Pointe Scientific, Inc. Instrument Application



Similar documents
Pointe Scientific, Inc. Instrument Application

CTSC Clinical Laboratory. Clinical Laboratory Services CTSC. Clinical & Translational Science Center

MEDICAL NUTRITION THERAPY (MNT) CLINICAL NUTRITION THERAPY Service Time CPT Code

FS FSC. Abbreviations in common use. Fluid-stable, ready-to-use reagent. Fluid-stable concentrated reagent for measurement on Olympus AU systems

TEST DEFINITION LINEAR MODEL CALIBRATION DEFINITION TEST PARAMETER FILE : REAGENT DEFINITION REAGENT NUMBER 1 FOR TEST URICO

Room Temp: 8 Hr. Room Temp: 8Hr. Room Temp: ASAP. Refrigerated (2-8C): 3D. Room Temp: ASAP. Refrigerated (2-8C): 3D

CORMAY CONTROL SERUM HN CORMAY CONTROL SERUM HP

BIOCHEMISTRY DEPARTMENT

Unleash Your Potential

And Now, Presenting...

Case 2:10-md CJB-SS Document Filed 05/03/12 Page 1 of 5 EXHIBIT 12

AU 400 T H E V I S I B L E D I F F E R E N C E A N A L Y S E R S Y S T E M F O R C L I N I C A L C H E M I S T R Y

Discover Your Potential

CHEMISTRY. Updated Monday June 25, CHEMISTRY - BASIC PANEL * may be asked to fast for this test. Range M F 23-29

American Care, Inc SW 211 Street Miami, Florida Member Services:

Adams Memorial Hospital Decatur, Indiana EXPLANATION OF LABORATORY TESTS

Biochemistry Validation Form

Discover Your Potential

Georgia Northwestern Technical College Practical Nursing Program CLINICAL DAILY ASSESSMENT WORKSHEET FOR MODULES I-IV STUDENT: CLINICAL INSTRUCTOR:

cobas c 111 analyzer Small box. Big performance

Alison J. Farr, 1 Kathleen P. Freeman

Implementation Guide

Coding and Payment Guide for Laboratory Services. An essential coding, billing, and payment resource for laboratory and pathology services

PROFICIENCY TESTING. Clinical Laboratory Improvement Amendments (CLIA) DOs and DON Ts. Brochure # 8

Clinical Laboratory Parameters for Crl:CD(SD) Rats. March, Information Prepared by Mary L.A. Giknis, Ph.D. Charles B. Clifford, D.V.M., Ph.D.

Annex to the Accreditation Certificate D-ML according to DIN EN ISO 15189:2014

LABORATORY and PATHOLOGY SERVICES

Clinical Chemistry Line

OMG my LFT s! How to Interpret and Use Them. OMG my LFT s! OMG my LFT s!

Application of Sigma Metrics for the Assessment of Quality Assurance in Clinical Biochemistry Laboratory in India: A Pilot Study

Guide to Common Laboratory Tests for Eating Disorder Patients

Liver Function Tests. Dr Stephen Butler Paediatric Advance Trainee TDHB

GENERAL HEALTH SCREEN LAB REPORT. Date of Blood Draw: Time of Blood Draw: Fasting: Yes: X No:

SCOPE OF ACCREDITATION ISO 15189:2012. SPECTRA LABORATORY, INC. 525 Sycamore Drive Milpitas, CA Claude O. Burdick, M.D.

Laboratory Services Policy

Clinical Reasoning Case Study: I. Data Collection Chief complaint/history of Present Illness:

Why is a Comprehensive Metabolic Blood Chemistry panel included in the FNHP?

cobas c 311 analyzer

Certificate of Analysis NFKK Reference Serum X Components in Human Serum, Lot Number: NFKK2002a

Hepatitis C. Laboratory Tests and Hepatitis C

Creatine Kinase Assay Kit

Samsung POINT OF CARE Systems - Cardiac/Acute Care Biomarkers LABGEO IB Clinical Chemistry Analytes LABGEO PT

COBAS INTEGRA 400 plus

Comparative Pathology Laboratory Services List. Test Name Description of Services Specimen Requirement Notes

EXECUTIVE BLOOD WORK PANEL

Product List 2015 RIQAS IMMUNO A A CU SS SE A R Y R A S EA G Q E U N A R T EA S L G I E F T N O Y T R C S S O PE N C T I R FI O C L A S NALYSERS

Acute Pancreatitis. Questionnaire. if yes: amount (cigarettes/day): since when (year): Drug consumption: yes / no if yes: type of drug:. amount:.

Lab 2 Biochemistry. Learning Objectives. Introduction. Lipid Structure and Role in Food. The lab has the following learning objectives.

