HowTo Check. Microsoft Cluster. Functionality via SNMP



Similar documents
How to simulate network devices using the Verax SNMP Simulator (Linux/Windows)

Simple Network Management Protocol

Set up and run your own Cesidian Root DNS server

TREK HOSC PAYLOAD ETHERNET GATEWAY (HPEG) USER GUIDE

TECHNICAL NOTE. Technical Note P/N REV 03. EMC NetWorker Simplifying firewall port requirements with NSR tunnel Release 8.

Oracle Enterprise Manager. Description. Platforms Supported. Versions Supported

How To - Implement Clientless Single Sign On Authentication with Active Directory

PANDORA FMS NETWORK DEVICES MONITORING

Immotec Systems, Inc. SQL Server 2005 Installation Document

New installation central network version

PANDORA FMS NETWORK DEVICE MONITORING

Oracle Enterprise Manager. Description. Versions Supported. Prerequisites

Simple Network Management Protocol

Windows Firewall Configuration with Group Policy for SyAM System Client Installation

KM Embedded. Configuration Guide. AIT Ltd 2 Hawthorn Park Coal Road Leeds LS14 1PQ UK

TPAf KTl Pen source. System Monitoring. Zenoss Core 3.x Network and

Maintaining Non-Stop Services with Multi Layer Monitoring

1 Scope of Assessment

Network Monitoring. By: Delbert Thompson Network & Network Security Supervisor Basin Electric Power Cooperative

This Technical Support Note shows the different options available in the Firewall menu of the ADTRAN OS Web GUI.

Configuring SSL VPN on the Cisco ISA500 Security Appliance

EventSentry Overview. Part I About This Guide 1. Part II Overview 2. Part III Installation & Deployment 4. Part IV Monitoring Architecture 13

Tue Apr 19 11:03:19 PDT 2005 by Andrew Gristina thanks to Luca Deri and the ntop team

SNMP Peach Pit Data Sheet

How To Configure L2TP VPN Connection for MAC OS X client

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

Mobile Admin Architecture

Knowledge Base Article: Article 218 Revision 2 How to connect BAI to a Remote SQL Server Database?

Rapid Assessment Key v2 Technical Overview

Integration Guide. LogicNow MAXfocus

Collax Monitoring with Nagios

Firewall Setup. Contents. Getting Started 2. Running A Firewall On A Mac Server 2. Configuring The OS X Firewall 3. Remote Rumpus Administration 4

Understanding HP Systems Insight Manager security

FreeFlow Core, Version 4.0 August P Xerox FreeFlow Core Security Guide

CS615 - Aspects of System Administration

Application Monitoring using SNMPc 7.0

Deploying Windows Streaming Media Servers NLB Cluster and metasan

How To Configure Apple ipad for Cyberoam L2TP

Configuring and Monitoring SNMP Generic Servers. eg Enterprise v5.6

Configuring and Monitoring Citrix Access Gateway-Linux Servers. eg Enterprise v5.6

BusinessObjects Enterprise XI Release 2

Application Discovery Manager User s Guide vcenter Application Discovery Manager 6.2.1

Procedure: You can find the problem sheet on Drive D: of the lab PCs. 1. IP address for this host computer 2. Subnet mask 3. Default gateway address

Deploying the BIG-IP LTM system and Microsoft Windows Server 2003 Terminal Services

VMware vcenter Log Insight Security Guide

Firewall Troubleshooting

Configuring and Launching ANSYS FLUENT Distributed using IBM Platform MPI or Intel MPI

Wanos on Hyper-V Comprehensive guide for a complete lab

BMC CONTROL-M Agentless Tips & Tricks TECHNICAL WHITE PAPER

Managing Ports and System Services using BT NetProtect Plus firewall

Cisco TelePresence Video Communication Server (Cisco VCS) IP Port Usage for Firewall Traversal. Cisco VCS X8.5 December 2014

1.6 HOW-TO GUIDELINES

O p e n N M S. Marcin Rybacki OpenNMS

Configuring Security Features of Session Recording

IBM Security QRadar Version Common Ports Guide

Configuring SNMP and using the NetFlow MIB to Monitor NetFlow Data

Integrating HP Insight Management WBEM (WMI) Providers for Windows with HP System Insight Manager

WÜRTHPHOENIX NetEye Version 3

F O U N D A T I O N. Using OPC via DCOM with Microsoft Windows XP Service Pack 2. Karl-Heinz Deiretsbacher, Siemens AG

