V101. VDSL LAN Extender



Similar documents
VDSL2 LAN Extender User Manual

Ethernet over VDSL2 PoE PD Converter

LevelOne User Manual VDS-0120 Ethernet over VDSL2 Converter (PSE)

SHDSL LAN EXTENDER H301A. User Manual

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

Long Range Ethernet Extender

Ethernet over VDSL2 Converter VC-201A / VC-204

VDSL Ethernet LAN Extender

IEX-402-SHDSL Series Quick Configuration Guide First Edition, January 2013

Detecting Bridged Tap and Noise Interference in VDSL2 Access Networks using the JDSU SmartClass TPS

Extending Ethernet over 2-wire Copper Networks

VDSL2 A feasible Solution for Last Mile

4-Port 10/100Base-TX with PoE + 1-Port BNC / RJ-11 Industrial Ethernet Extender

Digital Subscriber Line (DSL) Transmission Methods

TELECOMMUNICATIONS STANDARDS ADVISORY COMMITTEE TSAC WORKING GROUP ON NEW STANDARDS AND POLICY (NSP)

Black Box Explains: DSL

Elisa Carrier Services. Elisa Operator Broadband Services. Technologies, distribution centres and delivery interfaces

SOHOware Long Reach Ethernet (LRE) Solution

Public Switched Telephone System

VDSL Ethernet Extender AT-MC605. Installation Guide Rev. C

Intel System Engineers Documents. DSL General Overview

Characterization of a new copper cable for next generation DSL systems

Provides one channel for Ethernet over existing

T1 Networking Made Easy

XDSL and DSLAM Access Technologies

Acterna DSL Services Tester TPI 350+ Application Highlights

LevelOne VOI H.323 VoIP Gatekeeper. User Manual

How DSL Works. by Curt Franklin

Network Requirements for DSL systems, (ADSL through G.Fast) (A summarized view)

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

Network Neutrality Statement

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Broadband 101: Installation and Testing

TELECOMMUNICATIONS STANDARDS ADVISORY COMMITTEE WORKING GROUP ON COMMON CONNECTION STANDARDS (CCS)

DES-1005P 5-Port 10/100Mbps with 1-Port PoE Unmanaged Switch

ADSL MODEM. User Manual V1.0

Adaptive Spectrum and Signal Alignment, Incorporated THE RE-PROFILER DSM CLOSES THE CASE ON DIAGNOSING DSL/VDSL TROUBLES

Actiontec V1000W VDSL Gateway Static Business Class

FlexPoint T1/E1 Copper to Fiber Line Driver

Cisco G.SHDSL High Speed WAN interface Card with IEEE 802.3ah EFM Support for Cisco Integrated Services Routers

Copper to Fiber Stand-Alone Media Converter. Quick Installation Guide

Provides one channel for Ethernet over existing

V-DSL technology in the NBN

24-Port VDSL2/ADSL2+ with 2-Port Gigabit TP/SFP Combo IP DSLAM

Fiber to the Home. Definition. Overview. Topics

TELECOMMUNICATION SYSTEMS

Digital Subscriber Line (DSL)

IP DSLAM IDL Quick Installation Guide

IFS SP-PoE Splitter User Manual

Evolution from Voiceband to Broadband Internet Access

Trouble shooting Guide <<<Field and NOC Engineer Perspective>>>

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

Exam questions. 1. Which of the following are true regarding xdsl? Choose three. It uses a portion of the existing phone line.

Perle 10/100 Ethernet Media Converters

Model CFA-24 Transparent Cable Farm Automation Switch

Trinity Feature: DSL Configuration

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s. Manual

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual

DSL Variations. NEXTEP Broadband White Paper. Broadband Networks Group. Definitions and differences of Digital Subscriber Line variations.

Terminal and Dimension

CONTRIBUTION ABSTRACT

WHITE PAPER December, 2001

4-Band VDSL CO/CPE MODEM USER S MANUAL Ver. A.2. 4-Band VDSL CO/CPE Modem USER S MANUAL

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

NEW WORLD TELECOMMUNICATIONS LIMITED. 2 nd Trial Test Report on 3.5GHz Broadband Wireless Access Technology

8 Port Gigabit 10M/100M/1000M Fast Ethernet Switch. User Manual

TD-8610/TD-8610B External ADSL2+ MODEM

Gigabit Switching Ethernet Media Converters - Product User Guide

Power over Ethernet (PoE)

Broadband Services from MTNL. User's Guide

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

500M Powerline Pass-Through Ethernet Bridge

ADSL WAN Connections. Contents

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Motorola T5 Power Broadband Troubleshooting Guide. Motorola Solutions February, 2014

MOTOROLA CANOPY WIRELESS BROADBAND INTERNET ACCESS PLATFORM

How Enhanced DSL Technologies Optimize the Last Copper Mile By John Williams

MDI/MDIX) FEP-32008T-3

3 Residential VoIP Service

Carrier Ethernet: New Game Plan for Media Converters

Connection Services. Hakim S. ADICHE, MSc

Product Overview. Steve Erickson

The Product Description of SmartAX MT880 ADSL2+ CPE

Long Reach PoE over Coaxial Extender Kit

HDMI / Video Wall over IP Transmitter with PoE

HDMI over IP Broadcasting System ITEM NO.: HE05BT, HE05BER HDMI Matrix over IP Broadcasting

