THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Similar documents
THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS


REDRING POWERSTREAM-ECO UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

Shower Handbook (Also covers 650 chrome variant)

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Getting the best from your urn

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Assembly and instructions

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Portable Air Conditioner

Meaco 30L and Meaco 40L dehumidifier instruction manual

Elson 2.5 litre Boiling Water Dispenser

Please read and keep these instructions. Run water through your machine before first use

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

SF15K SF05KSS, SF10KSS

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

SUB Universal water baths SBB Boiling baths JB, PB Unstirred water baths

ELECTRIC INSTANTANEOUS WATER HEATER

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

INFRARED QUARTZ WALL HEATER

CARING FOR YOUR WATER HEATER

Design Utility Lever Thermostatic Bath Shower Mixer

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

Elson 10/15L Unvented Water Heater

Triac Printed Circuit Board Replacement

Please also see 10 golden rules for correct Saniflo installation on

Cara electric shower Installation and operating instructions

Aquatap (Boil and Chill / Boil and Ambient) Installation and user manual

Due to continual improvement in design or otherwise, the product you purchase may differ slightly from the illustrations in this book.

Installation, Operating and Servicing Instructions. Electric Auto-Fill Push Button Water Boilers EB3F/PB and EB3F/PBM

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Chill 4 Hole Bath Shower Mixer

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

ClearView 100. Instruction Manual

Electric Water Heater

This section gives you some helpful information and tips on running your home and the equipment in it.

Ceiling Mount Air Handler Manual

3 IN 1 BATHROOM HEATER

Hot Water Central. Electric Hot Water Dispenser. Instruction Manual AAP-325W.

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Hot Water Urns. all models. Helpline. v3.0

100 Series Maxi Internal Filters. Instruction Manual

For installation guide see reverse of book

User's Instructions. Alpha HE CB25/33 and HE SY25

PG_IM_A.indd 1 23/06/ :22

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

High kw Electric Tankless Water Heater Troubleshooting Guide

Calor de Hogar. Av Tecnológico 735, PB. San Salvador Tizatlalli. Metepec, 52172, Edo de México. Teléfono (722) (55)

Tassimo The Art of the Perfect Cup

VOYAGER 570G. 744A Sprayer Control

Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold

Electric Mini Tank Water Heaters WM-2.5 & WM-4.0

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

B150 Series Commercial Brewer. Direct Plumb Kit

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH7/2.2, AH10/2.2, AH15/2.2

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

Oil and Coolant Circulating Heating System. Model - OCSM

Overheating limit control

1. Description. 2. List of Accessories included A B C F G H

Unvented water heater

SERVICE MANUAL Order No.WH0911S001V0

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

Installation and Operating Instruction Manual

Coolflo Safe Touch Shower Mixing Valve ST20015CP

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

OWNER S MANUAL & INSTALLATION GUIDE. Installation Details Owner s Information Warranty. 80L - 400L Electric Storage Water Heaters

OPERATING INSTRUCTIONS

STABITHERM INSTALLATION & SERVICE BOOKLET

Protect your pipes. Keep the water cycle running smoothly and be prepared in winter. Heat, insulate and protect your home.

Electronically Controlled Instantaneous Water Heaters Models: DEX & DBX

Mini Tank. Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0. Installation and Operating Instruction Manual

Isotemp Basic, Slim/B & Slim Square

WHEN TO CHANGE YOUR BRITA MAXTRA CARTRIDGE

SHC 2.5, SHC 4 MINI-TANK ELECTRIC WATER HEATERS INSTALLATION INSTRUCTIONS FOR THE LICENSED PLUMBER SHC 2.5 SHC 4. English. English

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

2-SLICE COOL TOUCH TOASTER

HOT WATER HEAT PUMP MANUAL FOR ADVICE, REPAIRS AND SERVICE: CALL (AUSTRALIA) (NZ)

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

Aquamax Australia Pty Ltd ABN

Response: The combi boiler. Response: The fit anywhere combi

Operators manual Basic water heater

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Frequently asked Questions about Drinking Water Supply.

