ROOFS, SNOW AND ICE DAMS



Similar documents
Preventing Ice Dams on Roofs

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

CONDENSATION IN REFRIDGERATED BUILDINGS

Assessing the effect of attic moisture in wood framed multi-unit row housing blocks.

Retrofitting an Insulated Cold Roof

Attic condensation during winter can

solutions & tips six Wise Energy Guide Building envelope solutions and simple tips AIR SEALING

CertainTeed. Protecting Your Home From Ice Dams Homeowner s Guide

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

Basements are Changing. Basements Part of the Enclosure. Basements. Energy Efficient, Durable, Healthy. Below grade enclosure

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Signs of insulation problems In the winter. In the summer. conditioning system

Selecting Energy-Efficient Windows

Ventilation for Cathedral Roofs: How Much Is Sufficient?

2014 British Columbia Building Code Changes

Best Practices for Crawl Space Insulation

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

Asphalt Shingle Application Requirements

HVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades

Insulating Unvented Attics With Spray Foam

Water Management & Damage Prevention:

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Roofing Signs that Your Roof Needs Repair/Replacement

HVAC INSTALLATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings

EcoTouch Insulation with PureFiber Technology

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

Foundation. Foundation

ABSeam Panel Overview and Installation Instructions

Condensation Fact Sheet METAL BUILDING MANUFACTURERS ASSOCIATION

ELIGIBLE REPAIR PROJECT PARAMETERS

High R-Value Does Not Always Mean High Performance

Home Performance with ENERGY STAR. Evaluation Report

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

Shingle Roofing: What s below the surface is important

INSTALLATION INSTRUCTIONS FOR MINERAL FIBER BATTS

Ice Dam Answers. from a National Expert. Ice dams cause millions of dollars of property damage across

The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A

CHAPTER 7: Building Systems ROOFING SYSTEMS

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

More Bang for Your Buck: Combining Thermal, Air and Water Barrier

Renovating Your Basement

Moisture-Safe Unvented Wood Roof Systems

Center for Energy Education Laboratory

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

CLOSED CRAWLSPACES. Have you ever been in your crawlspace? If not, have you ever even

The world of the roofer is changing. by Tony Woods

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money

keep moisture in check by getting fairly hot and facilitating downward time the sun came out, Then, after installation roof no longer got very

Basic B.S. (building science) insights for. Spray Foam, HVAC and Moisture

research highlight Highly Energy Efficient Building Envelope Retrofits for Houses

How To Repair A Boat Landing Deck With A Boat Bed

Home inspectors are not mold inspectors, however they do inspect for defects that

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers

IECC Compliance Guide for Homes in Virginia

HERITAGE WOODGATE LAMINATED ASPHALT SHINGLES Dallas, TX

) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.

HOW TO INSULATE CATHEDRAL CEILINGS

CHAPTER 5: INSULATION: MATERIALS AND TECHNIQUES

Waterproofing and interior insulation for basements takes new twist in technology.

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

SHINGLE APPLICATION GUIDE

BEST 2 WB 3 4 SIX WAYS FOR CONDENSATION IN BUILDINGS. Wagdy Anis, FAIA, LEED ap*

Mark Cramer Inspection Services, Inc.

Zen House. A Case Study on Design, Construction and Cost/benefit Analysis of a High Performance Home. Presentation for Net Zero Networking & Exchange

Non Invasive Roof Leak Detection Using Infrared Thermography

Molds and mildew are fungi that grow

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

CITY PLAN REVIEW AND INSPECTION. Lisa Fleming Brown, CPM

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

Comment Form on Proposed Gut Rehabilitation Alternatives

Residential Roofing Guide

Field Performance of Different Interior Basement Insulation Systems

Excerpts from the Canadian National Building Code (NBC)

Sun Windows General Information Sun New Construction Window Installation Instructions