How To Use An Abaxis Alyzer

Basic Lessons in Laboratory Quality Control

I ALBP Albumin BCP X X19) X 19)

Bariatric Patients, Nutritional Intervention for

Creatine Kinase Activity Colorimetric Assay Kit ABE assays; Store at -20 C

Disclosures. Interpreting Liver Tests: What Do They Mean? Liver Function Tests. Objectives. Common Tests. Case 1

LIVER FUNCTION TESTS

RayBio Creatine Kinase (CK) Activity Colorimetric Assay Kit

HumaStar 100 HumaStar 200

How to Quickly and Easily Understand Your Blood Tests Without A Medical Degree. The Simplified Patient Reference Guide By Ronald J. Grisanti D.C.

MHDO CompareMaine Updated: 9/17/2015

The Medical Laboratory Licensing Regulations, 1995

UNDERSTANDING YOUR LAB TESTS

3240 Whipple Rd. Bunsenstr. 9-11

Albumin. Prothrombin time. Total protein

Directory of Laboratory Services st edition Contact Information

Application Sheet for Rivaroxaban (Xarelto ) Standard Range with. BIOPHEN Heparin LRT (#221011/221013) RUO

ph Alkalinity of Water

Factors Affecting Precipitation of Calcium Carbonate

Several other doctors also examined him from time to time.

Antioxidant Products. A comprehensive range of. Antioxidants

Laboratory Monitoring of Adult Hospital Patients Receiving Parenteral Nutrition

This package insert contains information to run the Cholesterol assay on the ARCHITECT c Systems and the AEROSET System.

How To Test For Creatinine

Visual Acuity. Hearing. Height and Weight. Blood Pressure MEASURED VALUE

Medicare coding and reimbursement for clinical laboratory services

Name Class Date. Section: Calculating Quantities in Reactions. Complete each statement below by writing the correct term or phrase.

Quality Control Products & Services Catalog

Presents: Insider tips for the life insurance medical exam. Know what they are testing for--and how to get the best results.

MUSC Occupational Blood Borne Pathogen Protocol Off-Campus Procedure Packet

Effects of heparin, citrate, and EDTA on plasma biochemistry of cat: comparison with serum

How To Safely Use An Ivm System

510(K) SUMMARY FEB Submitter: Name of the device: * Common Name: Clinical Chemistry Analyzer (with optional ISE Module) Attachment #2

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

The child with abnormal liver function tests

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #:

PHYSICIANS LABORATORY SERVICES ANNUAL NOTICE TO PROVIDERS 2012

Calculation of Molar Masses. Molar Mass. Solutions. Solutions


The Skinny on Trans Fats. Piper Mattson, M.S., R.D. Nutrition Education Specialist Montebello U.S.D.

LABORATORY MEDICINE CATEGORY LIST. CATEGORY I Laboratories, Vested Interest Laboratory and Hospitals

Gastrointestinal Pathophysiology Exam 2006 Tufts University School of Medicine

HOW TO EVALUATE ELEVATED LIVER ENZYMES

Non-alcoholic fatty liver disease: Prognosis and Treatment

Introduction to the Rhode Island Workers Compensation Fee Schedule

Daily Diabetes Management Book

Medicare Benefit Policy Manual Chapter 11 - End Stage Renal Disease (ESRD)

3240 Whipple Rd. Bunsenstr. 9-11

Transcription:

