Adsorption air dryers ADS 1 215



Similar documents
Kompressoren. Adsorption Dryer AD

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Atlas Copco Compressed air dryers. CD series Heatless adsorption dryer series HIGH QUALITY DRY AIR

ThermoSorb Desiccant Dryers

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Rotary screw compressors kw 5,5 7, , bar MODULO

Pro Dry Heatless dessiccant compressed air dryers

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

Quality air solutions. Refrigerant Dryers Adsorption Dryers Filters Oil-Water Separators Accessories

ECOCIAT. Domestic hot water heat recovery unit

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

ThermoStar Refrigeration Air Dryers

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

Refrigeration Air Dryers. Catalogue

Kompressoren. Oil Water Separators OWS

Externally Heated Desiccant Compressed Air Dryers PNEUMATIC PRODUCTS. PHD Series. pneumaticproducts-spx.com

ultrafilter HEATLESS HL Adsorption Dryer

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Compressed Air Filters

Medical Air Systems: Scroll

Concept WVM Brief description. Effi cient compressed-air adsorption dryer with vacuum regeneration. NEW! Now with improved ZDMC2

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators

clean and quiet dental

Refrigeration Air Dryers ADQ. Capacity: m 3 /h

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Refrigerated Air Dryers. Catalogue

Refrigeration Compressed Air Dryer Buran Ultrapulse

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

Screw Compressors 11-22kW

Compressed Air Filters KAESER FILTER Flow rate 0.60 to m³/min

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

OIL-FREE ROTARY SCROLL COMPRESSOR. ECOLIFE 1,5 15 kw

AIRROLLAIR COMPRESSORS E

On request of Akzo Nobel Dynamo Project Team we ve surveyed the energy efficiency of the compressed air system in the Barcelona Deco & A/AS plant.

Atlas Copco Quality Air Solutions. Compressed Air Filters

industry revolves around

Screw Compressors ESM Fixed Speed & VS Variable Speed

ultrafilter VARIOBLO Heat Regenerated Adsorption Dryer

From 6 litres 2 HP To 500 litres 10 HP

Atlas Copco Stationary air compressors

Compressor Service & Maintenance Manual

High Pressure Adsorption Dryer HLP PN 25, 0040 to 0125 HLP PN 40, 0050 to 0155

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Compressed Air and Gas Drying

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

High Pressure Dryer HLP-MSD 0055 to 0870, PN 100 to PN 400

Element D Services Plumbing

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

ROTARY SCREW COMPRESSOR. RMD kw

Rotary Screw Compressor. MSM MINI 2, ,5 kw

API Marine. BMS Presentation. Ballast Measurement Systems

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

COMBIMASS. Technical Data COMBIMASS eco-bio +

Workshop Compressors CLASSIC Series

Compact Air Solutions C Series kw Screw Compressors Want a 5. year warranty? Ask for details!

GenStore Archive Cabinet

Ultra-Filter. Compressed Air Filter. DF Series

Split units TH with hermetic compressors

Refrigeration Basics 101. By: Eric Nelson

Assisted lift operated 2/2-way solenoid valves Type EV250B

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

DRYPOINT RA REFRIGERATION DRYER RANGE

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Dehumidifier D 850E. - Instruction manual version 02

Series IDU/IDF. Refrigerated Air Dryer

SELECT SERIES DHA/CDA HEAT-LES DESICCANT COMPRESSED AIR & GAS PURIFICATION SYSTEMS. Value and Performance Through Advanced Technology

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

ZPA Heatless Regeneration ZHA Heated Regeneration ZBA Heated Blower Regeneration

Conlift1, Conlift2, Conlift2 ph+

ETC -SV. Class 0 oil-free compressed air through catalysis

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Dryaire Desiccant System

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Basic Hydraulics and Pneumatics

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Oil-Free Screw Compressors. Water-injected Technology. Rely on GD to provide the perfect fit

