OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE



Similar documents
O-Z Care System. Model PF03

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

HYLA NST Cleaning System

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Installation Instructions WARNING: WARNING: WARNING: WARNING: WARNING:

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

D I G I T A L C L A M

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

Wessel-Werk EBK 340. Electric Power Nozzle. Operating Manual Wessel-Werk GmbH Im Bruch 2 D Reichshof Germany

EBK 340 / EBK 341 Electric Power Nozzle

Cambridge Electric Infared Fireplace User Manual

20 GALLON WET DRY VACUUM

Tablet 30W Tablet 92W

Meaco 30L and Meaco 40L dehumidifier instruction manual

GENANO 4500 MEDICAL AIR PURIFICATION DEVICE

Uses No Chemicals. Ozone Reverts Back to Oxygen. Eliminates Odor Electronically. Operates Unattended. Retards Bacterial Growth. Rapid Removal of Odors

Safety, Operation and Maintenance Manual with Parts List

Wessel-Werk EBK 360. Electric Power Nozzle. Operating Manual Wessel-Werk GmbH Im Bruch 2 D Reichshof Germany

Portable Air Conditioner

Split Type Room Air Conditioner. KSWM units

MBSAW. Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

Installation and Operating Instructions (for chargers shown below)

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

VACUUM CLEANER INSTRUCTION MANUAL

rainbowsystem.com Rexair LLC Troy, Michigan 2011 Rexair LLC R14388A-0 Printed in U.S.A.

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Dehumidifier Users manual. For Models: DH45S DH65S

AROS SMART WINDOW AIR CONDITIONER

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL

Anthro Tablet Charging Cabinets

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

IMPORTANT SAFETY RULES TO FOLLOW

HP UPS R1500 Generation 3

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

Cooktop Low-Profile Ventilation Hoods

Doorbell Intercom Security System

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

INFRARED QUARTZ WALL HEATER

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Advantium 2 Plus Alarm

ELECTRIC KNIFE SHARPENER

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Convection TCO600. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

Installation Instructions

Installation and Operating Instructions (for chargers shown below)

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

USER S MANUAL HSC-24A

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

the Soft Top Breville Customer Service Center Instruction Book - Livret d instructions

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

B100. single-line business telephone

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

GSM Door Phone System

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Installation Manual Version 7.3 IMPORTANT:

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Operating instructions Cordless K impact wrench

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

Operator Manual 100 Series Coffee Grinders

Room Air Conditioners

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Convection TCO650. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

15GAL STEEL OIL DRAIN WITH 110V PUMP

WARMER or COOKER/WARMER

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

Installation Instructions For Slider Casement Air Conditioners

GeekDesk Max Instructions for Assembly & Use

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

FOXAIR 60/50 ALL MODELS

16/32 Channel 1U Rack Mount CCTV Power Supply

ANI-64S-xRU. Single Section Wall Cabinet INSTRUCTION MANUAL

75th anniversary blender

car + boat Box Contents x2 x _DC16_CAR_BOAT_OPSMAN.indd 1 29/7/08 15:27:01

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

PORTABLE AIR CONDITIONER

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Owner s Manual. Not suitable for mobile applications. Important Safety Instructions 2. Quick Installation 3. Basic Operation 4. Storage & Service 7

LIEBERT VNSA Installation Sheet

Andersen Electric Window Opener for Andersen Awning and Roof Windows

How To Use A Power Supply Unit (Upu)

Ceiling Fan Installation Instructions

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

Transcription:

OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING: USE IN UNINHABITED AREAS ONLY. CONSULT MSDS SHEET BEFORE USE. Ozone attacks organic matter. Limited exposure can cause irritation to eyes, throat, and nose, and it may cause nausea. Do not re-inhabit a treated area until it has been well ventilated. Prolonged exposure can also affect certain organic materials such as rubber, plastic, wire insulation. Do not get the machine wet. 1 1-22-2010