Test: ACID PHOS. (NP) Catalog # : A7503 TEST NAME: ACID PHOS. (NP) TEST CODE: [AP (NP)] UNITS: [U/L] PRECISION (DECIMAL): [0] Kinetic MATH MODEL: Fixed Factor FACTOR: 1318.00 [<] [ 2.00 ] [ 0.0 ] <x> [ 35.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [25 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 ACID PHOS (NP) [ 400 UL ] Reagent Wheel Mixing Well 2 (405) FILTER #1 STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 0 ] None Selected LAG TIME (SECONDS [ 220 SEC ] SAMPLE INTERVAL (SECONDS) [ 10 SEC ] NUMBER OF DATA POINTS [ 10 ] PRINT SEQUENCE # [ ] TEST NAME: ACID PHOS. (NP) DEF Defau [ ] [ ] PAN Panic [] [ ] It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: ALBUMIN Catalog # : A7502 TEST NAME: ALBUMIN TEST CODE: [ALB] UNITS: [G/DL] PRECISION (DECIMAL): [1] Endpoint MATH MODEL: Linear FACTOR: 0.00 [<] [ 2.00 ] [ 0.0 ] <x> [ 6.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [5 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 ALBUMIN [ 500 UL ] Reagent Wheel Mixing Well 5 (620) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 60 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ 0 SEC ] SAMPLE INTERVAL (SECONDS) [ 0 SEC ] NUMBER OF DATA POINTS [ 0 ] PRINT SEQUENCE # [30 ] TEST NAME: ALBUMIN DEF Defau [ 3.5 ] [ 5.3] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: ALK PHOS (LIQUID) Catalog # : A7516 TEST NAME: ALK PHOS (LIQUID) TEST CODE: [ALK] UNITS: [U/L] PRECISION (DECIMAL): [0] Kinetic MATH MODEL: Fixed Factor FACTOR: 2720.00 [<] [ 2.00 ] [ 0.0 ] <x> [ 800.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [10 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 ALK PHOS [ 500 UL ] Reagent Wheel Mixing Well 2 (405) FILTER #1 STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 0 ] None Selected LAG TIME (SECONDS [ 50 SEC ] SAMPLE INTERVAL (SECONDS) [ 20 SEC ] NUMBER OF DATA POINTS [ 10 ] PRINT SEQUENCE # [40 ] TEST NAME: ALK PHOS (LIQUID) DEF Defau [ 35.0 ] [ 123.0] PAN Panic [] [ ] It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: ALK PHOS Catalog # : A7505 TEST NAME: ALK PHOS TEST CODE: [ALK] UNITS: [U/L] PRECISION (DECIMAL): [0] Kinetic MATH MODEL: Fixed Factor FACTOR: 2720.00 [<] [ 2.00 ] [ 0.0 ] <x> [ 800.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [10 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 ALK PHOS [ 500 UL ] Reagent Wheel Mixing Well 2 (405) FILTER #1 STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 0 ] None Selected LAG TIME (SECONDS [ 51 SEC ] SAMPLE INTERVAL (SECONDS) [ 35 SEC ] NUMBER OF DATA POINTS [ 6 ] PRINT SEQUENCE # [40 ] TEST NAME: ALK PHOS DEF Defau [ 35.0 ] [ 123.0] PAN Panic [] [ ] It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: ALT (SGPT) LIQUID Catalog # : A7526 TEST NAME: ALT (SGPT) LIQUID TEST CODE: [ALT] UNITS: [U/L] PRECISION (DECIMAL): [0] Kinetic MATH MODEL: Fixed Factor FACTOR: -3376.00 [>] [ 0.60 ] [ 0.0 ] <x> [ 500.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [20 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 ALT [ 400 UL ] Reagent Wheel Mixing Well 1 (340) FILTER #1 STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ ] None Selected LAG TIME (SECONDS [ 60 SEC ] SAMPLE INTERVAL (SECONDS) [ 25 SEC ] NUMBER OF DATA POINTS [ 10 ] PRINT SEQUENCE # [50 ] TEST NAME: ALT (SGPT) LIQUID DEF Defau [ 4.0 ] [ 36.0] PAN Panic [] [ ] It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: ALT (SGPT) Catalog # : A7525 TEST NAME: ALT (SGPT) TEST CODE: [ALT] UNITS: [U/L] PRECISION (DECIMAL): [0] Kinetic MATH MODEL: Fixed Factor FACTOR: -3376.00 [>] [ 0.60 ] [ 0.0 ] <x> [ 500.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [20 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 ALT [ 400 UL ] Reagent Wheel Mixing Well 1 (340) FILTER #1 STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ ] None Selected LAG TIME (SECONDS [ 79 SEC ] SAMPLE INTERVAL (SECONDS) [ 35 SEC ] NUMBER OF DATA POINTS [ 6 ] PRINT SEQUENCE # [ ] TEST NAME: ALT (SGPT) DEF Defau [ 0.0 ] [ 38.0] PAN Panic [] [ ] It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: AMYLASE Catalog # : A7564 TEST NAME: AMYLASE TEST CODE: [AMY] UNITS: [U/L] PRECISION (DECIMAL): [0] Kinetic MATH MODEL: Fixed Factor FACTOR: 3178.30 [<] [ 2.50 ] [ 0.0 ] <x> [ 2000.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [10 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 AMYLASE [ 400 UL ] Reagent Wheel Mixing Well 2 (405) FILTER #1 STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ ] None Selected LAG TIME (SECONDS [ 15 SEC ] SAMPLE INTERVAL (SECONDS) [ 10 SEC ] NUMBER OF DATA POINTS [ 9 ] PRINT SEQUENCE # [ ] TEST NAME: AMYLASE DEF Defau [ 25.0 ] [ 125.0] PAN Panic [] [ ] It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: AST (SGOT) LIQUID Catalog # : A7561 TEST NAME: AST (SGOT) LIQUID TEST CODE: [AST] UNITS: [U/L] PRECISION (DECIMAL): [0] Kinetic MATH MODEL: Fixed Factor FACTOR: -3376.00 [>] [ 0.60 ] [ 0.0 ] <x> [ 500.