as indicated by solid llumination of the Ethernet Rx, Tx and Lnk LEDs). Upon reestablishment of at the SDSL link, the Ethernet connection will be reinstated and the Ethernet LEDs will reflect current Ethernet status. SPEED-DSL 2.3/22.10.2004 page 9

2.2. Regulatory Compliance 2.2.1 FCC Regulatory Compliance Information for Class A Equipment This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by the manufacturer. If the equipment includes a ferrite choke or chokes, they must be installed per the installation instructions. 2.2.2 Industry Canada Regulatory Compliance Information for Class A Equipment This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment regulations. Cet appareil numérique de la classe A respecte toutes les exigences du réglement sur le matérial brouilleur du Canada. SPEED-DSL 2.3/22.10.2004 page 10

Pan Dacom Networking AG GS Nord Merkurring 105 22143 Hamburg Tel.: 040-679447-0 Fax: 040-67944750 GS West Schiess Straße 55 40549 Düsseldorf Tel.: 02131-17058-0 Fax: 02131-1705880 GS Ost Germania Bogen Multimedia-Center 12099 Berlin Tel.: 030-7508-3500 Fax: 030-7508-3535 GS Mitte/Zentrale Robert-Bosch-Straße 32 63303 Dreieich Tel.: 06103-932-0 Fax: 06103-932400 GS Südwest Kurze Straße 40 70794 Filderstadt Tel.: 0711-7705506-0 Fax: 0711-77055070 GS Süd Inselkammerstraße 10 82008 Unterhaching Tel.: 089-614478-0 Fax: 089-61447850 Technical Hotline 06103 932 100 Fax: 06103-932 413 dispatch@ffm.pandacom.de SPEED-DSL 2.3/22.10.2004 page 11

*220-0000086* *220-0000086* SPEED-DSL 2.3/22.10.2004 page 12