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List

Transcription:

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: This booklet should be left with the user after installation and demonstration

Thank you for choosing a quality Redring product manufactured in Peterborough, England Contents Installation Instructions Important notes......................................................... 3 What the installer will need................................................ 4 Where to locate the SB².................................................. 4 Installing the water supply and steam vent pipes............................... 4 Installing the mains supply................................................ 5 Removing the front cover................................................. 5 Fixing the unit on the wall................................................. 7 Connecting the water supply and steam vent pipes............................. 7 Connecting the mains cable............................................... 7 Replacing the front cover................................................. 7 Schematic wiring diagram................................................ 7 Operating Instructions After Sales Service...................................................... 2 General product description............................................... 8 How to operate the SB².................................................. 8 How to clean and descale your SB²......................................... 9 Trouble shooting guidance................................................ 10 Guarantee............................................................ 12 Page THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LACK OF EXPERIENCE AND KNOWLEDGE IF THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND UNDERSTAND THE HAZARDS INVOLVED. CHILDREN SHALL NOT PLAY WITH THE APPLIANCE. CLEANING AND USER MAINTENANCE SHALL NOT BE MADE BY CHILDREN Redring After Sales Service We offer a technical advisory service on the telephone to contractors and other customers with problems in the field. Please call our technical team on: 0844 372 7766 Or alternatively email us on: Service.request@redringxpelair.com Many Spare parts can be also be supplied by contacting us as shown above Remember to quote the exact model of SB² unit, as written on the front of the unit and on this leaflet. It may also be of use to have a note of the model and serial number as stated on the underside of the unit. Make a note of those numbers here, and be sure to quote them if you call for advice. Model Number: / Serial Number: _ Note: You may be charged for a service call if you do not have the serial number. 2

Important Notes This appliance is intended to be used in household and similar applications such as:- - staff kitchen areas in shops, offices and other working environments; - farm houses; - by clients in hotels, motels and other residential type environments; - bed and breakfast type environments. All installations must be undertaken by a competent installer. If in any doubt, advice and assistance should be sought from a qualified plumber and/or electrician. Installation and wiring must conform to the current BS.7671 (IEE Wiring Regulations) and the Water Fitting Regulations. Local regulations may apply in other countries. The steam vent connection MUST BE MADE, (see page 4) A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with the wiring rules. Check that the mains supply matches the electrical rating on the product. The rating plate is located on the bottom edge of the unit. Frost Protection: This appliance should be located where the ambient air temperature is between 5 C and 50 C. If the temperature may fall below 5 C when the appliance is not in use, do not turn off the appliance electrically. This safeguard does NOT offer protection to the connecting pipe work and fittings. The unit should not be operated if freezing is suspected. Allow the unit to thaw completely. This unit must not be cleaned by, or installed in an area cleaned by a water jet. THIS APPLIANCE, AND ALL METAL PIPEWORK CONNECTED TO IT, MUST BE EARTHED. If you have any queries about installing this product or after it has been installed, please contact our Customer Service Helpline on 0844 372 7766 or alternatively email us on Service.request@redringxpelair.com Customers outside the U.K. should contact their local distributor. This product may need to be descaled regularly. The frequency of descaling will depend on the water supply hardness. 3

What the installer will need A means for disconnecting the fixed wiring in all poles in accordance with the wiring rules (ie. 13A fused double pole isolating switch). Suitable length of 1.0mm² 3-Core multi-strand PVC insulated mains cable that complies with BS.6500. Suitable lengths of Ø15mm copper pipe. Where to locate the SB² We recommend that the unit is installed on a suitable wall, at shoulder height and over a sink, with accessible area to maintain unit if and when required. Adjacent to the means for disconnecting the fixed wiring in all poles in accordance with the wiring rules (ie: 13A fused double pole isolating switch). Available mains cold water supply and drainage facility. DO NOT install the SB² within reach of a person using a bath or shower. This unit must not be installed in an area cleaned by a water jet. DO NOT obstruct the ventilation channel in the backplate. Installing the water supply and steam vent pipes The unit must be connected to cold, mains fed, drinking water only. Pressure range between 0.069 MPa (0.7 bar / 10 psi) and 1.0 MPa (10.0 bar / 140 psi). DO NOT connect to a storage tank Isolate the water supply Lay in the Ø15mm water supply pipe to the location of the inlet connection (Fig.1). Check that the water supply position gives enough space under the unit for it to be used properly. Flush through the water supply before making the final connection so that any debris is removed. Note: The inlet elbow contains a flow regulator: THIS MUST BE USED IN INSTALLATION Lay in the Ø15mm drainage pipe to the location of the steam vent connection (Fig.1). Connection is made using the push-fit adaptor provided. The steam vent connection must be taken directly to the sink below, if there is one, or via a tundish to a suitable drain. If a sink is used it must be able to withstand boiling water and have an overflow connection. Note: The steam vent outlet also acts as an overflow. 4