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [20 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 AST [ 400 UL ] Reagent Wheel Mixing Well 1 (340) FILTER #1 STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 0 ] None Selected LAG TIME (SECONDS [ 60 SEC ] SAMPLE INTERVAL (SECONDS) [ 25 SEC ] NUMBER OF DATA POINTS [ 10 ] PRINT SEQUENCE # [70 ] TEST NAME: AST (SGOT) LIQUID DEF Defau [ 5.0 ] [ 34.0] PAN Panic [] [ ] It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: AST (SGOT) Catalog # : A7560 TEST NAME: AST (SGOT) TEST CODE: [AST] UNITS: [U/L] PRECISION (DECIMAL): [0] Kinetic MATH MODEL: Fixed Factor FACTOR: -3376.00 [>] [ 0.60 ] [ 0.0 ] <x> [ 500.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [20 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 AST [ 400 UL ] Reagent Wheel Mixing Well 1 (340) FILTER #1 STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ ] None Selected LAG TIME (SECONDS [ 149 SEC ] SAMPLE INTERVAL (SECONDS) [ 35 SEC ] NUMBER OF DATA POINTS [ 8 ] PRINT SEQUENCE # [ ] TEST NAME: AST (SGOT) DEF Defau [ 0.0 ] [ 40.0] PAN Panic [] [ ] It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: BILIRUBIN, DIRECT Catalog # : B7538 TEST NAME: BILIRUBIN DIRECT TEST CODE: [D. BILI] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Endpoint MATH MODEL: Linear FACTOR: 0.0 [<] [ 1.50 ] [ 0.0 ] <x> [ 18.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [40 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 D. BILI [ 400 UL ] Reagent Wheel Mixing Well #2 [ 15UL] Sample Wheel Sample Shelf 4 (550) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 300 SEC ] Biblirubin Calibrator LAG TIME (SECONDS [ ] SAMPLE INTERVAL (SECONDS) [ ] NUMBER OF DATA POINTS [ ] PRINT SEQUENCE # [ ] TEST NAME: BILIRUBIN DIRECT DEF Defau [ 0.0 ] [ 0.5] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: BILIRUBIN, TOTAL Catalog # : B7576 TEST NAME: BILIRUBIN TOTAL TEST CODE: [T. BILI] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Endpoint MATH MODEL: Linear FACTOR: 0.0 [<] [ 1.50 ] [ 0.0 ] <x> [ 20.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING [15 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 T. BILI [ 500 UL ] Reagent Wheel Mixing Well 4 (550) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 60 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ ] SAMPLE INTERVAL (SECONDS) [ ] NUMBER OF DATA POINTS [ ] PRINT SEQUENCE # [ ] TEST NAME: BILIRUBIN TOTAL DEF Defau [ 0.2 ] [ 1.2] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: BUN LIQUID Catalog # : B7552 TEST NAME: BUN LIQUID TEST CODE: [BUN] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Kinetic MATH MODEL: Linear FACTOR: 0.0 [>] [ 0.45 ] [ 0.0 ] <x> [ 150.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [5 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 BUN [ 500 UL ] Reagent Wheel Mixing Well 1 (340) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 0 ] Chemistry Calibrator LAG TIME (SECONDS [ 15 SEC ] SAMPLE INTERVAL (SECONDS) [ 50 SEC ] NUMBER OF DATA POINTS [ 2 ] PRINT SEQUENCE # [100 ] TEST NAME: BUN LIQUID DEF Defau [ 7.0 ] [ 18.0] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: BUN Catalog # : B7550 TEST NAME: BUN TEST CODE: [BUN] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Kinetic MATH MODEL: Linear FACTOR: 0.0 [>] [ 0.45 ] [ 0.0 ] <x> [ 85.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [5 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 BUN [ 500 UL ] Reagent Wheel Mixing Well 1 (340) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ ] Chemistry Calibrator LAG TIME (SECONDS [ 9 SEC ] SAMPLE INTERVAL (SECONDS) [ 10 SEC ] NUMBER OF DATA POINTS [ 6 ] PRINT SEQUENCE # [ ] TEST NAME: BUN DEF Defau [ 7.0 ] [ 18.0] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: CALCIUM Catalog # : C7503,C7508 TEST NAME: CALCIUM TEST CODE: [CA] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Endpoint MATH MODEL: Linear FACTOR: 0.0 [<] [ 2.00 ] [ 0.0 ] <x> [ 20.