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

BUILDING IN ALASKA HCM-00952

Window Sill Details for Effective Drainage of Water

Heating Load Calculation

The Optimum Basement Wall

CONTENTS. General conditions 2. Material requirements 3. Terms 4. Estimating shingle requirements 4. Roof preparation 6. Shingle application

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

Minimizing Water Intrusion Through Roof Vents in High-Wind Regions

Transcription:

ROOFS, SNOW AND ICE DAMS The Problem Ice dams are a common roof performance problem in cold climate buildings. Simply put, they are ridges of ice and icicles caused by melt water from further up the roof re-freezing lower on the roof. The dam created by the ridge of ice along the eaves can trap further meltwater and result in significant leakage under and through the roofing, especially shingles and metal roofing. This leakage can cause damage to the sheathing, the roof structure, or the ceiling and walls below. Large icicles along the eaves can become a danger to people below if they fall. 3. Snow melts and runs down roof 1. Snow insulates roof membrane 4. Cold air removes heat from underside 5. Ice dam and Icicles Form Water Leakage Figure 1: Ice Dam at a Typical Roof The Causes The fundamental causes of ice dams are well understood. If part of a roof becomes warm enough to melt snow that is lying on the roof, the snow will melt, and water will run down a sloped roof. If the water subsequently encounters a cold surface, the water will revert to ice. Therefore it can be said that the cause of ice dams is a difference in temperature on the roof surface where the upper part of the roof is warmer than the lower. Most explanations of why ice dams form are actually explanations of why the roof becomes warmer in one spot than another spot lower down. There are several reasons, and most can be a practical cause in a particular case. Often a combination of mechanisms causes the differential temperature. The most common causes, in no particular order, are: 1. insufficient insulation or thermal bridging 2. air leaking into the space below the roof membrane 3. a source of heat in roof such as a poorly insulated duct, hotwater piping, etc. BuildingSolutiuons.ca 1 J. F. Straube 2002

3. S n o w m e l t s a n d r u n s d o w n r o o f 4. C o l d a i r r e m o v e s h e a t f r o m u n d e r s i d e 5. I c e d a m a n d I c i c l e s F o r m 1. S n o w i n s u l a t e s r o o f m e m b r a n e 2. L o w t h e r m a l i n s u l a t i o n l e v e l s a l l o w s h e a t t o f l o w t o r o o f s h e a t h i n g 4. a difference in snow thickness, especially when combined with solar radiation. The cause and some solutions to each will be examined below. Cause: Insufficient Insulation If there is insufficient insulation between heated space and the roof sheathing, significant amounts of heat can flow to the underside of the sheathing. Snow also insulates the roof membrane, increasing its temperature. This scenario will raise the temperature of the roof-snow interface above the melting point even at cold outdoor temperatures. The result is many hours of snow melting with sufficiently low temperatures to ensure rapid freezing (Fig 2). Figure 2: The Process of Ice Dam Formation Caused by Poor Insulation The greater the snow depth on a roof (which is a function of the snowfall, the slope and friction of the roof, and the weather elements that encourage evaporation), the more its insulating effect on the roof membrane. For the same amount of insulation on the inside, an increase in snow depth will increase the temperature at the interface between the snow and the roof. Once enough snow has been accumulated, melting will begin. Once the meltwater reaches the eaves, the heat loss from the underside of the eaves and the fascia ensures that the water refreezes. Even when enough insulation is specified, problems arise where heat flow through large framing members and compressed insulation at truss heels results in lower installed R-values. Solution: Better Insulation / Ventilation The more insulation provided on the interior the more unlikely it is that enough snow will collect to cause melting. How much insulation is enough? The amount depends on the snowfall and the climate of course, but this author recommends a minimum of R20 be provided below ventilated attic www.buildingsolutions.ca 2 J. F. Straube 2002