NOTE: This machine is only suitable for commercial use, for example in hotels, schools, hospitals, factories, shops and offices other than normal residential housekeeping purposes. Serial Number: Model: Oasis-Plus Purchase Date: Write the name and phone number of your distributor: (and be sure to register your machine to activate the warranty) IMPORTANT SAFETY INSTRUCTIONS This machine is only suitable for commercial use, for example in hotels, schools, hospitals, factories, shops and offices other than normal residential housekeeping purposes. When using any electrical appliance, basic precautions should always be followed, including the following: NOTE: Read all instructions before using this machine. WARNING! To reduce the risk of fire, electric shock, or injury: USE IN UNINHABITED AREAS ONLY. To avoid electric shock, do not expose to rain or snow. Store, and use, indoors. Use only as described in this manual. Use only the manufacturer s recommended attachments. Do not use with damaged cord or plug. If the machine is not working as it should, has been dropped, damaged, left outdoors or dropped into water, return it to a service center. Do not pull by the cord, use the cord as a handle, close a door on the cord, or pull the cord around sharp edges or corners. Keep the cord away from heated surfaces. To unplug, grasp the plug, not the cord. Do not handle the plug, the cord or the machine with wet hands. Extension cords must be 12/3 and no longer than 50 feet. Replace the cord or unplug immediately if the ground prong becomes damaged. Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow. Connect to a properly grounded outlet only. 2

INSPECTION: Carefully unpack and inspect the OASIS PLUS for shipping damage. Each unit is tested and inspected before shipment. Any damage incurred is the responsibility of the carrier, who should be notified immediately. All cleaning and maintenance work should be completed before using the Ozone machine. Ozone treatment should be the final step in room maintenance. NOTE: the air flowing into the machine must be clean and dry. NOTE: if the air intake filter is dirty or missing warranty is voided. OPERATION: NOTE: OZONE IS A TOXIC GAS. FOLLOW ALL SAFETY PRECAUTIONS. 1. Make certain all people, pets, and plants are out of area. Close all windows and doors. 2. Make sure the filter in front of the cooling fan is installed and is clean. 3. Place the Oasis Plus unit on a shelf or tabletop as high as possible in the area to be treated. 4 Plug the power cord into a grounded, 3-prong outlet. 5. Set the timer to the desired length of time. Momentarily pressing the UP timer button for one second will increase the time setting by one minute at a time. Hold the button for 1-3 seconds to change the time value by two minutes per second. Hold the button for longer than 3 seconds and the time setting will change in 20 minutes increments. The maximum time setting is 29:59 hours. After reaching the maximum time, the timer will wrap back to 00:00 and then continue increasing. When the time is being decreased and reaches 00:00, it will wrap to 29:59 and continue decreasing. 6. Select the desired power level: 25%; 50%; 75% 100%. The Oasis Plus always defaults to 100% when you plug it in. When the output level is set to 100%, the machine makes ozone continuously until the timer runs out or the OFF button is pressed. At other power level settings, the machine will produce ozone for the fraction of a minute the level is set at. For example, if the output level is set to 75%, the machine will produce ozone for 75% (45 seconds) of each minute. At 50%, ozone is generated for 30 seconds of each minute, and at 25%, the ozone generation lasts for 15 seconds of each minute. On any setting other than 100%, the ozone generator will be cycling the ozone ON and OFF. 7. Turn the unit on by pressing the ON button. Leave the area immediately. 8. When treatment is complete, unplug the ozone machine and ventilate the area completely until all smell of ozone is gone. Do NOT allow people, pets, or plants back into the area until all smell of ozone has dissipated. 3

TIME GUIDELINES: This Oasis Plus unit will control biological contamination and odor in areas up to 40,000 FT 3. Use the following times as a guideline. Hotel/Motel Room: 20 -- 60 Minutes Automobiles: 20 -- 30 Minutes Fire & Flood Restoration: 12 -- 72 Hours. For Automobiles: Refer to Figure 1 and Figure 2 below 1. Install the hose onto the electrode chamber. Secure the hose with the hose clamp. 2. Set the Ozone Plus on top of the car or on a cart or table next to the car. 3. Install the foam block into a partially closed car window, and insert the hose through the hole in the foam. 4. Set the time and the output level. 5. Turn the ozone machine ON. When treatment is complete, ventilate the car completely. Repeat treatment if necessary. Figure 1 HOSE CLAMP FOAM Figure 2 NOTE: Ozone destroys odor causing molecules, thus eliminating the source of the odor. The length of time this process takes will vary depending on the amount of contaminants the ozone has to work on, the amount of area being treated, temperature and humidity, the amount and type of furniture in the area, etc. NOTE: the process can produce a haze in the treatment area. 4