Direct steam injection humidifiers

UNITOR VACUUM cleaners

HeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance ( scfm models)

Solenoid valves 2/2-way direct-operated Type EV210A

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Modular Glovebox Systems Gas Purifier Units Antechambers Accessories

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

DUST EMISSION MONITORING SYSTEM

REFRIGERATED COMPRESSED AIR DRYERS

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Transcription:

Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE

COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that operates in an ambient temperature of 20 C and 70% relative humidity, takes in 2 gr of water for every Nm 3 of air. CONDENSATE DRAIN Compressed air is cooled at 30 C and condensed water vapour is separated, while 2.8 gr of water for every Nm 3 of air that condense can remain in the air (compressed at 0 bar as in the example) in vapour form. In the event of particularly rapid expansion and/or particular ambient conditions, compressed air for the application may be cooled to such an extent that the temperature drops below its Dew Point. If the temperature falls below its dew point (*), further condensation takes place resulting in separation of humidity and formation of condensate. (*) The Dew Point is the value of the temperature when we have the max. water vapour concentration in the air, at one specifi c pressure. Over time, this may lead to: - serious damage to the distribution network, the machines using the compressed air and the final product. - plugs of ice forming in the tubing in certain situations. COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 DRYING PROCESS D.P. 40 C Relative pressure 0 bar 0,0 grh2o/m3 AIR DISTRIBUTION 0 bar D.P. C Today compressed air is a primary and essential source of energy for most production processes, from small businesses to large industries. Filtered compressed air is no longer sufficient. Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Maintaining the correct dew point for compressed air ensures correct operation throughout the production process. Ceccato Aria Compressa S.p.A. has over 30 years experience in drying compressed air, and offers the optimum solution to satisfy any demand.

DRYING PROCESS +30 C 0 bar 2,8 gr/m 3 H 2 O +3 C 0 bar 0,5 gr/m 3 H 2 O +0 C 0 bar 0,48 /m 3 H 2 O 20 C 70% UR 2 gr/m 3 H 2 O The cooling process does not allow the temperature to fall below 0 C (solidification of water). However, specific applications or particular ambient conditions require dew point temperatures of below 0 C. Only adsorption dryers can achieve this, because condensate separation takes place WITHOUT lowering the temperature of the compressed air or gas. Principle Drying phase: Wet air from the compressors passes through inlet filter which removes the oil and enters in to tower A. The desiccant contained in it adsorbs the water vapor molecules. After a fixed (STD) or variable time (CD) the 3 way valve 2 deviates the airflow from tower A to tower B and it becomes the operative tower. P max *FPRE P max Regeneration phase: During the drying phase in the tower A, some dry air is deviated into the top of tower B, extracting the trapped water vapor from the desiccant material. During this phase, tower B is open to the atmosphere, allowing the purge air to expand. The silencers 3 on the outlet ensure quiet operation. **FMO atm. FMM A 2 B atm. Pressurization phase: 3 Once regeneration has taken place and tower B is pressurized, the 3 way valve 2 changes air flow again. Adsorbent material Unsaturated Saturated 3 Way valve Discharge silencer Prefi lters and Postfi lter Humidity detector (CD) Notes: * On ADS-0 outlet filter is built inside of the desicant cartridges. ** Recommended but not included on ADS-80.