roof membranes, R30 below ventilated cathedral ceilings, and R40 below unventilated cathedral ceilings. These insulation levels should be increase for severe cold climates (over 8000 HDD). Another way to keep the sheathing cold is to ventilate with outdoor air (Fig 3). Although ventilation will remove some of the heat the passes through the ceiling, very low levels of insulation and thermal bridging cannot practically be offset by ventilation. Ventilation is best used as a supplement to good insulation ventilation can be used to remove the little heat that flows through a well insulated roof. Ventilation of cold air removes the little heat that passes through Snow insulates roof membrane High and uniform insulation prevents heat flow to underside of sheathing Figure 3: Solutions to Poor Insulation Better framing practises and high-heel trusses can be used to reduce the liklihood of local area of poor thermal performance. Alternatively, in cathedral ceilings for example, adding exterior rigid insulation to the framing members (but below any ventilation) can be used to blunt thermal bridges. Cause: Air Leakage Warm air leaking through the ceiling plane or air from pressurised space-conditioning ducts bypasses the thermal insulation installed and will directly increase the temperature of an attic space or the underside of the membrane. Not only does air leakage into the roof cause warming and melting of snow, in colder weather it often causes condensation on the underside of the roof sheathing. The two processes combined can cause serious wetting and decay of the sheathing and roof structure as well as leakage into the space below (Fig 4). www.buildingsolutions.ca 3 J. F. Straube 2002

4. C o l d a i r r e m o v e s h e a t f r o m u n d e r s i d e 5. I c e d a m a n d I c i c l e s F o r m 3. S n o w m e l t s a n d r u n s d o w n r o o f 1. S n o w i n s u l a t e s r o o f m e m b r a n e 2. A i r l e a k s i n c e i l i n g a l l o w s w a r m a i r t o f l o w t o r o o f s h e a t h i n g Plumbing stacks, recessed lights, chimneys, electrical service penetrations in partition walls, and attic hatches all can on their own, or in combination, allow sufficient air leakage into the ceiling space (cathedral or attic) to cause serious condensation and ice damming problems. Air leakage from ducts placed in the attic (a bad idea for many reasons) can also acts as a significant heat and moisture source and cause both condensation and snow melting. Figure 4: Ice Dam Formation Process Caused By Air Leakage Solution: Air Sealing Although the solution is rather simple to state, it is quite difficult to achieve in practise. Great care must be taken to seal the ceiling air barrier (often the poly vapor barrier is used as an air barrier or the drywall). Table 1 provides a list of air leakage locations and means to ensure they are sealed. Caulking can be used around small openings and gaps, but expanding polyurethane or acrylic foam should be used around openings more than about 1. For large openings, drywall can be used as the air barrier with taped or caulked joints used to complete the seal. Great care and attention to detail is essentially the only solution to air leakage, although expensive answers such as spraying the entire ceiling with expanding foam (NOT dense-pack cellulose, or blown in batts) can provide the required airtightness quite easily. Adding ventilation openings is likely to increase the problem by allowing the leaking air more easy access to the outdoors. In some cases, adding a very large amount of ventilation can help by diluting the moisture content of the leaking air and reducing its temperature. However, it is very difficult and bad practise to ventilate away gross air leakage. Once the majority of the air leaks have been sealed, ventilation may be beneficial. www.buildingsolutions.ca 4 J. F. Straube 2002