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING [15 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 CALCIUM [ 500 UL ] Reagent Wheel Mixing Well 4 (550) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 300 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ ] SAMPLE INTERVAL (SECONDS) [ ] NUMBER OF DATA POINTS [ ] PRINT SEQUENCE # [ ] TEST NAME: CALCIUM DEF Defau [ 8.5 ] [ 10.5] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: CALCIUM (ARSENAZO) Catalog # : C7529 TEST NAME: CALCIUM (ARSENAZO) TEST CODE: [CA] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Endpoint MATH MODEL: Linear FACTOR: 0.0 [<] [ 2.00 ] [ 0.0 ] <x> [ 15.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [5 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 CALCIUM ARSENAZO [ 500 UL ] Reagent Wheel Mixing Well 5 (620) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 300 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ 0 ] SAMPLE INTERVAL (SECONDS) [ 0 ] NUMBER OF DATA POINTS [ 0 ] PRINT SEQUENCE # [110 ] TEST NAME: CALCIUM (ARSENAZO) DEF Defau [ 8.5 ] [ 10.4] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: CHLORIDE Catalog # : C7501 TEST NAME: CHLORIDE TEST CODE: [CHL] UNITS: [MEQ/L] PRECISION (DECIMAL): [0] Endpoint MATH MODEL: Linear FACTOR: 0.0 [<] [ 2.00 ] [ 0.0 ] <x> [ 130.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [5 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 CHLORIDE [ 500 UL ] Reagent Wheel Mixing Well 3 (500) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 300 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ 0 ] SAMPLE INTERVAL (SECONDS) [ 0 ] NUMBER OF DATA POINTS [ 0 ] PRINT SEQUENCE # [0 ] TEST NAME: CHLORIDE DEF Defau [ 98 ] [ 106] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: CHOLESTEROL (LIQUID) Catalog # : C7510 TEST NAME: CHOLESTEROL (LIQUID) TEST CODE: [CHOL] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Endpoint MATH MODEL: Linear FACTOR: 0.0 [<] [ 1.50 ] [ 0.0 ] <x> [ 500.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [5 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 CHOLESTEROL [ 500 UL ] Reagent Wheel Mixing Well 3 (500) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 300 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ 0 ] SAMPLE INTERVAL (SECONDS) [ 0 ] NUMBER OF DATA POINTS [ 0 ] PRINT SEQUENCE # [130 ] TEST NAME: CHOLESTEROL (LIQUID) DEF Defau [ - ] [ >200.0] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: CHOLESTEROL Catalog # : C7509 TEST NAME: CHOLESTEROL TEST CODE: [CHOL] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Endpoint MATH MODEL: Linear FACTOR: 0.0 [<] [ 1.50 ] [ 0.0 ] <x> [ 500.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING [5 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 CHOLESTEROL [ 500 UL ] Reagent Wheel Mixing Well 3 (500) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 300 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ ] SAMPLE INTERVAL (SECONDS) [ ] NUMBER OF DATA POINTS [ ] PRINT SEQUENCE # [ ] TEST NAME: CHOLESTEROL DEF Defau [ - ] [ >200.0] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: CARBON DIOXIDE (340NM) Catalog # : C7504 TEST NAME: CARBON DIOXIDE (340NM) TEST CODE: [CO2] UNITS: [MMOL/L] PRECISION (DECIMAL): [0] Initial Rate MATH MODEL: Linear FACTOR: 0.0 [<] [ 2.00 ] [ 0.0 ] <x> [ 40.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING [5 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 CO2 [ 500 UL ] Reagent Wheel Mixing Well 1 (340) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 0 ] Chemistry Calibrator LAG TIME (SECONDS [ 45 SEC ] SAMPLE INTERVAL (SECONDS) [ 30 SEC ] NUMBER OF DATA POINTS [ ] PRINT SEQUENCE # [ ] TEST NAME: CARBON DIOXIDE (340NM) DEF Defau [ 23.0 ] [ 34.0] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: CPK Catalog # : C7512 TEST NAME: CPK TEST CODE: [CPK] UNITS: [U/L] PRECISION (DECIMAL): [0] Kinetic MATH MODEL: Fixed Factor FACTOR: 5520.00 [<] [ 1.50 ] [ 0.0 ] <x> [ 1500.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [15 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 CPK [ 500 UL ] Reagent Wheel Mixing Well 1 (340) FILTER #1 STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ ] None Selected LAG TIME (SECONDS [ 79 ] SAMPLE INTERVAL (SECONDS) [ 35 SEC ] NUMBER OF DATA POINTS [ 6 ] PRINT SEQUENCE # [ ] TEST NAME: CPK DEF Defau [ 0.0 ] [ 160] PAN Panic [] [ ] It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: CK-MB Catalog # : C7562 TEST NAME: CK-MB TEST CODE: [CK-MB] UNITS: [U/L] PRECISION (DECIMAL): [0] Kinetic MATH MODEL: Fixed Factor FACTOR: 6263.00 [<] [ 1.50 ] [ 0.0 ] <x> [ 1500.