ADS - 0 RANGE ADS 0 STD Compact execution Prefilter removes particulates and coalesced liquids from the air stream. Versatile installation with multiport system and six possible connections. Compact, reduced footprint, simple design. This module can be installed horizontally or vertically, can stand on the floor or be mounted on a wall (optional mounting kit available). The inlet prefi lter FMM is delivered loose with the dryer but it can be directly fixed on it. The outlet postfi lters FPRE are integrated in the dessicant cartridges. Aluminium head, base and cylinders prevent corrosion. Easy to maintain: - Maintenance operations can be performed without disconnecting tubing. - Assorbent cartridge with built-in postfilter. Automatic electronic control to manage the dryer and phase status with an automatic fault diagnosis, including alarms. Each tower is fitted with a high efficiency silencer for quiet operation. 2 Removable front panel allows for easy access for servicing without disconnecting the pipe system. 3 Postfilters, integrated in the dryer, removes particulate in the air stream. 4 Electronic control housed in an IP65 box, which enables: - regeneration cycle management - regulation status - dafault diagnonis - remote default report Multiport inlet and outlet; this arrangement ensures easy and fast installation. TECHNICAL INFO - Capacities from 4 up to 990 l/ at 7 bar. - Standard dew point - 40 C. (-70 C. by derating the FAD). - Max. working pressure bar. - Working pressure range 4 - bar. - Voltage: 2-24V DC 50/60Hz. : 00-5-230V AC 50/60Hz.

ADS 20-80 RANGE ADS 20-80 STD (CD: control dew point as option) Reliable operation with standard components tested for continuous service. The compact dryer can be installed on the floor (floor mounted kit as standard). The inlet prefilter FMM and the outlet postfilter FPRE, have to be mounted on the air distribution line. The filters are included but not pre-mounted. Base frame makes it easy to transport by fork lift. 2 Pressure gauge tower A. 3 Pressure gauge tower B. 4 Stainless steel purge nozzle. 5 Air outlet connection. 6 Air intlet connection. 7 High efficiency silencers with integrated safety valve. TECHNICAL INFO - Capacities from 0 up to 7800 l/ at 7 bar. - Standard dew point C. (-70 C. as an option together with derating the FAD). - Max. working pressure bar. - Working pressure range 4 - bar. - Voltage: 5-230V AC 50/60Hz.

ADS 0-25 RANGE ADS 0-25 STD: electronic timer control CD: control dew point Developed with high quality components, ADS dryers guarantee a stable dew point of C. The use of an optimized desiccant volume and a wide vessel, ensure a low air speed and a longer contact time. ADS/STD Purge phases are controlled by an electronic timer on the standard models (ADS/STD). There is also control dew point version (ADS/CD) where the drying phase is dew point dependent and is controlled by our electronic dew point management system. The two inlet prefi lters FMO-FMM and the outlet postfi lter FPRE have to be mounted on the air distribution line. The fi lters are included but not pre-mounted. Wide vessels for optimum air speed and reliable drying. Unit is rather low for its capacity due to flanges that are built into the vessels. 2 Air outlet connection. 3 Robust frame, including fork lift slots for easy installation. 4 Pressure Dew Point sensor (ADS/CD). 5 Pressure Dew Point digital display (ADS/CD). 6 Two manometers integrated in the control panel to show pressure in the vesse ls A/B. 7 Stainless steel purge nozzle. 8 Galvanized piping with flanged connections. 9 High efficiency silencers with integrated safety valve. 0 Air inlet connection. k Stainless steel 3 way valve long service interval. ADS/CD TECHNICAL INFO - Capacities from 0800 up to 200 l/ at 7 bar. - Standard dew point C. (-70 C. an option together with derating the FAD). - Max. working pressure and bar. - Working pressure range 4- bar and - bar. - Voltage: 230V AC 50/60Hz.

CONTROL DEW POINT - CD How to decrease your consumption? The electronic Pressure Dew Point control (CD) extends the drying phase of the dryer s cycle. It is done by measuring PDP of compressed air on the dryer outlet and only switching the columns when desiccant in the active tower is saturated. The regeneration part of the cycle stays fixed. As most of the time compressor and dryer runs < 00% load, this results in a significant extension of the drying time and a reduction in purge air consumption. Typically the extra investment in a Pressure Dew Point control is paid back in a few months by savings made on dryer running costs. Quality air with the ADS dryer Particularly for: The chemical and pharmaceutical Industries. Petrochemical plants. Food industry. Transportation of hygroscopic materials. Quality painting. Textile production. Semiconductors. Cable pressurization. Beer and drinks production. Applications in low-temperature environments. -20 C (..3*) Laboratories Painting Residual oil 0,0 mg/m 3 Residual particles < m C (..2*) Cold zones Instruments -70 C (..*) Arctic zones Semiconductors * Quality class according to ISO 8573- Original parts fit the best. Only they will guarantee the original performance of your machine.to ensure maximum working effi ciency and a long life time, every part must conform to specific technical standards. With the use of Original Parts you are certain about the quality, life time, utilized material and the impact on other components. All these aspects are important to make the right choice for spare parts. Only with original components can you be sure about these factors. Therefore your best choice is an Original Part.