Table 1. Locations of Attic Air Leaks and Sealing Methods Leakage Path Sealing Method Attic hatch Weatherstrip, caulk, postive action latch, and insulate to min R20. Space Condioning Ducts Avoid any ducts in attic. Insulate to min R-20, seal boot to ceiling air barrier, and seal plenum shaft. Plumbing stacks Use expanding foam and/or caulking Chimney stacks Use drywall and high-temperature caulk. Plumbing penetrations Seal with caulking and/or foam Electrical penetrations Seal with caulking and/or foam Top plates Seal with caulking and/or foam Light fixtures Caulk boxes from below or add drywall box above and seal to ceiling air barrier. Recessed lights Build drywall box above or replace with rated airtight units Recessed ceilings Stuff with batt insulation, add rigid air barrier in form of drywall, seal to ceiling air barrier plane. Kneewalls, and split-level interfaces Add batt insulation on vertical walls, add drywall or taped rigid foam or sealed drywall. Perimeter and party walls Drill or punch block cores/framing cavities just above ceiling, then fill with expanding foam. Problem: Heat Sources in Roof Space If ductwork, hot-water piping, or any other source of heat is located above the majority of the ceiling insulation, it can act as a heat source. Solution: Insulate and Remove Locating heat sources above the insulation is bad practise, since it causes increased heat loss and energy consumption. If the sources are already there, adding a significant amount of insulation and an airtight blanket around them will reduce the source of heat dramatically. (Note: the addition of foil faced R6 insulation is NOT sufficient ductwork insulation in cold climates). As always, ventilation can be used to remove any residual heat that is not blocked by the insulation. Cause: Snow Thickness Variation Wind speeds are often higher near ridge lines and scour snow from the roof. Snow catchers at the base of metal roofs hold back sliding snow near the eaves. Exposed shingles or metal can easily be heated to 70 F (40 C) above ambient air temperature and cause melting of the snow immediately next to the exposed roofing. Water will run down the roof and can freeze at the eave, which is cooled from the underside (Fig 5). If the temperature is cold enough and the snowcover thin enough the melt water may form a relatively harmless thin sheet of ice below the snow. In other situations, large ice dams and icicles can form. www.buildingsolutions.ca 5 J. F. Straube 2002

1. Sun warms shingles were little or now snow cover exists 3. Snow insulates roof membrane 2. Snow melts and runs down roof 4. Cold air removes heat from underside 5. Ice dam and Icicles Form Figure 4: Ice Dam Formation Process Due to Uneven Snow Thickness Solution: Ventilation, Insulation, and Waterproofing Keeping the underside of the roof sheathing close to the exterior temperature is the best solution. This can be achieved by good ventilation and good insulation acting in concert. Even if all good design practises are followed this process can still occur. For this reason it is recommended that a waterproof membrane (preferably self-sealing to accommodate roofing nails) be provided. This membrane should come up the roof high enough to resist a 6 to 8 height of water above the edge of the wall insulation below (Fig 6). Hence, steep pitched roofs will require a narrower strips of this membrane than shallow roofs. Conclusions Differential temperatures below the roofing membrane cause ice dams. There are several causes of this temperature difference poor insulation levels, air leakage into the roof, heat sources in the attic, and solar heating of bare roofing. There are primarily two problems caused by ice dams water leakage and dangerous ice conditions. Some solutions solve one of these problems and some solve both. There are three broad strategies that can be used: 1. Stop excessive heat from flowing to the underside of roof 2. Remove the excessive heat by ventilation 3. Provide a waterproof roof membrane that will not leak under standing water and protect pedestrians from falling ice. www.buildingsolutions.ca 6 J. F. Straube 2002

In many cases a combination of strategies is used. Self-sealing membrane along eaves Ventilation of cold air removes the little heat that passes through >6" High and uniform insulation prevents heat flow to underside of sheathing Figure 6: Waterproof eaves-starter or Ice and Water Shield Blunting thermal bridges by providing full depth insulation and exterior insulation over the framing is the solution to poor insulation levels. The most common, most damaging, and often the most obvious problem to solve is excessive air leakage. Air sealing require care and attention to detail during design and construction. Removing ducts and pipes from the attic or at least insulating them well can control this source of accidental heat. Ventilation removes heat from under the roof membrane. Since ventilation cannot remove a lot of heat, it can usually only be used once the sources of heat have been removed or reduced drastically. If one can be sure of removing air leaks and thermal bridges, ventilation may be unnecessary. Finally, since the sun can cause some melting on exposed upper portions a roof, one typically needs to provide a layer of self-sealing waterproofing at the eaves of all sloped roofs. This provides some back-up protection in the event that other strategies are not perfectly implemented. www.buildingsolutions.ca 7 J. F. Straube 2002