Installing the mains supply If a mains supply is not already available. Install a means for disconnecting the fixed wiring in all poles (ie. 13A fused double pole isolating switch) adjacent to where the unit will be fixed. Removing the front cover Remove the screw from the bottom and top edge of the unit (Fig.3). Support the front cover and remove the flow knob (Fig.4). Pull the front cover away form the unit and carefully remove the flying-lead and plug from the back-plate connector (Fig 5a and Fig.5b). 5

6

Fixing the unit to the wall Use the wall mounting bracket supplied and the two lower fixing holes. Ensure that the wall mounting bracket is mounted horizontally. An extra top fixing point is available by temporarily removing the condenser assembly. Connecting the water supply and vent pipes When the unit is fixed to the wall, make the final water supply and steam vent connections and secure the pipework. Switch the water supply back on. Connecting the mains cable Ensure the mains supply is isolated. Connect the mains cable from the SB² to the means for disconnection (ie. 13A fused double pole isolating switch). Ensure the cable clamps are firmly secured and the cable ends are tightened into the terminal block. Note: The supply cable must be a minimum of 1.0mm² 3-Core multi-strand PVC insulated mains cable. The terminal block will not accept cable diameters above 1.5mm². Check that the mains supply matches the electrical rating on the product. The rating plate is located on the bottom edge of the unit. IMPORTANT: Connect the supply cable, complying with BS.6500, to this appliance in accordance with the following code: GREEN AND YELLOW (EARTH) connect to the terminal marked. BLUE (NEUTRAL) connect to terminal marked N. BROWN (LIVE) connect to terminal marked L. WARNING: THIS APPLIANCE, AND ALL METAL PIPEWORK CONNECTED TO IT, MUST BE EARTHED. Replacing the front cover Support the cover and re-attach the flying-lead to the unit. Replace the front cover and secure using the top and bottom screws. Carefully replace the knob, ensuring correct alignment of the D-Shaft. Reconnect the mains supply. Schematic Wiring Diagram 7

Operating Instructions General Product Description The SB² is a wall mounted, self-calibrating and self-filling boiling water heater. It can be used for making cups of tea or coffee and even soups and hot snacks. A special condenser traps steam and returns droplets to the tank, minimising waste and saving energy. The water temperature is set and automatically maintained by the SB² and the unit is powered down with the Power button. Water is dispensed by rotating the front cover knob clockwise. How to operate the SB² (see Fig.6) Make sure the electricity and water are turned on. Use the POWER button to switch on the SB² on and to power down. The SB² should be switched off at the mains if the water is not required e.g. at weekends, holidays etc. POWER light: FULL light: TEMPERATURE READY light: when the SB² is on the POWER light will come on. Full light comes on when the tank is full of water. The SB² fills up automatically and this can take up to 10 minutes if the tank is completely empty. TEMPERATURE READY light comes on when the water is hot enough to use. This can happen even when the tank is not completely full of water. 8