Eaton NetWatch v5.0 NetWatch on Microsoft Hyper-V server 2008 Installation and configuration guide

How to put the DVR online

Using RADIUS Agent for Transparent User Identification

Zenoss Core 3.x Network and System Monitoring

ANNEXURE-1 TO THE TENDER ENQUIRY NO.: DPS/AMPU/MIC/1896. Network Security Software Nessus- Technical Details

CRMS SNMP Software Overview

Management, Logging and Troubleshooting

WhatsUpGold. v3.0. WhatsConnected User Guide

How-to configure Auditing for IDENTIKEY Authentication Server 3.2 to a remote Oracle Database on a standalone Microsoft machine.

This section describes how to set up, find and delete community strings.

Print Audit Facilities Manager Technical Overview

Deployment and Monitoring. Pascal Robert MacTI

Table of Contents Introduction and System Requirements 9 Installing VMware Server 35

Lecture 2-ter. 2. A communication example Managing a HTTP v1.0 connection. G.Bianchi, G.Neglia, V.Mancuso

Jason Hill HPC Operations Group ORNL Cray User s Group 2011, Fairbanks, AK

EMC Data Protection Search

Installing T-HUB on multiple computers

Before deploying SiteAudit it is recommended to review the information below. This will ensure efficient installation and operation of SiteAudit.

This configuration guide describes the installation process of SNMP on Windows and Linux with the NetBorder Express Gateway.

PIM SOFTWARE TR50. Configuring the Syslog Feature TECHNICAL REFERENCE page 1

Section 5 Configuring the Partition for Enterprise Output Manager (EOM)

Terminal Services vs. Remote Desktop Connection in Windows 2000 and Windows White Paper

Creating Cacti FortiGate SNMP Graphs

XIA Configuration Server

VPN: Installing the IPSec client

shortcut Tap into learning NOW! Visit for a complete list of Short Cuts. Your Short Cut to Knowledge

NovaBACKUP xsp Version 15.0 Upgrade Guide

M7 Modem SNMP Guide. M7 Modem Technical Note

Install MS SQL Server 2012 Express Edition

By Jascha Wanger

Installing GFI LANguard Network Security Scanner

HP JETADVANTAGE SECURITY MANAGER

windream with Firewall

Better Integration of Systems Management Hardware with Linux

Mobile Admin Security

TECHNICAL CONDITIONS REGARDING ACCESS TO VP.ONLINE. User guide. vp.online

Global Knowledge MEA Remote Labs. Remote Lab Access Procedure

Transcription:

HowTo Check Microsoft Cluster Functionality via SNMP Version 1.2 20.02.2009 Herbert Stadler hestadler@gmx.at

Table of Contents 1. SHORT INTRODUCTION...3 2. CHECK WINDOWS SNMP SERVICE...3 3. WINDOWS SNMP SERVICE CHECK ON WINDOWS SERVER...6 4. WINDOWS SNMP SERVICE CHECK ON REMOTE SERVER...7 5. CHECK HP MANAGEMENTS SERVICES INSTALLATION...8 6. CHECK HP MANAGEMENT AGENTS PROPERTIES...9 7. CHECK HP SYSTEMS MANAGEMENT HOMEPAGE...10 8. CHECK HP MANAGEMENTS SERVICES - ANSWERING...12 9. CHECK NAGIOS CLUSTER PLUGIN...13 10. HOW TO IMPLEMENT THE PLUGIN IN NAGIOS...15 11. SOME USEFUL SNMP ARTICLES...16 HowTo_Check_Windows_Cluster_via_SNMP_V1.2.doc 20.02.2009 Page 2 / 16

1. Short Introduction This document describes some useful hints for installation of the Nagios Plugin Checking Microsoft Cluster Server via SNMP protocol. If you have some trouble to get the plugin running start with the next paragraph and dig through the document. 2. Check Windows SNMP Service Check if the Windows SNMP Service daemon is installed and running. HOWTO: Configure the Simple Network Management Protocol (SNMP) Service in Windows Server 2003 http://support.microsoft.com/kb/324263/en-us HowTo_Check_Windows_Cluster_via_SNMP_V1.2.doc 20.02.2009 Page 3 / 16