Speed-DSL 9.2 Ethernet connection over 8-wires up to 9.2 Mbit/s. Manual * * * *

emta (VoIP over Cable Modem)

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

By: Mohsen Aminifar Fall 2014

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

BEC 6200WZL. 4G/LTE Cellular Broadband Router. Quick Start Guide

HIGH CAPACITY DSL-SYSTEMS

Profitably Get High Speed, Reliable CE 2.0 Services Out to Small and Medium Business Using EFM over Copper

IP Express Multi-Service IP DSLAM

Transcription:

V101 VDSL LAN Extender User Manual Ver 1.01 1

Table of Content 1. Introductions... 3 2. Application Notes... 3 3. Features... 4 4. Packing Contents... 4 5. LED Indicators... 5 6. Dip Switches Settings... 5 7. Data Rates & Distances... 6 2

1. Introductions The V101, a VDSL (Very high-bit-rate Digital Subscriber Line) LAN Extender, provides a broadband transmission up to 100/60Mbps of downstream/upstream data rate over single pair copper line for point-to-point Ethernet connectivity. With 100/60Mbps data rate, V101 supports transmission distance up to 300 meters, and 30/10 Mbps for 1km long range connection. Users may also select a fixed data rate or a fixed SNR margin for different copper line ranging. With plug and play features and minimum installation time, each V101 can be configured into either CO for central side or RT for remote side by dip switch setting. The V101 conforms to the ITU-T G.993.1/2 to meet VDSL/VDSL2 and SG15Q4 DMT for network requirements. A pair of V101 offers a cost effective solution for bandwidth-hungry applications such as LAN-to-LAN connectivity, Video Streaming, FTTB, and VoIP over single twisted pair telephone line. 2. Application Notes 1) Ethernet To Ethernet Bridge Extension Central Office V101 VTU-C 100 / 60 Mbps up to 300 meters Remote Side V101 VTU-R Max 2km for VDSL Link 3

3. Features ITU-T G.993.1, G.993.2 VDSL/VDSL2 and SG15Q4 DMT Compliance 100/60Mbps DownSream/UpStream for distance up to 300 meters Supports VDSL connection up to 2000 meters Support Annex A, B, or C for internal splitter (option) RJ11 x 2 for DSL and POT interfaces + RJ45 for Ethernet LAN port Three LED Indicators 4 Dip Switches for Configuration Settings Trellis Coding support up to 1024 Discrete Multi-Tone (DMT) bins Auto MDIX for 10/100 BaseT Ethernet LAN Ports Low-Latency for Video/Voice/Data applications Selectable Fast and Interleaved modes Fast mode guarantees a minimum end to end latency less than 1 ms. Interleaved mode provides impulse noises protection for any impulse noise with a duration less than 250 us. Interleaved mode has a maximum end to end latency of 10 ms. Interleaved mode is the default mode. Selectable fixed data rate and fixed SNR margin User may select fixed SNR margin (9 db) or fixed target data rate. When fixed SNR margin is selected, the systems will maintain the SNR margin at 9 db across all available loop length. When fixed target data rate is selected, the system will lock the data rate at 50/20Mbps whenever the calculated SNR margin is higher than 9 db. This will result in the best system stability and is the default mode. 4. Packing Contents Inside the package you should find: (1) One V101 VDSL LAN Extender (2) One AC to DC Power Adaptor (5VDC/2A) (3) One User Manual CD Please check if the packing is damaged or any component is missing. If so, please contact your distributor. 4

5. LED Indicators On the front panel of V101, there are three LED indicators as the following POWER: Green On indicates power is on and normal. DSL: LAN: Green On indicates VDSL is in connection. Green On indicates Ethernet is in connection. Flashing indicates Ethernet data activities. 6. Dip Switches Settings Pin 1 Pin 2 Pin 3 Pin 4 VTU-C/R Mode Rate Limit SNR OFF VTU-C Interleaved 50/20 Mbps 9dB ON VTU-R Fast Full Rate 6dB Pin 1: VTU-C/R Switch VTU-C: V101 will act as at the Central Office (CO) side. VTU-R: V101 will act as at the Customer Premise Equipment (CPE) or Remote side. Pin 2: Mode for impulse noise protection Interleave mode: Protection for up to 250ms impulse noises with latency less than 6 ms. Fast mode: Direct data transmission with latency less than 1ms. 5

Pin 3: Rate limit control 50/20 Mbps: Line rate limited to 50/20 Mbps. Full Rate: Provides up to 100Mbps/60Mbps line rate in short line. Pin 4: Signal to Noise Ratio (SNR) 9dB: Higher SNR margin (9dB) will result in less error with more stable VDSL link. 6dB: Original and Normal channel noise protection with 6 db SNR. 7. Data Rates & Distances Performance in AWG 26 Line at 6dB with full rate Down Stream Data Rate (Mbps) Up Stream Data Rate (Mbps) Distance (feet) 100 60 500 98 53 1000 90 44 1250 80 36 1500 70 27 1750 60 18 2000 48 11 2500 39 8 3000 35 3.5 3500 28 0.3 4000 6