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [23 UL] Mixing Well SLOW RGT. ARM ASCENT #1 CK-MB [ 400 UL ] Reagent Wheel Mixing Well #2 [ 0 UL] Sample Wheel Sample Shelf 1 (340) FILTER #1 STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ ] None Selected LAG TIME (SECONDS [ 149 SEC ] SAMPLE INTERVAL (SECONDS) [ 70 SEC ] NUMBER OF DATA POINTS [ 3 ] PRINT SEQUENCE # [ ] TEST NAME: CK-MB DEF Defau [ 0.0 ] [ 22.0] PAN Panic [] [ ] It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: CREATININE Catalog # : C7539 TEST NAME: CREATININE TEST CODE: [CREAT] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Initial Rate MATH MODEL: Linear FACTOR: 0.0 [<] [ 1.00 ] [ 0.0 ] <x> [ 25.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING [20 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 CREATININE [ 350 UL ] Reagent Wheel Mixing Well 3 (500) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ ] Chemistry Calibrator LAG TIME (SECONDS [ 23 SEC ] SAMPLE INTERVAL (SECONDS) [ 70 SEC ] NUMBER OF DATA POINTS [ ] PRINT SEQUENCE # [ ] TEST NAME: CREATININE DEF Defau [ 0.4 ] [ 1.40] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: CRP-HS Catalog # : C7564 TEST NAME: CRP-HS TEST CODE: [CRP] UNITS: [MG/DL] PRECISION (DECIMAL): [3] Endpoint MATH MODEL: 5 PARM LOG FACTOR: 0.0 [<] [ 2.00 ] [ 0.0 ] <x> [ 25.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [8 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 CRP [ 300 UL ] Reagent Wheel Mixing Well 4 (550) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 300 SEC ] CRP Calibrator LAG TIME (SECONDS [ 0 SEC ] SAMPLE INTERVAL (SECONDS) [ 0 ] NUMBER OF DATA POINTS [ 0 ] PRINT SEQUENCE # [200 ] TEST NAME: CRP-HS DEF Defau [ 0.10 ] [ 25.0] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: GGT (LIQUID) Catalog # : G7571 TEST NAME: GGT (LIQUID) TEST CODE: [GGT] UNITS: [U/L] PRECISION (DECIMAL): [0] Kinetic MATH MODEL: Fixed Factor FACTOR: 3614.00 [<] [ 1.50 ] [ 0.0 ] <x> [ 1000.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [15 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 GGT [ 500 UL ] Reagent Wheel Mixing Well 2 (405) FILTER #1 STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 0 ] None Selected LAG TIME (SECONDS [ 50 SEC ] SAMPLE INTERVAL (SECONDS) [ 25 SEC ] NUMBER OF DATA POINTS [ 8 ] PRINT SEQUENCE # [170 ] TEST NAME: GGT (LIQUID) DEF Defau [ 8.0 ] [ 54.0] PAN Panic [] [ ] It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: GGT Catalog # : G7570 TEST NAME: GGT TEST CODE: [GGT] UNITS: [U/L] PRECISION (DECIMAL): [0] Kinetic MATH MODEL: Fixed Factor FACTOR: 3614.00 [<] [ 1.50 ] [ 0.0 ] <x> [ 1000.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [15 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 GGT [ 500 UL ] Reagent Wheel Mixing Well 2 (405) FILTER #1 STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ ] None Selected LAG TIME (SECONDS [ 51 SEC ] SAMPLE INTERVAL (SECONDS) [ 35 SEC ] NUMBER OF DATA POINTS [ 6 ] PRINT SEQUENCE # [ ] TEST NAME: GGT DEF Defau [ 8.0 ] [ 54.0] PAN Panic [] [ ] It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: GLUCOSE (HEX) LIQUID Catalog # : G7517 TEST NAME: GLUCOSE (HEX) LIQUID TEST CODE: [GLUC] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Bichromatic MATH MODEL: Linear FACTOR: 0.0 [<] [ 2.50 ] [ 0.0 ] <x> [ 500.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [5 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 GLU-HEX [ 500 UL ] Reagent Wheel Mixing Well 1 (340) FILTER #1 2 (405) FILTER #2 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 300 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ 0 SEC ] SAMPLE INTERVAL (SECONDS) [ 0 ] NUMBER OF DATA POINTS [ 0 ] PRINT SEQUENCE # [180 ] TEST NAME: GLUCOSE (HEXOKINASE) LIQUID DEF Defau [ 65.0 ] [ 110.0] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: GLUCOSE (HEX) Catalog # : G7518 TEST NAME: GLUCOSE (HEX) TEST CODE: [GLUC] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Bichromatic MATH MODEL: Linear FACTOR: 0.0 [<] [ 2.50 ] [ 0.0 ] <x> [ 500.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING [5 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 GLU-HEX [ 500 UL ] Reagent Wheel Mixing Well 1 (340) FILTER #1 2 (405) FILTER #2 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 300 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ ] SAMPLE INTERVAL (SECONDS) [ ] NUMBER OF DATA POINTS [ ] PRINT SEQUENCE # [ ] TEST NAME: GLUCOSE (HEXOKINASE) DEF Defau [ 65.0 ] [ 110.0] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: GLUCOSE (OX) LIQUID Catalog # : G7521 TEST NAME: GLUCOSE (OX) LIQUID TEST CODE: [GLUC] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Endpoint MATH MODEL: Linear FACTOR: 0.0 [<] [ 2.50 ] [ 0.0 ] <x> [ 500.