Check if the UDP Port 161 (snmp) is open netstat -an -p UDP Possible Problems: SNMP service is not running/working HowTo_Check_Windows_Cluster_via_SNMP_V1.2.doc 20.02.2009 Page 4 / 16

Check the properties of the SNMP service HowTo_Check_Windows_Cluster_via_SNMP_V1.2.doc 20.02.2009 Page 5 / 16

3. Windows SNMP Service Check on Windows Server Is the SNMP Service answering? Check on Windows Server with SNMP utilities like snmpview, freesnmp or any other tool for any output. http://www.snmpview.de/ http://www.sharewareconnection.com/freesnmp.htm Possible Problems: SNMP service is not running/working HowTo_Check_Windows_Cluster_via_SNMP_V1.2.doc 20.02.2009 Page 6 / 16

4. Windows SNMP Service Check on remote Server Check if the SNMP Service is answering over the network. Check on Linux Server: snmpwalk -Os -c public -v 1 <physical node ip-address> system Possible Problems: Firewall No connection to the server -> check with ping HowTo_Check_Windows_Cluster_via_SNMP_V1.2.doc 20.02.2009 Page 7 / 16

5. Check HP Managements Services Installation Check if the HP Agents are installed and running. Possible Problems: HP Agents not installed HP Agents not running HowTo_Check_Windows_Cluster_via_SNMP_V1.2.doc 20.02.2009 Page 8 / 16

6. Check HP Management Agents Properties Please check if the Clustering Information is inactive. Activate Clustering Information. HowTo_Check_Windows_Cluster_via_SNMP_V1.2.doc 20.02.2009 Page 9 / 16

7. Check HP Systems Management Homepage Check if you see some information on Cluster Information. HowTo_Check_Windows_Cluster_via_SNMP_V1.2.doc 20.02.2009 Page 10 / 16

Check Cluster Information Possible Problems: HP Agents not working as needed HowTo_Check_Windows_Cluster_via_SNMP_V1.2.doc 20.02.2009 Page 11 / 16

8. Check HP Managements Services - Answering Check on Linux Server: snmpwalk < physical node ip-address> -v2c -c public enterprises.232.15 Possible Problems: HP Agents not installed HP Agents not running No connection to the server -> check with ping HowTo_Check_Windows_Cluster_via_SNMP_V1.2.doc 20.02.2009 Page 12 / 16

9. Check Nagios Cluster Plugin Check on Linux Server: From the nagios plugin directory call./check_mscs_hpma -H <host-ip> -v more If you get an answer like: ERROR: get_table_request: (1.3.6.1.4.1.232.15.2...) No response from remote host '<hostip>' Check again with additional parameter -Ct: snmpwalk <host-ip> -v2c -Ct -c public enterprises.232.15 and have a look at the last line Total traversal time if its higher than 2 seconds then use parameter -T for changing the SNMP timeout value to e.g. 10 or higher. example output: SNMPv2-SMI::enterprises.232.15.2.6.1.1.6.1 = INTEGER: 2 SNMPv2-SMI::enterprises.232.15.2.6.1.1.6.2 = INTEGER: 2 SNMPv2-SMI::enterprises.232.15.2.6.1.1.7.0 = INTEGER: 2 SNMPv2-SMI::enterprises.232.15.2.6.1.1.7.1 = INTEGER: 2 SNMPv2-SMI::enterprises.232.15.2.6.1.1.7.2 = INTEGER: 2 Total traversal time = 0.179010 seconds HowTo_Check_Windows_Cluster_via_SNMP_V1.2.doc 20.02.2009 Page 13 / 16

Possible Problems: Wrong IP-address No connection to the server -> check with ping Timeout value for SNMP call to low use parameter -T to increase the value (default 2 seconds) HowTo_Check_Windows_Cluster_via_SNMP_V1.2.doc 20.02.2009 Page 14 / 16

10. How To implement the plugin in Nagios Please execute perldoc check_mscs_hpma in nagios plugin directory for detailed documentation. If the plugin is running and you are happy with the functionality please vote at www.nagiosexchange.org Thank you! HowTo_Check_Windows_Cluster_via_SNMP_V1.2.doc 20.02.2009 Page 15 / 16

11. Some useful SNMP Articles http://www.enterprisenetworkingplanet.com/windows/article.php/3762946/manage-snmp- With-Windows-Servers.htm HowTo_Check_Windows_Cluster_via_SNMP_V1.2.doc 20.02.2009 Page 16 / 16