Please Note: The SB² can take several minutes to reach the required temperature, depending on usage and tank capacity. To avoid energy wastage, the SB² will automatically reduce the temperature by 10 C if the unit is not used for more than 60 minutes. The SB² will automatically go back to boiling when the water is used. When the SB² is switched on at the local isolator and the POWER button is pressed, it will start by self-calibrating. This can take up to 20 minutes to complete and includes automatically boiling the water for 30 seconds. When first installed, it is recommended that the initial tank of boiling water is fully drawn off and discarded. Allow the tank to re-fill and the TEMPERATURE READY light to come on, before using the SB² Dispensing water from the SB²: Place your cup under the red spout at the bottom of the unit. Turn the knob clockwise to fill your cup (Fig.7b). Turn the knob anti-clockwise to OFF (Fig.7a). WARNING SCALDING HOT WATER can be dispensed from the SB². Never wash your hands directly from the unit. Some plastic cups can distort if they are filled with boiling water, so causing a danger of scalding. Do not use if heater is suspected of being frozen. Allow to thaw completely before use. How to clean and descale your SB² Cleaning: Before cleaning or descaling, switch off the electricity at the isolating switch. It is recommended that the SB² surfaces are cleaned with a soft cloth. Do not use abrasive or solvent cleaning fluids. Descaling: A suitably qualified person should carry out the descaling. Ensure the mains electricity supply is isolated. If scale comes out with the hot water then the SB² may need to be descaled. This is done by removing the front cover and top condenser assembly and using a suitable kettle descaler (a packet has been supplied). Ensure unit is thoroughly flushed through after descaling. 9

Trouble Shooting SELF HELP: If the SB² is not working satisfactorily, make the following checks before calling out the contractor. Any one of these adjustments could restore the performance. a) TEMPERATURE READY light is not on b) TEMPERATURE READY light is on but the FULL light is off c) The FULL light is on but the TEMPERATURE READY light is off d) The POWER light is on but the TEMPERATURE READY and FULL lights are both off e) TEMPERATURE READY light is on but the water is not boiling f) All the lights are out and the POWER button does not work g) The water flowing from the outlet is sometimes only a trickle h) The SB² takes a long time to reach the selected temperature i) Steam and very hot water sometimes dribble out of the vent at the back of the SB² j) The water tastes different k) Solid particles are visible in the water This is normal: The water has not yet reached the set temperature. (See Table 3 on page 11 for approximate heat up times). This is normal: Some water has been taken out of the tank so it is no longer full, but the water temperature is still hot enough to use. (The tank will automatically fill up again). This is normal: The tank will have automatically filled and the heater is still getting the water up to the boil. (See Table 3 on page 11 for approximate heat up times). This is normal: The tank is still filling up with water and the heater is still getting up to the boil. (See Table 3 on page 11 for approximate heat up times). To avoid energy wastage, the SB² is designed to automatically reduce the temperature by 10 C if the unit is not used for more than 60 minutes. (The SB² will automatically go back to boiling when the water is used). Ensure that the electricity supply is switched on at the local isolator, and then press the POWER button. The water in the tank has been drained out due to a high demand. Wait for the FULL and TEMPERATURE READY lights to come on again. When the SB² is first switched on it can take up to 18 minutes to reach the Boil setting. (See Table 3 on page 11 for approximate heat up times). Check that a pipe has been fitted to the steam vent. Contact your installer if missing. Use the POWER button to power down the unit and not the mains electrical local isolator. (This will reduce the amount of steam produced). The new SB² needs to be flushed out before being used first used. We recommend that the initial tank of boiling water is fully drawn off and discarded. Wait for the FULL and TEMPERATURE READY lights to come on, before using the unit. Scale has built up inside the tank. As with all water heaters scale may build up inside the water tank. How quickly this build up occurs will depend on the hardness of the water and the usage of the SB². Descale the SB² heater tank (This should be carried out by a suitably qualified person). We recommend the use of inline resin filters to protect the heater. 10