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [5 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 GLU-OX [ 500 UL ] Reagent Wheel Mixing Well 3 (500) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 600 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ 0 ] SAMPLE INTERVAL (SECONDS) [ 0 ] NUMBER OF DATA POINTS [ 0 ] PRINT SEQUENCE # [180 ] TEST NAME: GLUCOSE (OXIDASE) LIQUID DEF Defau [ 65.0 ] [ 110.0] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: GLUCOSE (OX) Catalog # : G7519 TEST NAME: GLUCOSE (OX) TEST CODE: [GLUC] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Endpoint MATH MODEL: Linear FACTOR: 0.0 [<] [ 2.50 ] [ 0.0 ] <x> [ 500.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING [5 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 GLU-OX [ 500 UL ] Reagent Wheel Mixing Well 3 (500) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 300 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ ] SAMPLE INTERVAL (SECONDS) [ ] NUMBER OF DATA POINTS [ ] PRINT SEQUENCE # [ ] TEST NAME: GLUCOSE (OXIDASE) DEF Defau [ 65.0 ] [ 110.0] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: HDL CHOLESTEROL Catalog # : H7507/H7511 TEST NAME: HDL CHOLESTEROL TEST CODE: [HDL] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Endpoint MATH MODEL: Linear FACTOR: 0.0 [<] [ 1.50 ] [ 0.0 ] <x> [ 350.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING [15 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 HDL-C [ 500 UL ] Reagent Wheel Mixing Well 3 (500) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 300 SEC ] Cholesterol Calibrator LAG TIME (SECONDS [ ] SAMPLE INTERVAL (SECONDS) [ ] NUMBER OF DATA POINTS [ ] PRINT SEQUENCE # [ ] TEST NAME: HDL CHOLESTEROL DEF Defau [ 27.0 ] [ 98.0] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: autohdl Catalog # : H7545 TEST NAME: autohdl TEST CODE: [HDL] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Initial Rate MATH MODEL: Linear FACTOR: 0.0 [<] [ 2.00 ] [ 0.0 ] <x> [ 150.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [3 UL] Mixing Well SLOW RGT. ARM ASCENT #1 autohdl [ 240 UL ] Reagent Wheel Mixing Well #2 [ 80 UL] Reagent Wheel Reagent Shelf 5 (620) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 0 ] AutoCal LAG TIME (SECONDS [ 5 SEC ] SAMPLE INTERVAL (SECONDS) [ 300 SEC ] NUMBER OF DATA POINTS [ 0 ] PRINT SEQUENCE # [200 ] TEST NAME: autohdl DEF Defau [ ] [ ] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: IRON Catalog # : I7504, I7505 TEST NAME: IRON TEST CODE: [IRON] UNITS: [UG/DL] PRECISION (DECIMAL): [0] Endpoint MATH MODEL: Linear FACTOR: 0.0 [<] [ 2.00 ] [ 0.0 ] <x> [ 500.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING [100 UL] Mixing Well SLOW RGT. ARM ASCENT #1 IRON [ 500 UL ] Reagent Wheel Mixing Well #2 [ 10 UL] Sample Wheel Sample Shelf 4 (550) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 600 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ ] SAMPLE INTERVAL (SECONDS) [ ] NUMBER OF DATA POINTS [ ] PRINT SEQUENCE # [ ] TEST NAME: IRON DEF Defau [ 60.0 ] [ 150.0] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: LDH-L (LIQUID) Catalog # : L7572 TEST NAME: LDH-L (LIQUID) TEST CODE: [LDH-L] UNITS: [U/L] PRECISION (DECIMAL): [0] Kinetic MATH MODEL: Fixed Factor FACTOR: 5520.0 [<] [ 1.50 ] [ 0.0 ] <x> [ 1000.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [15 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 LDH-L [ 500 UL ] Reagent Wheel Mixing Well 1 (340) FILTER #1 STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 0 ] None Selected LAG TIME (SECONDS [ 50 SEC ] SAMPLE INTERVAL (SECONDS) [ 20 SEC ] NUMBER OF DATA POINTS [ 10 ] PRINT SEQUENCE # [230 ] TEST NAME: LDH-L (LIQUID) DEF Defau [ 80.0 ] [ 285.0] PAN Panic [] [ ] It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: LDH-L Catalog # : L7535 TEST NAME: LDH-L TEST CODE: [LDH-L] UNITS: [U/L] PRECISION (DECIMAL): [0] Kinetic MATH MODEL: Fixed Factor FACTOR: 5520.00 [<] [ 1.50 ] [ 0.0 ] <x> [ 1300.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [15 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 LDH-L [ 500 UL ] Reagent Wheel Mixing Well 1 (340) FILTER #1 STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ ] None Selected LAG TIME (SECONDS [ 44 SEC ] SAMPLE INTERVAL (SECONDS) [ 35 SEC ] NUMBER OF DATA POINTS [ 6 ] PRINT SEQUENCE # [ ] TEST NAME: LDH-L DEF Defau [ 80.0 ] [ 285.0] PAN Panic [] [ ] It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: LIPASE (COLORIMETRIC) Catalog # : L7503 TEST NAME: LIPASE (COLORIMETRIC) TEST CODE: [LIP] UNITS: [U/L] PRECISION (DECIMAL): [0] Initial Rate MATH MODEL: Linear FACTOR: 0.0 [<] [ 2.00 ] [ 0.0 ] <x> [ 1000.