9 11 24 August 2008 12 10A 10 3 2 3A 5 20 13 3B 16 6 4 23 22 9 7 21 15 14 17 6 7A OASIS PLUS 120V 18 19 1 8 7 ITEM No. DESCRIPTON PART No. #1 Housing OZ-1 #2 Terminal Block OZ-10 #3A Bolt, 3/8 X 1/2 326 #3 Stud, 3/8 X 1-1/8" 327 #3B Nut, finish 3/16-16 259 #4 Safety Switch OZ-8 #5 Circuit Breaker, 1/2 amp OZ-5 #6 Bolt 364 #7 Electrode Chamber FP242 #7A Electrode Assembly FP241 #8 Hose Clamp 198 #9 Fan 2014 #10 Lock nut 324 #10A Bolt, 8/32 X 2-1/2 323 #11 Fan cover + filter 2015A #12 Filter only 2015B #13 Screw, 4-40 X 5/8" S/S 328 #14 Bracket, for safety switch OZ-22 #15 Lock nut 4-40, S/S 18 #16 Transformer OZ-4-PTI-1 #17 Mounting Plate, bottom OZ-18AC #18 Power Cord, 6 ft OZ-11 #19 Cord Retainer 230 & 230A #20 Control Board Assembly OZ-17 #21 Touch Pad OZ-20 #22 Gasket OZ-16A #23 Bezel OZ-16 #24 Label OZ-23 5

POWER CORD TRANSFORMER HIGH VOLTS OUT PRINTED CIRCUIT BOARD OZ HOT OZ NEUTRAL FAN HOT FAN NEUTRAL AC NEUTRAL AC HOT RED 14GA BLACK 9 GREEN 8 CIRCUIT BREAKER SAFETY SWITCH FAN 6-1/2 HIGH VOLTAGE ELECTRODE CHAMBER GROUND SCREW WASHER #1096 LOCKNUT #358 #147 8 3 PAIR (6 WIRES) 8 8 BLACK 18 GA 9 GREEN 14 GA 16-1/2 GREEN 18 GA 9 #64 = #146 (BLUE ON 240V) = #334 (BROWN ON 240V) OZ-11 #2019 FOR 240V #2051 WHITE 18GA 22 WHITE 16 GA 8 BLACK 16 GA 16-1/2 12 12 16 #320 * #320 * EMPTY * cover the metal on both #320 with heat shrink #64 6-1/2 120V OR 240V 100V = OZ-17-100 120V = OZ-17 240V = OZ-240 #65 GREEN 14 GA 9-1/4 RING CONNECTOR #334 6

TROUBLE SHOOTING: CAUTION: ALWAYS UNPLUG THE MACHINE BEFORE YOU DO ANY INTERNAL TROUBLESHOOTING IF THIS OCCURS NO POWER TIMER DOES NOT WORK THE % of OZONE DOES NOT WORK CHECK THIS Look at the power cord, to make sure it is plugged in. Check the outlet, to make sure it has power in it. Look at the circuit breaker on the bottom of the machine, to make sure it has not tripped. Check the internal safety switch to make sure it is activated when the bottom cover is on. The digital display has segments missing from some numbers. The timer or buttons do not change the time display. The time display does not change as time passes. < < The % button does not work. The amount of ozoneoutput does not change. The % button does work, but one (or more) of the red LEDs is not lighting. NOTE: if the air intake filter is dirty or missing warranty is voided. SPECIFICATIONS and FEATURES: Output volume: Maximum Output: Timer: Production Method: Air Flow: Deminsions: Weight: Warranty: Variable 2.2 gm/hr; 6.6 ppm Digital, 00:00 to 29:59 hours Patented, high-density and stainless steel electrodes 100 CFM 8 H X 8 W X 22 L 12-1/2 lbs 3 year; lifetime on electrodes * Rugged construction means reliability No maintainence of plates or UV tubes Over-load protection * A dirty or missing filter at the air intake voids the warranty 7

OASIS-PLUS 120V NOTES: 208-772-0573 800-257-7982 FAX: 208-772-0577 Coeur d Alene, Idaho VISIT US AT: http://www.usproducts.com 8