PROFESSIONAL SERVICE: If the SELF HELP checks do not cover the symptom, you should seek professional help. The following additional checklist is provided for the benefit of the qualified service person. WARNING: SWITCH OFF THE ELECTRICITY AT THE ISOLATING SWITCH BEFORE REMOVING THE COVER TO MAKE CHECKS a) Unit fails to heat the water b) All the light are out and the POWER button does not work c) Water flows continually from the steam vent pipe d) The water tank takes more than 20 minutes to fill with water Check that the water supply is on and that its pressure is between 0.069 MPa (0.7 bar / 10 psi) and 1.0 MPa (10.0 bar / 140 psi). Check circuit through solenoid coil. Check circuit through the heating element. Check circuit through float switch If defective then replace. Ensure that the electricity supply is switched on at the local isolator. Ensure that the flying lead to the front cover is connected properly (see Fig.5a and 5b). Check the supply to the PCB. If supply OK then change PCB. Check that the float switch operates correctly and switches the water solenoid on and off. Check that the water supply is on and that its pressure is between 0.069 MPa (0.7 bar / 10 psi) and 1.0 MPa (10.0 bar / 140 psi). Check operation of the water solenoid and that water flows into the tank at a rate between 0.3 litres/minute and 1.0 litres/minute. Check circuit through the solenoid coil If defective then replace. SB² Heat up times (table 3): CONDITION APPROXIMATE HEAT UP TIME APPROXIMATE HEAT UP TIME WHAT ELSE HAPPENS 2.5 Litre SB² 4 Litre SB² SB² is switched on at the local isolator and the unit is empty of water. POWER button is pressed. 12 minutes (4 minutes filling 8 minutes heating) 18 minutes (5 minutes filling 13 minutes heating) - POWER light comes on - then FULL light comes on - then TEMPERATURE READY light comes on - then steam comes out of vent for 30 seconds SB² is switched on at the local isolator and the unit is already full of cold water. POWER button is pressed. 8 minutes 13 minutes - POWER and FULL lights both come on - then TEMPERATURE READY light comes on - then steam comes out of vent for 30 seconds 11

GUARANTEE Terms and Conditions for UK (outside UK contact your local distributor) We guarantee this product for a period of 24 months from the date of purchase. Within the guarantee period we will resolve, free of charge, any manufacturing defects in the product resulting from faulty workmanship or material on condition that:- a) The product has been correctly installed and commissioned in accordance with our instructions and is being used on the supply circuit or voltage printed on the rating plate. b) The product has been used in accordance with these instructions and has not been tampered with or otherwise subject to misuse, neglect or accident. c) The product has not been taken apart, modified or repaired except by a person authorised by us. d) Evidence of the date of purchase in the form of an invoice or receipt will be required in order to qualify under the terms of this guarantee. e) SCALE PREVENTION: Formation of scale occurs with hot water heaters operating at high temperatures in hard water areas. We strongly recommend the use of in-line resin filters to protect the heater. The manufacturer guarantee DOES NOT cover these natural phenomena. f) For the service work to be undertaken free of charge, the work must only be undertaken by Redring Xpelair Group Limited, or our approved agents. g) Service under guarantee has no effect on the expiry date. The guarantee on any exchanged parts or product ends when the original guarantee period ends. EXCLUSIONS This guarantee DOES NOT cover damage or defects arising from poor or incorrect installation, improper use or lack of maintenance, including the build-up of limescale. It is the responsibility of the installer to check that the installation parameters meet the requirements of the products, and any relevant regulations. If we are called out to a fault, which is subsequently identified as being an installation fault, we will make a charge, it is important that the routine checks are completed before calling us out, as many issues can be simply diagnosed and resolved. A charge will be made where a call under the terms of the guarantee has been booked and a failure was not product related, or an engineer arrives and is not able to gain access. We make no guarantees as to response time for repairs. We will endeavour to achieve the most timely response possible but while we indicate an average response time, this should not be taken as a guarantee. The guarantee applies to a repair or replacement (at our discretion) of the product subject to the conditions above, and DOES NOT cover compensation for the loss of the product or consequential loss of any kind. This guarantee does not apply to the repair or replacement of pressure relief devices, descaling of the unit or damage caused by scale formation, or faults with isolating switches, electrical cable, fuses and/or circuit breakers. This guarantee does not affect your statutory rights. Full details of terms and conditions are available on request from:- REDRING XPELAIR GROUP LIMITED NEWCOMBE HOUSE, NEWCOMBE WAY, ORTON SOUTHGATE, PETERBOROUGH PE2 6SE TEL: +44 (0) 1733 456789 / FAX: +44 (0) 1733 319610 Website: www.redring.co.uk 12 (A4 Leaflet No: 571-2278-01g)