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING [30 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 LIPASE [ 320 UL ] Reagent Wheel Mixing Well #2 [ 25 UL] Sample Wheel Sample Shelf 4 (550) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ ] Lipase Standard LAG TIME (SECONDS [ 170 SEC ] SAMPLE INTERVAL (SECONDS) [ 70 SEC ] NUMBER OF DATA POINTS [ ] PRINT SEQUENCE # [ ] TEST NAME: LIPASE (COLORIMETRIC) DEF Defau [ 0.0 ] [ 62.0] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: MAGNESIUM Catalog # : M7527 TEST NAME: MAGNESIUM TEST CODE: [MG] UNITS: [MEQ/L] PRECISION (DECIMAL): [0] Endpoint MATH MODEL: Linear FACTOR: 0.0 [<] [ 1.50 ] [ 0.0 ] <x> [ 6.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [5 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 MAGNESIUM [ 500 UL ] Reagent Wheel Mixing Well 4 (550) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 180 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ 0 SEC ] SAMPLE INTERVAL (SECONDS) [ 0 ] NUMBER OF DATA POINTS [ 0 ] PRINT SEQUENCE # [250 ] TEST NAME: MAGNESIUM DEF Defau [ 1.3 ] [ 2.5] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: PHOSPHORUS Catalog # : P7516 TEST NAME: PHOSPHORUS TEST CODE: [PHOS] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Endpoint MATH MODEL: Linear FACTOR: 0.0 [<] [ 2.00 ] [ 0.0 ] <x> [ 12.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING [15 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 PHOSPHORUS [ 500 UL ] Reagent Wheel Mixing Well 1 (340) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 240 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ ] SAMPLE INTERVAL (SECONDS) [ ] NUMBER OF DATA POINTS [ ] PRINT SEQUENCE # [ ] TEST NAME: PHOSPHORUS DEF Defau [ 2.5 ] [ 4.8] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: TOTAL PROTEIN Catalog # : T7528 TEST NAME: TOTAL PROTEIN TEST CODE: [TP] UNITS: [G/DL] PRECISION (DECIMAL): [0] Endpoint MATH MODEL: Linear FACTOR: 0.0 [<] [ 1.00 ] [ 0.0 ] <x> [ 15.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [10 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 PROTEIN [ 500 UL ] Reagent Wheel Mixing Well 4 (550) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 300 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ ] SAMPLE INTERVAL (SECONDS) [ ] NUMBER OF DATA POINTS [ ] PRINT SEQUENCE # [ ] TEST NAME: TOTAL PROTEIN DEF Defau [ 6.2 ] [ 8.5] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: TRIGLYCERIDE LIq (GPO) Catalog # : T7532 TEST NAME: TRIGLYCERIDE LIQUID (GPO) TEST CODE: [TRIG] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Endpoint MATH MODEL: Linear FACTOR: 0.0 [<] [ 2.00 ] [ 0.0 ] <x> [ 1000.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING [5 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 TRIGLYCERIDE [ 500 UL ] Reagent Wheel Mixing Well 3 (500) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 300 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ ] SAMPLE INTERVAL (SECONDS) [ ] NUMBER OF DATA POINTS [ ] PRINT SEQUENCE # [ ] TEST NAME: TRIGLYCERIDE LIQUID (GPO) DEF Defau [ 36.0 ] [ 165] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: URIC ACID LIQUID Catalog # : U7581 TEST NAME: URIC ACID LIQUID TEST CODE: [UA] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Endpoint MATH MODEL: Linear FACTOR: 0.0 [<] [ 1.50 ] [ 0.0 ] <x> [ 25.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING Not Active [15 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 URIC ACID [ 400 UL ] Reagent Wheel Mixing Well 4 (550) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 600 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ 0 ] SAMPLE INTERVAL (SECONDS) [ 0 ] NUMBER OF DATA POINTS [ 0 ] PRINT SEQUENCE # [290 ] TEST NAME: URIC ACID LIQUID DEF Defau [ 2.5 ] [ 7.7] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.

Test: URIC ACID Catalog # : U7580 TEST NAME: URIC ACID TEST CODE: [UA] UNITS: [MG/DL] PRECISION (DECIMAL): [0] Endpoint MATH MODEL: Linear FACTOR: 0.0 [<] [ 1.50 ] [ 0.0 ] <x> [ 25.0 ] SAMPLE BLANK SAMPLE VOL SAMPLE LOAD LOCATION REAGENT BLANK READING [15 UL] Sample Shelf SLOW RGT. ARM ASCENT #1 URIC ACID [ 500 UL ] Reagent Wheel Mixing Well 4 (550) FILTER #1 X STANDARD REQUIRED: [ ] # CONTROLS REQUIRED EQUILIBRATION TIME (MIN.): [ 300 SEC ] Chemistry Calibrator LAG TIME (SECONDS [ ] SAMPLE INTERVAL (SECONDS) [ ] NUMBER OF DATA POINTS [ ] PRINT SEQUENCE # [ ] TEST NAME: URIC ACID DEF Defau [ 2.5 ] [ 7.7] PAN Panic [] [ ]

It is recommended that two levels of control material be assayed daily. Reorder PSI Chemistry Controls Cat.# C7590-50 & C7591-50.