PISTON COMPRESSOR from 25 to 500 L TECHNICAL DATA Type ADS ADS 2 ADS 3 ADS 4 ADS 7 ADS 0 ADS 20 ADS 24 ADS 27 ADS 36 ADS 42 ADS 55 ADS 60 ADS 80 ADS 0 ADS 30 ADS 80 ADS 25 Max. working pressure Operating pressure 2 Air treatment capacity Standard Dew Point FMO 0, m 0, mg/mc FMM 0,0 m 0,0 mg/mc FPRE m mg/mc bar psi bar l/ m 3 /h cfm C. Pre fi lters Post fi lter gas L W H Kg 4 8 282 426 708 990 0 2400 2700 3600 4200 5400 6000 7800 7 0 7 26 42 59 5 44 2 2 252 324 360 468 4, 5,9 0 5,3 24,7 34,7 67,7 84,8 95,3 27 48 9 22 275 FMM 0 FMM 0 FMM 0 FMM 0 FMM 0 FMM 0 FMM 20 FMM 20 FMM 33 FMM 33 FMM 60 FMM 60 FMM 60 FMM 85 FPRE 20 FPRE 20 FPRE 33 FPRE 33 FPRE 60 FPRE 60 FPRE 60 FPRE 85 3/4 3/4 3/4 ½ ½ 28 28 28 28 28 28 77 77 77 378 378 378 540 540 445 504 635 85 065 460 998 998 243 999 999 243 998 243 3 4 7 20 24 3 50 50 60 00 00 20 50 80 59 59 59 59 0800 3200 8000 200 648 7.080.296 38 466 636 763 2,5 2,5 2,5 2,5 2900 5900 200 25800 774 954.296.548 456 56 763 9 FMO 30 FMO 30 FMO 70 FMO 250 FMM 30 FMM 30 FMM 70 FMM 250 FPRE 30 FPRE 30 FPRE 70 FPRE 250 ½ ½ 2 2 960 960 064 8 754 754 833 859 7 7 832 869 445 445 600 650 INTEGRATED IN THE DRYER Inlet / outlet connections m m Dimensions W kg Weight Notes: Reference conditions: - Operating pressure: see the technical data table. - Operating temperature: 35 C. - Relative humidity: 00% 2 Filters are delivered loose with the dryer: ADS-0: the filters can be directly fixed on the dryer. ADS20-25: the filters have to be mounted on the air distribution line. For working pressure different from operating pressure use the correction factors table. H 6999002 TECHNE Correction factors Air Inlet Pressure - bar ADS up ADS 80 Correction factors Air Inlet Pressure - bar ADS0 up to ADS25 4 0,62 4 0,47 5 0,75 5 0,68 6 0,87 6 0,84 7 8,2 ADS/ bar 7 8, ADS/ bar 0,37 9,25 9,2 0,3,5,38 2,62 0,89 3,75 2,5 4,87 5 2 ADS/ bar 3 4,04, 2,2 5,9,24 W L Correction factors Air Inlet Temperature C. ADS up to ADS0 ADS20 up to ADS25 20,07 25,06 30,04 35 40 0,88 0,84 45 0,78 0,7 50 0,55 0,55 Correction factors Pressure Dew Point C. ADS up to ADS25-70 0,7 SOLD BY Designs manufacture, sales and service of air compressors, Air dryers and air fi lters www.ceccato.com